MPO-100S Series Single Output, 100W Miniature, Open Frame AC/DC Power Supplies Electrical Specifications Key Features: • 100W Output Power • PFC to EN61000-3-2,3 “D” • Universal 90-264 AC Input Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter • Miniature 2 x 4 In Package • Meets EN 55022 B Inrush Current • Meets EN 61000-4 • >400 kHour MTBF Min. Typ. Max. 90 264 127 373 47 63 Meets EN 55022 Class B; FCC Class B See Model Selection Guide Cold Start, 115 VAC 40.0 Cold Start, 230 VAC 90.0 264 VAC 3.5 Universal Input Voltage Range Input Frequency Input Filter Input Current • EN 60950 Approved (UL) Conditions Safety Ground Leakage Current Units VAC VDC Hz A Pk mA Output Parameter Output Voltage/Current Output Voltage Tolerance Line Regulation Load Regulation Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Short Circuit Protection Overvoltage Protection Conditions Min. Typ. See Model Selection Guide See Note 1 ±1.0 Vin = Min to Max ±0.5 Iout = 10% to 100% ±1.0 See Note 2 ±1.0 115 VAC 10 230 VAC 18 ±0.05 Continuous (Autorecovery) See Note 3 130 Max. Conditions Input to Output 500 VDC Max. Units % % % mSec %/°C % General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance EMI/RFI Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Fixed EMC Compliance Switching Frequency Min. 4,000 Typ. Units VAC 1,000 M⍀ 3,300 pF EN 55022; EN 61000-3-2, -3 IEC/EN 61000-4-2, -6, -8, -11 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 66 kHz Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Size Weight Conditions Min. Typ. Max. -10 +25 +70 -20 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 93 Ambient Units °C °C % 4.00 x 2.00 x 1.10 Inches (101.60 x 50.08 x 27.94 mm) 5.99 Oz (0.170 kg) Reliability Specifications Parameter MTBF Safety Standards Vibration Conditions Min. Typ. Max. Units MIL HDBK 217F, 25°C, Gnd Benign 400 kHours UL 60950, EN 60950 50~500 Hz, 3G 10 min/1 Cycle. Period of 30 min each along X, Y & Z Axis www.micropowerdirect.com www.micropowerdirect.com Model Selection Guide Model Number MPO-100S-12 MPO-100S-15 MPO-100S-24 MPO-100S-48 Input Current (A) 115 VAC 230 VAC 1.05 1.05 1.05 1.05 0.60 0.60 0.60 0.60 Voltage (VDC) 12.0 15.0 24.0 48.0 Notes: 1. Output voltage tolerance is measured at nominal input and 60% load. 2. Output ripple is measured at 20 MHz bandwidth using a 0.1 µF and 10 µF capacitor connected in parallel as close to the power supply terminals as possible. 3. These units will operate at no load without damage. For most applications however, MPD recommends that a minimum load always be used. Contact the factory for more information. 4. Metal spacers should be used on the holes marked “FG” when mounting the unit. 5. Each unit includes an input fuse (250V/2A). Since this fuse is not field replaceable, it is recommended that an external fuse of the same size be used on the input of the power supply for protection. Output Current (A) Rated % Min. 8.40 6.70 4.20 2.10 0.00 0.00 0.00 0.00 Max Output Power Max Output Capacitance (W) (µF) 100 100 100 100 6,000 6,000 4,450 3,700 Efficiency (%, Typ) 85 85 85 85 Derating Curve Mechanical Dimensions Connections Input Connector (CN1): • Molex 5277-03 or equivalent (one pin removed) • Mating Housing: Molex 5195-03 or equivalent • Mating Terminal: Molex 5194 or equivalent Pin Function 1 2 3 AC-Line Removed AC-Neutral Metal spacers should be used on the holes marked “FG” when mounting the unit. The input side mounting hole marked “FG” provides the safety earth ground for the unit. This connection should be locked to prevent possible loosening. Output Connector (CN2): • Molex 5273-04 or equivalent • Mating Housing: Molex 5195-04 or equivalent • Mating Terminal: Molex 5293 or equivalent Pin Function 1 2 3 4 +VOUT +VOUT -VOUT -VOUT Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]