MPD MPB-05S

MPB-05S Series
Miniature PCB-Mount,
5W, Open Frame
AC/DC Power Supplies
Electrical Specifications
Key Features:
• 5W Output Power
• Universal 85-264 AC Input
• EN 60950 Approved (UL)
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
• Meets IEC Safety Class II
• Meets EN 55022 B
Inrush Current
• Efficiency To 80%
• >200 kHour MTBF
Min.
Typ.
85
127
47
Meets EN 55022 Class B
See Model Selection Guide
Cold Start, 115 VAC
Cold Start, 230 VAC
264 VAC
Universal
Input Voltage Range
Input Frequency
Input Filter
Input Current
• PCB Mountable
Conditions
Safety Ground Leakage Current
Max.
264
373
63
25.0
40.0
0.25
Units
VAC
VDC
Hz
A Pk
mA
Output
Parameter
Output Voltage/Current
Output Voltage Tolerance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Conditions
Min.
Typ.
See Model Selection Guide
See Note 1
±1.0
Vin = 100 VAC to 240 VAC
±0.5
Iout = 10% to 100%
±1.0
See Note 2
±1.0
115 VAC
8
230 VAC
60
±0.05
Continuous (Autorecovery)
170
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Overload Protection
Max.
Units
%
%
%
%
mSec
%/°C
%
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
EMI/RFI
Conditions
Input to Output
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Fixed
EMC Compliance
Switching Frequency
Min.
3,000
Typ.
Max.
Units
VAC
100
M⍀
1,100
pF
EN 55022; EN 61000-3-2, -3
IEC/EN 61000-4-2, -6, -8, -11
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
66
kHz
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Size
Weight
Conditions
Min.
Typ.
Max.
0
+25
+70
-20
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
93
Ambient
Units
°C
°C
%
2.16 x 1.378 x 0.827 Inches (55.0 x 35.0 x 21.0 mm)
1.23 Oz (0.035 kg)
Reliability Specifications
Parameter
MTBF
Safety Standards
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
200
kHours
UL 60950, EN 60950
Sinusoidal 50~500 Hz, 3.0 Grms, Period of 30 min each along X, Y & Z Axis
www.micropowerdirect.com
www.micropowerdirect.com
Model Selection Guide
Model
Number
MPB-05S-03
MPB-05S-05
MPB-05S-09
MPB-05S-12
MPB-05S-15
MPB-05S-18
MPB-05S-24
Input
Current (A)
115 VAC
230 VAC
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.07
0.07
0.07
0.07
0.07
0.07
0.07
Voltage
(VDC)
3.3
5.0
9.0
12.0
15.0
18.0
24.0
Output
Current (A)
Rated
% Min.
1.25
1.00
0.55
0.42
0.33
0.28
0.23
Other Models May Be Available. Contact The Factory For Details
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Max
Output
Power
Efficiency
(%, Typ)
(W)
4.12
5.00
5.00
5.00
5.00
5.00
5.50
70
73
76
77
78
78
80
Derating Curve
Notes:
1. Output voltage tolerance is measured at nominal input and 75% load.
2. Output ripple is measured at 20 MHz bandwidth using 0.1 µF and 10 µF
capacitors connected in parallel as close to the power supply terminals
as possible.
3. These units will operate at no load without damage. For most applications however, MPD recommends that a minimum load always be used.
Contact the factory for more information.
4. Each unit includes an input fuse (250V/1A). Since this fuse is not field
replaceable, it is recommended that an external fuse of the same size
be used on the input of the power supply for protection.
Mechanical Dimensions
Pin Connections
Pin
1
2
3
4
Description
AC-Neutral
AC-Line
-V Output
+V Output
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]