MEANWELL LPV

L P V- 6 0
60W Single Output Switching Power Supply
series
Features :
Constant voltage design
Universal AC input / Full range
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Fully encapsulated with IP67 level (Note.8)
Fully isolated plastic case
Class
power unit, no FG
Class 2 power unit
Pass LPS
Suitable for LED lighting and moving sign applications (Note.7)
100% full load burn-in test
Low cost, high reliability
2 years warranty
LPS IP67
SPECIFICATION
MODEL
OUTPUT
LPV-60-5
LPV-60-12
LPV-60-15
LPV-60-24
LPV-60-36
5V
12V
15V
24V
36V
48V
RATED CURRENT
8A
5A
4A
2.5A
1.67A
1.25A
CURRENT RANGE
0 ~ 8A
0 ~ 5A
0 ~ 4A
0 ~ 2.5A
0 ~ 1.67A
0 ~ 1.25A
RATED POWER
40W
60W
60W
60W
60W
60W
120mVp-p
120mVp-p
150mVp-p
150mVp-p
150mVp-p
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE TOLERANCE Note.3
8.0%
LINE REGULATION
1.0%
SETUP, RISE TIME
VOLTAGE RANGE
5.0%
6.0%
2.0%
50ms/230VAC
Note.4 90 ~ 264VAC
16ms/115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
76%
AC CURRENT (Typ.)
INRUSH CURRENT(max.)
1.2A/115VAC 1A/230VAC
COLD START 30A/115VAC
LEAKAGE CURRENT
0.25mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
83%
83%
86%
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
PACKING
NOTE
55.2 ~ 64.8V
-30 ~ +70
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48),
CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), IP67 approved ; design refer to TUV EN60950-1
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
DIMENSION
41.4 ~ 48.6V
Protection type : Shut down o/p voltage, re-power on to recover
I/P-O/P:3KVAC
MTBF
86%
110 ~ 150% rated output power
EMC
ISOLATION RESISTANCE
86%
60A/230VAC
SAFETY & WITHSTAND VOLTAGE
EMC EMISSION
EMC IMMUNITY
LPV-60-48
Note.6 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V)
HOLD UP TIME (Typ.)
OTHERS
( except for 5V,48V )
DC VOLTAGE
LOAD REGULATION
INPUT
( for 48V only)
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
732Khrs min. MIL-HDBK-217F (25 )
162.5*42.5*32mm (L*W*H)
0.4Kg; 32pcs/13.8Kg/0.56CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
File Name:LPV-60-SPEC 2012-03-20
L P V- 6 0
60W Single Output Switching Power Supply
Mechanical Specification
Case No. 976A
162.5
600 30
series
Unit:mm
600 30
3.5
3.6
42.5
15
UL1015 18AWG
AC/N(Blue)
AC/L(Brown)
3.6
81.5
T case
3.5
3.5
UL1007 16AWG
+V(Red)
-V(Black)
3.5
32
T case: Max. Case Temperature.
Recommend Mounting Direction
Block Diagram
fosc : 65KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
O.L.P.
+V
-V
DETECTION
CIRCUIT
PWM
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
100
230VAC
90
80
80
70
115VAC
LOAD (%)
LOAD (%)
60
40
20
-30
-15
0
15
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
264
INPUT VOLTAGE (V) 60Hz
File Name:LPV-60-SPEC 2012-03-20