58 Series - Relay Interface Modules 5 A 58.34 - Relay interface modules for use with PLC systems, 27mm wide - AC and DC versions available - Supply status indication or coil protection module provided - Identification label - 35 mm rail (EN 50022) mounting - 4 pole - 35 mm rail (EN 50022) mounting 25.9 12 41 11 31 10 21 9 11 COM 12 41 11 31 10 21 9 11 COM 8 44 7 34 6 24 5 14 NO 8 44 7 34 6 24 5 14 NO 4 42 3 32 2 22 1 12 NC 4 42 3 32 2 22 1 12 NC 14 A2 13 A1 14 A2 13 A1 — + 17.5 17.5 27.5 76 27 73 32 COIL AC COIL DC Contact specifications Contact configuration 4 CO (4PDT) Rated current/Maximum peak current A 5/10 Rated voltage/Maximum switching voltage V AC Rated load in AC1 250/250 VA Rated load in AC15 (230 VAC) 1,250 VA Single phase motor rating (230 VAC) Breaking capacity in DC1: 30/110/220V Minimum switching load 250 kW/HP 0.125/0.2 A 5/0.25/0.12 mW (V/mA) 300 (5/5) Standard contact material AgNi Coil specifications Nominal voltage (UN) V AC (50/60 Hz) 12 - 24 - 48 - 110 - 120 - 230 V DC Rated power AC/DC 12 - 24 - 48 VA (50 Hz)/W Operating range 1.5/1 AC (50 Hz) (0.8…1.1)UN DC (0.8…1.1)UN Holding voltage AC/DC 0.8 UN/0.5 UN Must drop-out voltage AC/DC 0.2 UN/0.1 UN Technical data Mechanical life AC/DC cycles 20 · 106/50 · 106 Electrical life at rated load AC1 cycles 150 · 103 Operate/release time (bounce included) ms 10/20 Insulation according to EN 61810-5 3.6 kV/2 Insulation between coil and contacts (1.2/50µs) kV Dielectric strenght between open contacts Ambient temperature range 3.6 V AC 1,000 °C –40…+70 Protection category Approvals (relay): (according to type) 46 IP 20 GOST RINA ® C US 58 Series - Relay Interface Modules 5 A ORDERING INFORMATION Example: a 58 series 35 mm rail (EN 55022) mounting interface module, 4 CO (4PDT), 24 V DC coil with green LED + diode. A 5 8 . 3 4 . 9 . 0 2 4 . 0 Series Type 3 = 35mm rail mount No. of poles 4 = 4 CO (4PDT), 5 A B C D 0 5 0 A: Contact material 0 = AgNi Standard D: Special applications 0 = Standard B: Contact circuit 0 = Standard C: Options 50 = Standard DC: LED + diode (polarity +A1) 60 = Standard AC: LED + varistor Coil version 8 = AC (50/60 Hz) 9 = DC Coil voltage see coil specifications TECHNICAL DATA INSULATION INSULATION according to EN 61810-5 insulation rated voltage rated impulse withstand voltage V 250 kV 3.6 pollution degree 2 overvoltage category III IMMUNITY CONDUCTED DISTURBANCE IMMUNITY BURST (according to EN 61000-4-4) level 4 (4kV) SURGE (according to EN 61000-4-5) level 4 (4kV) OTHER DATA VIBRATION RESISTANCE (10…55Hz): NO/NC POWER LOST IN THE ENVIRONMENT g/g without contact current W with rated current W 6/6 1 2.6 CONTACT SPECIFICATIONS F 58 10 10 7 DC BREAKING CURRENT (A) CYCLES 10 H 58 6 5 0 8 4 12 LOAD RATED CURRENT (A) Contact life vs AC1 load. 16 20 10 6 A 4 B C D 2 1 0.2 0.1 20 60 100 140 180 220 DC VOLTAGE (V) Breaking capacity for DC1 load. A = load applied to 1 contact; B = load applied to 2 contacts in series C = load applied to 3 contacts in series; D = load applied to 4 contacts in series • When switching a resistive load (DC1) having voltage and current values under the curve the expected electrical life is ≥ 100·103 cycles. • In case of DC13 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC1 load. Note: the release time of load will be increase. 47 58 Series - Relay Interface Modules 5 A COIL SPECIFICATIONS DC VERSION DATA AC VERSION DATA Nominal voltage UN V 12 24 48 110 120 230 Coil code 8.012 8.024 8.048 8.110 8.120 8.230 Operating range Umin V 9.6 19.2 38.4 88 96 184 Umax V 13.2 26.4 52.8 121 132 253 Resistance Rated coil absorption R I at UN (50Hz) Ω mA 50 117 190 58.3 770 29.2 4,000 12.7 4,700 11.3 17,000 6.1 Nominal voltage UN V 12 24 48 Coil code Umin V 9.6 19.2 38.4 9.012 9.024 9.048 R 58 AC R 58 DC U 2.0 UN U 2.0 UN 1.5 1.5 Resistance Rated coil absorption R I at UN Ω mA 140 86 600 40 2,400 20 Umax V 13.2 26.4 52.8 1 1 1.0 Operating range 1.0 2 2 0.5 -20 0 20 40 0.5 -20 60 AMBIENT TEMPERATURE (°C) 0 20 40 60 AMBIENT TEMPERATURE (°C) Operating range (AC type) vs ambient temperature. 1 - Max coil voltage permitted 2 - Min pick-up voltage with coil at ambient temperature Operating range (DC type) vs ambient temperature. 1 - Max coil voltage permitted 2 - Min pick-up voltage with coil at ambient temperature ACCESSORIES 6-way jumper link for 58 series 094.06 3.3 135 5.1 7 094.06 10.3 - RATED VALUES: 10 A - 250 V 0.75 48 26.25 27 27 27 26.25