ETC 5634-8230

56 Series
Miniature Power Relays 12 A
A range of miniature power relays, with 2 or 4 CO contact
Features include:
• Plug-in (FASTON 187) mount versions available
• AC or DC coils
• Dual-function lockable test button with mechanical flag indicator, top or rear mount
flange, top or rear DIN rail mount options available
• Module facilities: low consumption LED indicator and surge supression diode options
• Sockets and accessories: see 96 and 99.01 series
• Approvals (according to type): BBJ, CSA, IMQ, NEMKO, SEMKO, SEV, cUL, UTE, VDE
CERAMICS INDUSTRY
MACHINES
PACKING
MACHINES
COFFEE
MACHINES
VOLTAGE
STABILIZERS
AUTOMATIC
GATES
INDUSTRIAL
APPLIANCES
ELEVAT
TOOLING
MACHINES
ELECTRIC
MOTOR LOADS
U.P.S.
IN
OUT
3
57
56 Series
Miniature Power Relays 12 A
56.32
56.34
C
C
MINIATURE POWER RELAYS 4 CO (4PDT) 12 A
TYPE 56.34 plug-in
- Tin plated brass connections:
FASTON 187 (4.8 x 0.5 mm) for plug-in versions
- Standard contact material: AgNi
- Options: see coding table page 62
- Ordering information: see page 62
MINIATURE POWER RELAYS 2 CO (DPDT) 12 A
TYPE 56.32 plug-in
- Lockable test button
- Tin plated brass connections:
FASTON 187 (4.8 x 0.5 mm) for plug-in versions
- Standard contact material: AgNi
Options:
TYPE 56.32 - 0300 2 NO (DPST-NO) 12 A
TYPE 56.42 - 0300 2 NO (DPST-NO) 12 A
- 1.5 mm gap between open contacts (AC version only)
- Options: see coding table page 62
- Ordering information: see page 62
5.3 10 5.3
6.55 7.25 5.9 7.9
41
27.6
35.2
27.5
A
A
A
35
20.6
35
27.5
6.55 7.25 5.9 4.7 3.2
5.5 10
10
10 5.5
6.55 7.25 5.9 4.7 3.2
A = 6.4 mm
1
3
2
5
8
7
56.32
58
6
4
3
4
5
7
6
A = 6.4 mm
1
5
9
8
56.32 - 0300
2
6
10
13
3
7
11
14
4
8
12
56 Series
Miniature Power Relays 12 A
TECHNICAL DATA
DIELECTRIC STRENGTH
tested at leakage current
≤ 10 mA for 1 min at 50 Hz
SURGE TEST (1.2/50 µs) between coil and contacts
ISOLATION RESISTANCE
ISOLATION GROUP
MAXIMUM SWITCHING FREQUENCY
- without load
- at rated load
AMBIENT TEMPERATURE
MECHANICAL LIFE
between coil and contact
between open contact
between adjacent contact
between frame and live parts
4,000 V
≥ 20 · 103 MΩ
C 250
2,000 V
1,000 V
2,000 V
relay without external ground
36,000 cycles/h
600 cycles/h
(–40 ... +70)°C
20 · 106 cycles version AC
50 · 106 cycles version DC
IP 40
4 CO
≤ 15 ms (including contact bounce)
≤ 15 ms (including contact bounce)
continuous
PROTECTION CATEGORY OF ENCLOSURES
OPERATE AND RELEASE TIME
- pick-up time (0 to UN)
- drop-out time (UN to 0)
TYPE OF DUTY
DIELECTRIC TEST
2 NO
≤ 20 ms (including contact bounce)
—
2
TYPE OF RELAY
all-or-nothing
F 56
CONTACT SPECIFICATIONS
10
12 A
MAXIMUM PEAK CURRENT
20 A
NOMINAL RATE IN AC1
3,000 VA
NOMINAL RATE IN AC15
500 VA
RATED VOLTAGE
250 V AC
MAXIMUM SWITCHING VOLTAGE
400 V AC
BREAKING CAPACITY IN DC1
see diagram H56
SINGLE PHASE HP MOTOR RATING AT 250 V
0.55 kW; 0.7 HP
CONTACT RESISTANCE: - initial
≤ 50 mΩ
MINIMUM SWITCHING LOAD
500 mW (10 V/5 mA)
STANDARD CONTACT MATERIAL
AgNi
CYCLES
RATED CURRENT
7
106
105
0
0.5
1
1.5
2
2.5
3 KVA
LOAD
K 56
H 56
K
1
10
6
4
2
1
0.6
0.4
A
0.2
k REDUCTION FACTOR
MAX SWIYCHING CURRENT (A)
20
0.8
K
0.6
0.4
1
0.1
20
60
100
140
180
0.8
0.6
B
220
0.4
0.2
COS ϕ
VOLTAGE V (DC)
Breaking capacity for DC1 load at 600 cycles/h. Load applied to 1 contact.
A = types 56.32 - 0300 and 56.42 - 0300
B = other types
Load reduction factor vs cos ϕ.
59
56 Series
Miniature Power Relays 12 A
COIL SPECIFICATIONS
VERSIONS:
AC - alternating current 50/60 Hz
DC - direct current
AC - 2 CO (DPDT)
DC - 2 CO (DPDT)
AC - 4 CO (4PDT)
1.5 VA
1W
2 VA
1.3 W
OPERATING RANGE
(0.8 ... 1.1) UN
(0.85 ... 1.1) UN
(0.8 ... 1.1) UN
(0.85 ... 1.1) UN
HOLDING VOLTAGE
≤ 0.8 UN
≤ 0.6 UN
≤ 0.8 UN
≤ 0.6 UN
MUST DROP-OUT VOLTAGE
≥ 0.2 UN
≥ 0.1 UN
≥ 0.2 UN
≥ 0.1 UN
150 A
200 A
125 A
180 A
F (+155°C)
F (+155°C)
F (+155°C)
F (+155°C)
50°C/W
50°C/W
35°C/W
35°C/W
RATED POWER
NOMINAL MAGNETOMOTIVE FORCE
THERMAL INSULATION CLASS OF WIRE
THERMAL RESISTANCE
CONDUCTED DISTURBANCE IMMUNITY BURST (acc. to EN 61000 - 4 - 4)
SURGE (acc. to EN 61000 - 4 - 5)
Operating range
Resistance Nominal coil
absorption
level 4 (4 kV)
Rated
voltage
Operating range
Resistance
Nominal coil
absorption
UN
Umin
Umax
R
UN 50 Hz I
UN
Umin
Umax
R
I
V
V
V
Ω
mA
V
V
V
Ω
mA
6
4.8
6.6
5.1
6.6
12
9.6
24
19.2
48
38.4
6
150
230
13.2
50
117
26.4
190
58.3
52.8
770
29.2
48
40.8
52.8
2,400
20
51
66
4,000
15
121
12,500
12
10.2
13.2
140
86
24
20.4
26.4
600
40
60
48
66
1,200
23.3
60
110
88
121
3,940
12.7
110
120
96
132
4,700
10.8
230
184
253
17,000
6.1
240
192
264
19,100
5.8
Rated
voltage
44
12
Operating range
93.5
8.8
DC VERSION DATA (4 CO/4PDT)
R values relate to +20°C. Tolerance of R and I values: ± 10%.
AC VERSION DATA (4 CO/4PDT)
R values relate to +20°C. Tolerance of R and I values: ± 10%.
60
level 4 (4 kV)
DC VERSION DATA (2 CO/DPDT)
R values relate to +20°C. Tolerance of R and I values: ± 10%.
AC VERSION DATA (2 CO/DPDT)
R values relate to +20°C. Tolerance of R and I values: ± 10%.
Rated
voltage
DC - 4 CO (4PDT)
Resistance
Nominal coil
absorption
Rated
voltage
Operating range
Resistance
Nominal coil
absorption
UN
Umin
Umax
R
UN 50 Hz I
UN
Umin
Umax
R
I
V
V
V
Ω
mA
V
V
V
Ω
mA
6
4.8
6.6
6
290
6
5.1
6.6
33
182
12
9.6
13.2
23
150
12
10.2
13.2
125
92
24
19.2
26.4
80
75
24
20.4
26.4
500
46
48
38.4
52.8
380
36
48
40.8
52.8
1,800
25
60
51
66
3,000
20
121
10,500
10
60
48
66
600
110
88
121
1,900
16.5
26
120
96
132
2,600
13.4
230
184
253
8,000
7.2
240
192
264
10,500
6.9
110
93.5
56 Series
Miniature Power Relays 12 A
COIL SPECIFICATIONS
S 56/1
R 56
Umin
70
TEMPERATURE RISE “∆t” (°C)
UN
1
0.9
0.8
0.7
0.6
0.5
60
50
1.1 UN
40
UN
30
0.85 UN
20
10
-40
-30
-20
-10
0
10
20
30
40
50
60
70
0
10
AMBIENT TEMPERATURE (°C)
20
30
DC coil min pick-up voltage vs ambient temperature.
Umin = pick-up voltage
UN = rated voltage
60 min
S 56/3
70
70
60
60
50
1.1 UN
40
UN
30
0.8 UN
20
TEMPERATURE RISE “∆t” (°C)
TEMPERATURE RISE “∆t” (°C)
50
Temperature rise "∆t " vs applied voltage.
DC coils 2 CO (DPDT) and 4 CO (4PDT).
S 56/2
10
50
40
1.1 UN
30
UN
20
0.8 UN
10
0
0
10
20
30
40
50
10
60 min
20
30
40
50
60 min
HEATING TIME
HEATING TIME
Temperature rise "∆t " vs applied voltage.
AC 60 Hz coils 4 CO (4PDT).
Temperature rise "∆t " vs applied voltage.
AC 50 Hz coils 4 CO (4PDT).
S 56/5
S 56/4
70
70
60
60
50
1.1 UN
40
UN
30
0.8 UN
20
10
TEMPERATURE RISE “∆t” (°C)
TEMPERATURE RISE “∆t” (°C)
40
HEATING TIME
50
40
1.1 UN
30
UN
20
0.8 UN
10
0
0
10
20
30
40
HEATING TIME
Temperature rise "∆t " vs applied voltage.
AC 50 Hz coils 2 CO (DPDT).
50
60 min
10
20
30
40
50
60 min
HEATING TIME
Temperature rise "∆t " vs applied voltage.
AC 60 Hz coils 2 CO (DPDT).
61
56 Series
Miniature Power Relays 12 A
ORDERING INFORMATION
Example: a 56 series plug-in relay, 2 CO (DPDT) contacts, coil rated 12 V DC with a lockable test button and mechanical indicator.
5 6
2
3
9
Coil version
No. of poles
2 = 2 CO(DPDT) 3 = DC diode in parallel
to the coil (positive to
4 = 4 CO (4PDT)
pin 7) for 2 CO only
8 = AC (50/60 Hz)
9 = DC
Series
0
0 1 2
Type
3 = Plug-in
Contact material
and contact circuit
00 = Standard
03 = NO ≥ 1,5 mm**
20 = AgCdO
40 = AgSnO2
Coil voltage
006 =
6V
012 = 12 V
024 = 24 V
048 = 48 V
060 = 60 V
110 = 110 V
120 = 120 V AC only
230 = 230 V AC only
240 = 240 V AC only
* for 56.32 (2 CO) only
# for 56.32 (2 CO) and 56.32 (2 NO - DPDT-NO)
** for 56.32 (2 CO) AC only
0
0
4
Options
00 = Standard
05 = Top flange mount
06 = Rear flange mount
07 = Top DIN rail mount (4 CO only)
08 = Rear DIN rail mount (4 CO only)
10 = Lockable test button
20 = Mechanical indicator *
30 = LED (AC only) #
40 = Lockable test button + mechanical indicator *
50 = Lockable test button + LED (AC only) #
54 = Lockable test button + LED (AC only)
+ mechanical indicator *
60 = LED + diode (positive to pin A2/14,
DC non standard polarity) #
70 = Lockable test button + LED + diode
(positive to pin A2/14,
DC non standard polarity) #
74 = Lockable test button + LED + diode
(positive to pin A2/14,
DC non standard polarity) +
mechanical indicator*
80 = LED + diode (polarity positive to pin 7, DC)#
90 = Lockable test button + LED
(polarity positive to pin 7, DC) *
94 = Lockable test button + LED + mechanical
indicator (polarity positive to pin 7, DC) *
OPTIONS
7
8
Coil version= 3
37.5
7
8
Option= 0030
7
8
7
8
Option= 0080 - 0090
Option= 0060 - 0070
REAR MOUNT FLANGE
(0006)
TOP MOUNT FLANGE
(0005)
41.9
REAR DIN MOUNT RAIL
(0008)
(4 CO - 4PDT only)
62
LOCKABLE TEST BUTTON +
MECHANICAL FLAG
INDICATOR (0040)
(2 CO - DPDT only)
96 Series - Sockets and Accessories
for 56 Series Relays
•
•
•
•
•
A range of sockets and accessories for the 56 series relays
PCB mount, screw terminal connection, panel and DIN rail 46277 mount versions available
Can be used with supply status indication and coil protection modules
Flammability in accordance with UL 94
Approvals (according to type): BBJ, CS - IMQ, cULus
63
96 Series - Sockets and Accessories
for 56 Series Relays
96.74
96.12
®
®
C V
US
C
C
SCREW TERMINAL SOCKETS
TYPE 96.72 for type 56.32
TYPE 96.74 for type 56.34
Accessories: TYPE 094.71 retaining clip for socket 96.72
Accessories: TYPE 096.71 retaining clip for socket 96.74
Accessories: TYPE 99.01 module facilities
P.C.B. SOCKETS
TYPE 96.12 for type 56.32
TYPE 96.14 for type 56.34
Accessories: TYPE 094.51 retaining clip
CHARACTERISTICS
- LOAD: 12 A 250 V
- ISOLATION RESISTANCE: ≥ 103 MΩ
- DIELECTRIC STRENGTH: ≥ 2 kV AC
- MATERIAL: self-extinguishing PPEm (V1)
- CONNECTIONS: Cu Zn 33 tin plated
CHARACTERISTICS
- LOAD: 12 A 250 V
- ISOLATION RESISTANCE: ≥ 103 MΩ
- DIELECTRIC STRENGTH: ≥ 2 kV AC
- MATERIAL: self-extinguishing PPEm (V1)
- CONNECTIONS: Cu Zn 33 nickel plated + Cu Sn 8
- PROTECTION CATEGOR: IP 20
- Non removable pozidrive slotted terminal screws.
- Identification tag.
3.5
4
5
14.5
19.4
41.5
29.5
22
2
12
1
NC
24
4
14
3
NO
78
35
25
29.5
29.5
5
21.5
US
23.6
16
21.5
10
10
5
41.5
10
10
27
3
33.5
7.25 5.9 4.7
3.5
4
19.4
29.5
5
2.5
29.5
29.5
2.5
7.25 5.9 4.7
27
11
5
COM
A2
8
A1
7
COIL
42
4
32
3
22
2
12
1
NC
44
8
34
7
24
6
14
5
NO
41
12
31
11
21
10
11
9
30
5
23.6
78
35
14.2
21
6
6.5
46
64
COM
27
33.5
A2
14
A1
13
COIL