LINER LTC6802IG-1

LTC6802-1
Multicell
Battery Stack Monitor
FEATURES
DESCRIPTION
n
The LTC®6802-1 is a complete battery monitoring IC that
includes a 12-bit ADC, a precision voltage reference, a
high voltage input multiplexer and a serial interface. Each
LTC6802-1 can measure up to 12 series connected battery cells with an input common mode voltage up to 60V.
In addition, multiple LTC6802-1 devices can be placed in
series to monitor the voltage of each cell in a long battery
string. The unique level-shifting serial interface allows the
serial ports of these devices to be daisy-chained without
optocouplers or isolators.
n
n
n
n
n
n
n
n
n
n
n
Measures up to 12 Li-Ion Cells in Series (60V Max)
Stackable Architecture Enables >1000V Systems
0.25% Maximum Total Measurement Error
13ms to Measure All Cells in a System
Cell Balancing:
On-Chip Passive Cell Balancing Switches
Provision for Off-Chip Passive Balancing
Two Thermistor Inputs Plus On-Board
Temperature Sensor
1MHz Daisy-Chainable Serial Interface
High EMI Immunity
Delta Sigma Converter with Built-In Noise Filter
Open Wire Connection Fault Detection
Low Power Modes
44-Lead SSOP Package
APPLICATIONS
n
n
n
n
When multiple LTC6802-1 devices are connected in series
they can operate simultaneously, permitting all cell voltages
in the stack to be measured within 13ms.
To minimize power, the LTC6802-1 offers a measure mode,
which simply monitors each cell for overvoltage and undervoltage conditions. A standby mode is also provided.
Each cell input has an associated MOSFET switch for
discharging overcharged cells.
Electric and Hybrid Electric Vehicles
High Power Portable Equipment
Backup Battery Systems
High Voltage Data Acquisition Systems
For large battery stack applications requiring individually
addressable serial communications, see the LTC6802-2.
L, LT, LTC, LTM, Linear Technology and the Linear logo are registered trademarks of Linear
Technology Corporation. All other trademarks are the property of their respective owners.
TYPICAL APPLICATION
NEXT 12-CELL
PACK ABOVE
Measurement Error Over
Extended Temperature
LTC6802-1 SERIAL DATA
TO LTC6802-1
ABOVE
DIE TEMP
+
V
0.30
0.25
12-CELL
BATTERY
STRING
MEASUREMENT ERROR (%)
REGISTERS
AND
CONTROL
MUX
12-BIT
Δ∑ ADC
7 REPRESENTATIVE
UNITS
0.20
0.15
0.10
0.05
0
–0.05
–0.10
–0.15
–0.20
V–
NEXT 12-CELL
PACK BELOW
EXTERNAL
TEMP
–0.25
VOLTAGE
REFERENCE
SERIAL DATA
TO LTC6802-1
BELOW
68021 TA01a
–0.30
–50
–25
0
25
50
75
TEMPERATURE (°C)
100
125
68021 TA01b
100k
100k NTC
68021fa
1
LTC6802-1
ABSOLUTE MAXIMUM RATINGS
PIN CONFIGURATION
(Note 1)
TOP VIEW
Total Supply Voltage (V+ to V–) .................................60V
Input Voltage (Relative to V–)
C1 ............................................................ –0.3V to 9V
C12 .......................................... V+ – 0.6V to V+ + 0.3V
Cn (Note 5) ......................... –0.3V to min (9 • n, 60V)
Sn (Note 5) ......................... –0.3V to min (9 • n, 60V)
CSBO, SCKO, SDOI .................. V+ – 0.6V to V+ + 0.3V
All other pins ........................................... –0.3V to 7V
Voltage Between Inputs
Cn to Cn-1 ................................................ –0.3V to 9V
Sn to Cn-1 ................................................ –0.3V to 9V
C12 to C8 ............................................... –0.3V to 25V
C8 to C4 ................................................. –0.3V to 25V
C4 to V– ................................................. –0.3V to 25V
Operating Temperature Range .................–40°C to 85°C
Specified Temperature Range ..................–40°C to 85°C
Junction Temperature ........................................... 150°C
Storage Temperature Range .................. –65°C to 150°C
*n = 1 to 12
CSBO
1
44 CSBI
SDOI
2
43 SDO
SCKO
3
42 SDI
V+
4
41 SCKI
C12
5
40 VMODE
S12
6
39 GPIO2
C11
7
38 GPIO1
S11
8
37 WDTB
C10
9
36 MMB
S10 10
35 TOS
C9 11
34 VREG
S9 12
33 VREF
C8 13
32 VTEMP2
S8 14
31 VTEMP1
C7 15
30 NC
S7 16
29 V–
C6 17
28 S1
S6 18
27 C1
C5 19
26 S2
S5 20
25 C2
C4 21
24 S3
S4 22
23 C3
G PACKAGE
44-LEAD PLASTIC SSOP
TJMAX = 150°C, θJA = 70°C/W
ORDER INFORMATION
LEAD FREE FINISH
TAPE AND REEL
PART MARKING
PACKAGE DESCRIPTION
TEMPERATURE RANGE
LTC6802IG-1#PBF
LTC6802IG-1#TRPBF
LTC6802G-1
44-Lead Plastic SSOP
–40°C to 85°C
Consult LTC Marketing for parts specified with wider operating temperature ranges.
Consult LTC Marketing for information on non-standard lead based finish parts.
For more information on lead free part marking, go to: http://www.linear.com/leadfree/
For more information on tape and reel specifications, go to: http://www.linear.com/tapeandreel/
68021fa
2
LTC6802-1
ELECTRICAL CHARACTERISTICS
The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C. V+ = 43.2V, V– = 0V, unless otherwise noted.
SYMBOL PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
DC Specifications
VACC
VERR
VCELL
VCM
VREF
Measurement Resolution
Quantization of the ADC
l
ADC Offset Voltage
(Note 2)
l
–0.5
0.5
mV
ADC Gain Error
(Note 2)
l
–0.12
–0.22
0.12
0.22
%
%
Total Measurement Error
(Note 4)
VCELL = 0V
VCELL = 2.3V
VCELL = 2.3V
VCELL = 3.6V
VCELL = 3.6V
VCELL = 4.2V
VCELL = 4.2V
VCELL = 4.6V
VTEMP = 2.3V
VTEMP = 3.6V
VTEMP = 4.2V
1.5
0.8
l
–2.8
–5.1
–4.3
–7.9
–5
–9.2
l
l
l
–5.1
–7.9
–9.2
l
l
Cell Voltage Range
Full Scale Voltage Range
Common Mode Voltage Range Measured
Relative to V–
Range of Inputs CN for <0.25% Gain Error, N = 3 to 11 l
l
Range of Input C3 for <1% Gain Error
l
Range of Input C2 for <0.25% Gain Error
l
Range of Input C1 for <0.25% Gain Error
2.8
5.1
4.3
7.9
5
9.2
±8
5.1
7.9
9.2
5
3.7
1.8
1.2
0
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
V
5•N
15
10
5
V
V
V
V
Overvoltage (OV) Detection Level
Programmed for 4.2V
l
4.182
4.200
4.218
V
Undervoltage (UV) Detection Level
Programmed for 2.3V
l
2.290
2.300
2.310
V
l
3.020
3.015
3.065
3.065
Die Temperature Measurement Error
Error in Measurement at 125°C
Reference Pin Voltage
RLOAD = 100k to V–
3
Reference Voltage Temperature Coefficient
Reference Voltage Thermal Hysteresis
Regulator Pin Voltage
°C
3.110
3.115
8
25°C to 85°C and 25°C to –40°C
ppm
60
10 < V+ < 50, No Load
ILOAD = 4mA
Regulator Pin Short Circuit Current Limit
l
l
4.5
4.1
5.0
4.8
l
5
8
VS
Supply Voltage, V+ Relative to V–
VERR Specifications Met
Timing Specifications Met
l
l
10
4
IB
Input Bias Current
In/Out of Pins C1 Thru C12
When Measuring Cells
When Not Measuring Cells
l
–10
IS
Supply Current, Active
Current Into the V+ Pin when Measuring Voltages
with the ADC
IM
Supply Current, Monitor Mode
Average Current Into the V+ Pin While Monitoring
for UV and OV Conditions
Continuous Monitoring (CDC = 2)
Monitor Every 130ms (CDC = 5)
Monitor Every 500ms (CDC = 6)
Monitor Every 2s (CDC = 7)
IQS
Supply Current, Idle
Current into the V+ Pin When Idle
All Serial Port Pins at Logic ‘1’
ICS
Supply Current, Serial I/O
All Serial Port Pins at Logic ‘0’ VMODE = 0, This
Current is Added to IS or IQS
ppm/√khr
5.5
0.8
50
50
V
V
10
μA
nA
1.1
1.2
mA
mA
800
225
150
100
l
35
30
l
3
60
V
V
mA
1
l
V
V
ppm/°C
100
Reference Voltage Long Term Drift
VREG
mV/Bit
μA
μA
μA
μA
80
85
μA
μA
4.5
mA
68021fa
3
LTC6802-1
ELECTRICAL CHARACTERISTICS
The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C. V+ = 43.2V, V– = 0V, unless otherwise noted.
SYMBOL PARAMETER
Discharge Switch On-Resistance
CONDITIONS
MIN
l
VCELL > 3V (Note 3)
l
Temperature Range
TYP
MAX
10
20
Ω
85
°C
–40
Thermal Shutdown Temperature
Thermal Shutdown Hysteresis
UNITS
145
°C
5
°C
Voltage Mode Timing Specifications
Measurement Cycle Time
t1
SDI Valid to SCKI Rising Setup
l
10
ns
t2
SDI Valid to SCKI Rising Hold
l
250
ns
t3
SCKI Low
l
400
ns
t4
SCKI High
l
400
ns
t5
CSBI Pulse Width
l
400
ns
t6
SCKI Rising to CSBI Rising
l
100
ns
t7
CSBI Falling to SCKI Rising
l
100
ns
SCKI Falling to SDO Valid
l
250
Clock Frequency
l
1
Watchdog Timer Time Out Period
l
t8
Time Required to Measure 11 or 12 Cells
Time Required to Measure Up to 10 Cells
Time Required to Measure 1 Cell
l
l
tCYCLE
11
9.2
1
13
11
1.2
1
16
13.5
1.5
ms
ms
ms
ns
MHz
2.5
s
Timing Specifications
tPD1
CSBI to CSBO
CCSBO = 150pF
l
600
ns
tPD2
SCKI to SCKO
CSCKO = 150pF
l
300
ns
tPD3
SDI to SDOI Write Delay
CSDOI = 150pF
l
300
ns
CSDO = 150pF
l
300
ns
tPD4
SDOI to SDI Read Delay
Voltage Mode Digital I/O Specifications
VIH
Digital Input Voltage High
Pins SCKI, SDI, and CSBI
l
VIL
Digital Input Voltage Low
Pins SCKI, SDI, and CSBI
l
0.8
V
VOL
Digital Output Voltage Low
Pin SDO; Sinking 500μA
l
0.3
V
Pins CSBI, SCKI, and SDI (Write)
l
10
μA
2
V
Current Mode Digital I/O Specifications
IIH1
Digital Input Current High
IIL1
Digital Input Current Low
Pins CSBI, SCKI, and SDI (Write)
l
IIH2
Digital Input Current High
Pin SDOI (Read)
l
IIL2
Digital Input Current Low
Pin SDOI (Read)
l
IOH1
Digital Output Current High
Pins CSBO, SCKO, and SDOI (Write)
l
1000
μA
–1000
–10
μA
μA
3
10
μA
IOL1
Digital Output Current Low
Pins CSBO, SCKO, and SDOI (Write)
l
1000
1200
1650
μA
IOH2
Digital Output Current High
Pin SDI (Read)
l
–1650
–1200
–1000
μA
IOL2
Digital Output Current Low
Pin SDI (Read)
l
–10
–3
0
μA
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: The ADC specifications are guaranteed by the Total Measurement
Error (VERR) specification.
Note 3: Due to the contact resistance of the production tester, this
specification is tested to relaxed limits. The 20Ω limit is guaranteed by
design.
Note 4: VCELL refers to the voltage applied across the following pin
combinations: Cn to Cn-1 for n = 2 to 12, C1 to V–. VTEMP refers to the
voltage applied from VTEMP1 or VTEMP2 to V–.
Note 5: These absolute maximum ratings apply provided that the voltage
between inputs do not exceed their absolute maximum ratings.
68021fa
4
LTC6802-1
TYPICAL PERFORMANCE CHARACTERISTICS
Cell Measurement Total
Unadjusted Error
vs Input Resistance
Cell Measurement Total
Unadjusted Error
TOTAL UNADJUSTED ERROR (mV)
TOTAL UNADJUSTED ERROR (mV)
6
4
2
0
–2
–4
–6
–8
–10
0
25
10
TA = –40°C
TA = 25°C
TA = 85°C
TA = 125°C
8
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
CELL VOLTAGE (V)
20
–10
–20
–30
–40
RS = 1k
RS = 2k
RS = 5k
RS = 10k
–60
RS IN SERIES WITH CN AND CN-1
–70 NO EXTERNAL CAPACITANCE ON
CN AND CN-1
–80
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
CELL VOLTAGE (V)
–50
5
0
–250 –200 –150 –100 –50 0 50 100 150 200
CHANGE IN GAIN ERROR (ppm)
68021 G03
ADC Normal Mode Rejection
vs Frequency
0
0
VCM(IN) = 5VP-P
72dB REJECTION
–10 CORRESPONDS TO
LESS THAN 1 BIT
–20 AT ADC OUTPUT
REJECTION (db)
14
12
10
8
6
–10
–20
REJECTION (db)
TA = –45°C TO 25°C
16
NUMBER OF UNITS
10
Cell Measurement Common Mode
Rejection
Measurement Gain Error
Hysteresis
18
15
68021 G02
68021 G01
20
TA = 85°C TO 25°C
0
NUMBER OF UNITS
10
Measurement Gain Error
Hysteresis
–30
–40
–30
–40
–50
–50
–60
–60
4
2
0
–250 –200 –150 –100 –50 0 50 100 150 200
CHANGE IN GAIN ERROR (ppm)
–70
10
100
1k
10k 100k
FREQUENCY (Hz)
1M
68021 G04
ADC INL
1.5
0.8
C PIN BIAS CURRENT (nA)
DNL (BITS)
INL (BITS)
40
0.2
0
–0.2
–0.4
–1.0
–0.6
–1.5
–0.8
–2.0
–1.0
1
3
2
INPUT (V)
4
5
68021 G07
100k
Cell Input Bias Current in Standby
0.4
–0.5
1k
10k
FREQUENCY (Hz)
50
0.6
1.0
0
100
68021 G06
ADC DNL
1.0
0.5
10
68021 G05
2.0
0
–70
10M
30
C1
20
C12
10
0
C2 TO C11
0
1
3
2
INPUT (V)
4
5
68021 G08
–10
–40 –20
0
20 40 60 80
TEMPERATURE (°C)
100 120
68021 G09
68021fa
5
LTC6802-1
TYPICAL PERFORMANCE CHARACTERISTICS
Supply Current
vs Supply Voltage Standby
Cell Input Bias Current During
Conversion
60
CELL INPUT = 3.6V
STANDBY SUPPLY CURRENT (μA)
C PIN BIAS CURRENT (μA)
2.65
2.60
2.55
2.50
2.45
2.40
2.35
–40 –20
50
20 40 60 80
TEMPERATURE (°C)
40
TA = –40°C
30
20
TA = 25°C
10
100 120
0
10
20
30
40
SUPPLY VOLTAGE (V)
50
1
0
–1
–2
DEVICE IN STANDBY PRIOR TO
MAKING DIE MEASUREMENTS
TO MINIMIZE SELF-HEATING
–4
–5
–50
0.60
60
–25
0
25
50
75 100
AMBIENT TEMPERATURE (°C)
10
0
20
30
40
SUPPLY VOLTAGE (V)
50
3.070
3.068
3.066
0
–5
–10
3.064
3.062
3.060
–15
–20
125
VREF Output Voltage
vs Temperature
TA = –40°C
TA = 25°C
TA = 85°C
TA = 105°C
5
3.058
0
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
TEMPERATURE INPUT VOLTAGE (V)
68021 G13
5 REPRESENTATIVE UNITS
3.056
25
75
–50 –25
0
50
TEMPERATURE (°C)
VREF Load Regulation
VREF Line Regulation
3.074
125
VREG Load Regulation
5.4
NO EXTERNAL LOAD ON VREF, CDC = 2
(CONTINUOUS CELL CONVERSIONS)
3.072
100
68021 G15
68021 G14
3.09
60
68021 G12
VREF (V)
2
TOTAL UNADJUSTED ERROR (mV)
DIFFERENCE BETWEEN INTERNAL DIE TEMPERATURE
MEASUREMENT AND AMBIENT TEMPERATURE (°C)
10
VS = 43.2V
–3
TA = –40°C
0.70
External Temperature
Measurement Total Unadjusted
Error vs Input
3
TA = 25°C
0.75
68021 G11
Internal Die Temperature
Measurement
vs Ambient Temperature
4
TA = 85°C
0.80
0.65
68021 G10
5
CDC = 2 (CONTINUOUS
CELL CONVERSIONS)
0.85
TA = 85°C
0
0
0.90
SUPPLY CURRENT (mA)
2.70
Supply Current
vs Supply Voltage in CDC = 2
5.2
3.08
TA = 85°C
TA = 25°C
3.06
TA = 25°C
3.068
TA = 85°C
3.066
TA = –40°C
3.064
TA = –40°C
VREG (V)
3.07
VREF (V)
VREF (V)
3.070
5.0
TA = 85°C
4.8
TA = 25°C
4.6
TA = –40°C
4.4
3.05
3.062
3.04
0
10
100
SOURCING CURRENT (μA)
1000
68021 G16
3.060
4.2
0
10
20
30
40
SUPPLY VOLTAGE (V)
50
60
68021 G17
4.0
0
1
2
3 4 5 6 7 8
SUPPLY CURRENT (mA)
9
10
68021 G18
68021fa
6
LTC6802-1
TYPICAL PERFORMANCE CHARACTERISTICS
Internal Discharge Resistance
vs Cell Voltage
VREG Line Regulation
5.5
50
VREG (V)
DISCHARGE RESISTANCE (Ω)
TA = 85°C
5.0
TA = –40°C
4.5
TA = 25°C
4.0
3.5
3.0
NO EXTERNAL LOAD ON VREG, CDC = 2
(CONTINUOUS CELL CONVERSIONS)
5
15
TA = –45°C
TA = 25°C
TA = 85°C
TA = 105°C
45
25
35
45
SUPPLY VOLTAGE (V)
40
35
30
25
20
15
10
5
0
55
0
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
CELL VOLTAGE (V)
68021 G19
68021 G20
Die Temperature Increase vs
Discharge Current in Internal FET
Cell Conversion Time
13.20
ALL 12 CELLS AT 3.6V
45 VS = 43.2V
TA = 25°C
40
13.15
35
30
12 CELLS
DISCHARGING
25
20
15
6 CELLS
DISCHARGING
1 CELL
DISCHARGING
10
13.10
13.05
13.00
12.95
12.90
12.85
5
0
CONVERSION TIME (ms)
INCREASE IN DIE TEMPERATURE (°C)
50
0
10 20 30 40 50 60 70 80
DISCHARGE CURRENT PER CELL (mA)
68021 G21
12.80
–40 –20
0
20 40 60 80
TEMPERATURE (°C)
100 120
68021 G22
68021fa
7
LTC6802-1
PIN FUNCTIONS
CSBO (Pin 1): Chip Select Output (Active Low). CSBO is
a buffered version of the chip select input, CSBI. CSBO
drives the next IC in the daisy chain. See Serial Port in the
Applications Information section.
SDOI (Pin 2): Serial Data I/O Pin. SDOI transfers data to
and from the next IC in the daisy chain. See Serial Port in
the Applications Information section.
SCKO (Pin 3): Serial Clock Output. SCKO is a buffered version of SCKI. SCKO drives the next IC in the daisy chain.
See Serial Port in the Applications Information section.
V+ (Pin 4): Tie pin 4 to the most positive potential in the
battery stack. Typically V+ is the same potential as C12.
C12, C11, C10, C9, C8, C7, C6, C5, C4, C3, C2, C1 (Pins
5, 7, 9, 11, 13, 15, 17, 19, 21, 23, 25, 27): C1 through
C12 are the inputs for monitoring battery cell voltages.
Up to 12 cells can be monitored. The lowest potential is
tied to pin V–. The next lowest potential is tied to C1 and
so forth. See the figures in the Applications Information
section for more details on connecting batteries to the
LTC6802-1.
The LTC6802-1 can monitor a series connection of up
to 12 cells. Each cell in a series connection must have
a common mode voltage that is greater than or equal to
the cells below it.
S12, S11, S10, S9, S8, S7, S6, S5, S4, S3, S2, S1 (Pins
6, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26, 28): S1 though
S12 pins are used to balance battery cells. If one cell in a
series becomes over charged, an S output can be used to
discharge the cell. Each S output has an internal N-channel
MOSFET for discharging. See the Block Diagram. The NMOS
has a maximum on resistance of 20Ω. An external resistor
should be connected in series with the NMOS to dissipate
heat outside of the LTC6802-1 package. When using the
internal MOSFETs to discharge cells, the die temperature
should be monitored. See Power Dissipation and Thermal
Shutdown in the Applications Information section.
The S pins also feature an internal 10k pull-up resistor. This
allows the S pins to be used to drive the gates of external
P-channel MOSFETs for higher discharge capability.
V– (Pin 29): Connect V– to the most negative potential in
the series of cells.
NC (Pin 30): Pin 30 is internally connected to V– through
10Ω. Pin 30 can be left unconnected or connected to pin
29 on the PCB.
VTEMP1, VTEMP2 (Pins 31, 32): Temperature Sensor Inputs.
The ADC measures the voltage on VTEMPx with respect to
V– and stores the result in the TMP registers. The ADC
measurements are relative to the VREF pin voltage. Therefore
a simple thermistor and resistor combination connected
to the VREF pin can be used to monitor temperature. The
VTEMP inputs can also be general purpose ADC inputs.
VREF (Pin 33): 3.075V Voltage Reference Output. This pin
should be bypassed with a 1μF capacitor. The VREF pin can
drive a 100k resistive load connected to V–. Larger loads
should be buffered with an LT6003 op amp, or similar
device.
VREG (Pin 34): Linear Voltage Regulator Output. This pin
should be bypassed with a 1μF capacitor. The VREG pin is
capable of supplying up to 4mA to an external load. The
VREG pin does not sink current.
TOS (Pin 35): Top of Stack Input. Tie TOS to VREG when
the LTC6802-1 is the top device in a daisy chain. Tie TOS
to V– when the LTC6802-1 is any other device in a daisy
chain. When TOS is tied to VREG, the LTC6802-1 ignores
the SDOI input. When TOS is tied to V–, the LTC6802-1
expects data to be passed to and from the SDOI pin.
MMB (Pin 36): Monitor Mode (Active Low) Input. When
MMB is low (same potential as V–), the LTC6802-1 goes
into monitor mode. See Modes of Operation in the Applications Information section.
WDTB (Pin 37): Watchdog Timer Output (Active Low). If
there is no activity on the SCKI pin for 2.5 seconds, the
WDTB output is asserted. The WDTB pin is an open drain
NMOS output. When asserted it pulls the output down
to V– and resets the configuration register to its default
state. See Watchdog Timer Circuit in the Applications
Information section.
68021fa
8
LTC6802-1
PIN FUNCTIONS
GPIO1, GPIO2 (Pins 38, 39): General Purpose Input/Output. The operation of these pins depends on the state of
the MMB pin.
When MMB is high, the pins behave as traditional GPIOs.
By writing a “0” to a GPIO configuration register bit, the
open drain output is activated and the pin is pulled to V–.
By writing a logic “1” to the configuration register bit, the
corresponding GPIO pin is high impedance. An external
resistor is needed to pull the pin up to VREG.
By reading the configuration register locations GPIO1
and GPIO2, the state of the pins can be determined. For
example, if a “0” is written to register bit GPIO1, a “0” is
always read back because the output NMOSFET pulls pin
38 to V–. If a “1” is written to register bit GPIO1, the pin
becomes high impedance. Either a “1” or a “0” is read
back, depending on the voltage present at pin 38. The
GPIOs makes it possible to turn on/off circuitry around
the LTC6802-1, or read logic values from a circuit around
the LTC6802-1.
When the MMB pin is low, the GPIO pins and the WDTB
pin are treated as inputs that set the number of cells to
be monitored. See Monitor Mode in the Applications
Information section.
VMODE (Pin 40): Voltage Mode Input. When VMODE is tied to
VREG, the SCKI, SDI, SDO, and CSBI pins are configured as
voltage inputs and outputs. This means these pins accept
standard TTL logic levels. Connect VMODE to VREG when
the LTC6802-1 is the bottom device in a daisy chain.
When VMODE is connected to V–, the SCKI, SDI, and CSBI
pins are configured as current inputs and outputs, and SDO
is unused. Connect VMODE to V– when the LTC6802-1 is
being driven by another LTC6802-1 in a daisy chain.
SCKI (Pin 41): Serial Clock Input. The SCKI pin interfaces
to any logic gate (TTL levels) if VMODE is tied to VREG. SCKI
must be driven by the SCKO pin of another LTC6802-1 if
VMODE is tied to V–. See Serial Port in the Applications
Information section.
SDI (Pin 42): Serial Data Input. The SDI pin interfaces to
any logic gate (TTL levels) if VMODE is tied to VREG. SDI
must be driven by the SDOI pin of another LTC6802-1 if
VMODE is tied to V–. See Serial Port in the Applications
Information section.
SDO (Pin 43): Serial Data Output. The SDO pin is an NMOS
open drain output if VMODE is tied to VREG. SDO is not used
if VMODE is tied to V–. See Serial Port in the Applications
Information section.
CSBI (Pin 44): Chip Select (Active Low) Input. The CSBI
pin interfaces to any logic gate (TTL levels) if VMODE is tied
to VREG. CSBI must be driven by the CSBO pin of another
LTC6802-1 if VMODE is tied to V–. See Serial Port in the
Applications Information section.
68021fa
9
LTC6802-1
BLOCK DIAGRAM
4
V+
5
REGULATOR
C12
VREG
34
10k
6
7
S12
WATCHDOG
TIMER
WDTB
C11
SCKO
SDOI
10k
CSBO
24
S3
Δ∑ A/D CONVERTER
MUX
25
12
RESULTS
REGISTER
AND
COMMUNICATIONS
C2
CSBI
SDO
10k
26
SDI
S2
SCKI
27
C1
REFERENCE
VMODE
10k
28
29
GPIO2
CONTROL
S1
NC
GPIO1
MMB
V–
10Ω
30
37
TOS
3
2
1
44
43
42
41
40
39
38
36
35
EXTERNAL
TEMP
DIE
TEMP
VTEMP1
31
VTEMP2
32
VREF
33
68021 BD
68021fa
10
LTC6802-1
TIMING DIAGRAM
Timing Diagram of the Serial Interface
t4
t1
t2
t6
t3
t7
SCKI
D3
SDI
D2
D1
D7 … D4
D0
D3
t5
CSBI
t8
SDO
D4
D3
D2
PREVIOUS COMMAND
D1
D0
D7 … D4
CURRENT COMMAND
D3
68021 TD
OPERATION
THEORY OF OPERATION
The LTC6802-1 is a data acquisition IC capable of measuring the voltage of 12 series connected battery cells.
An input multiplexer connects the batteries to a 12-bit
delta-sigma analog to digital converter (ADC). An internal
10ppm voltage reference combined with the ADC give the
LTC6802-1 its outstanding measurement accuracy. The
inherent benefits of the delta-sigma ADC versus other types
of ADCs (e.g. successive approximation) are explained
in Advantages of Delta-Sigma ADCs in the Applications
Information section.
Communication between the LTC6802-1 and a host processor is handled by a SPI compatible serial interface. As
shown in Figure 1, the LTC6802-1’s can pass data up and
down a stack of devices using simple diodes for isolation.
This operation is described in Serial Port in the Applications Information section.
The LTC6802-1 also contains circuitry to balance cell voltages. Internal MOSFETs can be used to discharge cells.
These internal MOSFETs can also be used to control external
balancing circuits. Figure 1 illustrates cell balancing by
internal discharge. Figure 4 shows the S pin controlling
an external balancing circuit. It is important to note that
the LTC6802-1 makes no decisions about turning on/off
the internal MOSFETs. This is completely controlled by
the host processor. The host processor writes values to
a configuration register inside the LTC6802-1 to control
the switches. The watchdog timer on the LTC6802-1 will
turn off the discharge switches if communication with the
host processor is interrupted.
OPEN CONNECTION DETECTION
When a cell input (C pin) is open, it affects two cell measurements. Figure 2 shows an open connection to C3,
in an application without external filtering between the C
pins and the cells. During normal ADC conversions (that
is, using the STCVAD command), the LTC6802 will give
near zero readings for B3 and B4 when C3 is open. The
zero reading for B3 occurs because during the measurement of B3, the ADC input resistance will pull C3 to the
C2 potential. Similarly, during the measurement of B4, the
ADC input resistance pulls C3 to the C4 potential.
68021fa
11
LTC6802-1
OPERATION
BATTERY
POSITIVE
350V
CSBO
SDOI
SCKO
V+
C12
S12
C11
S11
C10
S10
C9
S9
C8
S8
C7
S7
C6
S6
C5
S5
C4
S4
CSBO
SDOI
SCKO
V+
C12
S12
C11
S11
C10
S10
C9
S9
C8
S8
C7
S7
C6
S6
C5
S5
C4
S4
LTC6802-1
IC #8
CSBI
SDO
SDI
SCKI
BATTERIES #25 TO #84
AND
LTC6802-1 ICs #3 TO #7
CSBO
SDOI
SCKO
V+
C12
S12
C11
S11
C10
S10
C9
S9
C8
S8
C7
S7
C6
S6
C5
S5
C4
S4
VMODE
GPIO2
GPIO1
WDTB
MMB
TOS
VREG
VREF
VTEMP2
VTEMP1
NC
V−
S1
C1
S2
C2
S3
C3
LTC6802-1
IC #1
V2–
OE2
LTC6802-1
IC #2
CSBI
SDO
SDI
SCKI
VMODE
GPIO2
GPIO1
WDTB
MMB
TOS
VREG
VREF
VTEMP2
VTEMP1
NC
V−
S1
C1
S2
C2
S3
C3
3V
V1–
OE1
CS
MISO
MOSI
CLK
CSBI
SDO
SDI
SCKI
V2+
V2–
VMODE
GPIO2
GPIO1
WDTB
MMB
TOS
VREG
VREF
VTEMP2
VTEMP1
NC
V−
S1
C1
S2
C2
S3
C3
V1–
V1+
MPU
MODULE
IO
3V
DIGITAL
ISOLATOR
68021 F01
Figure 1. 96-Cell Battery Stack, Daisy Chain Interface. This is a Simplified Schematic Showing the Basic Multi-IC Architecture
68021fa
12
LTC6802-1
OPERATION
pulled down by the 100μA current source during the B3
cell measurement AND during the B4 cell measurement.
This will tend to decrease the B3 measurement result and
increase the B4 measurement result relative to the normal
STCVAD command. The biggest change is observed in the
B4 measurement when C3 is open. So, the best method to
detect an open wire at input C3 is to look for an increase
in the measurement of the cell connected between inputs
C3 and C4 (cell B4).
LTC6802-1
C4
B4
C3
B3
MUX
C2
C1
V–
100μA
Thus the following algorithm can be used to detect an
open connection to cell pin CN:
68021 F02
Figure 2. Open Connection
(1) Issue a STCVAD command (ADC convert without 100μA
current sources).
LTC6802-1
(2) Issue a RDCV command and store all cell measurements into array CELLA(N).
C4
B4
B3
CF4
CF3
(3) Issue a STOWAD command (ADC convert with 100μA
current sources).
C3
C2
MUX
(4) Issue a RDCV command and store all cell measurements into array CELLB(N).
C1
V–
(5) For each value of N from 1 to 11:
100μA
68021 F03
Figure 3. Open Connection with RC Filtering
Figure 3 shows an open connection at the same point in
the cell stack as Figure 2, but this time there is an external
filter network still connected to C3. Depending on the value
of the capacitor remaining on C3, a normal measurement
of B3 and B4 may not give near-zero readings, since the
C3 pin is not truly open. In fact, with a large external capacitance on C3, the C3 voltage will be charged midway
between C2 and C4 after several cycles of measuring cells
B3 and B4. Thus the measurements for B3 and B4 may
indicate a valid cell voltage when in fact the exact state of
B3 and B4 is unknown.
To reliably detect an open connection, the command
STOWAD is provided. With this command, two 100μA
current sources are connected to the ADC inputs and
turned on during all cell conversions. Referring again to
Figure 3, with the STOWAD command, the C3 pin will be
If CELLB(N+1) – CELLA(N+1) ≥ +200mV, then CN is
open, otherwise it is not open.
The +200mV threshold is chosen to provide tolerance for
errors in the measurement with the 100μA current source
connected. Even without an open connection there is always some difference between a cell measured with and
without the 100μA current source because of the IR drop
across the finite resistance of the MUX switches. On the
other hand, with capacitors larger than 0.1μF remaining
on an otherwise open C pin, the 100μA current source
may not be enough to move the open C pin 200mV with
a single STOWAD command. If the STOWAD command
is repeated several times, the large external capacitor will
discharge enough to create a 200mV change in cell readings. To detect an open connection with larger than 0.1μF
capacitance still on the pin, one must repeat step (3) above
a number of times before proceeding to step (4).
The algorithm above determines if the CN pin is open
based on measurements of the N+1 Cell. For example, in
a 12-cell system, the algorithm finds opens on pins C1
68021fa
13
LTC6802-1
OPERATION
through C11 by looking at the measurements of cells B2
through B12. Therefore the algorithm cannot be used to
determine if the topmost C pin is open. Fortunately, an open
wire from the battery to the top C pin usually means the V+
pin is also floating. When this happens, the readings for
the top battery cell will always be 0V, indicating a failure.
If the top C pin is open yet V+ is still connected, then the
best way to detect an open connection to the top C pin
is by comparing the sum of all cell measurements using
the STCVAD command to an auxiliary measurement of the
sum of all the cells, using a method similar to that shown
in Figure 18. A significantly lower result for the calculated
sum of all 12 cells suggests an open connection to the top
C pin, provided it was already determined that no other
C pin is open.
DISCHARGING DURING CELL MEASUREMENTS
The primary cell voltage A/D measurement commands
(STCVAD and STOWAD) automatically turn off a cell’s
discharge switch while its voltage is being measured. The
discharge switches for the cell above and the cell below will
also be turned off during the measurement. For example,
discharge switches S4, S5, and S6 will be disabled while
cell 5 is being measured.
In some systems it may be desirable to allow discharging
to continue during cell voltage measurements. The cell
voltage A/D conversion commands STCVDC and STOWDC
allow any enabled discharge switches to remain on during
cell voltage measurements. This feature allows the system
to perform a self-test to verify the discharge functionality
and multiplexer operation.
All discharge switches are automatically disabled during
OV and UV comparison measurements.
A/D CONVERTER DIGITAL SELF TEST
Two self test commands can be used to verify the functionality of the digital portions of the ADC. The self tests
also verify the cell voltage registers and temperature
monitoring registers. During these self tests a test signal
is applied to the ADC. If the circuitry is working properly
all cell voltage and temperature registers will contain
identical codes. For Self Test 1 the registers will contain
0x555. For Self Test 2, the registers will contain 0xAAA.
The time required for the self test function is the same as
required to measure all cell voltages or all temperature
sensors. Perform the self test function with CDC[2:0] set
to 1 in the configuration register.
USING THE S PINS AS DIGITAL OUTPUTS OR
GATE DRIVERS
The S outputs include an internal 10k pull-up resistor.
Therefore the S pins will behave as a digital output when
loaded with a high impedance, e.g. the gate of an external
MOSFET. For applications requiring high battery discharge
currents, connect a discrete PMOS switch device and suitable discharge resistor to the cell, and the gate terminal
to the S output pin, as illustrated in Figure 4.
C(n)
SI2351DS
3.3k
15Ω
1W
VISHAY CRCW2512 SERIES
S(n)
C(n – 1)
68021 F04
Figure 4. External Discharge FET Connection (One Cell Shown)
68021fa
14
LTC6802-1
OPERATION
POWER DISSIPATION AND THERMAL SHUTDOWN
The MOSFETs connected to the pins S1 through S12 can be
used to discharge battery cells. An external resistor should
be used to limit the power dissipated by the MOSFETs. The
maximum power dissipation in the MOSFETs is limited by
the amount of heat that can be tolerated by the LTC6802-1.
Excessive heat results in elevated die temperatures. The
electrical characteristics are guaranteed for die temperatures up to 85°C. Little or no degradation will be observed
in the measurement accuracy for die temperatures up
to 105°C. Damage may occur near 150°C, therefore the
recommended maximum die temperature is 125°C.
To protect the LTC6802-1 from damage due to overheating,
a thermal shutdown circuit is included. Overheating of the
device can occur when dissipating significant power in the
cell discharge switches or when communicating frequently
to the device using the current-mode serial interface. The
problem is exacerbated when operating with a large voltage between V+ and V– or when the thermal conductivity
of the system is poor.
If the temperature detected on the device goes above approximately 145°C, the configuration registers will be reset
to default states, turning off all discharge switches and
disabling A/D conversions. When a thermal shutdown has
occurred, the THSD bit in the temperature register group
will go high. The bit is cleared by performing a read of the
temperature registers (RDTMP command).
Since thermal shutdown interrupts normal operation, the
internal temperature monitor should be used to determine
when the device temperature is approaching unacceptable
levels.
68021fa
15
LTC6802-1
APPLICATIONS INFORMATION
USING THE LTC6802-1 WITH LESS THAN 12 CELLS
The LTC6802-1 can typically be used with as few as four
cells. The minimum number of cells is governed by the
supply voltage requirements of the LTC6802-1. The sum
of the cell voltages must be 10V to guarantee that all
electrical specifications are met.
Figure 5 shows an example of the LTC6802-1 when used
to monitor seven cells. The lowest C inputs connect to the
seven cells and the upper C inputs connect to V+. Other
configurations, e.g. 9 cells, would be configured in the
same way: the lowest C inputs connected to the battery
cells and the unused C inputs connected to V+. The unused
inputs will result in a reading of 0V for those channels.
The ADC can also be commanded to measure a stack of
cells by making 10 or 12 measurements, depending on
the state of the CELL10 bit in the control register. Data
from all 10 or 12 measurements must be down loaded
when reading the conversion results. The ADC can be
commanded to measure any individual cell voltage.
NEXT HIGHER GROUP OF 7 CELLS
LTC6802-1
V+
C12
S12
C11
S11
C10
S10
C9
S9
C8
S8
C7
S7
C6
S6
C5
S5
C4
S4
C3
S3
C2
S2
C1
S1
V−
NEXT LOWER GROUP OF 7 CELLS
USING THE GENERAL PURPOSE INPUTS/OUTPUTS
(GPIO1, GPIO2)
The LTC6802-1 has two general purpose digital inputs/outputs. By writing a GPIO configuration register bit to a logic
low, the open drain output can be activated. The GPIOs
give the user the ability to turn on/off circuitry around the
LTC6802-1. One example might be a circuit to verify the
operation of the system.
When a GPIO configuration bit is written to a logic high,
the corresponding GPIO pin may be used as an input.
The read back value of that bit will be the logic level that
appears at the GPIO pin.
When the MMB pin is low, the GPIO pins and the WDTB
pin are treated as inputs that set the number of cells to
be monitored. See the Monitor Mode section.
WATCHDOG TIMER CIRCUIT
The LTC6802-1 includes a watchdog timer circuit. If no
activity is detected on the SCKI pin for 2.5 seconds, the
WDTB open drain output is asserted low. The WDTB pin
remains low until an edge is detected on the SCKI pin.
When the watchdog timer circuit times out, the configuration bits are reset to their default (power-up) state.
In the power-up state, the S outputs are off. Therefore, the
watchdog timer provides a means to turn off cell discharging should communications to the MPU be interrupted.
The IC is in the minimum power standby mode after a
time out. Note that externally pulling the WDTB pin low
will not reset the configuration bits.
The watchdog timer operation is disabled when MMB
is low.
When reading the configuration register, byte CFG0 bit 7
will reflect the state of the WDTB pin.
REVISION CODE
68021 F05
Figure 5. Monitoring 7 Cells with the LTC6802-1
The temperature register group contains a 3-bit revision
code. If software detection of device revision is necessary, then contact the factory for details. Otherwise, the
code can be ignored. In all cases, however, the values of
all bits must be used when calculating the packet error
code (PEC) CRC byte on data reads.
68021fa
16
LTC6802-1
APPLICATIONS INFORMATION
MODES OF OPERATION
The LTC6802-1 has three modes of operation: standby,
measure and monitor. Standby mode is a power saving state
where all circuits except the serial interface are turned off.
In measure mode, the LTC6802-1 is used to measure cell
voltages and store the results in memory. Measure mode
will also monitor each cell voltage for overvoltage (OV)
and undervoltage (UV) conditions. In monitor mode, the
device will only monitor cells for UV and OV conditions.
A signal is output on the SDO pin to indicate the UV/OV
status. The serial interface is disabled in monitor mode.
Standby Mode
The LTC6802-1 defaults (powers up) to standby mode.
Standby mode is the lowest possible supply current state.
All circuits are turned off except the serial interface and the
voltage regulator. For the lowest possible standby current
consumption all SPI logic inputs should be set to a logic
1 level. The LTC6802-1 can be programmed for standby
mode by setting the comparator duty cycle configuration
bits, CDC[2:0], to 0. If the part is put into standby mode
while ADC measurements are in progress, the measurements will be interrupted and the cell voltage registers will
be in an indeterminate state. To exit standby mode, the
CDC bits must be written to a value other than 0.
If fewer than 12 cells are connected to the LTC6802-1
then it is necessary to mask the unused input channels.
The MCxI bits in the configuration registers are used to
mask channels. If the CELL10 bit is high, then the inputs
for cells 11 and 12 are automatically masked.
The LTC6802-1 can monitor UV and OV conditions continuously. Alternatively, the duty cycle of the UV and OV
comparisons can be reduced or turned off to lower the
overall power consumption. The CDC bits are used to
control the duty cycle.
To initiate cell voltage measurements while in measure
mode, a Start A/D Conversion and Poll Status command
must be sent. After the command has been sent, the
LTC6802-1 will send the A/D converter status using either
the toggle polling or the level polling method, as described
in the Serial Port section. If the CELL10 bit is high, then
only the bottom 10 cell voltages will be measured, thereby
reducing power consumption and measurement time. By
default the CELL10 bit is low, enabling measurement of all
12 cell voltages. During cell voltage measurement commands, UV and OV flag conditions, reflected in the flag
register group, are also updated. When the measurements
are complete, the part will go back to monitoring UV and
OV conditions at the rate designated by the CDC bits.
Monitor Mode
Measure Mode
LTC6802-1 is in measure mode when the CDC bits are
programmed with a value from 1 to 7. The IC monitors
each cell voltage and produces an interrupt signal on the
SDO pin indicating all cell voltages are within the UV and
OV limits. There are two methods for indicating the UV/OV
interrupt status: toggle polling (using a 1kHz output signal)
and level polling (using a high or low output signal). The
polling methods are described in the Serial Port section.
The UV/OV limits are set by the VUV and VOV values in
the configuration registers. When a cell voltage exceeds
the UV/OV limits a bit is set in the flag register. The UV
and OV flag status for each cell can be determined using
the Read Flag Register Group.
The LTC6802-1 can be used as a simple monitoring circuit
with no serial interface by pulling the MMB pin low. When
in this mode, the interrupt status is indicated on the SDO
pin using the toggle polling mode described in the Serial
Port section. Unlike serial port polling commands, however, the toggling is independent of the state of the CSBI
pin. See Figure 6.
When the MMB pin is low, all the device configuration
values are reset to the default states shown in Table 12.
When MMB is held low the VUV, VOV, and CDC register
values are ignored. Instead VUV and VOV use factoryprogrammed setings. CDC is set to state 5. The number
of cells to be monitored is set by the logic levels on the
WDTB and GPIO pins, as shown in Table 1.
68021fa
17
LTC6802-1
APPLICATIONS INFORMATION
BATTERY POSITIVE
350V
LTC6802-1
CSBI
SDO
SDI
SCKI
VMODE
GPIO2
GPIO1
WDTB
MMB
TOS
VREG
VREF
VTEMP2
VTEMP1
NC
V−
S1
C1
S2
C2
S3
C3
CSBO
SDOI
SCKO
V+
C12
S12
C11
S11
C10
S10
C9
S9
C8
S8
C7
S7
C6
S6
C5
S5
C4
S4
CSBO
SDOI
SCKO
V+
C12
S12
C11
S11
C10
S10
C9
S9
C8
S8
C7
S7
C6
S6
C5
S5
C4
S4
LTC6802-1
IC #8
CSBI
SDO
SDI
SCKI
VMODE
GPIO2
GPIO1
WDTB
MMB
TOS
VREG
VREF
VTEMP2
VTEMP1
NC
V−
S1
C1
S2
C2
S3
C3
IC #3 TO IC #7
LTC6802-1
CSBI
SDO
SDI
SCKI
VMODE
GPIO2
GPIO1
WDTB
MMB
TOS
VREG
VREF
VTEMP2
VTEMP1
NC
V−
S1
C1
S2
C2
S3
C3
CSBO
SDOI
SCKO
V+
C12
S12
C11
S11
C10
S10
C9
S9
C8
S8
C7
S7
C6
S6
C5
S5
C4
S4
CSBO
SDOI
SCKO
V+
C12
S12
C11
S11
C10
S10
C9
S9
C8
S8
C7
S7
C6
S6
C5
S5
C4
S4
LTC6802-1
IC #2
CSBI
SDO
SDI
SCKI
VMODE
GPIO2
GPIO1
WDTB
MMB
TOS
VREG
VREF
VTEMP2
VTEMP1
NC
V−
S1
C1
S2
C2
S3
C3
3V
LTC6802-1
CSBI
SDO
SDI
SCKI
VMODE
GPIO2
GPIO1
WDTB
MMB
TOS
VREG
VREF
VTEMP2
VTEMP1
NC
V−
S1
C1
S2
C2
S3
C3
CSBO
SDOI
SCKO
V+
C12
S12
C11
S11
C10
S10
C9
S9
C8
S8
C7
S7
C6
S6
C5
S5
C4
S4
CSBO
SDOI
SCKO
V+
C12
S12
C11
S11
C10
S10
C9
S9
C8
S8
C7
S7
C6
S6
C5
S5
C4
S4
LTC6802-1
IC #1
V2−
OE2
V1−
OE1
MPU
VMODE
GPIO2
GPIO1
WDTB
MMB
TOS
VREG
VREF
VTEMP2
VTEMP1
NC
V−
S1
C1
S2
C2
S3
C3
MODULE
IO
CS
MISO
MOSI
CLK
CSBI
SDO
SDI
SCKI
V2+
V2−
V1−
V1+
DIGITAL
ISOLATOR
3V
68021 F06
Figure 6. Redundant Monitoring Circuit. This is a Simplified Schematic to Show the General Architecture
68021fa
18
LTC6802-1
APPLICATIONS INFORMATION
Table 1. Monitor Mode Cell Selection
WDTB
GPIO2
GPIO1
CELL INPUTS MONITORED
0
0
0
Cells 1 to 5
0
0
1
Cells 1 to 6
0
1
0
Cells 1 to 7
0
1
1
Cells 1 to 8
1
0
0
Cells 1 to 9
1
0
1
Cells 1 to 10
1
1
0
Cells 1 to 11
1
1
1
Cells 1 to 12
If MMB is low then brought high, all device configuration
values are reset to the default states including the VUV,
VOV, and CDC configuration bits.
SERIAL PORT
Overview
The LTC6802-1 has an SPI bus compatible serial port.
Several devices can be daisy chained in series.
There are two sets of serial port pins, designated as low
side and high side. The low side and high side ports enable
devices to be daisy chained even when they operate at different power supply potentials. In a typical configuration,
the positive power supply of the first, bottom device is
connected to the negative power supply of the second, top
device, as shown in Figure 1. When devices are stacked in
this manner, they can be daisy chained by connecting the
high side port of the bottom device to the low side port of
the top device. With this arrangement, the master writes to
or reads from the cascaded devices as if they formed one
long shift register. The LTC6802-1 translates the voltage
level of the signals between the low side and high side
ports to pass data up and down the battery stack.
Physical Layer
On the LTC6802-1, seven pins comprise the low side and
high side ports. The low side pins are CSBI, SCKI, SDI,
and SDO. The high side pins are CSBO, SCKO and SDOI.
CSBI and SCKI are always inputs, driven by the master
or by the next lower device in a stack. CSBO and SCKO
are always outputs that can drive the next higher device
in a stack. SDI is a data input when writing to a stack of
devices. For devices not at the bottom of a stack, SDI is a
data output when reading from the stack. SDOI is a data
output when writing to and a data input when reading from
a stack of devices. SDO is an open drain output that is only
used on the bottom device of a stack, where it may be tied
with SDI, if desired, to form a single, bi-directional port.
The SDO pin on the bottom device of a stack requires a
pull-up resistor. For devices up in the stack, SDO should
be tied to the local V– or left floating.
To communicate between daisy-chained devices, the
high side port pins of a lower device (CSBO, SCKO, and
SDOI) must be connected through PN junction diodes to
the respective low side port pins of the next higher device
(CSBI, SCKI, and SDI). In this configuration, the devices
communicate using current rather than voltage. To signal
a logic high from the lower device to the higher device,
the lower device sinks a smaller current from the higher
device pin. To signal a logic low, the lower device sinks
a larger current. Likewise, to signal a logic high from
the higher device to the lower device, the higher device
sources a larger current to the lower device pin. To signal
a logic low, the higher device sources a smaller current.
See Figure 7.
Standby current consumed in the current mode serial interface is minimized when CSBI, SCKI, and SDI are all high.
VSENSE
(WRITE)
+
–
LOW SIDE PORT
ON HIGHER DEVICE
READ 1
WRITE
HIGH SIDE PORT
ON LOWER DEVICE
VSENSE
(READ)
+
–
68021 F07
Figure 7. Current Mode Interface
68021fa
19
LTC6802-1
APPLICATIONS INFORMATION
The voltage mode pin (VMODE) determines whether the low
side serial port is configured as voltage mode or current
mode. For the bottom device in a daisy-chain stack, this
pin must be pulled high (tied to VREG). The other devices
in the daisy chain must have this pin pulled low (tied to V–)
to designate current mode communication. To designate
the top-of-stack device for polling commands, the TOS
pin on the top device of a daisy chain must be tied high.
The other devices in the stack must have TOS tied low.
See Figure 1.
Data Transfers: Every byte consists of 8 bits. Bytes are
transferred with the most significant bit (MSB) first. On a
write, the data value on SDI is latched into the device on
the rising edge of SCKI (Figure 8). Similarly, on a read,
the data value output on SDO is valid during the rising
edge of SCKI and transitions on the falling edge of SCKI
(Figure 9).
Data Link Layer
CSBI must remain low for the entire duration of a command sequence, including between a command byte and
subsequent data. On a write command, data is latched in
on the rising edge of CSBI.
Clock Phase And Polarity: The LTC6802-1 SPI-compatible interface is configured to operate in a system using
CPHA=1 and CPOL=1. Consequently, data on SDI must
be stable during the rising edge of SCKI.
After a polling command has been entered, the SDO output
will immediately be driven by the polling state, with the
SCKI input ignored (Figure 10). See the Toggle Polling
and Level Polling sections.
CSBI
SCKI
SDI
MSB (CMD)
BIT6 (CMD)
LSB (CMD)
MSB (DATA)
LSB (DATA)
68021 F08
Figure 8. Transmission Format (Write)
CSBI
SCKI
SDI
SDO
MSB (CMD)
BIT6 (CMD)
LSB (CMD)
MSB (DATA)
LSB (DATA)
68021 F09
Figure 9. Transmission Format (Read)
68021fa
20
LTC6802-1
APPLICATIONS INFORMATION
CSBI
SCKI
SDI
MSB (CMD)
BIT6 (CMD)
SDO
LSB (CMD)
POLL STATE
68021 F10
Figure 10. Transmission Format (Poll)
Network Layer
Broadcast Commands: A broadcast command is one to
which all devices on the bus will respond. See the Bus
Protocols and Commands sections.
In daisy chained configurations, all devices in the chain
receive the command bytes simultaneously. For example,
to initiate A/D conversions in a stack of devices, a single
STCVAD command byte is sent, and all devices will start
conversions at the same time. For read and write commands, a single command byte is sent, and then the stacked
devices effectively turn into a cascaded shift register, in
which data is shifted through each device to the next higher
(on a write) or the next lower (on a read) device in the
stack. See the Serial Command Examples section.
PEC Byte: The Packet Error Code (PEC) byte is a CRC
value calculated for all of the bits in a register group in
the order they are read, using the following characteristic
polynomial:
x8 + x2 + x + 1
On a read command, after sending the last byte of a register
group, the device will shift out the calculated PEC, MSB
first. For daisy-chained devices, after the PEC is read from
the first device, the data from any daisy-chained devices
will follow in the same order. For example, when reading the flag registers from two stacked devices (bottom
device A and top device B), the data will be output in the
following order:
FLGR0(A), FLGR1(A), FLGR2(A), PEC(A), FLGR0(B),
FLGR1(B), FLGR2(B), PEC(B)
Toggle Polling: Toggle polling allows a robust determination both of device states and of the integrity of the connections between the devices in a stack. Toggle polling
is enabled when the LVLPL bit is low. After entering a
polling command, the data out line will be driven by the
slave devices based on their status. When polling for the
A/D converter status, data out will be low when any device
is busy performing an A/D conversion and will toggle at
1kHz when no device is busy. Similarly, when polling for
interrupt status, the output will be low when any device
has an interrupt condition and will toggle at 1kHz when
none has an interrupt condition.
Toggle Polling—Daisy-Chained Broadcast Polling: The
SDO pin (bottom device) or SDI pin (stacked devices) will
be low if a device is busy/in interrupt. If it is not busy/not
in interrupt, the device will pass the signal from the SDOI
input to data out (if not the top-of-stack device) or toggle
the data out line at 1kHz (if the top-of-stack device).
The master pulls CSBI high to exit polling.
Level polling: Level polling is enabled when the LVLPL
bit is high. After entering a polling command, the data
out line will be driven by the slave devices based on their
status. When polling for the A/D converter status, data
68021fa
21
LTC6802-1
APPLICATIONS INFORMATION
out will be low when any device is busy performing an
A/D conversion and will be high when no device is busy.
Similarly, when polling for interrupt status, the output will
be low when any device has an interrupt condition and will
be high when none has an interrupt condition.
Level polling—Daisy-Chained Broadcast Polling: The SDO
pin (bottom device) or SDI pin (stacked devices) will be
low if a device is busy/in interrupt. If it is not busy/not in
interrupt, the device will pass the level from the SDOI input
to data out (if not the top-of-stack device) or hold the data
out line high (if the top-of-stack device). Therefore, if any
device in the chain is busy or in interrupt, the SDO signal
at the bottom of the stack will be low. If all devices are
not busy/not in interrupt, the SDO signal at the bottom of
the stack will be high.
conversion time to pass before reading the results. The
second method is to hold CSBI low after an A/D start
command has been sent. The A/D conversion status will be
output on SDO. A problem with the second method is that
the controller is not free to do other serial communication
while waiting for A/D conversions to complete. The third
method overcomes this limitation. The controller can send
an A/D start command, perform other tasks, and then
send a Poll A/D Converter Status (PLADC) command to
determine the status of the A/D conversions.
For OV/UV interrupt status, the Poll Interrupt Status (PLINT)
command can be used to quickly determine whether
any cell in a stack is in an overvoltage or undervoltage
condition.
Bus Protocols
The master pulls CSBI high to exit polling.
Polling Methods: For A/D conversions, three methods can
be used to determine A/D completion. First, a controller
can start an A/D conversion and wait for the specified
There are 3 different protocol formats, depicted in Table 3
through Table 5. Table 2 is the key for reading the protocol
diagrams.
Table 2. Protocol Key
PEC
Packet error code (CRC-8)
Master-to-slave
N
Number of bits
Slave-to-master
…
Continuation of protocol
Complete byte of data
Table 3. Broadcast Poll Command
8
Command
Poll Data
Table 4. Broadcast Read
8
8
Command
Data Byte Low
…
8
8
8
Data Byte High
PEC
Shift Byte 1
8
8
Data Byte High
Shift Byte 1
8
…
Shift Byte N
Table 5. Broadcast Write
8
8
Command
Data Byte Low
…
8
…
Shift Byte N
68021fa
22
LTC6802-1
APPLICATIONS INFORMATION
Commands
Table 6. Command Codes
Write Configuration Register Group
WRCFG
0x01
Read Configuration Register Group
RDCFG
0x02
Read Cell Voltage Register Group
RDCV
0x04
Read Flag Register Group
RDFLG
0x06
Read Temperature Register Group
RDTMP
0x08
Start Cell Voltage A/D Conversions and Poll Status
STCVAD
0x10 (all cell voltage inputs)
0x11 (cell 1 only)
0x12 (cell 2 only)
…
0x1A (cell 10 only)
0x1B (cell 11 only, if CELL10 bit=0)
0x1C (cell 12 only, if CELL10 bit=0)
0x1D (unused)
0x1E (cell self test 1; all CV=0x555)
0x1F (cell self test 2; all CV=0xAAA)
Start Open Wire A/D Conversions and Poll Status
STOWAD
0x20 (all cell voltage inputs)
0x21 (cell 1 only)
0x22 (cell 2 only)
…
0x2A (cell 10 only)
0x2B (cell 11 only, if CELL10 bit=0)
0x2C (cell 12 only, if CELL10 bit=0)
0x2D (unused)
0x2E (cell self test 1; all CV=0x555)
0x2F (cell self test 2; all CV=0xAAA)
Start Temperature A/D Conversions and Poll Status
STTMPAD
0x30 (all temperature inputs)
0x31 (external temp 1 only)
0x32 (external temp 2 only)
0x33 (internal temp only)
0x34—0x3D (unused)
0x3E (temp self test 1; all TMP=0x555)
0x3F (temp self test 2; all TMP=0xAAA)
Poll A/D Converter Status
PLADC
0x40
Poll Interrupt Status
PLINT
0x50
Start Cell Voltage A/D Conversions and Poll Status, with
Discharge Permitted
STCVDC
0x60 (all cell voltage inputs)
0x61 (cell 1 only)
0x62 (cell 2 only)
…
0x6A (cell 10 only)
0x6B (cell 11 only, if CELL10 bit=0)
0x6C (cell 12 only, if CELL10 bit=0)
0x6D (unused)
0x6E (cell self test 1; all CV=0x555)
0x6F (cell self test 2; all CV=0xAAA)
Start Open Wire A/D Conversions and Poll Status, with
Discharge Permitted
STOWDC
0x70 (all cell voltage inputs)
0x71 (cell 1 only)
0x72 (cell 2 only)
…
0x7A (cell 10 only)
0x7B (cell 11 only, if CELL10 bit=0)
0x7C (cell 12 only, if CELL10 bit=0)
0x7D (unused)
0x7E (cell self test 1; all CV=0x555)
0x7F (cell self test 2; all CV=0xAAA)
68021fa
23
LTC6802-1
APPLICATIONS INFORMATION
Memory Map
Table 7 through Table 12 show the memory map for the
LTC6802-1. Table 12 gives bit descriptions.
Table 7. Configuration (CFG) Register Group
REGISTER
RD/WR
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
CFGR0
RD/WR
WDT
GPIO2
GPIO1
LVLPL
CELL10
CDC[2]
CDC[1]
CDC[0]
CFGR1
RD/WR
DCC8
DCC7
DCC6
DCC5
DCC4
DCC3
DCC2
DCC1
CFGR2
RD/WR
MC4I
MC3I
MC2I
MC1I
DCC12
DCC11
DCC10
DCC9
CFGR3
RD/WR
MC12I
MC11I
MC10I
MC9I
MC8I
MC7I
MC6I
MC5I
CFGR4
RD/WR
VUV[7]
VUV[6]
VUV[5]
VUV[4]
VUV[3]
VUV[2]
VUV[1]
VUV[0]
CFGR5
RD/WR
VOV[7]
VOV[6]
VOV[5]
VOV[4]
VOV[3]
VOV[2]
VOV[1]
VOV[0]
BIT 3
BIT 2
BIT 1
BIT 0
Table 8. Cell Voltage (CV) Register Group
REGISTER
RD/WR
BIT 7
BIT 6
BIT 5
BIT 4
CVR00
RD
C1V[7]
C1V[6]
C1V[5]
C1V[4]
C1V[3]
C1V[2]
C1V[1]
C1V[0]
CVR01
RD
C2V[3]
C2V[2]
C2V[1]
C2V[0]
C1V[11]
C1V[10]
C1V[9]
C1V[8]
CVR02
RD
C2V[11]
C2V[10]
C2V[9]
C2V[8]
C2V[7]
C2V[6]
C2V[5]
C2V[4]
CVR03
RD
C3V[7]
C3V[6]
C3V[5]
C3V[4]
C3V[3]
C3V[2]
C3V[1]
C3V[0]
CVR04
RD
C4V[3]
C4V[2]
C4V[1]
C4V[0]
C3V[11]
C3V[10]
C3V[9]
C3V[8]
CVR05
RD
C4V[11]
C4V[10]
C4V[9]
C4V[8]
C4V[7]
C4V[6]
C4V[5]
C4V[4]
CVR06
RD
C5V[7]
C5V[6]
C5V[5]
C5V[4]
C5V[3]
C5V[2]
C5V[1]
C5V[0]
CVR07
RD
C6V[3]
C6V[2]
C6V[1]
C6V[0]
C5V[11]
C5V[10]
C5V[9]
C5V[8]
CVR08
RD
C6V[11]
C6V[10]
C6V[9]
C6V[8]
C6V[7]
C6V[6]
C6V[5]
C6V[4]
CVR09
RD
C7V[7]
C7V[6]
C7V[5]
C7V[4]
C7V[3]
C7V[2]
C7V[1]
C7V[0]
CVR10
RD
C8V[3]
C8V[2]
C8V[1]
C8V[0]
C7V[11]
C7V[10]
C7V[9]
C7V[8]
CVR11
RD
C8V[11]
C8V[10]
C8V[9]
C8V[8]
C8V[7]
C8V[6]
C8V[5]
C8V[4]
CVR12
RD
C9V[7]
C9V[6]
C9V[5]
C9V[4]
C9V[3]
C9V[2]
C9V[1]
C9V[0]
CVR13
RD
C10V[3]
C10V[2]
C10V[1]
C10V[0]
C9V[11]
C9V[10]
C9V[9]
C9V[8]
CVR14
RD
C10V[11]
C10V[10]
C10V[9]
C10V[8]
C10V[7]
C10V[6]
C10V[5]
C10V[4]
CVR15*
RD
C11V[7]
C11V[6]
C11V[5]
C11V[4]
C11V[3]
C11V[2]
C11V[1]
C11V[0]
CVR16*
RD
C12V[3]
C12V[2]
C12V[1]
C12V[0]
C11V[11]
C11V[10]
C11V[9]
C11V[8]
CVR17*
RD
C12V[11]
C12V[10]
C12V[9]
C12V[8]
C12V[7]
C12V[6]
C12V[5]
C12V[4]
*Registers CVR15, CVR16, and CVR17 can only be read if the CELL10 bit in register CFGR0 is low
68021fa
24
LTC6802-1
APPLICATIONS INFORMATION
Table 9. Flag (FLG) Register Group
REGISTER
RD/WR
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
FLGR0
RD
C4OV
C4UV
C3OV
C3UV
C2OV
C2UV
C1OV
C1UV
FLGR1
RD
C8OV
C8UV
C7OV
C7UV
C6OV
C6UV
C5OV
C5UV
FLGR2
RD
C12OV*
C12UV*
C11OV*
C11UV*
C10OV
C10UV
C9OV
C9UV
* Bits C11UV, C12UV, C11OV, and C12OV are always low if the CELL10 bit in register CFGR0 is high
Table 10. Temperature (TMP) Register Group
REGISTER
RD/WR
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
TMPR0
RD
ETMP1[7]
ETMP1[6]
ETMP1[5]
ETMP1[4]
ETMP1[3]
ETMP1[2]
ETMP1[1]
ETMP1[0]
TMPR1
RD
ETMP2[3]
ETMP2[2]
ETMP2[1]
ETMP2[0]
ETMP1[11]
ETMP1[10]
ETMP1[9]
ETMP1[8]
TMPR2
RD
ETMP2[11]
ETMP2[10]
ETMP2[9]
ETMP2[8]
ETMP2[7]
ETMP2[6]
ETMP2[5]
ETMP2[4]
TMPR3
RD
ITMP[7]
ITMP[6]
ITMP[5]
ITMP[4]
ITMP[3]
ITMP[2]
ITMP[1]
ITMP[0]
TMPR4
RD
REV[2]
REV[1]
REV[0]
THSD
ITMP[11]
ITMP[10]
ITMP[9]
ITMP[8]
Table 11. Packet Error Code (PEC)
REGISTER
PEC
RD/WR
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
RD
PEC[7]
PEC[6]
PEC[5]
PEC[4]
PEC[3]
PEC[2]
PEC[1]
PEC[0]
68021fa
25
LTC6802-1
APPLICATIONS INFORMATION
Table 12. Memory Bit Descriptions
NAME
CDC
DESCRIPTION
Comparator Duty Cycle
VALUES
CDC
UV/OV COMPARATOR
PERIOD
VREF POWERED DOWN
BETWEEN MEASUREMENTS
CELL VOLTAGE
MEASUREMENT TIME
0
(default)
N/A (Comparator Off)
Standby Mode
Yes
N/A
1
N/A (Comparator Off)
No
13ms
2
13ms
No
13ms
3
130ms
No
13ms
4
500ms
No
13ms
5*
130ms
Yes
21ms
6
500ms
Yes
21ms
7
2000ms
Yes
21ms
*when MMB pin is low, the CDC value is set to 5
CELL10
10-Cell Mode
0=12-cell mode (default); 1=10-cell mode
LVLPL
Level Polling Mode
0=toggle polling (default); 1=level polling
GPIO1
GPIO1 Pin Control
GPIO2
GPIO2 Pin Control
WDT
Watchdog Timer
DCCx
Discharge Cell x
Write: 0=GPIO1 pin pull down on; 1=GPIO1 pin pull down off (default)
Read: 0=GPIO1 pin at logic ‘0’; 1=GPIO1 pin at logic ‘1’
Write: 0=GPIO2 pin pull down on; 1=GPIO2 pin pull down off (default)
Read: 0=GPIO2 pin at logic ‘0’; 1=GPIO2 pin at logic ‘1’
Read Only: 0=WDTB pin at logic ‘0’; 1=WDTB pin at logic ‘1’
x=1..12
0=turn off shorting switch for cell ‘x’ (default); 1=turn on shorting switch
Comparison voltage = VUV * 16 * 1.5mV
VUV
Undervoltage Comparison Voltage*
VOV
Overvoltage Comparison Voltage*
MCxI
Mask Cell x Interrupts
CxV
Cell x Voltage*
CxUV
Cell x Undervoltage Flag
CxOV
Cell x Overvoltage Flag
ETMPx
External Temperature Measurement*
THSD
Thermal Shutdown Status
REV
Revision Code
ITMP
Internal Temperature Measurement*
Temperature measurement voltage = ITMP * 1.5mV = 8mV * T(°K)
PEC
Packet Error Code
CRC value for reads
(default VUV=0. When MMB pin is low a factory programmed comparison voltage is used)
Comparison voltage = VOV * 16 * 1.5mV
(default VOV=0. When MMB pin is low a factory programmed comparison voltage is used)
x=1..12
0=enable interrupts for cell ‘x’ (default)
1=turn off interrupts and clear flags for cell ‘x’
x=1..12
12-bit ADC measurement value for cell ‘x’
cell voltage for cell ‘x’ = CxV * 1.5mV
reads as 0xFFF while A/D conversion in progress
x=1..12
cell voltage compared to VUV comparison voltage
0=cell ‘x’ not flagged for under voltage condition; 1=cell ‘x’ flagged
x=1..12
cell voltage compared to VOV comparison voltage
0=cell ‘x’ not flagged for over voltage condition; 1=cell ‘x’ flagged
Temperature measurement voltage = ETMPx * 1.5mV
0= thermal shutdown has not occurred; 1=thermal shutdown has occurred
Status cleared to ‘0’ on read of Thermal Register Group
Device revision code
*Voltage determinations use the decimal value of the registers, 0 to 4095 for 12-bit and 0 to 255 for 8-bit registers
68021fa
26
LTC6802-1
APPLICATIONS INFORMATION
SERIAL COMMAND EXAMPLES
LTC6802-1 (Daisy Chained Configuration)
Examples below use a configuration of three stacked
devices: bottom (B), middle (M), and top (T)
Write Configuration Registers
1.
2.
3.
4.
5.
6.
Pull CSBI low
Send WRCFG command byte
Send CFGR0 byte for top device, then CFGR1 (T), CFGR2 (T), … CFGR5 (T)
Send CFGR0 byte for middle device, then CFGR1 (M), CFGR2 (M), … CFGR5 (M)
Send CFGR0 byte for bottom device, then CFGR1 (B), CFGR2 (B), … CFGR5 (B)
Pull CSBI high; data latched into all devices on rising edge of CSBI
Calculation of serial interface time for sequence above:
Number of devices in stack= N
Number of bytes in sequence = B = 1 command byte and 6 data bytes per device = 1+6*N
Serial port frequency per bit = F
Time = (1/F) * B * 8 bits/byte = (1/F) * (1+6*N) * 8
Time for 3 cell-stacks example above, with 1MHz serial port = (1/1000000) * (1+6*3)*8 = 152us
Read Cell Voltage Registers (12 Cell Mode)
1.
2.
3.
4.
5.
6.
Pull CSBI low
Send RDCV command byte
Read CVR00 byte of bottom device, then CVR01 (B), CVR02 (B), … CVR17 (B), and then PEC (B)
Read CVR00 byte of middle device, then CVR01 (M), CVR02 (M), … CVR17 (M), and then PEC (M)
Read CVR00 byte for top device, then CVR01 (T), CVR02 (T), … CVR17 (T), and then PEC (T)
Pull CSBI high
Calculation of serial interface time for sequence above:
Number of devices in stack= N
Number of bytes in sequence = B = 1 command byte, and 18 data bytes plus 1 PEC byte per device = 1+19*N
Serial port frequency per bit = F
Time = (1/F) * B * 8 bits/byte = (1/F) * (1+19*N) * 8
Time for 3-cell example above, with 1MHz serial port = (1/1000000) * (1+19*3)*8 =464us
Start Cell Voltage A/D Conversions and Poll Status (Toggle Polling)
1.
2.
3.
4.
5.
Pull CSBI low
Send STCVAD command byte (all devices in stack start A/D conversions simultaneously)
SDO output from bottom device pulled low for approximately 12ms
SDO output toggles at 1kHz rate, indicating conversions complete for all devices in daisy chain
Pull CSBI high to exit polling
68021fa
27
LTC6802-1
APPLICATIONS INFORMATION
Poll Interrupt Status (Level Polling)
1.
2.
3.
4.
Pull CSBI low
Send PLINT command byte
SDO output from bottom device pulled low if any device has an interrupt condition; otherwise, SDO high
Pull CSBI high to exit polling
FAULT PROTECTION
Overview
Care should always be taken when using high energy
sources such as batteries. There are numerous ways that
systems can be [mis-]configured that might affect a battery system during its useful lifespan. Table 13 shows the
various situations that should be considered when planning protection circuitry. The first five scenarios are to be
anticipated during production and appropriate protection
is included within the LTC6802-1 device itself.
Table 13. LTC6802-1 Failure Mechanism Effect Analysis
SCENARIO
EFFECT
DESIGN MITIGATION
Cell input open-circuit (random)
Power-up sequence at IC inputs
Clamp diodes at each pin to V+ & V– (within IC) provide
alternate power-path.
Cell input open-circuit (random)
Differential input voltage overstress
Zener diodes across each cell voltage input pair (within IC)
limits stress.
Top cell input connection loss (V+) Power will come from highest connected cell input
or via data port fault current
Bottom cell input connection loss
(V–)
Clamp diodes at each pin to V+ & V– (within IC) provide
alternate power-path. Diode conduction at data ports will impair
communication with higher-potential units.
Power will come from lowest connected cell input or Clamp diodes at each pin to V+ & V– (within IC) provide
alternate power-path. Diode conduction at data ports will impair
via data port fault current
communication with higher-potential units.
Disconnection of a harness
Loss of supply connection to the IC
between a group of battery cells
and the IC (in a system of stacked
groups)
Clamp diodes at each pin to V+ & V– (within IC) provide an
alternate power-path if there are other devices (which can
supply power) connected to the LTC6802-1. Diode conduction
at data ports will impair communication with higher-potential
units.
Data link disconnection between
stacked LTC6802-1 units.
Break of "daisy chain" communication (no stress
to ICs). Communication will be lost to devices
above the disconnection. The devices below the
disconnection are still able to communicate and
perform all functions, however, the polling feature is
disabled.
All units above the disconnection will enter standby mode
within 2 seconds of disconnect. Discharge switches are
disabled in standby mode.
Cell-pack integrity, break between
stacked units
Daisy-chain voltage reversal up to full stack potential Use series protection diodes with top-port I/O connections
during pack discharge
(RS07J for up to 600V). Use isolated data link at bottom-most
data port.
Cell-pack integrity, break between
stacked units
Daisy-chain positive overstress during charging
Add redundant current path link
Cell-pack integrity, break within
stacked unit
Cell input reverse overstress during discharge
Add parallel Schottky diodes across each cell for load-path
redundancy. Diode and connections must handle full operating
current of stack, will limit stress on IC
Cell-pack integrity, break within
stacked unit
Cell input positive overstress during charge
Add SCR across each cell for charge-path redundancy. SCR
and connections must handle full charging current of stack, will
limit stress on IC by selection of trigger Zener
68021fa
28
LTC6802-1
APPLICATIONS INFORMATION
Battery Interconnection Integrity
The FMEA scenarios that are potentially most damaging are
those that involve a break in the stack of battery cells. When
the battery stack has a discontinuity between groupings
of cells monitored by LTC6802-1 ICs, any load will force
a large reverse potential on the daisy-chain connection.
This situation might occur in a modular battery system
during initial installation or a service procedure. The daisy
chain ports are protected from the reverse potential in this
scenario by external series high-voltage diodes required in
the upper-port data connections as shown in Figure 11.
During the charging phase of operation, this fault would
lead to forward biasing of daisy-chain ESD clamps that
would also lead to part damage. An alternative connection
to carry current during this scenario will avoid this stress
from being applied (Figure 11).
clamping potential. The Zener diodes labeled ZCLAMP are
higher voltage devices with an initial reverse breakdown
of 30V snapping back to 25V. The forward voltage drop
of all Zeners is 0.5V. Refer to this diagram in the event of
unpredictable voltage clamping or current flow. Limiting
the current flow at any pin to ±10mA will prevent damage
to the IC.
LTC6802-1
V+
SCKO
C12
S12
SDOI
C11
S11
ZCLAMP
C10
CSBO
S10
C9
V−
LTC6802-1
(NEXT HIGHER IN STACK)
C8
SDO
PROTECT
AGAINST
BREAK
HERE
OPTIONAL
REDUNDANT
CURRENT
PATH
S9
SDI
SCKI CSBI
S8
RS07J (3x)
SDOI SCKO CSBO
V+
C7
S7
ZCLAMP
C6
LTC6802-1
(NEXT LOWER IN STACK)
S6
68021 F11
C5
Figure 11. Reverse-Voltage Protection for the
Daisy-Chain (One Link Connection Shown)
S5
CSBI
C4
SDO
Internal Protection Diodes
S4
SDI
Each pin of the LTC6802-1 has protection diodes to help
prevent damage to the internal device structures caused
by external application of voltages beyond the supply rails
as shown in Figure 12.
C3
SCKI
The diodes shown are conventional silicon diodes with a
forward breakdown voltage of 0.5V. The unlabeled zener
diode structures have a reverse breakdown characteristic
which initially breaks down at 12V then snaps back to a 7V
VMODE
S3
ZCLAMP
C2
GPIO2
S2
GPIO1
C1
WDTB
S1
MMB
–
TOS
V
68021 F12
Figure 12. Internal Protection Diodes
68021fa
29
LTC6802-1
APPLICATIONS INFORMATION
Cell-Voltage Filtering
The LTC6802-1 employs a sampling system to perform
its analog-to-digital conversions and provides a conversion result that is essentially an average over the 0.5ms
conversion window, provided there isn’t noise aliasing with
respect to the delta-sigma modulator rate of 512kHz. This
indicates that a lowpass filter with useful attenuation at
500kHz may be beneficial. Since the delta-sigma integration bandwidth is about 1kHz, the filter corner need not
be lower than this to assure accurate conversions.
Series resistors of 100Ω may be inserted in the input
paths without introducing meaningful measurement
error, provided only external discharge switch FETs are
being used. Shunt capacitors may be added from the cell
inputs to V–, creating RC filtering as shown in Figure 13.
Note that this filtering is not compatible with use of the
internal discharge switches to carry current since this
would induce settling errors at the time of conversion as
any activated switches temporarily open to provide Kelvin
mode cell sensing. As a discharge switch opens, cell wiring
resistance will also form a small voltage step (recovery
of the small IR drop), so keeping the frequency cutoff of
the filter relatively high will allow adequate settling prior
to the actual conversion. A guard time of about 60μs is
provided in the ADC timing, so a 16kHz LP is optimal and
offers about 30dB of noise rejection.
No resistor should be placed in series with the V– pin.
Because the supply current flows from the V– pin, any
resistance on this pin could generate a significant conversion error for CELL1.
The V+ pin is powered from the top cell potential of the
monitored cell group. A decoupling network of 20Ω /100nF
is recommended.
READING EXTERNAL TEMPERATURE PROBES
Using Dedicated Inputs
The LTC6802-1 includes two channels of ADC input, VTEMP1
and VTEMP2, that are intended to monitor thermistors
(tempco about –4%/°C generally) or diodes (–2.2mV/°C
typical) located within the cell array. Sensors can be
powered directly from VREF as shown in Figure 14 (up to
60μA total).
For sensors that require higher drive currents, a buffer op
amp may be used as shown in Figure 15. Power for the
sensor is actually sourced indirectly from the VREG pin
LTC6802-1
100k
VREG
VREF
VTEMP2
VTEMP1
NC
V−
100k
100k
NTC
1μF
1μF
100k
NTC
68021 F14
Figure 14. Driving Thermistors Directly from VREF
+
LT6000
–
C(n)
100Ω
100nF
7.5V
S(n)
C(n – 1)
100Ω
100nF
LTC6802-1
VREG
VREF
VTEMP2
VTEMP1
NC
V−
10k
10k
10k
NTC
68021 F13
Figure 13. Adding RC Filtering to the Cell Inputs
(One Cell Connection Shown)
10k
NTC
68021 F15
Figure 15. Buffering VREF for Higher-Current Sensors
68021fa
30
LTC6802-1
APPLICATIONS INFORMATION
in this case. Probe loads up to about 1mA maximum are
supported in this configuration. Since VREF is shutdown
during the LTC6802-1 idle and shutdown modes, the
thermistor drive is also shut off and thus power dissipation minimized. Since VREG remains always on, the buffer
op amp (LT6000 shown) is selected for its ultralow power
consumption (10μA).
Expanding Probe Count
The LTC6802-1 provides general purpose I/O pins, GPIO1
and GPIO2, that may be used to control multiplexing of
several temperature probes. Using just one of the GPIO
pins, the sensor count can double to four as shown in
Figure 16. Using both GPIO pins, up to eight sensor inputs
can be supported.
Using Diodes to Monitor Temperatures in Multiple
Locations
Another method of multiple sensor support is possible
without the use of any GPIO pins. If the sensors are PN
diodes and several used in parallel, then the hottest diode
will produce the lowest forward voltage and effectively
establish the input signal to the VTEMP input(s). The hottest
LTC6802-1
diode will therefore dominate the readout from the VTEMP
inputs that the diodes are connected to. In this scenario,
the specific location or distribution of heat is not known,
but such information may not be important in practice.
Figure 17 shows the basic concept.
In any of the sensor configurations shown, a full-scale
cold readout would be an indication of a failed-open sensor connection to the LTC6802-1.
ADDING CALIBRATION AND
FULL-STACK MEASUREMENTS
By adding multiplexing hardware, additional signals can
be digitized by the CELL1 ADC channel. One useful signal
to provide is a high-accuracy voltage reference, such as
from an LT1461A-4. By periodic readings of this signal,
host software can provide correction of the LTC6802-1
readings to improve the accuracy over that of the internal
LTC6802-1 reference, and/or validate ADC operation. Another useful signal is a measure of the total stack potential.
This provides a redundant operational measurement of the
cells in the event of a malfunction in the normal acquisition process, or as a faster means of monitoring the entire
SN74LVC1G3157
OR SIMILAR DEVICE
GPIO1
200k
100k
VREG
VREF
VTEMP2
VTEMP1
NC
V−
LTC6802-1
100k
100k
NTC
100k
100k
NTC
VREG
VREF
200k
VTEMP2
VTEMP1
NC
V−
100k
NTC
1μF
100k
NTC
68021 F17
68021 F16
Figure 16. Expanding Sensor Count with Multiplexing
Figure 17. Using Diode Sensors as Hot-Spot Detectors
68021fa
31
LTC6802-1
APPLICATIONS INFORMATION
stack potential. Figure 18 shows a means of providing both
of these features. A resistor divider is used to provide a
low-voltage representation of the full stack potential (C12
to C0 voltage) with MOSFETs that decouple the divider
current under unneeded conditions. Other MOSFETs, in
conjunction with an op amp having a shutdown mode,
form a voltage selector that allows measurement of the
normal cell1 potential (when GPIO1 is low) or a buffered
MUX signal. When the MUX is active (GPIO1 is high),
selection can be made between the reference (4.096V) or
the full-stack voltage divider (GPOI2 set low will select the
reference). During idle time when the LTC6802-1 WTB signal
goes low, the external circuitry goes into a power down
condition, reducing battery drain to a minimum. When not
actively performing measurements, GPIO1 should be set
low and GPIO2 should be set high to achieve the lowest
power state for the configuration shown.
TP0610K
CELL12
1M
2.2M
GPIO2
GPIO1
0 = REF_EN
VSTACK12
0 = CELL1
WDTB
1M
1M
LT1461A-4
10M
1M
VREG
2N7002
LTC6802-1
1μF
90.9k
2N7002
DNC DNC
DNC
VIN
SD VOUT
GND DNC
V−
4.096V
2.2μF
C1
150Ω
100Ω
100nF
VDD CH0 CH1 SEL
SD LT1636
TC4W53FU
–
CELL1
+
TP0610K
TP0610K TP0610K
COM INH VEE VSS
1M
68021 F18
Figure 18. Providing Measurement of Calibration Reference and Full-Stack Voltage Through CELL1 Port
68021fa
32
LTC6802-1
APPLICATIONS INFORMATION
PROVIDING HIGH-SPEED OPTO-ISOLATION
OF THE SPI DATA-PORT
Isolation techniques that are capable of supporting the
1Mbps data rate of the LTC6802-1 require more power
on the isolated (battery) side than can be furnished by
the VREG output of the LTC6802-1. To keep battery drain
minimal, this means that a DC/DC function must be implemented along with a suitable data isolation circuit, such as
shown in Figure 19. Here an optimal Avago 4-channel (3/1
bidirectional) opto-coupler is used, with a simple isolated
supply generated by an LTC1693-2 configured as a 200kHz
oscillator. The DC/DC function provides an unregulated
logic voltage (~4V) to the opto-coupler isolated side,
from energy provided by host-furnished 5V. This circuit
provides totally galvanic isolation between the batteries
and the host processor, with an insulation rating of 560V
continuous, 2500V transient.
330Ω
3.57k
3.57k
+5V_HOST
100k
CSBI
3.57k
100k
SDI
CSBI
TP0610K
SDO
100k
330Ω
SDI
SCKI
TP0610K
330Ω
SCKI
TP0610K
VREG
SDO
100nF
4.99k
249Ω
LTC6802-1
GND_HOST
ACSL-6410
ISOLATED VLOGIC
BAT54S
1μF
1μF
BAT54S
6•
4
V−
VCC1
•1
3
PE68386
470pF
20k
IN1
OUT1 GND1
33nF
VCC2
IN2
10k
OUT2 GND2
LTC1693-2
68021 F19
Figure 19. Providing an Isolated High-Speed Data Interface
68021fa
33
LTC6802-1
APPLICATIONS INFORMATION
PCB LAYOUT CONSIDERATIONS
ADVANTAGES OF DELTA-SIGMA ADCS
The VREG and VREF pins should be bypassed with a 1μF
capacitor for best performance.
The LTC6802-1 employs a delta sigma analog to digital
converter for voltage measurement. The architecture of
delta sigma converters can vary considerably, but the
common characteristic is that the input is sampled many
times over the course of a conversion and then filtered or
averaged to produce the digital output code. In contrast,
a SAR converter takes a single snapshot of the input
voltage and then performs the conversion on this single
sample. For measurements in a noisy environment, a
delta sigma converter provides distinct advantages over
a SAR converter.
The LTC6802-1 is capable of operation with as much as
60V between V+ and V–. Care should be taken on the PCB
layout to maintain physical separation of traces at different
potentials. The pinout of the LTC6802-1 was chosen to
facilitate this physical separation. Figure 20 shows the DC
voltage on each pin with respect to V– when twelve 3.6V
battery cells are connected to the LTC6802-1. There is no
more then 5.5V between any two adjacent pins. The package body is used to separate the highest voltage (43.5V)
from the lowest voltage (0V).
LTC6802-1
42.5V
42.5V
42.5V
43.2V
43.2V
43.2V
39.6V
39.6V
36V
36V
32.4V
32.4V
28.8V
28.8V
25.2V
25.2V
21.6V
21.6V
18V
18V
14.4V
14.4V
CSBO
SDOI
SCKO
V+
C12
S12
C11
S11
C10
S10
C9
S9
C8
S8
C7
S7
C6
S6
C5
S5
C4
S4
CSBI
SDO
SDI
SCKI
VMODE
GPIO2
GPIO1
WDTB
MMB
TOS
VREG
VREF
VTEMP2
VTEMP1
NC
V−
S1
C1
S2
C2
S3
C3
0V TO 5.5V
0V TO 5.5V
0V TO 5.5V
0V TO 5.5V
0V TO 5.5V
0V TO 5.5V
0V TO 5.5V
0V TO 5.5V
0V TO 5.5V
0V TO 5.5V
5.5V
3.1V
1.5V
1.5V
0V
0V
3.6V
3.6V
7.2V
7.2V
10.8V
10.8V
68021 F20
Figure 20. Typical Pin Voltages for 12 3.6V Cells
While SAR converters can have high sample rates, the fullpower bandwidth of a SAR converter is often greater than
1MHz, which means the converter is sensitive to noise out
to this frequency. And many SAR converters have much
higher bandwidths – up to 50MHz and beyond. It is possible to filter the input, but if the converter is multiplexed
to measure several input channels a separate filter will be
required for each channel. A low frequency filter cannot
reside between a multiplexer and an ADC and achieve a
high scan rate across multiple channels. Another consequence of filtering a SAR ADC is that any noise reduction
gained by filtering the input cancels the benefit of having
a high sample rate in the first place, since the filter will
take many conversion cycles to settle.
For a given sample rate, a delta sigma converter can
achieve excellent noise rejection while settling completely
in a single conversion – something that a filtered SAR converter cannot do. Noise rejection is particularly important
in high voltage switching controllers, where switching
noise will invariably be present in the measured voltage.
Other advantages of delta sigma converters are that they
are inherently monotonic, meaning they have no missing
codes, and they have excellent DC specifications.
68021fa
34
LTC6802-1
APPLICATIONS INFORMATION
Converter Details
Each conversion consists of two phases – an autozero
phase and a measurement phase. The ADC is autozeroed
at each conversion, greatly improving CMRR. The second
half of the conversion is the actual measurement.
Noise Rejection
Figure 21 shows the frequency response of the ADC.
The rolloff follows a Sinc2 response, with the first notch
at 4kHz. Also shown is the response of a 1 pole, 850Hz
filter (187μs time constant) which has the same integrated
response to wideband noise as the LTC6802-1’s ADC,
which is about 1350Hz. This means that if wideband noise
is applied to the LTC6802-1 input, the increase in noise
seen at the digital output will be the same as an ADC with
a wide bandwidth (such as a SAR) preceded by a perfect
1350Hz brickwall lowpass filter.
Thus if an analog filter is placed in front of a SAR converter
to achieve the same noise rejection as the LTC6802-1 ADC,
0
FILTER GAIN (dB)
The LTC6802-1’s ADC has a second order delta sigma
modulator followed by a Sinc2, finite impulse response
(FIR) digital filter. The front-end sample rate is 512ksps,
which greatly reduces input filtering requirements. A
simple 16kHz, 1 pole filter composed of a 100Ω resistor
and a 0.1μF capacitor at each input will provide adequate
filtering for most applications. These component values
will not degrade the DC accuracy of the ADC.
10
–10
–20
–30
–40
–50
–60
10
100
1k
10k
FREQUENCY (Hz)
100k
68021 F20
Figure 21. Noise Filtering of the LTC6802-1 ADC
the SAR will have a slower response to input signals. For
example, a step input applied to the input of the 850Hz filter
will take 1.55ms to settle to 12 bits of precision, while the
LTC6802-1 ADC settles in a single 1ms conversion cycle.
This also means that very high sample rates do not provide
any additional information because the analog filter limits
the frequency response.
While higher order active filters may provide some improvement, their complexity makes them impractical for
high-channel count measurements as a single filter would
be required for each input.
Also note that the Sinc2 response has a 2nd order rolloff
envelope, providing an additional benefit over a single
pole analog filter.
68021fa
35
LTC6802-1
PACKAGE DESCRIPTION
G Package
44-Lead Plastic SSOP (5.3mm)
(Reference LTC DWG # 05-08-1754 Rev Ø)
12.50 – 13.10*
(.492 – .516)
1.25 p0.12
7.8 – 8.2
44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23
5.3 – 5.7
0.25 p0.05
RECOMMENDED SOLDER PAD LAYOUT
APPLY SOLDER MASK TO AREAS THAT ARE NOT SOLDERED
5.00 – 5.60*
(.197 – .221)
PARTING
LINE
0.10 – 0.25
(.004 – .010)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
2.0
(.079)
MAX
1.65 – 1.85
(.065 – .073)
0o – 8o
0.55 – 0.95**
(.022 – .037)
1.25
(.0492)
REF
NOTE:
1.DRAWING IS NOT A JEDEC OUTLINE
2. CONTROLLING DIMENSION: MILLIMETERS
3. DIMENSIONS ARE IN
0.50
BSC
7.40 – 8.20
(.291 – .323)
MILLIMETERS
(INCHES)
4. DRAWING NOT TO SCALE
5. FORMED LEADS SHALL BE PLANAR WITH RESPECT TO
ONE ANOTHER WITHIN 0.08mm AT SEATING PLANE
0.50
(.01968)
BSC
SEATING
PLANE
0.20 – 0.30†
(.008 – .012)
TYP
0.05
(.002)
MIN
G44 SSOP 0607 REV Ø
*DIMENSIONS DO NOT INCLUDE MOLD FLASH OR PROTRUSIONS,
BUT DO INCLUDE MOLD MISMATCH AND ARE MEASURED AT
THE PARTING LINE. MOLD FLASH SHALL NOT EXCEED .15mm PER SIDE
**LENGTH OF LEAD FOR SOLDERRING TO A SUBSTRATE
†THE MAXIMUM DIMENSION DOES NOT INCLUDE DAMBAR PROTRUSIONS.
DAMBAR PROTRUSIONS DO NOT EXCEED 0.13mm PER SIDE
68021fa
36
LTC6802-1
REVISION HISTORY
REV
DATE
DESCRIPTION
PAGE NUMBER
A
01/10
Text Changes to Description
Additions to Absolute Maximum Ratings
Changes to Electrical Characteristics
Changes to Graph G02
Text Changes to Pin Functions
Open Connection Detection Section Replaced
Text Changes to Operation Section
Figures 1, 6 Title Changes
Text Changes to Applications Information Section
Edits to Tables 6, 7, 12, 13
1
2
3, 4
5
8
11, 13
11, 13, 14
12, 18
16, 28, 29, 30, 31
23, 24, 26, 28
Edit to Figure 12
29
Edit to Typical Application
38
68021fa
Information furnished by Linear Technology Corporation is believed to be accurate and reliable.
However, no responsibility is assumed for its use. Linear Technology Corporation makes no representation that the interconnection of its circuits as described herein will not infringe on existing patent rights.
37
LTC6802-1
TYPICAL APPLICATION
Cascadable 12-Cell Li-Ion Battery Monitor
CASCADED SPI PORT
TO NEXT LTC6802-1
CSBO
SDIO
SCKO
PRTR5V0U4D
RS07J RS07J RS07J
CELL12
BLM31PG330SN1L
100Ω
CMHZ5265B
BAT46W
BAT46W
BAT46W
BAT46W
BAT46W
2
5
3
4
LTC6802-1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
BAT46W
C12FILTER
DC12
C11FILTER
DC11
C10FILTER
DC10
C9FILTER
DC9
REPEAT INPUT
CIRCUITS FOR
CELL3 TO CELL12
100Ω
6
1M
20Ω
100nF
20Ω
1
C8FILTER
DC8
C7FILTER
DC7
C6FILTER
DC6
C5FILTER
DC5
C4FILTER
DC4
1M
100Ω
44
CSBI
43
SDO
42
SDI
41
SCKI
40
VMODE
39
GPIO2
38
GPIO1
37
WDTB
36
MMB
35
TOS
34
VREG
33
VREF
32
VTEMP2
31
VTEMP1
30
NC
− 29
V
28
S1
27
C1
26
S2
25
C2
24
S3
23
C3
CSBO
SDOI
SCKO
V+
C12
S12
C11
S11
C10
S10
C9
S9
C8
S8
C7
S7
C6
S6
C5
S5
C4
S4
1M
CSBI
SDO*
SDI
SCKI
100Ω
20Ω
100Ω
1M
MAIN SPI PORT
TO HOST μP OR
NEXT LTC6802-1
*REQUIRES 1k PULL-UP RESISTOR AT HOST DEVICE
(SIGNAL NOT USED FOR CURRENT-MODE COMMUNICATION)
1M
1M
10k
NTC2
1μF
3
1μF
8
+
1/2 LT6004
2
100Ω
1
10nF
–
4
C3FILTER
DC3
100Ω
CELL2
100nF
SI2351DS
DC2
33Ω
CELL1
3.3k
100Ω
8
+
1/2 LT6004
6
PDZ7.5B
MM3Z12VT1
475Ω
5
C2FILTER
7
10k
NTC1
–
100Ω
4
C1FILTER
10nF
100nF
SI2351DS
PDZ7.5B
MM3Z12VT1
DC1
33Ω
475Ω
3.3k
68021 TA02
RELATED PARTS
PART NUMBER
DESCRIPTION
COMMENTS
LTC6802-2
Multicell Battery Stack Monitor with an Individually
Addressable Serial Interface
Functionality equivalent to LTC6802-1, Allows for Parallel Communication
Battery Stack Topologies
68021fa
38 Linear Technology Corporation
LT 0110 REV A • PRINTED IN USA
1630 McCarthy Blvd., Milpitas, CA 95035-7417
(408) 432-1900 ● FAX: (408) 434-0507
●
www.linear.com
© LINEAR TECHNOLOGY CORPORATION 2009