MPM-10 Series Compact, 10W PC Mount Single, Dual & Dual ISO Out AC/DC Power Supplies Electrical Specifications Key Features: Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input • 10W Output Power Parameter • Universal 85-264 VAC Input Input Voltage Range • EN 60950 Approved (UL) Conditions Input Frequency • Single, Dual & Dual Iso Outputs Input Current • Meets EN 55022 B Inrush Current • >200 kHour MTBF • Compact PC Mount Case EMI Safety Ground Leakage Current Min. Typ. 85 120 47 See Model Selection Guide 115 VAC 10.0 230 VAC 20.0 Meets CISPR Pub. 22/FCC Class B 115 VAC 230 VAC Max. 264 370 63 Units VAC VDC Hz A Pk 0.1 0.3 mA Max. Units Output Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation, See Note 1 Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Short Circuit Protection Overload Protection Conditions Min. Typ. See Model Selection Guide See Model Selection Guide ±2.0 ±0.5 See Model Selection Guide 50 115 VAC 20 230 VAC 80 ±0.02 Continuous (Autorecovery) Typ. 110% of Output Power % mV Pk - Pk mSec %/°C General Parameter Isolation Voltage EMI/RFI EMC Compliance Conditions Input to Output Input to Ground Output to Ground Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Min. 3,000 1,500 500 Conditions Min. -25 Switching Frequency Typ. Max. Units VAC EN 55022 Level B EN 61000-4-2 Level 3 6kV/8kV EN61000-4-3 EN 61000-4-4 Level 3 2 kV EN 61000-4-5 Level 3 1kV/2 kV 150 kHz Environmental Parameter MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Max. +70 +90 -25 +105 Free Air Convection (See Derating Curve) RH, Non-condensing 85 Ambient Case Typ. +25 Units °C °C °C % 2.16 x 1.77 x 0.81 Inches (55.0 x 45.0 x 20.5 mm) Non-Conductive Black Plastic (UL94-V0) 4.23 Oz (120g) Reliability Specifications Parameter MTBF Safety Standards Safety Approvals Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 200 UL 60950, EN 60950 UL, cUL; File No. E245422 www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Input Model Number Current (A) Voltage 115 VAC 230 VAC MPM-10S-03 MPM-10S-05 MPM-10S-09 MPM-10S-12 MPM-10S-15 MPM-10S-24 MPM-10D-05 MPM-10D-12 MPM-10D-15 MPM-10D-24 MPM-10ID-0505 MPM-10ID-0512 MPM-10ID-0515 MPM-10ID-0524 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 Output 2 (Vout 2) Output 1 (Vout 1) 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 Output 3 (Vout 3) Over Volt. Voltage Current (A) Over Volt. Voltage Current (A) Efficiency (%, Typ) Load Protection (VDC) Rated Load Protection (VDC) Rated Load (VDC) (VDC) Reg. Reg. Reg. ±1.0% 6.5 70 ±1.0% 6.5 76 ±1.0% 12.0 78 ±1.0% 20.0 80 ±1.0% 20.0 81 ±1.0% 30.0 82 ±2.0% 6.5 -5.0 -1.00 ±2.0% 6.5 76 ±2.0% 20.0 -12.0 -0.45 ±2.0% 20.0 80 ±2.0% 20.0 -15.0 -0.35 ±2.0% 20.0 81 ±2.0% 30.0 -24.0 -0.20 ±2.0% 30.0 84 ±3.0% 6.5 5.0 0.20 ±5.0% 6.5 75 ±3.0% 6.5 12.0 0.20 ±5.0% 20.0 79 ±3.0% 6.5 15.0 0.20 ±5.0% 20.0 79 ±3.0% 6.5 24.0 0.20 ±5.0% 30.0 81 Current (A) (VDC) Rated 3.3 5.0 9.0 12.0 15.0 24.0 +5.0 +12.0 +15.0 +24.0 5.0 5.0 5.0 5.0 2.00 2.00 1.10 0.90 0.70 0.45 +1.00 +0.45 +0.35 +0.20 1.80 1.50 1.40 1.00 Notes: 1. Load regulation is measured for an output change of 10% to 90% at nominal input line. For multiple output models, the loads are balanced. 2. The MPM-10 series is specified for operation over the wide operating temperature range of -25°C to +55°C without derating. For operation over +55°C, derate the power linearly by 3.75%/°C from +55°C to +70°C. 3. Model numbers MPM-10ID-05xx are dual isolated units (Dual ISO). The outputs on these models are isolated from each other. 4. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-10 series, a 2A/250 VAC slow blow should be used. Typical Connection Mechanical Dimensions Typical Component Values Vout C1, C3 C2, C4 Fuse TVS 3.3 330 ~ 1,000 µF/16V P6KE6.8A 5.0 330 ~ 1,000 µF/16V P6KE6.8A 2A/ 0.1 µF/50V 250 VAC 12.0 220 µF/25V P6KE16A Ceramic Slow Blow 15.0 220 µF/25V P6KE20A 24.0 120 µF/35V P6KE33A Notes: 1. C1 and C3 are high frequency, low resistance electrolytic capacitors. Refer to the suppliers specifications for capacitance/current ratings. 2. Voltage derating on all capacitors should be 80% or higher. 3. C2 and C4 eliminate high frequency noise. 4. The TVS is recommended to protect load circuitry in the event of a module failure. Pin Connections Pin 1 2 3 4 5 6 7 8 Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) Single Dual Dual ISO AC-Ground AC-Ground AC-Ground AC-Neutral AC-Neutral AC-Neutral AC-Line AC-Line AC-Line -Vo 1 -Vo 2 -Vo 1 No Pin No Pin +Vo 1 No Pin Common No Pin No Pin No Pin -Vo 2 +Vo 1 +Vo 1 +Vo 2 MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]