MPD A100UHI

A100UHI Series
Ultra High Isolation, 1W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 1W Output Power
• 12,000 VDC Isolation
• Short Circuit Protection
• High Efficiency
• Compact DIP Case
• Single & Dual Outputs
• Meets EN55022
• 1.0 MH MTBF
Input
Parameter
Input Voltage Range
Input Filter
Conditions
Min.
Typ.
10.8
12.0
Internal Capacitor
Max.
13.2
Units
VDC
Max.
Units
%
%
%
mV P - P
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Conditions
Maximum Capacitive Load
Temperature Coefficient
Output Short Circuit
Min.
Typ.
±2.5
For Vin Change of 1%
Iout = 10% to 100%
See Note 1
A102UHI
A105UHI
±1.2
±15.0
100
100
±100
±0.03
µF
%/ºC
Continuous (Autorecovery)
General
Parameter
Isolation Voltage, Rated
Isolation Resistance
Isolation Capacitance
Conditions
EMI/RFI, See Note 2
EMC Compliance, See Note 2
Switching Frequency
Min.
Typ.
Max.
Units
60 Seconds 12,000
VDC
500 VDC 1,000
M⍀
100 kHz, 0.1V
5
pF
Conducted
CISPR22/EN 55022 Level B
Radiated
CISPR22/EN 55022 Level B
Electrostatic Discharge (ESD)
EN 61000-4-2 Level B 8 kV/6 kV
RF Field Susceptibility
EN 61000-4-3 Level A 10V/m
Electrical Fast Transients/Bursts On Mains
EN 61000-4-4 Level B 2 kV
Surge
EN 61000-4-5 Level B 1 kV
CS
EN 61000-4-6 Level A 10V rms
PFM
EN 61000-4-8 Level A 10A/m
Volt. Dips, Short & Inter. Immunity
EN 61000-4-29 Level B 0 - 40%
100
kHz
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
MicroPower Direct
Physical
292 Page Street
Suite D
Stoughton, MA 02072
USA
Case Size
Case Material
Weight
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
MTBF
Conditions
Min.
Typ.
-40
-55
Free Air Convection
RH, Non-condensing
Ambient
Max.
+85
+125
Units
ºC
ºC
95
%
1.475 x 0.906 x 0.591 Inches (37.0 x 23.0 x 15.0 mm)
Non-Conductive Black Plastic (UL94-V0)
0.81 Oz (23.0g)
Reliability Specifications
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
1,000
Typ.
Max.
Units
kHours
Min.
-0.7
Typ.
Max.
21.0
300
Units
VDC
ºC
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Conditions
1.5 mm From Case For 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Output
Current (mA)
Full-Load No-Load
Voltage
(VDC)
Current
(mA, Max)
Current
(mA, Min)
Efficiency
(%, Typ)
Fuse Rating
Slow-Blow
(mA)
Nominal
Range
A102UHI
12
10.8 - 13.2
106
15
12.0
83
9.0
78
200
A105UHI
12
10.8 - 13.2
106
15
±12.0
±41.6
±5.0
78
200
Notes:
1. When measuring output ripple, it is recommended that an external 2.2 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each
output to common for dual output units.
2. To meet the level B requirements of EN 55022, EN 61000-4-4 (EFT) and EN 61000-4-5 (Surge), use the input circuit shown below.
3. Operation at no-load will not damage these units. However, they may not meet all specifications. It is recommended that the minimum levels shown above be used.
4. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating.
Input Filter Connection
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
1
-Vin
-Vin
11
NC
-Vout
13
-Vout
Common
14
-Vout
Common
16
+Vout
+Vout
26
+Vin
+Vin
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]