CX241 Series • SIP SSR • Ratings to 1.5A @ 280 VAC • SCR output • DC control • Zero-crossing (resistive loads) or random-fire (inductive loads) output PRODUCT SELECTION Control Voltage Zero Crossing Random Fire CX241 CX241R CX241 CX241R 12-280 600 0.1 500 1.5 0.025 40 1.5 0.5 12-280 600 0.1 500 1.5 0.025 40 1.5 0.5 Description CX241 CX241R Control Voltage Range Must Turn On Voltage Must Turn Off Voltage Typycal Input Current @ 5 VDC Nominal Input Impedance Maximum Turn-On Time [msec] Maximum Turn-Off Time [msec] 4-10 VDC 4.0 VDC 1.0 VDC 15 mAdc 300 Ohm 1/2 Cycle 1/2 Cycle 4-10 VDC 4.0 VDC 1.0 VDC 15 mAdc 300 Ohm 0.1 msec 1/2 Cycle 4-10 VDC OUTPUT SPECIFICATIONS (1) Description Operating Voltage (47-63Hz) [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3) Maximum Load Current [Arms](3) Minimum Load Current [Arms] Maximum Surge Current (16.6ms) [Apk] Maximum On-State Voltage Drop @ Rated Current [Vpk] Minimum Power Factor (with Maximum Load) INPUT SPECIFICATIONS (1) GENERAL SPECIFICATIONS Description Dielectric Strength, Input/Output/Base (50/60Hz)(2) Minimum Insulation Resistance (@ 500 VDC) (2) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Encapsulation GENERAL NOTES 1) All parameters at 25°C unless otherwise specified. 2) Dielectric and insulation resistence are measured between input and output 3) Off-State dv/dt test method per EIA/NARM standard RS-443 Parameters 4000 Vrms 10 9 Ohm 8.0 pF -30 to 80˚C -30 to 125˚C 0.4 oz. (11 g) Thermally Conductive Epoxy WIRING DIAGRAM MECHANICAL SPECIFICATIONS .30 (7.6) 0.69 MAX. (17.5) CONTROL + .26 TYP. (6.7) 4 .20 (5.1) 3 .70 (17.8) 1.64 (41.7) LOAD 2 1.10 (27.9) 1 .05 TYP. (1.3) .10 (2.5) .04 (1.0) DIA. (4 PLACES) THERMAL DERATE INFORMATION AGENCY APPROVALS E116950 LR81689 5921 UG Rev. 120414 ANNEX - ENVIROMENTAL INFORMATION