MPB-05S Series Miniature PCB-Mount, 5W, Open Frame AC/DC Power Supplies Electrical Specifications Key Features: • 5W Output Power • Universal 85-264 AC Input • EN 60950 Approved (UL) Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter • Meets IEC Safety Class II • Meets EN 55022 B Inrush Current • Efficiency To 80% • >200 kHour MTBF Min. Typ. 85 127 47 Meets EN 55022 Class B See Model Selection Guide Cold Start, 115 VAC Cold Start, 230 VAC 264 VAC Universal Input Voltage Range Input Frequency Input Filter Input Current • PCB Mountable Conditions Safety Ground Leakage Current Max. 264 373 63 25.0 40.0 0.25 Units VAC VDC Hz A Pk mA Output Parameter Output Voltage/Current Output Voltage Tolerance Line Regulation Load Regulation Ripple & Noise (20 MHz) Conditions Min. Typ. See Model Selection Guide See Note 1 ±1.0 Vin = 100 VAC to 240 VAC ±0.5 Iout = 10% to 100% ±1.0 See Note 2 ±1.0 115 VAC 8 230 VAC 60 ±0.05 Continuous (Autorecovery) 170 Hold-Up Time Temperature Coefficient Short Circuit Protection Overload Protection Max. Units % % % % mSec %/°C % General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance EMI/RFI Conditions Input to Output 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Fixed EMC Compliance Switching Frequency Min. 3,000 Typ. Max. Units VAC 100 M⍀ 1,100 pF EN 55022; EN 61000-3-2, -3 IEC/EN 61000-4-2, -6, -8, -11 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 66 kHz Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Size Weight Conditions Min. Typ. Max. 0 +25 +70 -20 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 93 Ambient Units °C °C % 2.16 x 1.378 x 0.827 Inches (55.0 x 35.0 x 21.0 mm) 1.23 Oz (0.035 kg) Reliability Specifications Parameter MTBF Safety Standards Vibration Conditions Min. Typ. Max. Units MIL HDBK 217F, 25°C, Gnd Benign 200 kHours UL 60950, EN 60950 Sinusoidal 50~500 Hz, 3.0 Grms, Period of 30 min each along X, Y & Z Axis www.micropowerdirect.com www.micropowerdirect.com Model Selection Guide Model Number MPB-05S-03 MPB-05S-05 MPB-05S-09 MPB-05S-12 MPB-05S-15 MPB-05S-18 MPB-05S-24 Input Current (A) 115 VAC 230 VAC 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.07 0.07 0.07 0.07 0.07 0.07 0.07 Voltage (VDC) 3.3 5.0 9.0 12.0 15.0 18.0 24.0 Output Current (A) Rated % Min. 1.25 1.00 0.55 0.42 0.33 0.28 0.23 Other Models May Be Available. Contact The Factory For Details 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Max Output Power Efficiency (%, Typ) (W) 4.12 5.00 5.00 5.00 5.00 5.00 5.50 70 73 76 77 78 78 80 Derating Curve Notes: 1. Output voltage tolerance is measured at nominal input and 75% load. 2. Output ripple is measured at 20 MHz bandwidth using 0.1 µF and 10 µF capacitors connected in parallel as close to the power supply terminals as possible. 3. These units will operate at no load without damage. For most applications however, MPD recommends that a minimum load always be used. Contact the factory for more information. 4. Each unit includes an input fuse (250V/1A). Since this fuse is not field replaceable, it is recommended that an external fuse of the same size be used on the input of the power supply for protection. Mechanical Dimensions Pin Connections Pin 1 2 3 4 Description AC-Neutral AC-Line -V Output +V Output Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]