ETC GTLP18T612MEAX

Revised July 2002
GTLP18T612
18-Bit LVTTL/GTLP Universal Bus Transceiver
General Description
Features
The GTLP18T612 is an 18-bit universal bus transceiver
which provides LVTTL to GTLP signal level translation. It
allows for transparent, latched and clocked modes of data
transfer. The device provides a high speed interface for
cards operating at LVTTL logic levels and a backplane
operating at GTLP logic levels. High speed backplane
operation is a direct result of GTLP’s reduced output swing
(< 1V), reduced input threshold levels and output edge rate
control. The edge rate control minimizes bus settling time.
GTLP is a Fairchild Semiconductor derivative of the Gunning Transistor logic (GTL) JEDEC standard JESD8-3.
■ Bidirectional interface between GTLP and LVTTL logic
levels
Fairchild’s GTLP has internal edge-rate control and is Process, Voltage, and Temperature (PVT) compensated. Its
function is similar to BTL or GTL but with different output
levels and receiver thresholds. GTLP output LOW level is
less than 0.5V, the output HIGH is 1.5V and the receiver
threshold is 1.0V.
■ Designed with edge rate control circuitry to reduce output noise on the GTLP port
■ VREF pin provides external supply reference voltage for
receiver threshold adjustibility
■ Special PVT compensation circuitry to provide consistent performance over variations of process, supply voltage and temperature
■ TTL compatible driver and control inputs
■ Designed using Fairchild advanced BiCMOS technology
■ Bushold data inputs on A port to eliminate the need for
external pull-up resistors for unused inputs
■ Power up/down and power off high impedance for live
insertion
■ Open drain on GTLP to support wired-or connection
■ Flow through pinout optimizes PCB layout
■ D-type flip-flop, latch and transparent data paths
■ A Port source/sink −24mA/+24mA
■ B Port sink +50mA
■ Also packaged in plastic Fine-Pitch Ball Grid Array
(FBGA)
Ordering Code:
Order Number
GTLP18T612G
(Note 1)(Note 2)
Package Number
BGA54A
GTLP18T612MEA
(Note 2)
MS56A
GTLP18T612MTD
(Note 2)
MTD56
Package Description
54-Ball Fine-Pitch Ball Grid Array (FBGA), JEDEC MO-205, 5.5mm Wide
56-Lead Shrink Small Outline Package (SSOP), JEDEC MO-118, 0.300" Wide
56-Lead Thin Shrink Small Outline Package (TSSOP), JEDEC MO-153, 6.1mm Wide
Note 1: Ordering code “G” indicates Trays.
Note 2: Device also available in Tape and Reel. Specify by appending suffix letter “X” to the ordering code.
© 2002 Fairchild Semiconductor Corporation
DS500169
www.fairchildsemi.com
GTLP18T612 18-Bit LVTTL/GTLP Universal Bus Transceiver
May 1999
GTLP18T612
Connection Diagrams
Pin Descriptions
Pin Assignments for SSOP and TSSOP
Pin Names
Description
OEAB
A-to-B Output Enable
(Active LOW) (LVTTL Level)
OEBA
B-to-A Output Enable
(Active LOW) (LVTTL Level)
CEAB
A-to-B Clock/LE Enable
(Active LOW) (LVTTL Level)
CEBA
B-to-A Clock/LE Enable
(Active LOW) (LVTTL Level)
LEAB
A-to-B Latch Enable
(Transparent HIGH) (LVTTL Level)
LEBA
B-to-A Latch Enable
(Transparent HIGH) (LVTTL Level)
VREF
GTLP Input Threshold
Reference Voltage
CLKAB
A-to-B Clock (LVTTL Level)
CLKBA
B-to-A Clock (LVTTL Level)
A1–A18
A-to-B Data Inputs or
B-to-A 3-STATE Outputs
B1–B18
B-to-A Data Inputs or
A-to-B Open Drain Outputs
FBGA Pin Assignments
Pin Assignments for FBGA
(Top Thru View)
www.fairchildsemi.com
2
1
2
A
A2
A1
OEAB CLKAB
3
4
5
6
B2
B1
B
A4
A3
LEAB
C
A6
A5
VCC
CEAB
B4
B3
VCC
B6
D
A8
A7
B5
GND
GND
B8
E
A10
B7
A9
GND
GND
B10
F
B9
A12
A11
GND
GND
B12
B11
G
A14
A13
VCC
VREF
B14
B13
H
A16
A15
OEBA CEBA
B16
B15
J
A18
A17
LEBA CLKBA
B18
B17
Truth Table
The GTLP18T612 is an 18 bit registered transceiver containing D-type flip-flop, latch and transparent modes of
operation for the data path. Data flow in each direction is
controlled by the clock enables (CEAB and CEBA), latch
enables (LEAB and LEBA), clock (CLKAB and CLKBA)
and output enables (OEAB and OEBA). The clock enables
(CEAB and CEBA) and the output enables (OEAB and
OEBA) control the 18 bits of data for the A-to-B and B-to-A
directions respectively.
(Note 3)
For A-to-B data flow, when CEAB is LOW, the device operates on the LOW-to-HIGH transition of CLKAB for the flipflop and on the HIGH-to-LOW transition of LEAB for the
latch path. That is, if CEAB is LOW and LEAB is LOW the
A data is latched regardless as to the state of CLKAB
(HIGH or LOW) and if LEAB is HIGH the device is in transparent mode. When OEAB is LOW the outputs are active.
When OEAB is HIGH the outputs are HIGH impedance.
The data flow of B-to-A is similar except that CEBA, OEBA,
LEBA, and CLKBA are used.
Inputs
Output
CEAB OEAB LEAB CLKAB A
B
Z
Mode
X
H
X
X
X
L
L
L
H
X B0 (Note 4)
Storage
L
L
L
L
X B0 (Note 5)
of A Data
X
L
H
X
L
L
X
L
H
X
H
H
L
L
L
↑
L
L
L
L
L
↑
H
H
Latched
Transparent
Clocked
Storage
of A Data
H
L
L
X
X B0 (Note 5) Clock Inhibit
Note 3: A-to-B data flow is shown. B-to-A data flow is similar but uses
OEBA, LEBA, CLKBA, and CEBA.
Note 4: Output level before the indicated steady state input conditions were
established, provided that CLKAB was HIGH before LEAB went LOW.
Note 5: Output level before the indicated steady-state input conditions
were established.
Logic Diagram
3
www.fairchildsemi.com
GTLP18T612
Functional Description
GTLP18T612
Absolute Maximum Ratings(Note 6)
Supply Voltage (VCC )
−0.5V to +4.6V
DC Input Voltage (VI)
−0.5V to +4.6V
Recommended Operating
Conditions (Note 8)
Supply Voltage VCC /VCCQ
DC Output Voltage (VO)
3.15V to 3.45V
Bus Termination Voltage (VTT)
−0.5V to +4.6V
Outputs 3-STATE
−0.5V to VCC + 0.5V
Outputs Active (Note 7)
DC Output Sink Current into
GTLP
1.47V to 1.53V
VREF
0.98V to 1.02V
Input Voltage (VI)
A Port IOL
48 mA
DC Output Source Current from
A Port IOH
on A Port and Control Pins
0.0V to 3.45V
on B Port
0.0V to 3.45V
−48 mA
HIGH Level Output Current (IOH)
100 mA
LOW Level Output Current (IOL)
DC Output Sink Current into
−24 mA
A Port
B Port in the LOW State, IOL
DC Input Diode Current (IIK)
+24 mA
A Port
VI < 0V
−50 mA
+50 mA
B Port
DC Output Diode Current (IOK)
−40°C to +85°C
Operating Temperature (TA)
VO < 0V
−50 mA
VO > VCC
+50 mA
Note 6: Absolute Maximum continuous ratings are those values beyond
which damage to the device may occur. Exposure to these conditions or
conditions beyond those indicated may adversely affect device reliability.
Functional operation under absolute maximum rated conditions in not
implied.
>2000V
ESD Performance
−65°C to +150 °C
Storage Temperature (TSTG)
Note 7: IO Absolute Maximum Rating must be observed.
Note 8: Unused inputs must be held HIGH or LOW.
DC Electrical Characteristics
Over Recommended Operating Free-Air Temperature Range, VREF = 1.0V (unless otherwise noted).
Symbol
VIH
VIL
Test Conditions
Min
Typ
B Port
VREF +0.05
Others
2.0
B Port
0.0
VTT
VREF − 0.05
Others
VREF
0.8
GTLP (Note 10)
1.0
GTL
0.8
VCC = 3.15V
VIK
VOH
A Port
II = −18 mA
VCC, VCCQ = Min to Max (Note 11) IOH = −100 µA
VCC = 3.15V
VOL
A Port
B Port
II
2.4
IOH = -24mA
2.0
0.2
VCC = 3.15V
IOL = 40 mA
0.40
IOL = 50 mA
0.55
Control Pins
VCC = Min to Max (Note 11)
VI = 3.45V or 0V
±5
VCC = 3.45V
VI = 0V
−10
VI = 3.45
10
A Port
A Port
VCC = 3.45V
VCC = 3.45V
B Port
A or B Ports
(VCC/VCCQ)
www.fairchildsemi.com
5
VI = 0
−5
VI = 0.8V
B Port
A Port
VI = VCC
VI or VO = 0 to 3.45V
VCC = 3.15V
30
75
VI = 2.0V
−75
VO = 3.45
10
VO = 1.5V
5
VO = 0V
−10
VO = 0.55V
−5
VCC = 3.45V
Outputs HIGH
30
40
IO = 0
Outputs LOW
30
40
VI = VCC or GND
Outputs Disabled
30
45
4
V
V
V
0.5
A Port and Control Pins VCC = 0
ICC
IOH = −8 mA
IOL = 24mA
IOFF
IOZL
−1.2
VCC, VCCQ = Min to Max (Note 11) IOL = 100 µA
II(hold)
V
VCC –0.2
VCC = 3.15V
VCC = 3.45V
Units
V
A Port
B Port
IOZH
Max
(Note 9)
V
V
µA
µA
µA
µA
µA
µA
µA
mA
Symbol
(Continued)
Test Conditions
Min
Typ
Max
Units
2
mA
(Note 9)
∆ICC
A Port and
VCC = 3.45V,
(Note 12)
Control Pins
A or Control Inputs at VCC or GND
Ci
Control Pins
VI = VCC or 0
6
A Port
VI = VCC or 0
7.5
B Port
VI = VCC or 0
9.0
One Input at 2.7V
0
pF
Note 9: All typical values are at VCC = 3.3V, VCCQ = 3.3V, and TA = 25°C.
Note 10: GTLP VREF and VTT are specified to 2% tolerance since signal integrity and noise margin can be significantly degraded if these supplies are noisy.
In addition, VTT and Rterm can be adjusted beyond the recommended operating conditions to accommodate backplane impedances other than 50Ω, but
must remain within the boundaries of the DC Absolute Maximum ratings. Similarly VREF can be adjusted to optimize noise margin.
Note 11: For conditions shown as Min or Max, use the appropriate value specified under recommended operating conditions.
Note 12: This is the increase in supply current for each input that is at the specified TTL voltage level rather than VCC or GND.
AC Operating Requirements
Over recommended ranges of supply voltage and operating free-air temperature, VREF = 1.0V (unless otherwise noted).
Symbol
fMAX
Maximum Clock Frequency
tWIDTH
Pulse Duration
tSU
tHOLD
Setup Time
Hold Time
Test Conditions
Min
175
LEAB or LEBA HIGH
3.0
CLKAB or CLKBA HIGH or LOW
3.0
A before CLKAB↑
1.1
B before CLKBA↑
3.0
A before LEAB
1.1
B before LEBA
2.7
CEAB before CLKAB↑
1.2
CEBA before CLKBA↑
1.4
A after CLKAB↑
0.0
B after CLKBA↑
0.0
A after LEAB
0.8
B after LEBA
0.0
CEAB after CLKAB↑
1.0
CEBA after CLKBA↑
1.9
5
Max
Unit
MHz
ns
ns
ns
www.fairchildsemi.com
GTLP18T612
DC Electrical Characteristics
GTLP18T612
AC Electrical Characteristics
Over recommended range of supply voltage and operating free-air temperature, VREF = 1.0V (unless otherwise noted).
CL = 30 pF for B Port and CL = 50 pF for A Port.
Symbol
tPLH
From
To
(Input)
(Output)
Min
A
B
tPHL
tPLH
LEAB
B
tPHL
CLKAB
tPLH
B
tPHL
tPLH
OEAB
B
tPHL
tRISE
Transition Time, B Outputs (20% to 80%)
tFALL
Transition Time, B Outputs (20% to 80%)
tPLH
4.1
6.3
1.0
2.7
4.4
2.2
4.2
6.3
1.0
2.4
4.2
2.2
4.4
6.5
1.0
2.5
4.4
2.0
3.8
5.6
1.0
2.6
4.3
ns
ns
ns
ns
ns
1.8
1.8
3.8
5.8
LEBA
A
0.3
2.2
4.6
0.4
2.4
4.6
CLKBA
A
0.5
2.4
4.6
0.6
2.6
4.6
0.3
2.7
5.2
0.3
2.5
5.2
OEBA
Unit
2.1
A
tPHL
tPZH, tPZL
2.1
B
tPHL
tPLH
Max
3.1
tPHL
tPLH
Typ
(Note 13)
A
tPHZ, tPLZ
3.8
5.8
ns
ns
ns
ns
Note 13: All typical values are at VCC = 3.3V, and TA = 25°C.
Extended Electrical Characteristics
Over recommended ranges of supply voltage and operating free-air temperature VREF = 1.0V (unless otherwise noted).
CL = 30 pF for B Port and CL = 50 pF for A Port.
Symbol
tOSLH (Note 14)
From
To
(Input)
(Output)
Min
(Note 13)
A
B
tOSHL (Note 14)
tPV(HL) (Note 15)(Note 16)
tOSLH (Note 14)
tOSLH (Note 14)
tPV (Note 15)
Unit
0.8
1.0
ns
0.3
0.5
ns
B
CLKAB
B
CLKAB
B
B
A
0.7
0.6
1.0
ns
B
A
0.7
1.1
ns
1.5
ns
1.0
ns
tOSHL (Note 14)
tOST (Note 14)
Max
A
tOSHL (Note 14)
tPV(HL) (Note 15)(Note 16)
Typ
0.8
ns
0.9
1.0
ns
0.3
0.5
ns
0.8
ns
1.0
ns
B
A
CLKAB
A
0.5
0.6
1.0
ns
tOST (Note 14)
CLKAB
A
1.1
1.2
ns
tPV (Note 15)
CLKAB
A
1.5
ns
tOSLH (Note 14)
tOSHL (Note 14)
Note 14: tOSHL/tOSLH and tOST - Output to output skew is defined as the absolute value of the difference between the actual propagation delay for all outputs
within the same packaged device. The specifications are given for specific worst case VCC and temperature and apply to any outputs switching in the same
direction either HIGH-to-LOW (tOSHL) or LOW-to-HIGH (tOSLH) or in opposite directions both HL and LH (tOST). This parameter is guaranteed by design and
statistical process distribution. Actual skew values between the GTLP outputs could vary on the backplane due to the loading and impedance seen by the
device.
Note 15: tPV - Part to part skew is defined as the absolute value of the difference between the actual propagation delay for all outputs from device to device.
The parameter is specified for a specific worst case VCC and temperature. This parameter is guaranteed by design and statistical process distribution. Actual
skew values between the GTLP outputs could vary on the backplane due to the loading and impedance seen by the device.
Note 16: Due to the open drain structure on GTLP outputs tOST and t PV(LH) in the A-to-B direction are not specified. Skew on these paths is dependent on the
VTT and RT values on the backplane.
www.fairchildsemi.com
6
Test Circuit for A Outputs
Test
Test Circuit for B Outputs
S
tPLH/tPHL Open
tPLZ/tPZL
6V
Note B: For B Port, CL = 30 pF is used for worst case.
tPHZ/tPZH GND
Note A: CL includes probes and Jig capacitance.
Voltage Waveform - Propagation Delay Times
Voltage Waveform - Setup and Hold Times
Voltage Waveform - Pulse Width
Voltage Waveform - Enable and Disable times
Output Waveform 1 is for an output with internal conditions such that the
output is LOW except when disabled by the control output.
Output Waveform 2 is for an output with internal conditions such that the
output is HIGH except when disabled by the control output.
Input and Measure Conditions
A or LVTTL
Pins
B or GTLP
Pins
VinHIGH
3.0
1.5
VinLOW
0.0
0.0
VM
1.5
1.0
VX
VOL + 0.3V
N/A
VY
VOH − 0.3V
N/A
All input pulses have the following characteristics: Frequency = 10MHz, tRISE = tFALL = 2 ns (10% to 90%), Z O = 50Ω.
The outputs are measured one at a time with one transition per measurement.
7
www.fairchildsemi.com
GTLP18T612
Test Circuits and Timing Waveforms
GTLP18T612
Physical Dimensions inches (millimeters) unless otherwise noted
54-Ball Fine-Pitch Ball Grid Array (FBGA), JEDEC MO-205, 5.5mm Wide
Package Number BGA54A
www.fairchildsemi.com
8
GTLP18T612
Physical Dimensions inches (millimeters) unless otherwise noted (Continued)
56-Lead Shrink Small Outline Package (SSOP), JEDEC MO-118, 0.300" Wide
Package Number MS56A
9
www.fairchildsemi.com
GTLP18T612 18-Bit LVTTL/GTLP Universal Bus Transceiver
Physical Dimensions inches (millimeters) unless otherwise noted (Continued)
56-Lead Thin Shrink Small Outline Package (TSSOP), JEDEC MO-153, 6.1mm Wide
Package Number MTD56
Fairchild does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and
Fairchild reserves the right at any time without notice to change said circuitry and specifications.
LIFE SUPPORT POLICY
FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD
SEMICONDUCTOR CORPORATION. As used herein:
2. A critical component in any component of a life support
device or system whose failure to perform can be reasonably expected to cause the failure of the life support
device or system, or to affect its safety or effectiveness.
1. Life support devices or systems are devices or systems
which, (a) are intended for surgical implant into the
body, or (b) support or sustain life, and (c) whose failure
to perform when properly used in accordance with
instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the
user.
www.fairchildsemi.com
www.fairchildsemi.com
10