2108i MODEL EUROTHERM ON TROL S Model 2108i 1/8 DIN (96 x 48mm) Indicator and Alarm Unit Ideal for: • Temperature indication • Process indication • Over-temperature protection • Process value trip unit The 2108i provides accurate measurement and display of temperature and other process variables in a standard 1/8 DIN panel format. Two alarm relay outputs are provided for operator alert and process protection. A universal input allows selection of nine internally stored thermocouple types. Other input linearisations may be factory downloaded. Linear, process inputs are scaleable to the desired display range. Keylock and passwords prevent unauthorised access to configuration and alarm settings. A large, red or green LED display gives good visibility in low and high ambient lighting. New alarms can be acknowledged and old alarms reset by a front panel button or an external contact closure input. Three internal alarm setpoints are provided. They are configurable as high, or low, or rate of change alarms. Any combination of the three internal alarms can activate the two relay outputs. Latching or non-latching operation can be selected and alarm delays can be applied. A special mode known as ‘alarm blocking’ is available. In this mode, after power on, the process value must first enter a good state before the alarm becomes active. This is particularly useful for low alarms which can be ‘blocked’ while the process is warming-up. Calibration accuracy is preserved with a self-correcting input circuit, while a User Calibration facility allows offsets to be applied to compensate for sensor and other system errors. Features: • Universal input Covers a wide range of temperature and process inputs • Two alarm relay outputs For operator alert and plant protection • Wide-range 85-264V ac, supply Can be installed world-wide • Plug-in from front Rapid replacement - reducing downtime • Front panel configuration Easy, on-site set-up • Tactile buttons Friendly operation • Three year warranty Low ownership cost Indicator and Alarm Unit Dimensions Specifications ε 48 mm (1.89in) E U R O T H E R M Display: 4 digit, red or green. 15.9mm high characters 103 mm (4.01in) 96 mm (3.78in) Supply voltage: 100 to 240Vac -15%, +10% 2108i OP1 Operating ambients: 0-55°C, 5-95%RH non-condensing OP2 ACK/ RESET Panel sealing: IP54, plug-in from front panel Relay ratings: 2A, 240Vac resistive Panel cut-out - 0.0 + 0.6 45 - 0.0 + 0.8 x 92 1.77 Calibration accuracy: ±0.25% of reading, or ±1°C, or ±1LSD whichever is the greater mm -0 + 0.03 -0 + 0.02 x 3.62 in Cold junction compensation: >15 to 1 rejection of ambient temperature change Electrical connections Input filtering: Off-999.9 seconds Relay Output 2 3C EMC standards: EN50081-2 and EN50082-2 generic standards for industrial environments Model 2108i 3A 3B Safety standard: Meets EN61010, installation category II. Pollution degree 2 Relay Output 1 Sensor inputs V- V+ VI AC AB AA LC LB LA Atmospheres: Not suitable for use above 2000m or in explosive or corrosive atmospheres L N Neutral Ground Line 85-264Vac T/C PT100 Link for keylock Alarm acknowledge/reset mA Input 2.49Ω Ordering Code Model Number Function 2108i AL Function AL Alarm unit Display Colour GN RD Green Red Supply Voltage VH 85-264Vac Display Colour Relay Output 1 RF Unconfigured Non-latched alarm FH High alarm 1 FL Low alarm 1 AL High alarm 1 & low alarm 3 RA Rate of change alarm 1 Latched alarm HA High alarm 1 LA Low alarm 1 AA High alarm 1 & low alarm 3 RT Rate of change alarm 1 NW New alarm status Supply Voltage Relay Output 1 Relay Output 2 Manual VH Relay Output 2 RF Unconfigured Non-latched alarm FH High alarm 2 FL Low alarm 2 RA Rate of change alarm 2 Latched alarm HA High alarm 2 LA Low alarm 2 RT Rate of change alarm 2 NW New alarm status Manual XX ENG FRA GER NED SPA SWE ITA No manual English French German Dutch Spanish Swedish Italian Sensor Input Sensor Input Setpoint Min. Setpoint Max. note 1 note 1 Input Adaptor Units Setpoint Min/Max Standard Sensor Inputs Min °C Max J J Thermocouple -210 to 1200 K K Thermocouple -200 to 1372 T T Thermocouple -200 to 400 L L Thermocouple -200 to 900 N N Thermocouple-Nicrosil/Nisil -200 to 1300 R R Thermocouple-Pt/Pt13%Rh -50 to 1768 S S Thermocouple-Pt/Pt10%Rh -50 to 1768 B B Thermocouple-Pt/Pt30%Rh-6%Rh 0 to 1820 P Platinell II Thermocouple 0 to 1369 Z RTD/PT100 DIN 43760 -200 to 850 Factory Downloaded Input Min °C Max C C Thermocouple - W5%Re/W26%Re(Hoskins) 0 to 2319 D D Thermocouple - W3%Re/W25%Re 0 to 2399 E E Thermocouple -200 to 1000 1 Ni/Ni18%Mo Thermocouple 0 to 1399 2 Pt20%Rh/Pt40%Rh Thermocouple 0 to 1870 3 W/W26%Re (Engelhard) Thermocouple 0 to 2000 4 W/W26%Re (Hoskins) Thermocouple 0 to 2010 5 W5%Re/W26%Re (Engelhard) Thermocouple 10 to 2300 6 W5%Re/W26%Re (Bucose) Thermocouple 0 to 2000 7 Pt10%Rh/Pt40%Rh Thermocouple 200 to 1800 8 Exergen K80 I.R. pyrometer -45 to 650 Process Inputs (Scaled to setpoint min and max) Min Max M -9.99 to +80mV linear -1999 to 9999 Y 0 to 20mA linear (note 2) -1999 to 9999 A 4 to 20mA linear (note 2) -1999 to 9999 V 0 to 10Vdc linear (Input Adapter required) -1999 to 9999 Units C F K X °C °F Kelvin Linear input Input Adaptor XX Not fitted V1 0-10Vdc A1 0-20mA current sense resistor (2.49Ω 0.1%) Note 1. Setpoint min and max: include the decimal points required in the display value; up to one for temperature inputs, up to two for process inputs. Note 2. A 1% 2.49Ω current sense resistor is supplied as standard. If greater accuracy is required a 0.1% resistor can be specified in the input adaptor field. EUROTHERM CONTROLS LIMITED http://www.eurotherm.co.uk UK SALES OFFICE Eurotherm Controls Limited. Faraday Close, Durrington, Worthing, West Sussex BN13 3PL Telephone Sales: (01903) 695888; Technical: (01903) 695777; Service: (01903) 695444 Fax (01903) 695666 Sales and support in over 30 countries worldwide Enquiries/orders to: Eurotherm Controls Limited Export Dept., Faraday Close, Durrington, Worthing. West Sussex BN13 3PL. Telephone (01903) 268500 Fax (01903) 265982 © Copyright Eurotherm Controls Limited 1998 All rights strictly reserved. No part of this document may be stored in a retrieval system, or any form or by any means without prior written permission from Eurotherm Controls Limited. Every effort has been taken to ensure the accuracy of this specification. However in order to maintain our technological lead we are continuously improving our products which could, without notice, result in amendments or omissions to this specification. We cannot accept responsibility for damage, injury, loss or expenses resulting therefrom. Part No. HA026159 Issue 3