RECTRON SPA2505G

SPA2505G
SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
VOLTAGE 600 Volts CURRENT 25 Amperes
FEATURES
*
*
*
*
*
*
Low leakage
Low forward voltage
Surge overload rating : 300 amperes peak
Mounting position: Any
Ideal for printed circuit boards
High forward surge current capability
R-7
MECHANICAL DATA
* Epoxy: Device has UL flammability classification 94V-O
.065 (1.65)
.96 (24.5)
MIN.
.061 (1.55)
DIA.
.299(7.6)
.291(7.4)
.319(8.1)
.311(7.9)
DIA.
.96 (24.5)
MIN.
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL
SPA2505G
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
600
Volts
Maximum RMS Voltage
VRMS
420
Volts
VDC
600
Volts
IO
25
Amps
I FSM
400
Amps
T J, T STG
-55 to + 175
RATINGS
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
o
at T L = 125 C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Operating and Storage Temperature Range
0
C
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
SYMBOL
SPA2505G
UNITS
VF
1.1
Volts
Maximum Instantaneous Forward Voltage at 25 A DC
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@T A = 25 o C
@T A = 100 o C
NOTES : 1. "Fully ROHS compliant", "100% Sn plating (Pb-free)".
IR
5.0
200
uAmps
2009-11
REV:O
30
20
10
5
2
1
0.5
TC= 25 OC (TYP)
0.2
Pulse Width =
300µs1%
Duty Cycle
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
INSTANTANEOUS REVERSE CURRENT, (µA)
INSTANTANEOUS FORWARD CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( SPA2505G )
1000
100
TA = 100 OC
10
TA = 25 OC
1.0
0.1
0
INSTANTANEOUS FORWARD VOLTAGE, (V)
400
300
200
100
0
1
2
5
10
20
50
100
NUMBER OF CYCLE
FIG.3 SURGE FORWARD CURRENT CAPABILITY
40
60
80
100
120
140
FIG.2 TYPICAL REVERSE CHARACTERISTICS
AVERAGE FORWARD CURRENT, (A)
PEAK FORWARD SURGE CURRENT, (A)
FIG.1 TYPICAL INSTANTANEOUS FORWARD
CHARACTERITICS
8.3ms Single Half Sine-Wave
(JEDED Method)
20
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
50
40
30
20
10
0
15
Single Phase Half Wave
60Hz Inductive or
Resistive Load
35
55
75
95
115
LEAD TEMPERATURE, (OC)
135
155
FIG.4 TYPICAL FORWARD CURRENT
DERATING CURVE
175
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.