MPL-01SE Series Single Output, 1W Ultra-Miniature SIP AC/DC Power Supplies Key Features: Electrical Specifications • 1W Output Power • Universal 85-264 VAC Input • EN 60950 Approved (UL) • Meets IEC Safety Class II • Single Regulated Output • Meets EN 55022 Class A • >300 kHour MTBF • Ultra-Miniature “SIP” Case Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Input Voltage Range Input Frequency Input Current Inrush Current Standby Power Min. Typ. 85 100 47 See Model Selection Guide 115 VAC 10.0 230 VAC 20.0 0.3 Max. 264 400 63 Conditions Min. Typ. See Model Selection Guide See Model Selection Guide See Model Selection Guide ±1.5 VIN = Min to Max IOUT = 5% to 100% ±2.5 5V, 24V Models 100 9V, 12V, 15V Models 80 230 VAC 50 ±0.01 Continuous (Autorecovery) Max. Units VAC VDC Hz A Pk W Output Parameter Output Voltage Output Current Output Voltage Accuracy, See Note 1 Line Regulation Load Regulation Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Short Circuit Protection Over Temperature Protection Units % % 150 120 mV P-P mSec %/°C 150 °C Max. Units VAC kHz General Parameter Isolation Voltage Switching Frequency EMI Characteristics Parameter Radiated Emissions Conducted Emissions ESD RS EFT Surge CS PFMF Voltage Dips Conditions Input to Output Min. 3,000 Typ. 50 Standard See Note 3 EN 55022 See Note 3 EN 55022 EN 61000-4-2 See Note 4 EN 61000-4-3 See Note 5 EN 61000-4-4 See Note 6 EN 61000-4-5 See Note 7 EN 61000-4-6 EN 61000-4-8 EN 61000-4-11 Min. Typ. Max. Units Class A Class A Criteria B; ±4 kV Contact Criteria A; 10V/m Criteria B; ±2 kV Criteria B; ±1 kV /±2 kV Criteria A; 3 Vrms Criteria A; 10A/m Criteria B; 0% - 70% Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Max. +85 +90 -40 +105 Free Air Convection (See Derating Curve) RH, Non-condensing 85 Ambient Case Min. -40 Typ. +25 Units °C °C °C % Physical Case Size Case Material Weight 1.38 x 0.43 x 0.94 Inches (35.0 x 11.0 x 24.0 mm) Non-Conductive Epoxy (UL94-V0) 0.35 Oz (10g) Reliability Specifications Parameter MTBF Safety Standards Safety Class Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 300 EN 60950 IEC 61140 Class II www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Notes: Output 1. For the 5V output model, accuracy is ±10% over the -40°C to +85°C temperature range. Voltage Efficiency Operation at no load will not damage the units, however, they may not meet all specifications. Current (A) Voltage Current Accuracy (%, Typ) 2. 3. All units are rated for EN 55022 (CE/RE) class A without external components. They will meet class B with (VDC) (mA Max.) (%) 115 VAC 230 VAC the addition of the ACFM-01 (or a similar discrete filter circuit). Contact the factory for more information. 4. To meet the requirements of EN 61000-4-3, (10V/m) external components are needed. This can be done 0.120 0.060 5.0 200 ±5.0 66 discretely, or with the addition of the ACFM-01. Contact the factory for more information. 5. To meet the requirements of EN 61000-4-4 (±4 kV), external components are needed. This can be done 0.120 0.060 9.0 111 ±3.0 67 discretely, or with the addition of the ACFM-01. Contact the factory for more information. 6. To meet the requirements of EN 61000-4-5 (±4 kV/±4 kV), external components are needed. This can be 0.120 0.060 12.0 83.3 ±3.0 70 done discretely, or with the addition of the ACFM-01. Contact the factory for more information. 0.120 0.060 15.0 66.6 ±5.0 69 7. To meet the requirements of EN 61000-4-6 (3V rms), external components are needed. This can be done discretely, or with the addition of the ACFM-01. Contact the factory for more information. 0.120 0.060 24.0 41.6 ±5.0 68 8. It is recommended that a fuse be used on the input of a power supply for protection. For the MPL-01SE series, a 1.0A/250 VAC slow blow should be used. Input Model Number MPL-01S-05E MPL-01S-09E MPL-01S-12E MPL-01S-15E MPL-01S-24E Typical Connection Output The diagram below illustrates a typical application connection of the MPL-01SE series. Notes on this circuit (starting with the input circuit) are: 1. It is recommended that an external fuse and NTC be used. The recommended fuse is a 1.0A/250V slow blow and for the NTC, a 5D-9. 2. An external MOV is recommended on the input to protect the unit in the event of a surge. A 561KD14 or equivalent is recommended. 3. The filter capacitor C1 is required for EMC performance over the full input range. The recommended value is 10 to 22 µF/400V. 4. Recommended output filtering capacitors are: MPL-01S-05E MPL-01S-09E MPL-01S-12E MPL-01S-15E MPL-01S-24E Typical Board Layout: With ACFM-01 Input Module (See note 5) C2 1.0 µF/50V 1.0 µF/50V 1.0 µF/50V 1.0 µF/50V 1.0 µF/50V C3 470 µF/35V 150 µF/35V 150 µF/35V 150 µF/35V 100 µF/35V TVS SMBJ7.0A SMBJ12A SMBJ20A SMBJ20A SMBJ30A The output filtering capacitor (C3) is a high frequency, low resistance electrolytic capacitor. Capacitor (C2) is ceramic. Voltage derating of capacitors should be 80% or above. 5. Input noise and surge suppression modules are available for a number of MPD AC/DC power supplies. An MPL-01SE connection with the ACFM-01 is illustrated in the diagram at left. For pricing or full technical information on these modules (ACFM-01 and ACFM-02) please contact the factory. Pin Connections Derating Curve Pin Function Pin Function 1 3 5 AC-Neutral AC-Line +VCAP 7 10 12 -VCAP -VOUT +VOUT Mechanical Dimensions Input Voltage Vs Load MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) FAX: (781) 344-8481 • E-Mail: [email protected]