ETC 5.8349E+11

58 Series - Relay Interface Modules 5 A
58.34
- Relay interface modules for use with
PLC systems, 27mm wide
- AC and DC versions available
- Supply status indication or coil protection
module provided
- Identification label
- 35 mm rail (EN 50022) mounting
- 4 pole
- 35 mm rail (EN 50022) mounting
25.9
12
41
11
31
10
21
9
11
COM
12
41
11
31
10
21
9
11
COM
8
44
7
34
6
24
5
14
NO
8
44
7
34
6
24
5
14
NO
4
42
3
32
2
22
1
12
NC
4
42
3
32
2
22
1
12
NC
14
A2
13
A1
14
A2
13
A1
—
+
17.5
17.5
27.5
76
27
73
32
COIL
AC
COIL
DC
Contact specifications
Contact configuration
4 CO (4PDT)
Rated current/Maximum peak current
A
5/10
Rated voltage/Maximum switching voltage V AC
Rated load in AC1
250/250
VA
Rated load in AC15 (230 VAC)
1,250
VA
Single phase motor rating (230 VAC)
Breaking capacity in DC1: 30/110/220V
Minimum switching load
250
kW/HP
0.125/0.2
A
5/0.25/0.12
mW (V/mA)
300 (5/5)
Standard contact material
AgNi
Coil specifications
Nominal voltage (UN)
V AC (50/60 Hz)
12 - 24 - 48 - 110 - 120 - 230
V DC
Rated power AC/DC
12 - 24 - 48
VA (50 Hz)/W
Operating range
1.5/1
AC (50 Hz)
(0.8…1.1)UN
DC
(0.8…1.1)UN
Holding voltage
AC/DC
0.8 UN/0.5 UN
Must drop-out voltage
AC/DC
0.2 UN/0.1 UN
Technical data
Mechanical life AC/DC
cycles
20 · 106/50 · 106
Electrical life at rated load AC1
cycles
150 · 103
Operate/release time (bounce included)
ms
10/20
Insulation according to EN 61810-5
3.6 kV/2
Insulation between coil and contacts (1.2/50µs) kV
Dielectric strenght between open contacts
Ambient temperature range
3.6
V AC
1,000
°C
–40…+70
Protection category
Approvals (relay): (according to type)
46
IP 20
GOST
RINA
®
C
US
58 Series - Relay Interface Modules 5 A
ORDERING INFORMATION
Example: a 58 series 35 mm rail (EN 55022) mounting interface module, 4 CO (4PDT), 24 V DC coil with green LED + diode.
A
5 8 . 3
4 . 9 . 0 2 4 . 0
Series
Type
3 = 35mm rail mount
No. of poles
4 = 4 CO (4PDT), 5 A
B
C
D
0
5
0
A: Contact material
0 = AgNi Standard
D: Special applications
0 = Standard
B: Contact circuit
0 = Standard
C: Options
50 = Standard DC: LED + diode
(polarity +A1)
60 = Standard AC: LED + varistor
Coil version
8 = AC (50/60 Hz)
9 = DC
Coil voltage
see coil specifications
TECHNICAL DATA
INSULATION
INSULATION according to EN 61810-5
insulation rated voltage
rated impulse withstand voltage
V
250
kV
3.6
pollution degree
2
overvoltage category
III
IMMUNITY
CONDUCTED DISTURBANCE IMMUNITY
BURST (according to EN 61000-4-4) level 4 (4kV)
SURGE (according to EN 61000-4-5) level 4 (4kV)
OTHER DATA
VIBRATION RESISTANCE (10…55Hz): NO/NC
POWER LOST IN THE ENVIRONMENT
g/g
without contact current W
with rated current W
6/6
1
2.6
CONTACT SPECIFICATIONS
F 58
10
10
7
DC BREAKING CURRENT (A)
CYCLES
10
H 58
6
5
0
8
4
12
LOAD RATED CURRENT (A)
Contact life vs AC1 load.
16
20
10
6 A
4
B
C
D
2
1
0.2
0.1
20
60
100
140
180
220
DC VOLTAGE (V)
Breaking capacity for DC1 load.
A = load applied to 1 contact;
B = load applied to 2 contacts in series
C = load applied to 3 contacts in series;
D = load applied to 4 contacts in series
• When switching a resistive load (DC1) having voltage and
current values under the curve the expected electrical life is
≥ 100·103 cycles.
• In case of DC13 loads the connection of a diode in parallel with
the load will permit the same electrical life as for a DC1 load.
Note: the release time of load will be increase.
47
58 Series - Relay Interface Modules 5 A
COIL SPECIFICATIONS
DC VERSION DATA
AC VERSION DATA
Nominal
voltage
UN
V
12
24
48
110
120
230
Coil
code
8.012
8.024
8.048
8.110
8.120
8.230
Operating range
Umin
V
9.6
19.2
38.4
88
96
184
Umax
V
13.2
26.4
52.8
121
132
253
Resistance Rated coil
absorption
R
I at UN (50Hz)
Ω
mA
50
117
190
58.3
770
29.2
4,000
12.7
4,700
11.3
17,000
6.1
Nominal
voltage
UN
V
12
24
48
Coil
code
Umin
V
9.6
19.2
38.4
9.012
9.024
9.048
R 58 AC
R 58 DC
U 2.0
UN
U 2.0
UN
1.5
1.5
Resistance Rated coil
absorption
R
I at UN
Ω
mA
140
86
600
40
2,400
20
Umax
V
13.2
26.4
52.8
1
1
1.0
Operating range
1.0
2
2
0.5
-20
0
20
40
0.5
-20
60
AMBIENT TEMPERATURE (°C)
0
20
40
60
AMBIENT TEMPERATURE (°C)
Operating range (AC type) vs ambient temperature.
1 - Max coil voltage permitted
2 - Min pick-up voltage with coil at ambient temperature
Operating range (DC type) vs ambient temperature.
1 - Max coil voltage permitted
2 - Min pick-up voltage with coil at ambient temperature
ACCESSORIES
6-way jumper link for 58 series
094.06
3.3
135
5.1
7
094.06
10.3
- RATED VALUES: 10 A - 250 V
0.75
48
26.25
27
27
27
26.25