Monitoring Relays 3-Phase, 3-Phase+N, Multi-function Types DPC01, PPC01 DPC01 PPC01 Product Description • 3-phase over and under voltage, phase sequence, phase loss and asymmetry monitoring relay • Detect when all 3 phases are present and have the correct sequence • Detect if all the 3-phase-phase or phase-neutral voltages are within the set limits • Detect if asymmetry is below set value • Separately adjustable setpoints • Separately adjustable delay functions (0.1 to 30 s) • Output: 2 x 8 A relay SPDT NE or ND (selectable) • For mounting on DIN-rail in accordance with DIN/EN 50 022 (DPC01) or plug-in module (PPC01) • 45 mm Euronorm housing (DPC01) or 36 mm plug-in module (PPC01) • LED indication for relay, alarm and power supply ON Ordering Key DPC 01 D M48 adjustable set points) with built-in time delay function. Supply ranges from 208 to 480 VAC covered by two multivoltage relays. Housing Function Type Item number Output Power supply Mounting Output Supply: 208 to 240 VAC Supply: 380 to 480 VAC DIN-rail Plug-in 2 x SPDT 2 x SPDT DPC 01 D M23 PPC 01 D M23 DPC 01 D M48 PPC 01 D M48 3-phase or 3-phase+neutral line voltage monitoring relay for phase sequence, phase loss, asymmetry, over and under voltage (separately Type Selection Input Specifications Output Specifications Input L1, L2, L3, N Output Rated insulation voltage Contact ratings (AgSnO2) Resistive loads AC 1 DC 12 Small inductive loads AC 15 DC 13 Mechanical life Electrical life Measuring ranges 208 to 240 VAC 380 to 480 VAC (DPC01DM48) 380 to 415 VAC (PPC01DM48) Ranges Upper level Lower level Asymmetry Tolerance DPC01: Terminals L1, L2, L3, N PPC01: Terminals 5, 6, 7, 11 Measure on own supply 177 to 275 VAC 323 to 550 VAC 323 to 475 VAC +2 to +22% of the nominal voltage -22 to -2% of the nominal voltage 2 to 22% of the nominal voltage 2 to 22% of the nominal voltage Specifications are subject to change without notice (06.11.00) 2 x SPDT relays 250 VAC µ 8 A @ 250 VAC 5 A @ 24 VDC 2.5 A @ 250 VAC 2.5 A @ 24 VDC ≥ 30 x 106 operations ≥ 105 operations (at 8 A, 250 V, cos ϕ = 1) ≤ 7200 operations/h Operating frequency Dielectric strength Dielectric voltage 2 kVAC (rms) Rated impulse withstand volt. 4 kV (1.2/50 µs) 1 DPC01, PPC01 Supply Specifications General Specifications (cont.) Power supply Rated operational voltage through terminals: L1, L2, L3, N (DPC01) 5, 6, 7, 11 (PPC01) M23: Indication for Power supply ON Alarm ON M48: Rated operational power M48 M23 Overvoltage cat. III (IEC 60664, IEC 60038) 208 to 240 VAC ± 15% 45 to 65 Hz 380 to 480 VAC ± 15% 45 to 65 Hz 13 VA @ 400 VAC, 50 Hz 13 VA @ 230 VAC, 50 Hz Supplied by L2 and L3 General Specifications Power ON delay Reaction time Incorrect phase sequence or total phase loss Voltage level Asymmetry level Alarm ON delay Alarm OFF delay Accuracy Temperature drift Delay ON alarm Repeatability 1 s ± 0.5 s or 6 s ± 0.5 s < 200 ms (input signal variation from -20% to +20% or from +20% to -20% of set value) Output relay ON Environment Degree of protection Pollution degree Operating temperature Storage temperature Housing dimensions DIN-rail version Plug-in version Weight Screw terminals Tightening torque CE-Marking LED, green LED, red (flashing 2 Hz during delay time) 2 x LED, yellow (EN 60529) IP 20 3 (DPC01), 2 (PPC01) -20 to 60°C, R.H. < 95% @ 475 VAC, 65 Hz -20 to 50°C, R.H. < 95% @ 550 VAC, 65 Hz -30 to 80°C, R.H. < 95% 45 x 80 x 99.5 mm 36 x 80 x 87 mm Approx. 220 g Max. 0.5 Nm acc. to IEC 60947 Yes < 200 ms (delay < 0.1 s) < 200 ms (delay < 0.1 s) (15 min warm-up time) ± 1000 ppm/°C ± 10% on set value ± 50 ms ± 0.5% on full-scale Mode of Operation Connected to the 3 phases (and neutral) DPC01 and PPC01 operate when all 3 phases are present at the same time and the phase sequence is correct. It can be decided whether to monitor upper and lower voltage level of each phase or their asymmetry and tolerance. In any case if phase-netural measurement is selected both phase-phase and phase-neutral voltages are monitored. Asymmetry is defined as follows: max{|∆Vph-ph|} nom. voltage when measuring phasephase voltages and also as follows: max{|∆Vph-n|} nom. voltage 2 when measuring phase-neutral voltages. Tolerance is defined as max{|nom. voltage - ∆Vph-ph|} nom. voltage and also as max{|nom. voltage - ∆Vph-n|} nom. voltage when measuring phase-neutral voltages. Voltage level monitoring: if one or more phase-phase or phase-neutral voltage exceeds the upper set level or drops below the lower set level, the red LED starts flashing 2 Hz and the respective output relay releases after the set time period. Asymmetry and tolerance monitoring: if one of them exceeds the set level the red LED starts flashing 2 Hz and the respective output relay releases after the set time period. If the phase sequence is wrong or one phase is lost, both output relays release immediately. Only 200 ms delay occurs. The failure is indicated by the red LED flashing 5 Hz during the alarm condition. Example 1 (mains - over and under phase-phase voltage - monitoring) The relay monitors over and under voltage, phase loss and correct phase sequence. Example 2 (starting and operating load asymmetry and tolerance phase-neutral - monitoring) DPC01 and PPC01 ensure correct starting and operating conditions. They monitor the voltage level, phase sequence (correct direction of the motor rotation) and asymmetry. Frequent failures are fuse blowing and incorrect voltage level. In case of fuse blowing the motor regenerates a voltage in the interrupted phase. These relays detect the failure and react due to excessive imbalance among the phases. Specifications are subject to change without notice (06.11.00) DPC01, PPC01 Function/Range/Level and Time Delay Setting 34 Selection of function: DIP-switch selector (1 to 6) 3 x 220 ∆ VAC (M23) 3 x 400 ∆ VAC (M48) 1 ON 3 x 208 ∆ VAC (M23) 3 x 380 ∆ VAC (M48) Power ON delay 6 ± 0.5 s Power ON delay 1 ± 0.5 s 3 x 230 ∆ VAC (M23) 3 x 415 ∆ VAC (M48) 2 Phase-neutral voltage Phase-phase voltage Selection of level and time delay: 5 2 x SPDT relays 1 x DPDT relay Centre knobs: Setting of upper and lower level or setting of asymmetry and absolute tolerance of set value on relative scale. 6 Asymmetry + tolerance Overvoltage + undervoltage Lower knobs: Setting of delay on alarm time on absolute scale (0.1 to 30 s). 3 x 240 ∆ VAC (M23) 3 x 480 ∆ VAC (DPC01DM48) Wiring Diagrams Example 1 Example 1 N L3 L2 L1 N L3 L2 L1 µ 5 m<3 L1 L2 L3 m<3 16 18 26 28 6 7 4 3 8 9 U U L2 L3 L2 L3 µ µ µ 15 N 1 11 10 25 Example 2 Example 2 N L3 L2 L1 N L3 L2 L1 µ µ 5 m<3 L1 L2 L3 m<3 16 18 26 28 6 7 4 3 8 9 U U L2 L3 L2 L3 µ µ N 15 11 1 10 25 PPC01 DPC01 Operation Diagrams L1 L1 L2 L1 L2 L3 L1 L2 L3 L2 L3 L3 Relay (1) ON Relay (2) ON Red LED ON 1 or 6 s Specifications are subject to change without notice (06.11.00) 3 DPC01, PPC01 Operation Diagrams (cont.) L1 or L1-L2 Upper Level Hysteresis L2 or L2-L3 Hysteresis Lower Level L3 or L1-L3 Relay 1(Upper) ON (15/16/18) T 1 or 6 s Relay 2 (Lower) ON (25/26/28) 1 or 6 s Red LED ON T T 1 or 6 s L2-L1 or VL2-L1-VL3-L2 Asymmetry (+) Hysteresis L3-L2 or VL3-L2-VL1-L3 Balanced Hysteresis Asymmetry (-) L1-L3 or VL1-L3-VL2-L1 Relay 1 Asymmetry 1 or 6 s (15/16/18) ON Red LED ON 1 or 6 s Relay 2 Tolerance (25/26/28) ON 1 or 6 s T T T T T L1 or L1-L2 Tolerance (+) Hysteresis Nominal Voltage L2 or L2-L3 Hysteresis Tolerance (-) L3 or L1-L3 4 Specifications are subject to change without notice (06.11.00)