FUJI EDS9-21C

FC SERIES PT TYPE SIGNAL CONVERTER
DATA SHEET
PTA
The FC series PT type signal converter converts inputs
from a thermocouple, resistance bulb, DC voltage and current into a signal of isolated 1 to 5V DC or 4 to 20mA DC.
In addition, burnout protection in the event of thermocouple breakage, transmission function are avaiable.
Its structure is plug-in style.
SPECIFICATIONS
INPUT SPECIFICATION
Input signal:
1 point
Input signal
Type
Measuring range
Min. span width
Thermocouple
B(*1)
E
J
K
N(*2)
R
S
T
Pt 100(*3)
JPt 100(*3)
mV
mA
POT
0 to 1700°C
–200 to 800°C
0 to 750°C
–200 to 1200°C
0 to 1300°C
0 to 1600°C
0 to 1600°C
–200 to 350°C
–200 to 650°C
–200 to 500°C
3 to 100mV
0.1 to 10mA
50 to 300Ω
900°C
100°C
100°C
100°C
100°C
400°C
400°C
100°C
50°C
50°C
3mA
0.1mA
20Ω
Resistance bulb
Voltage
Current
Potentiometer
Note: (*1) : With the B thermocouple, accuracy guarantee is in the
range of 600 to 1700°C.
(*2) : N : NICROSIL-NISIL (IEC584)
(*3) : Pt 100 : JIS C 1604, 1606, IEC751
JPt 100 : JIS C 1604, 1606 (OLD JIS Pt100)
Input type Voltage Thermocouple Current
Input
resistance
1MΩ or more
Allowable
wiring
resistance
1kΩ or less
Resistance
Potentiometer
bulb
10 to
250Ω
10Ω or less
* : Zero elevation is ± 25mV or less.
POWER SUPPLY
Power supply:
24V DC (20 to 30V DC)
24V AC, +13%, –10%, (47 to 63Hz)
100V AC (85 to 132V AC /47 to 63Hz)
200V AC (187 to 264V AC /47 to 63Hz)
as specified.
Power consumption:
Approx. 3W (at DC power)
Approx. 6VA (at AC power)
OPERATION CONDITION
OUTPUT SPECIFICATION
Output signal:
Connectable units:
31 units (Max.)
Code format: Data length……8 bits (binary)
Parity bit……even, odd, none
Stop bit……one or two bits
Transmission distance:
1 km (Max.)
2. Loader interface
RS-232C equivalent
2 points
Output type
Voltage
Current
Output signal
1 to 5V DC
4 to 20mA DC
Allowable load 15kΩ or over
resistance
600Ω or less
TRANSMISSION SPECIFICATION
1. Data transmission
Interface:
RS-485
Transmission system:
Start-stop synchronous system
Transmission speed:
2400, 4800, 9600, 19200bps
Ambient temperature:
0 to 50°C
Ambient humidity:
Less than 90%RH (no condensation)
Outline dimension (HxWxD):
96 x 52 x 130mm
Mass:
Appox. 300g
Housing:
Plastic housing (color: black)
Mounting method:
Panel mounting or DIN rail mounting
CHARACTERISTICS
Accuracy:
Less than ± 0.1% of full span
(in case of 10mV span or more)
EDS9-21c
Date
Mar. 25, 1999
PTA
Less than ± 0.2% of full span
(in case of less than 10mV span )
Less than ± 0.1% of full span or ± 0.1°C,
whichever is larger.
(in case of resistance bulb)
Linearizing error: Less than ± 0.05% of full span
Referece junction compensation accuracy:
E, J, K, T ................. ± 1°C
R, S, N ..................... ± 2°C
Response time: 0.3 sec.
Burnout time:
10 sec. or less
Ambient temperature effect:
Less than ± 0.1% of full span/10°C
Power regulation effect:
Less than ± 0.1% of full span
Dielectric strength:
1500V AC, 1 min.
(Input-Output-Transmission-PowerGround)
Insulation resistance:
500V DC, 100MΩ or over
(Input-Output-Transmission-PowerGround)
CODE SYMBOLS
1 2 3 4 5 6 7 8
P T A
W
The input signal and measuring range below can be selected with a front switch. For others, specify separately.
Input signal
Description
R
Input signal
Voltage (mV)
Current (mA)
Thermocouple
Resistance bulb
Potentiometer (3-wire system)
1
2
3
4
5
Output signal
1 to 5V DC/4 to 20mA DC
W
Burnout
Without
Down-scale
Up-scale
Y
L
H
Power supply
24V DC/24V AC (50/60Hz)
100V AC (50/60Hz)
200V AC (50/60Hz)
1
2
3
Application
For general
For zener barrier connection
Y
A
Transmission function
With RS-485
R
Y
Loader interface
Without
Measuring range
B
0 to 1700, 600 to 1700
R
0 to 1000, 0 to 1200, 0 to 1400, 0 to 1600, 400 to
1400, 600 to 1600, 800 to 1600
S
0 to 1000, 0 to 1200, 0 to 1400, 0 to 1600, 400 to
1400, 600 to 1600, 800 to 1600
K
–200 to 100, 0 to 300, 0 to 400, 0 to 500, 0 to 600,
0 to 800, 0 to 1000, 0 to 1200, 300 to 600, 400 to
800, 500 to 1000, 600 to 1200
E
–200 to 100, 0 to 200, 0 to 300, 0 to 400, 0 to 500,
0 to 600, 0 to 800, 200 to 400, 300 to 600
J
0 to 200, 0 to 300, 0 to 400, 0 to 500, 0 to 600,
200 tp 400, 300 to 600
T
–200 to 100, 0 to 300
N
0 to 300, 0 to 400, 0 to 500, 0 to 600, 0 to 800, 0
to 1000, 0 to 1200, 300 to 600, 400 to 800, 500 to
1000, 600 to 1200
Pt 100
0 to 50, 0 to 100, 0 to 150, 0 to 200, 0 to 300, 0 to
400, 0 to 500, 100 to 300, 200 to 400, 300 to 500,
–20 to 30, –50 to 50, –50 to 100, –200 to 50, –200
to 100
Thermocouple
[°C]
Resistance
bulb
[°C]
9 10 11
1 -
STANDARD INPUT RANGE
0 to 50, 0 to 100, 0 to 150, 0 to 200, 0 to 300, 0 to
400, 0 to 500, 100 to 300, 200 to 400, 300 to 500,
JPt 100
–20 to 30, –50 to 50, –50 to 100, –200 to 50, –200
to 100
Potentionmeter
[Ω]
10–100–10, 0–100–0, 10–135–10, 0–135–0
Voltage
[mV]
0 to 5, 0 to 10, 0 to 20, 0 to 30, 0 to 50, 0 to 100
Current
[mA]
4 to 20, 0 to 20, 0 to 10
FUNCTIONAL DIAGRAM
Reference junction
compensator
I+
11
I–
12
I0
21
I–
22
Transmission
circuit
5
+
6
–
RS-485
31
+
32
–
13
41
+
14
42
–
43
+
44
–
AC/DC
conversion
Calculation
circuit
DC/AC
conversion
Rcj
Input
Thermocouple
Resistance bulb
mV, mA
Potentinmeter
Switch
panel
23
Power
supply
circuit
24
34
OUTLINE DIAGRAM (Unit: mm)
Terminal screw M2.5
(for transmission)
35
74
94
Main unit
Terminal
2
48
52
100
Stopper
130
Panel mounting
DIN rail mounting
2-M4
DIN rail
40
52
Stopper
Output
(DC 1~ 5v)
Power supply
Loader
interface
Terminal screw M4
Output
(DC 4~ 20mA)
PTA
EXTERNAL CONNECTION DIAGRAM
Thermocouple input
Resistance bulb input
Rcj
+
11 12
13 14
11 12
13 14
21 22
23 24
21 22
23 24
+
5
+
+
RS-485
-
6
5
+
RS-485
-
31 32
+
-
-
6
-
31 32
+
-
33 34
OUTPUT(mA)
33 34
OUTPUT(mA)
41 42
+
-
43 44
41 42
+
-
43 44
OUTPUT(V)
POWER
OUTPUT(V)
POWER
Potentiometer Input
Voltage•Current Input
INPUT
11 12
21 22
+
5
13 14
+
11 12
13 14
23 24
21 22
23 24
+
+
-
-
RS-485
-
6
5
+
RS-485
31 32
+
-
33 34
OUTPUT(mA)
6
-
31 32
+
-
33 34
OUTPUT(mA)
41 42
+
-
43 44
41 42
+
-
43 44
OUTPUT(V)
POWER
OUTPUT(V)
POWER
RANGE OF DELIVERY
Main unit and socket
ORDERING INFORMATION
1. Input signal specification
2. Measuring range
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
Head Office
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,
Shinagawa-ku, Tokyo 141-0032, Japan
http://www.fesys.co.jp/eng
Instrumentation Div.
International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan
Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187
http://www.fic-net.jp/eng
Information in this catalog is subject to change without notice.
Printed in Japan