MPD ACP111E

ACP100E Series
Low Cost, 1W
Ultra-Miniature
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 1W Output Power
Parameter
• Miniature Low Profile Case
Conditions
Input Voltage Range
• DCP01 Series Replacement
• 1,500 VDC Isolation
• Short Circuit Protected
• >3.5 MHour MTBF
• SMT Ver Available (LCP100E)
• LOW, LOW COST!!
Min.
Typ.
Max.
5 VDC Input
4.50
5.0
5.50
12 VDC Input
10.80
12.0
13.20
Typ.
Max.
Input Filter
Units
VDC
Internal Capacitor
Output
Parameter
Conditions
Min.
Output Voltage Accuracy
Line Regulation
±3.0
For Vin Change of 1%
Load Regulation, See Note 1
Units
%
±1.2
%
See Model Selection Guide
Ripple & Noise (20 MHz), See Note 3
50% Iout
20
100% Iout
50
Temperature Coefficient
Output Short Circuit, See Note 4
75
mV P - P
±0.03
%/°C
Max.
Units
Continuous (Autorecovery)
General
Parameter
Conditions
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Min.
60 Seconds
1,500
500 VDC
1,000
100 kHz, 1V
Switching Frequency
Typ.
VDC
M
25
pF
100
kHz
Environmental
Parameter
Conditions
Operating Temperature Range
Ambient
Operating Temperature Range
Case
Storage Temperature Range
Min.
Typ.
-40
+25
-55
Cooling
Max.
Units
+85
°C
+100
°C
+125
°C
95
%
Free Air Convection
Humidity
RH, Non-condensing
Physical
Case Size
0.77 x 0.30 x 0.18 Inches (19.5 x 7.62 x 4.5 mm)
Case Material
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Non-Conductive Black Plastic (UL-94V0)
Weight
0.05 Oz (1.4g)
Reliability Specifications
Parameter
Conditions
MTBF
Min.
MIL HDBK 217F, 25°C, Gnd Benign
Shock & Vibration, See Note 5
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Typ.
Max.
3.5
Units
MHours
Meets MIL-STD-202F, IEC68-2-6
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Min.
Typ.
Max.
5 VDC Input
-0.7
9.0
12 VDC Input
-0.7
18.0
1.5 mm From Case For 10 Sec
300
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Model
Number
ACP101E
ACP102E
ACP103E
ACP104E
ACP111E
ACP112E
ACP113E
ACP114E
Input
Voltage (VDC)
Current (mA)
Voltage
Nominal
Range
Full-Load No-Load (VDC)
5
4.5 - 5.5
270
50
5.0
5
4.5 - 5.5
256
50
9.0
5
4.5 - 5.5
260
50
12.0
5
4.5 - 5.5
263
50
15.0
12
10.8 - 13.2
114
20
5.0
12
10.8 - 13.2
127
20
9.0
12
10.8 - 13.2
110
20
12.0
12
10.8 - 13.2
111
20
15.0
Notes:
1. Output load regulation is specified for a load change of 10% to 100%.
2. These units should not be operated with a load under 10% of full load. Operation
at no-load may cause damage to the unit.
3. These converters will operate without external components. However, when measuring output ripple, it is recommended that an external ceramic capacitor be placed
from the +Vout pin to the
Input
Output
-Vout pin. An input capacitor
Vin
Vout
will enhance stability over
Capacitor
Capacitor
temperature and input line
5 VDC
4.7 µF 5 VDC 10.0 µF
variations. Recommended
2.2 µF 9 VDC
4.7 µF
capacitor values are given 12 VDC
in the table at right. For
12 VDC
2.2 µF
applications requiring very
15 VDC
1.0 µF
low output noise levels, a
simple LC filter should be effective.
4. Given for frequency range of 5 to 500 Hz and PSD of 0.0248 g2/Hz.
Tested on X, Y & Z axis for 60 minutes.
5. It is recommended that a fuse be used on the input of a power supply for protection.
See the Model Selection table above for the correct rating.
Output
Current
Current
(mA, Max)
(mA, Min)
200.0
111.0
83.0
67.0
200.0
111.0
83.0
67.0
Load Regulation
20.0
12.0
9.0
7.0
20.0
12.0
9.0
7.0
(% Typ)
(% Max)
12.8
8.3
6.8
6.3
12.8
8.3
6.8
6.3
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
Efficiency
(%, Typ)
Fuse Rating
Slow-Blow
(mA)
74
78
77
76
73
74
76
75
500
500
500
500
200
200
200
200
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
Description
1
+Vin
2
-Vin
5
-Vout
6
+Vout
7
NC
8
NC
14
NC
NC = No Connection
Notes:
MicroPower Direct
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the top of the unit
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]