SPA2505G SINGLE-PHASE GLASS PASSIVATED SILICON BRIDGE RECTIFIER VOLTAGE 600 Volts CURRENT 25 Amperes FEATURES * * * * * * Low leakage Low forward voltage Surge overload rating : 300 amperes peak Mounting position: Any Ideal for printed circuit boards High forward surge current capability R-7 MECHANICAL DATA * Epoxy: Device has UL flammability classification 94V-O .065 (1.65) .96 (24.5) MIN. .061 (1.55) DIA. .299(7.6) .291(7.4) .319(8.1) .311(7.9) DIA. .96 (24.5) MIN. MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 o C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%. Dimensions in inches and (millimeters) MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) SYMBOL SPA2505G UNITS Maximum Recurrent Peak Reverse Voltage VRRM 600 Volts Maximum RMS Voltage VRMS 420 Volts VDC 600 Volts IO 25 Amps I FSM 400 Amps T J, T STG -55 to + 175 RATINGS Maximum DC Blocking Voltage Maximum Average Forward Rectified Current o at T L = 125 C Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Operating and Storage Temperature Range 0 C ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted) CHARACTERISTICS SYMBOL SPA2505G UNITS VF 1.1 Volts Maximum Instantaneous Forward Voltage at 25 A DC Maximum DC Reverse Current at Rated DC Blocking Voltage @T A = 25 o C @T A = 100 o C NOTES : 1. "Fully ROHS compliant", "100% Sn plating (Pb-free)". IR 5.0 200 uAmps 2009-11 REV:O 30 20 10 5 2 1 0.5 TC= 25 OC (TYP) 0.2 Pulse Width = 300µs1% Duty Cycle 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 INSTANTANEOUS REVERSE CURRENT, (µA) INSTANTANEOUS FORWARD CURRENT, (A) RATING AND CHARACTERISTICS CURVES ( SPA2505G ) 1000 100 TA = 100 OC 10 TA = 25 OC 1.0 0.1 0 INSTANTANEOUS FORWARD VOLTAGE, (V) 400 300 200 100 0 1 2 5 10 20 50 100 NUMBER OF CYCLE FIG.3 SURGE FORWARD CURRENT CAPABILITY 40 60 80 100 120 140 FIG.2 TYPICAL REVERSE CHARACTERISTICS AVERAGE FORWARD CURRENT, (A) PEAK FORWARD SURGE CURRENT, (A) FIG.1 TYPICAL INSTANTANEOUS FORWARD CHARACTERITICS 8.3ms Single Half Sine-Wave (JEDED Method) 20 PERCENT RATED PEAK REVERSE VOLTAGE, (%) 50 40 30 20 10 0 15 Single Phase Half Wave 60Hz Inductive or Resistive Load 35 55 75 95 115 LEAD TEMPERATURE, (OC) 135 155 FIG.4 TYPICAL FORWARD CURRENT DERATING CURVE 175 DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.