RBU801M RECTRON THRU SEMICONDUCTOR TECHNICAL SPECIFICATION RBU807M SINGLE-PHASE GLASS PASSIVATED SILICON BRIDGE RECTIFIER VOLTAGE RANGE 50 to 1000 Volts CURRENT 8.0 Amperes FEATURES Low leakage Low forward voltage Mounting position: Any Surge overload rating: 200 amperes peak Ideal for printed circuit boards High forward surge current capability RBU MECHANICAL DATA .880 (22.3) .860 (21.8) * UL listed the recognized component directory, file #E94233 * Epoxy: Device has UL flammability classification 94V-O .140 (3.56) .130 (3.30) .512 (13.0) .740 (18.8) .720 (18.3) .160 (4.1) .140 (3.5) .080 (2.03) .060 (1.52) * * * * * * .085 (2.16) .075 (1.90) .050 (1.27) .040 (1.02) .710 (18.0) .690 (17.5) .100 (2.54) .085 (2.16) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS o Ratings at 25 C ambient temperature unless otherwise specified. .210 (5.33) .190 (4.83) Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%. .080 (2.03) .065 (1.65) .022 (0.56) .018 (0.46) Dimensions in inches and (millimeters) o MAXIMUM RATINGS (At T A = 25 C unless otherwise noted) SYMBOL RATINGS RBU801M RBU802M RBU803M RBU804M RBU805M RBU806M RBU807M UNITS Maximum Recurrent Peak Reverse Voltage VRRM 50 Maximum RMS Bridge Input Voltage VRMS Maximum DC Blocking Voltage VDC o Maximum Average Forward Rectified Output Current at Tc = 75 C Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load 100 200 400 35 70 140 280 420 50 100 200 400 600 800 1000 Volts 560 700 Volts 800 1000 Volts IO 8.0 Amps I FSM 200 Amps Typical Thermal Resistance RθJA 26 (Note 1) R θJC 3.4 T J, T STG -55 to + 150 Operating and Storage Temperature Range 600 0 C/ W 0 C o ELECTRICAL CHARACTERISTICS (At TA = 25 C unless otherwise noted) SYMBOL CHARACTERISTICS RBU801M RBU802M RBU803M RBU804M RBU805M RBU806M RBU807M UNITS VF Maximum Forward Voltage Drop per element at 8.0A DC o Maximum Reverse Current at Rated @T A = 25 C DC Blocking Voltage per element @T A = 125 o C IR NOTE: 1. Units mounted in free air, no heatsink on P.C.B., 0.5x0.5” (12x12mm) copper pads, 0.375” lead length. 2. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”. 1.1 Volts 5.0 uAmps 0.5 mAmps 2013-04 REV: B 8.0 20 INSTANTANEOUS FORWARD CURRENT, (A) AVERAGE FORWARD OUTPUT CURRENT, (A) RATING AND CHARACTERISTICS CURVES ( RBU801M THRU RBU807M ) 6.0 4.0 2.0 10 4.0 1.0 0.4 pulse test per one diode 0 0 50 100 0.1 150 0.4 0.6 O CASE TEMPERATURE, ( C) FIG.1 TYPICAL FORWARD CURRENT DERATING CURVE 28 PEAK FORWARD SURGE CURRENT, (A) 12 8 4 2 4 6 8 10 12 8.3mS Single Half Sine-Wave JEDEC Method 200 160 120 80 40 0 1 14 2 5 10 20 50 AVERAGE RECTIFIER FORWARD CURRENT, (A) NUMBER OF CYCLES AT 60Hz FIG.3 FORWARD DISSIPATION FIG.4 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT INSTANTANEOUS REVERSE CURRENT, (uA) POWER DISSIPATION, (W) 16 0 1.2 240 20 0 1.0 FIG.2 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS sine wave TJ =150 OC 24 0.8 INSTANTANEOUS FORWARD VOLTAGE, (V) 1000 TA = 100 OC 100 10 TA = 25 OC 1.0 0.1 0 20 40 60 80 100 120 140 PERCENT RATED PEAK REVERSE VOLTAGE, (%) FIG.5 TYPICAL REVERSE CHARACTERISTICS 100 RECTRON Attachment information about RBU80XM 1. Internal Circuit 2. Marking on the body Rectron Logo RBU80XM Plant - code UL Logo Year – code (Y: Last digit of year & A:2010,B:2011……) VXXX Week – code (WW:00~52) Part No. Voltage-code 1-------50V 2-------100V 3-------200V 4-------400V 5-------600V 6-------800V 7-------1000V PACKAGING OF DIODE AND BRIDGE RECTIFIERS TUBE PACK PACKAGE PACKING CODE EA PER BOX INNER BOX SIZE CARTON SIZE (mm) (mm) RBU -C 1,000 490*135*110 510*293*131 EA PER CARTON WEIGHT(Kg) 2,000 13.62 1. BOX Packing L W H Code (mm) (mm) (mm) -C 490 135 110 Packing L W H Code (mm) (mm) (mm) -C 510 293 131 2. CARTON DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.