POWERDYNAMICS HGN-369-1M

HGN-369
IEC 60320 INLET SOCKET WITH VOLTAGE SELECT, FLANGE MOUNT
MECHANICAL DIMENSIONS (Unit: mm)
63.0
Use only with a 250V Fuse
100
240
120
27.0
220
2x
52.0+- 0.1
3.3x90 CSK
0.80 TYP.
20.5
FEATURES
7x 2.80
The HGN-369 power entry modules are used in applications
having the ON/OFF switch on front side but main input at
the rear side. This series features an IEC Connector, voltage
selector for four different voltages (100V, 120V, 220V, 240V),
fuse holder for European 5 x 20mm or N. American 1/4” x 1
1/4” (3AG) fuse. The filter is enclosed in a metal housing to
ensure maximum protection from common-mode and
differential-mode interferences.
46.0
These filters are also available for Medical equipment
with low leakage current to comply with UL 544 & UL2601.
64.0
51.0
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
TECHNICAL DATA
• Rated Voltage: 125/250VAC
• Rated Current: 1A, 2A, 3A, 4A, 6A,
• Power Line Frequency: 50/60Hz
• Max. Leakage Current each
Line to Ground:
@ 250VAC 50Hz: 0.5mA, max
@ 250VAC 50Hz: 2µA*, max
• Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
• Temperature Range: -25C to +85C
3.5
52.0+- 0.1
46.5+-0.5
21.0+0.5
2x M3
* Medical application
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com
77
HGN-369 Series Example & Ordering Code
HGN-369 - 1
CURRENT RATING (A):
=
=
=
=
=
SCHEMATIC:
M
1
2
3
4
6
STANDARD TYPE
=
WITHOUT C(Y); C(X) ONLY
=M
BLANK
Attenuation Tables & Schematics
Non-Medical Applications
Insertion loss in dB (50 Ohm circuit)
E
P
2200pF
N'
E'
2200pF
L(mH)
LOAD
55
60
60
64
60
N
0.033 F
L(mH)
30
LINE
Current
Comm. Mode(L-G) MHz
Diff. mode(L-L) MHz
L
Rating Value .01 .05 .15 .5 1 5 10 30 .01.05 .15 .5 1 5 10
1A
10.3mA 19 34 42 53 57 50 55 55 15 5 5 33 47 71 70
2A
4.6mA 6 18 26 37 44 54 51 60 23 8 10 20 33 68 70
3A
2.5mA 12 18 25 37 45 53 65 60 16 5 10 24 35 64 65
4A
1.2mA 6 16 23 34 40 54 56 65 11 4 4 20 33 63 66
6A
0.8mA 6 15 21 30 35 50 55 60 16 6 6 15 28 60 65
P'
Medical Applications
1A
2A
3A
4A
6A
10.3mA
4.6mA
2.5mA
1.2mA
0.8mA
Comm. Mode(L-G) MHz
Diff. mode(L-L) MHz
.01 .05 .15 .5 1 5 10 30 .01.05 .15 .5 1 5 10 30
22
17
17
10
8
32
30
28
16
13
41
38
34
22
19
51
41
38
30
25
47
42
38
32
29
36
37
30
32
29
31
30
24
30
29
22
22
18
22
25
13
17
17
11
10
8
7
5
5
5
12
9
10
13
10
38
25
25
25
25
52
39
38
36
37
72
67
67
65
65
69
70
71
70
70
41
58
58
60
62
N
E
P
L(mH)
0.033 F
L
Value
LINE
Current
Rating
N'
E'
LOAD
Insertion loss in dB (50 Ohm circuit)
P'
L(mH)
120 VAC
100 VAC
240 VAC
220 VAC
78
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com