MPO-100S Datasheet - Micropower Direct

MPO-100S Series
Single Output, 100W
Miniature, Open Frame
AC/DC Power Supplies
Electrical Specifications
Key Features:
• 100W Output Power
• PFC to EN61000-3-2,3 “D”
• Universal 90-264 AC Input
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
• Miniature 2 x 4 In Package
• Meets EN 55022 B
Inrush Current
• Meets EN 61000-4
• >400 kHour MTBF
Min.
Typ.
Max.
90
264
127
373
47
63
Meets EN 55022 Class B; FCC Class B
See Model Selection Guide
Cold Start, 115 VAC
40.0
Cold Start, 230 VAC
90.0
264 VAC
3.5
Universal
Input Voltage Range
Input Frequency
Input Filter
Input Current
• EN 60950 Approved (UL)
Conditions
Safety Ground Leakage Current
Units
VAC
VDC
Hz
A Pk
mA
Output
Parameter
Output Voltage/Current
Output Voltage Tolerance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Overvoltage Protection
Conditions
Min.
Typ.
See Model Selection Guide
See Note 1
±1.0
Vin = Min to Max
±0.5
Iout = 10% to 100%
±1.0
See Note 2
±1.0
115 VAC
10
230 VAC
18
±0.05
Continuous (Autorecovery)
See Note 3
130
Max.
Conditions
Input to Output
500 VDC
Max.
Units
%
%
%
mSec
%/°C
%
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
EMI/RFI
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Fixed
EMC Compliance
Switching Frequency
Min.
4,000
Typ.
Units
VAC
1,000
M⍀
3,300
pF
EN 55022; EN 61000-3-2, -3
IEC/EN 61000-4-2, -6, -8, -11
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
66
kHz
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Size
Weight
Conditions
Min.
Typ.
Max.
-10
+25
+70
-20
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
93
Ambient
Units
°C
°C
%
4.00 x 2.00 x 1.10 Inches (101.60 x 50.08 x 27.94 mm)
5.99 Oz (0.170 kg)
Reliability Specifications
Parameter
MTBF
Safety Standards
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
400
kHours
UL 60950, EN 60950
50~500 Hz, 3G 10 min/1 Cycle. Period of 30 min each along X, Y & Z Axis
www.micropowerdirect.com
www.micropowerdirect.com
Model Selection Guide
Model
Number
MPO-100S-12
MPO-100S-15
MPO-100S-24
MPO-100S-48
Input
Current (A)
115 VAC
230 VAC
1.05
1.05
1.05
1.05
0.60
0.60
0.60
0.60
Voltage
(VDC)
12.0
15.0
24.0
48.0
Notes:
1. Output voltage tolerance is measured at nominal input and 60%
load.
2. Output ripple is measured at 20 MHz bandwidth using a 0.1 µF and
10 µF capacitor connected in parallel as close to the power supply
terminals as possible.
3. These units will operate at no load without damage. For most applications however, MPD recommends that a minimum load always
be used. Contact the factory for more information.
4. Metal spacers should be used on the holes marked “FG” when
mounting the unit.
5. Each unit includes an input fuse (250V/2A). Since this fuse is not
field replaceable, it is recommended that an external fuse of the
same size be used on the input of the power supply for protection.
Output
Current (A)
Rated
% Min.
8.40
6.70
4.20
2.10
0.00
0.00
0.00
0.00
Max
Output
Power
Max
Output
Capacitance
(W)
(µF)
100
100
100
100
6,000
6,000
4,450
3,700
Efficiency
(%, Typ)
85
85
85
85
Derating Curve
Mechanical Dimensions
Connections
Input Connector (CN1):
• Molex 5277-03 or equivalent (one pin removed)
• Mating Housing: Molex 5195-03 or equivalent
• Mating Terminal: Molex 5194 or equivalent
Pin
Function
1
2
3
AC-Line
Removed
AC-Neutral
Metal spacers should be used on the holes marked “FG”
when mounting the unit. The input side mounting hole
marked “FG” provides the safety earth ground for the
unit. This connection should be locked to prevent possible
loosening.
Output Connector (CN2):
• Molex 5273-04 or equivalent
• Mating Housing: Molex 5195-04 or equivalent
• Mating Terminal: Molex 5293 or equivalent
Pin
Function
1
2
3
4
+VOUT
+VOUT
-VOUT
-VOUT
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]