Time control technique Time relay AA 7562, release delay minitimer 0232906 • • • • • • Function diagram According to IEC/EN 60 812-1 Delay up to 180 s Repeat accuracy < ± 5 % without auxiliary voltage 1 changeover contact delayed, 1 changeover contact without delay Width 45 mm Approvals and marking Deutschland Notes The mounting distance should not be smaller than 8 mm. Technical data Time circuit Time ranges: Time setting: Repeat accuracy: Min. transition time: Temperature influence: Circuit diagram A1 15 21 15 A1 0,2 ... 30 s 0,2 ... 180 s infinitely ≤ ± 5 % of the final range value 25 ms 0,5 % / K under certain circumstances, variation and temperature errors can be added. 21 Input A2 18 16 24 16 18 22 24 A2 22 M2533_a Nominal voltage UN: Voltage range: AA 7562.32 Nominal consumption: Nominal frequency: AC 24, 42, 110, 127, 230, 240 V 50 or 60 Hz DC 24 ... 220 V AC 0,85 ... 1,1 U N DC 0,8 ... 1,1 U N Initial position Active position 22 VA 7 VA 5,5 W 5,5 W 50 Hz Output Contacts AA 7562.32: 1 changeover contact, without delay 1 changeover contact, delayed Operating time of contacts: < 50 ms Release time of contacts: < 25 ms Thermal current I th: 4A Nominal breaking capacity AC 110 V AC 230 V cos ϕ 1 ... 0,7: 2A 2A cos ϕ 0,4: 1A 1A DC 110 V DC 220 V ohmic: 0,25 A 0,25 A inductive: 0,03 A 0,02 A Electrical life: 1,2 x 10 6 switching cycles 1 500 switches/h at 30 % of the switching capacity 0,8 x 10 6 switching cycles 1 000 switches/h at 50 % of the switching capacity 0,3 x 10 6 switching cycles 500 switches/h at 100 % of the switching capacity All technical data in this list relate to the state at the moment of edition. We reserve the right for technical improvements and changes at any time. 1 AA 7562 / 19.03.08 e Technical data Permissible switching frequency: Short circuit strength max. fuse rating: Mechanical life: 1 500 switching cycles / h 2 A gL IEC/EN 60 947-5-1 > 3 x 10 6 switching cycles General data Operating mode: Temperature range: Clearance and creepage distances overvoltage category / contamination level: EMC Electrostatic discharge: HF-irradiation: Fast transients: Surge voltages between wires for power supply: between wire and ground: HF-wire guided: Interference suppression: Degree of protection Housing: Terminals: Housing: Vibration resistance: Climate resistance: Terminal arrangement: Terminal designation: Wire connection: Wire fixing: Mounting: Weight: Continuous operation - 10 ... + 55 °C 4 kV / 2 8 kV (air) 10 V/m 2 kV 1 kV 2 kV 10 V Limit value class IEC 60 664-1 IEC/EN 61 000-4-2 IEC/EN 61 000-4-3 IEC/EN 61 000-4-4 IEC/EN IEC/EN IEC/EN B 61 000-4-5 61 000-4-5 61 000-4-6 EN 55 011 IP 40 IEC/EN 60 529 IP 10 IEC/EN 60 529 Thermoplast with V0-behaviour according to UL subject 94 Amplitude 0,35 mm frequency 10...55Hz,IEC/EN 60 068-2-6 The device is only to be used in dry rooms, in closed switch cabinets or switch boxes DIN 46 199-5 EN 50 005 2 x 2,5 mm 2 solid or 2 x 1,5 mm2 stranded wire with sleeve DIN 46 228-1/-2/-3/-4 Flat terminals with self-lifting clamping piece IEC/EN 60 999-1 DIN rail IEC/EN 60 715 270 g AC-version 310 g DC-version Dimensions Widht x height x depth: 45 x 77 x 124 mm Standard type AA 7562.32 AC 230 V 50 Hz 0,2 ... 30 s Article number: 0009431 stock item • Output: 1 changeover contact, instantaneous 1 changeover contact, delayed • Nominal voltage U N: AC 230 V • Time range: 0,2 ... 30 s • Width: 45 mm Variant AA 7562.32/001: DC-version, as option for: DC 12, 24, 42, 48, 110, 220 V, DC 12 ... 220 V Ordering example for variant AA 7562 .32 /001 DC 24 V 180 s Time range Nominal voltage Variant, if required Contacts Type E. DOLD & SÖHNE KG • D-78114 Furtwangen • e-mail: [email protected] • internet: http://www.dold.com PO Box 1251 • Telephone (+49) 77 23 / 654-0 • Telefax (+49) 77 23 / 654-356 2 AA 7562 / 19.03.08 e