ETC G6CK-2117P-US-DC6

Power PCB Relay
G6C
■
Subminiature 20.07 L x 14.99 W x 9.91 H mm
(0.79 L x 0.59 W x 0.39 H in)
Low power consumption (200 mW)
Semi-sealed and sealed types available
Unique moving magnet armature (Moving
Loop System) reduces relay size, magnetic
interference, and contact bounce time
Single and double-winding latching types
available
High sensitivity in a compact package
■
Long life assured by high contact pressure
■
■
■
■
■
DVE
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G6C-1117P-US-DC6).
Type
Non-latching
Single-winding latching contact
Dual-winding latching contact
Contact form
SPST-NO
SPST-NO + SPST-NC
SPST-NO
SPST-NO + SPST-NC
SPST-NO
SPST-NO + SPST-NC
SPST-NO
SPST-NO + SPST-NC
SPST-NO
SPST-NO + SPST-NC
SPST-NO
SPST-NO + SPST-NC
Construction
Sealed
Semi-sealed
Sealed
Semi-sealed
Sealed
Semi-sealed
Part number
G6C-1114P-US
G6C-2114P-US
G6C-1117P-US
G6C-2117P-US
G6CU-1114P-US
G6CU-2114P-US
G6CU-1117P-US
G6CU-2117P-US
G6CK-1114P-US
G6CK-2114P-US
G6CK-1117P-US
G6CK-2117P-US
■ ACCESSORIES
Back connecting sockets
Relay
G6C-1114P-US
G6C-1117P-US
G6C-2114P-US
G6C-2117P-US
G6CU-1114P-US
G6CU-1117P-US
G6CU-2114P-US
G6CU-2117P-US
G6CK-1114P-US
G6CK-1117P-US
G6CK-2114P-US
G6CK-2117P-US
Part number
P6C-06P
P6C-08P
G6C
G6C
Specifications
■ CONTACT DATA
Non-latching
Load
Rated load
Contact material
Carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
SPST-NO
Resistive load
(p.f. = 1)
10 A at 250 VAC
10 A at 30 VDC
AgCdO
10 A
380 VAC, 125 VDC
10 A
2,500 VA, 300 W
10 mA, 5 VDC
Inductive load
(p.f. = 0.4) (L/R = 7 ms)
5 A at 250 VAC
5 A at 30 VDC
SPST-NO + SPST-NC
Resistive load
(p.f. = 1)
8 A at 250 VAC
8 A at 30 VDC
Inductive load
(p.f. = 0.4) (L/R = 7 ms)
3.5 A at 250 VAC
3.5 A at 30 VDC
8A
1,250 VA, 220 W
8A
2,000 VA, 240 W
875 VA, 170 W
Inductive load
(p.f. = 0.4) (L/R = 7 ms)
5 A at 250 VAC
5 A at 30 VDC
SPST-NO + SPST-NC
Resistive load
(p.f. = 1)
8 A at 250 VAC
8 A at 30 VDC
Inductive load
(p.f. = 0.4) (L/R = 7 ms)
3.5 A at 250 VAC
3.5 A at 30 VDC
Latching
Load
Rated load
Contact material
Carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
SPST-NO
Resistive load
(p.f. = 1)
10 A at 250 VAC
10 A at 30 VDC
AgCdO
10 A
380 VAC, 125 VDC
10 A
2,500 VA, 300 W
10 mA, 5 VDC
8A
1,250 VA, 220 W
8A
2,000 VA, 240 W
3.5 A
875 VA, 105 W
■ COIL DATA
Non-latching
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
3
5
6
12
24
66.70
40
33.30
16.70
8.30
Coil inductance
(ref. value) (H)
Armature
OFF
Armature
ON
45
125
180
720
2,880
0.078
0.22
0.36
1.32
4.96
0.067
0.18
0.29
1.13
4.19
Pick-up
voltage
Dropout
voltage
% of rated voltage
70% max. 10% min.
Maximum
voltage
Power
consumption
(mW)
160% max.
at 23°C (73°F)
Approx. 200
130% max.
at 70°C
(158° F)
Single-winding latching type
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
Coil inductance
(ref. value) (H)
3
5
6
12
24
66.70
40
33.30
16.70
8.30
45
125
180
720
2,880
0.09
0.25
0.36
1.75
5.83
Set pick-up
voltage
Reset pick-up
voltage
% of rated voltage
70% max.
70% min.
Maximum
voltage
Power
consumption
(mW)
160% max.
at 23°C (73°F)
Approx. 200
130% max.
at 70°C
(158°F)
Note: The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%.
2
G6C
G6C
■ COIL DATA
Dual-winding latching type
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
3
5
6
12
24
93.50
56
46.70
23.30
11.70
32.10
89.30
129
514
2,056
Coil inductance
(ref. value) (H)
Set
Coil
Reset
Coil
0.03
0.07
0.10
0.37
1.56
0.03
0.08
0.12
0.47
1.46
Set
pick-up
voltage
Reset
pick-up
voltage
% of rated voltage
70% max.
70% max.
Maximum
voltage
Power
consumption
(mW)
160% max.
at 23°C (73°F)
Approx. 280
110% max.
at 70°C
(158°F)
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C (73°F).
3. The minimum pulse width of the set and reset voltage is 20 ms.
■ CHARACTERISTICS
Contact resistance
Operate (set) time
Release (reset) time
Bounce time
Operating
frequency
Operate
Release
Mechanical
Electrical
Insulation resistance
Dielectric strength
Surge withstand voltage
Vibration
Mechanical durability
Malfunction durability
Shock
Mechanical durability
Malfunction durability
Ambient temperature
Humidity
Service life
Mechanical
Electrical
Weight
Non-latching
Latching
30 mΩ max.
10 ms max. (mean value: approx. 5 ms)
10 ms max. (mean value: approx. 2 ms)
Approx. 3 ms
Approx. 3 ms
18,000 operations/hour
1,800 operations/hour (under rated load)
1,000 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 minute between coil and contacts, non-latching types
2,000 VAC, 50/60 Hz for 1 minute between contacts of different poles, non-latching
1,000 VAC, 50/60 Hz for 1 minute between contacts of same pole, non-latching
250 VAC, 50/60 Hz for 1 minute between set and reset coils, latching types
4,500 V x 40 µs (between coil and contacts, non-latching)
10 to 55 Hz; 1.50 mm (0.06 in) double amplitude
10 to 55 Hz; 1.50 mm (0.06 in) double amplitude
Approx. 100 G
Approx. 10 G
-25 to 70°C (-13° to 158°F)
45 to 85% RH
50 million operations min. (at operating frequency of 18,000 operations/hour)
See “Characteristic Data”
Approx. 5.6 g (0.20 oz)
Note: Data shown are of initial value.
3
G6C
G6C
■ CHARACTERISTIC DATA
Non-latching types
SPST-NO + SPST-NC
Rated operating voltage (V)
Ambient temperature vs.
maximum voltage
(reference only)
Rated operating voltage (V)
Maximum voltage (%)
Service life (x103 operations)
SPST-NO
Rated operating current (A)
Electrical service life
Rated operating current (A)
Maximum switching capacity
Rated operating current (A)
Ambient temperature (°C)
Latching types
SPST-NO + SPST-NC
Rated operating voltage (V)
Ambient temperature vs.
maximum voltage
(reference only)
Rated operating voltage (V)
Maximum voltage (%)
Service life (x103 operations)
SPST-NO
Rated operating current (A)
Electrical service life
Rated operating current (A)
Maximum switching capacity
Rated operating current (A)
Ambient temperature (°C)
Dimensions
Unit: mm (inch)
■ NON-LATCHING RELAYS
G6C-■
■ 117P-US
Terminal arrangement/
Internal connections
(Bottom view)
G6C-1117P-US, G6C-1114P-US
12345
12345 and
Note: 12345
4
indicate mounting orientation marks.
Mounting holes
[Bottom view, Tolerance: ±2.54 (0.10)]
G6C
G6C
G6C-■
■ 114P-US
Terminal arrangement/
Internal connections
(Bottom view)
Mounting holes
(Bottom view, Tolerance: ±2.54 [0.10])
G6C-2117P-US, G6C-2114P-US
■ LATCHING RELAYS
Single winding types, 1-pole
G6CU-1117P-US, G6CU-1114P-US
Terminal arrangement/
Internal connections
(Bottom view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Bottom view)
Mounting holes
(Bottom view)
Single winding types, 2-pole
G6CU-2117P-US, G6CU-2114P-US
123456
123456
Note: 123456and
indicate mounting orientation marks.
5
G6C
G6C
Unit: mm (inch)
■ LATCHING RELAYS (continued)
Double winding types, 1-pole
G6CK-1117P-US, G6CK-1114P-US
Terminal arrangement/
Internal connections
(Bottom view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Bottom view)
Mounting holes
(Bottom view)
Mounting height of relay
width connecting socket
Mounting holes
(Bottom view)
Double winding types, 2-pole
G6CK-2117P-US, G6CK-2114P-US
■ ACCESSORIES
Connecting sockets – P6C-06P, P6C-08P
P6C-06P
P6C-08P
12345
12345
Note: 12345 and
6
indicate mounting orientation marks.
G6C
G6C
■ APPROVALS
UL (File No. E41643)/ CSA (File No. LR31928)
Type
G6C-1114P-US
G6C-1117P-US
Contact Form
SPST-NO
Coil Rating
3 to 60 VDC
G6C-2114P-US
G6C-2117P-US
SPST-NO +
SPST-NC
3 to 60 VDC
G6C(U/K)-1114P-US
G6C(U/K)-1117P-US
SPST-NO
3 to 60 VDC
G6C(U/K)-2114P-US
G6C(U/K)-2117P-US
SPST-NO +
SPST-NC
3 to 60 VDC
Type
G6C-1117P-VD
G6C-1114P-VD
Contact Form
SPST-NO
Coil Rating
DC3, 12, 24V
G6C-2117P-VD
G6C-2114P-VD
SPST-NO +
SPST-NC
DC3, 12, 24V
Contact Ratings
10 A, 250 VAC (General purpose)
10 A, 30 VDC (Resistive)
TV-5
1/4 HP, 125 VAC
1/4 HP, 250 VAC (Motor load)
1/3 HP, 250 VAC (Motor load)
600 WT, 120 VAC (Tungsten)
530 VA, 265 VAC, 2 A max. pilot duty
43.2 VA, 30 VDC, pilot duty
22 LRA, 3.6 FLA, 30 VDC
8 A, 250 VAC (General purpose)
8 A, 30 VDC (Resistive)
TV-5
1/4 HP, 125 VAC
1/4 HP, 250 VAC (Motor load)
600 WT, 120 VAC (Tungsten)
530 VA, 265 VAC, 2 A max. pilot duty
43.2 VA, 30 VDC, pilot duty
22 LRA, 3.6 FLA, 30 VDC
10 A, 250 VAC (General purpose)
10 A, 30 VDC (Resistive)
1/6 HP, 125 VAC (Motor load)
TV-5
1/4 HP, 125 VAC
1/4 HP, 250 VAC (Motor load)
1/3 HP, 250 VAC (Motor load)
600 WT, 120 VAC (Tungsten)
8 A, 250 VAC (General purpose)
8 A, 30 VDC (Resistive)
1/6 HP, 125 VAC (Motor load)
TV-5
1/4 HP, 125 VAC
1/4 HP, 250 VAC (Motor load)
1/3 HP, 250 VAC (Motor load)
600 WT, 120 VAC (Tungsten)
VDE (File No. 2314)
Contact Ratings
250 VAC
10 A (Resistive)
5 A (Inductive)
250 VAC
7 A (Resistive)
3.5 A (Inductive)
Note: 1. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance
characteristics individually defined in this catalog.
2. In the interest of product improvement, specifications are subject to change.
7
G6C
OMRON ELECTRONICS, INC.
OMRON CANADA, INC.
One East Commerce Drive
Schaumburg, IL 60173
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. GC RLY7
8
G6C
01/00
Specifications subject to change without notice.
Printed in the U.S.A.