RUILON 2R600-4S

ELECTRONICS
Gas
Discharge
Tubes
2R-4S Series
Circuit Protection
System
Specifications are subject to change without notice.
Please refer to http://www.ruilon.com for current information.
Gas Discharge Tubes - 2R-4S Series
GDT introduction:Gas discharge tubes (GDT) use noble gasses enclosed
in ceramic tubes to provide an alternate circuit path for voltage spikes.The
ceramic envelope and with nickel connectors allow for high loads and Ruilon
offers products that function at 20KA,40KA,50KA,60KA,100KA&150KA.
The breakdown voltages of the devices have a wide range (up to 20%
tolerance).Major applications are high frequency telecommunication
lines,stations, security systems,HID and high quality Surge Protection
Devices (SPD).
Features
1. RoHS & HF compliant
2. SMD Structure
3. DC Spark-over voltage: 75~2000V
4. Low Capacitance
5. Agency Recognition : UL/ cUL
6. Operating temperature:-30°C ~ +85°C Storage
temperature:-40°C ~ +115°C
Recommended Applications
1. Cable Modem
2. xDSL
3. Set-Top Box
4. TV sets
5. Power supplier
6. Consumer electronics
Part Number Code
2
R
Series
0
7
DC Line
Voltage
Circuit Protection
System
5
-
4
Dimensions
Specifications are subject to change without notice.
Please refer to http://www.ruilon.com for current information.
Page:1
Gas Discharge Tubes - 2R-4S Series
Electriacl Characteristics
Part No.
DC
Spark-over
Voltage
100V/S
Max.
Impulse
Impulse
Discharge
Life
Current
(10/1000μs)
(8/20μs)
1KV/ 1KV/
1
10
300 A
μS
μs times times
Maximum
Impulse
Breakdown
Voltage
(KA)
Normal
Alternating
Discharge
Current
50Hz
1Sec
Times
Single
9 Cycles
Minimum
Insulation
Resistance
Maximum
Capacitance
(1MHz)
(V)
(GΩ)
(pF)
<150ms
(V)
(V)
(V)
2R075-4S
75±20%
700
800
5
3
300
3
6
52
1
0.5
2R090-4S
90±20%
700
800
5
3
300
3
6
52
1
0.5
2R150-4S
150±20%
600
800
5
3
300
3
6
80
1
0.5
2R230-4S
230±20%
600
700
5
3
300
3
6
150
1
0.5
2R250-4S
250±20%
600
700
5
3
300
3
6
150
1
0.5
2R300-4S
300±20%
600
700
5
3
300
3
6
150
1
0.5
2R350-4S
350±20%
650
800
5
3
300
3
6
150
1
0.5
2R400-4S
400±20%
700
800
5
3
300
3
6
150
1
0.5
2R470-4S
470±20%
800
900
5
3
300
3
6
150
1
0.5
2R600-4S
600±20%
900
1000
5
3
300
3
6
150
1
0.5
2R800-4S
800±20%
1300 1400
3
2
100
2
4
150
1
0.5
2R1000-4S
1000±20%
1500 1600
3
2
100
2
4
150
1
0.5
2R1200-4S
1200±20%
1700 1800
3
2
100
2
4
150
1
0.5
2R1400-4S
1400±20%
1700 1800
3
2
100
2
4
150
1
0.5
2R1500-4S
1500±20%
2000 2100
3
2
100
2
4
150
1
0.5
2R1600-4S
1600±20%
2000 2100
3
2
100
2
4
150
1
0.5
2R1800-4S
1800±20%
2500 2600
3
2
100
2
4
150
1
0.5
2R2000-4S
2000±20%
2700 2600
3
2
100
2
4
150
1
0.5
DC Spark-over Voltage
DC Measuring Voltage
75-90V
50V
150-400V
100V
470-800V
250V
1000-2000V
500V
Circuit Protection
System
(A)
DC
Holdover
Voltage
Specifications are subject to change without notice.
Please refer to http://www.ruilon.com for current information.
Page:2
Gas Discharge Tubes - 2R-4S Series
Dimension
Unit:mm
4.0 ± 0.2
4.2 ± 0.2
0.5 ± 0.1
Recommended Pad Size
Unit:mm
3.5
5.0
1.3
Packaging Taping
Unit:mm
P0
D
E
F
P
W
t
K
Circuit Protection
System
Specifications are subject to change without notice.
Please refer to http://www.ruilon.com for current information.
Page:3
Gas Discharge Tubes - 2R-4S Series
Quantity: 900pcs per reel (13”)
Unit:mm
Item
P
PO
W
F
E
D
K
t
Spec.
12.0
4.0
16.0
7.5
1.75
Φ1.55
4.6
0.5
Tolerance
±0.1
±0.1
±0.3
±0.1
±0.1
±0.05
+0.2,-0.1
±0.05
.
330 ± 4.0
>1.5
100typ
.
18. typ
Warehouse Storage Conditions of Products
· Storage Conditions:
1. Storage Temperature: -10°C~+40°C
2. Relative Humidity:≤75%RH
3. Keep away from corrosive atmosphere and sunlight.
· Period of Storage: 1 year
Circuit Protection
System
Specifications are subject to change without notice.
Please refer to http://www.ruilon.com for current information.
Page:4
RuiLongYuan Electronics Co., Ltd.
· Reproducing and modifying information of the document is prohibited without permission from
Ruilongyuan International Inc.
· Ruilongyuan International Inc. reserves the rights to make changes of the content herein the document anytime
without notification. Please refer to our website for the latest document.
· Ruilongyuan International Inc. disclaims any and all liability arising out of the application or use of any product
including damages incidentally and consequentially occurred.
· Ruilongyuan International Inc. does not assume any and all implied warranties, including warranties of fitness
for particular purpose, non-infringement and merchantability.
· Applications shown on the herein document are examples of standard use and operation. Customers are responsible
in comprehending the suitable use in particular applications.Ruilongyuan International Inc. makes no representation or
warranty that such applications will be suitable for the specifed use without further testing or modifcation.
· The products shown herein are not designed and authorized for equipments requiring high level of reliability or relating to
human life and for any applications concerning life-saving or life-sustaining, such as medical instruments, transportation
equipment,aerospace machinery et cetera. Customers using or selling these products for use in such applications do so at
their own risk and agree to fullyindemnify Ruilongyuan International Inc. for any damages resulting from such improper use or
sale.
Tel: +86-755-8290 8296
Circuit Protection
System
Fax: +86-755-8290 8002
E-mail: [email protected]
Specifications are subject to change without notice.
Please refer to http://www.ruilon.com for current information.
Page:5