ARTESYN LX350-7624

LX350 SERIES
Flexible single and multiple outputs
•
•
•
•
•
•
•
The LX350 series offers 350 Watts of continuous output power in a low profile
industry standard footprint. With two standard single output options and a
flexible standard multiple output version, the series can address most
requirements as standard. The design is specifically tailored to allow full
flexibility and modifications to meet customer applications can be implemented
with relative ease. The LX350 AC input series meets the safety requirements of
EN60950, VDE0805, UL1950 and CSA 22.2 No. 950. Input conducted noise
levels meet the requirements of EN55022 class B. LX350 series power supplies
are ideal for use in applications such as point-of-sale equipment, central and
public telecom power systems and network equipment.
[ 2 YEAR WARRANTY ]
SPECIFICATION
350W continuous, 550W peak output power
Industry standard footprint, low profile
Conducted noise to meet EN55022 class B
AC and DC input voltage options in same package
Efficiency up to 88%
Optional power sharing/VME signals
Autoranging input
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
Voltage adjustability
ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS
Vout on singles
+5V output on multiple
-8%/+16%
±20%
Remote sense
±10%
Line regulation
(LL to HL, FL)
Single outputs
Multiple: +5V output
Multiple: aux. outputs, Note 4
±0.2%
±0.2%
±0.5%
Load regulation
(20% to 100% FL)
Singles
Multiple: +5V output
Multiple: ±12, +24V outputs
Multiple: -5V output, Note 4
±0.2%
±1.0%
±2.0%
±4.0%
5A load step on main output
Auxiliary outputs, Note 4
1.0%
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, level B
EN55022
EN61000-4-2, level
EN61000-4-2, level
EN61000-4-5, level
EN61000-4-4, level
EN61000-4-3, level
EN61000-4-6, level
3
4
3
3
3
3
Transient response
25% di/dt
1% max. dev.
1ms recovery
Temperature coefficient Main/single output
Multiple: auxiliary outputs
±0.02%/°C
±0.04%/°C
Overvoltage protection
Main/single output
Output power limit
Multiples:
600W Pout
primary power limited
Singles:
105%-120% Iout
current foldback
Short circuit protection
All outputs
130% ±10% Vout
Hold-up time
110/230VAC
Autorange fitted
as standard
Drop-out voltage
Input/output
Input/chassis
Switching frequency
Fixed
Approvals and
standards, See Note 7
Input surge current
25A, max.
Input frequency
Safety ground
leakage current
Remote OFF
PAGE 1
50Hz/60Hz
110VAC, 60Hz
230VAC, 50Hz
1.6mA
2.5mA
Logic 0 on ROF
28ms
3000VAC
1500VAC
44kHz
EN60950, VDE0805, UL1950
CSA C22.2 No. 950
Weight
2.5kg (88oz)
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating
0°C to +70°C
Non-operating
–25°C to +85°C
0°C to 40°C ambient,
350W
convection cooled
40°C to 70°C ambient, Derate linearly
convection cooled
to 25% full load
Peak (0°C to 40°C, max. 10s)
550W
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
Vibration
Operating, 5-50Hz
Operating, 50-100Hz
Non-operating
Yes
98 to 132VAC
190 to 264VAC
90VAC
1
1
1
1
2
1
82% min.
Isolation voltage
INPUT SPECIFICATIONS
Input voltage range
See Note 5
criteria
criteria
criteria
criteria
criteria
criteria
GENERAL SPECIFICATIONS
Efficiency
Cross regulation
Perf.
Perf.
Perf.
Perf.
Perf.
Perf.
5% to 95% RH
10,000 feet max.
30,000 feet max.
0.05mm, pk-pk
0.025mm pk-pk
100mm drop on
chassis face
AC/DC POWER SUPPLIES
|
350W AC
350 Watt
AC/DC universal input switch mode power supplies
OUTPUT CURRENTS
OUTPUT
VOLTAGE
MAX
(1)
PEAK
OUTPUT RIPPLE
(2)
RMS
PK-PK
+5.0V
50.0A
100.0A
0.2%
2.0%
–5.0V
4.0A
10.0A
0.2%
2.0%
–12.0V
4.0A
10.0A
0.2%
2.0%
+12.0V
8.0A
20.0A
0.2%
2.0%
+24.0V
4.0A
10.0A
0.2%
2.0%
LX350-7620
24.0V
(3)
16.0A
–
0.1%
1.0%
LX350-7624
48.0V
(3)
8.0A
–
0.1%
1.0%
LX350-7617
Notes
INPUT CONNECTIONS
Pin 1
Earth
Pin 2
Neutral
Pin 3
Live
1
2
3
4
OUTPUT CONNECTIONS
5
The multiple output LX350 has a continuous output power rating of 350W.
The single-output versions have a continuous output power rating of
385W.
Peak power figures for individual outputs on the multiple output unit are
for less than 10 seconds duration. The overall peak power for the unit is
550W for 10 seconds duration.
Single output models are adjustable -8%, +16%.
A 10% load on the main output is necessary to maintain regulation on the
auxiliaries at full load (multi output model).
The input board is fitted with an autorange circuit as standard which
automatically senses the input voltage and switches to the appropriate
voltage range.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Consideration should be given to measuring the temperature on the main
transformer (T1) when the power supply is installed in end-use equipment.
The measured temperature on T1 must not exceed 90°C. For further
information on the LX350 safety approvals, contact Computer Products.
MULTI O/P
SINGLE O/P
SIGNALS
1
+5VS
0VS
SRS
6
2
+5V
0V
ACF
7
3
+5V
0V
DCF
4
+5V
0V
PM
5
0V
0V
PS
6
0V
0V
ROF
7
0V
+V
+VS
8
–5V
+V
0V
9
–12V
+V
–
10
+12V
+V
–
OPTIONS
11
+24V
+VS
–
None
Cover
Signals
Cover and Signals
12
MODEL NUMBER
ROF
ROF
–
Options
•
•
DC input models for 24V and 48V operation are detailed on the LX200,
LX350 and LX550 series DC/DC converter data sheet on page 170.
A safety cover and signals board are available as options. To order, add
the suffixes ‘-C’, ‘-S’ respectively , see table below.
SUFFIX
-C
-S
-C-S
EXAMPLE
LX350-76xx
LX350-76xx-C
LX350-76xx-S
LX350-76xx-C-S
OVERLOAD/SHORT CIRCUIT PROTECTION
The overload/short circuit protection mechanisms are different for the single
output models and the multiple output model.
The single output models will current limit when the output load reaches
105-120% of maximum load during overload or short circuit conditions.
The unit will operate in a constant current mode making the single output
models suitable for battery charging applications.
The multiple output model uses a power limiting function. When the total
output power reaches 600W the outputs will foldback to the values detailed
below:
Foldback Value
Output
+5V
30A continuous
+12V
8A continuous
+24V
4A continuous
–5V/–12V
Protected by 4A Multi Fuse™
The outputs will not foldback until the total output power exceeds the maximum power limits. This allows the units to have a peak power capability
but it requires that care must be taken not to permanently overload any
individual output. The +5V, +12V and +24V outputs are not individually protected and it is recommended that the maximum continuous load does not
exceed the value given in the output specifications. The -5V and -12V outputs are individually protected by a 4A Multi Fuse™ and the maximum continuous load should not exceed the value given in the output specifications.
http://www.artesyn.com
SIGNALS (OPTIONAL)
An optional signals board supplies the following VME utility bus signals:
ACF (AC Fail) Logic 1 to 0 transition occurs >10ms before outputs fall
below 80%-85% of nominal in the event of input failure.
DCF (DC Fail) Logic 0 occurs if output falls below <85%–95% of nominal.
SRS (System Reset) Logic 1 for system OK (AC and DC good and reset
times [200ms])
PM Power Monitor signal, proportional to the output power, ratio of
10mV/W, ±10%.
PS Power Share connections, to be joined for parallel operation of two
or more units, ensuring equal power share. For power share
operation unit outputs need to be set to ±5% of each other and
should be connected in star configurations with the load as star
centre.
PAGE 2
AC/DC POWER SUPPLIES
|
350W AC
350 Watt
AC/DC universal input switch mode power supplies
Mechanical notes
A Input and output connectors are 3 way and 11 way 9.5mm barrier strip
with M4 X 8 fixings, 250V 20A. Signals board connector is 8 way, single
row right angle 0.1”, Molex 910210128, this mates with 90147 1108 or
equivalent.
B Customer fixing screws (A) are M3 isometric. They must not penetrate into
unit by more than 5mm.
INPUT
1 2
OUTPUT
SIGNALS
SYSTEM
O. K. LED
3
1
4 5
8
1 2
3 4 5 6
7 8 9 10 11
12
11.81 (300.00)
A
A
A
1.18
(30)
5.12
(130)
7.48 (190.00)
A
9.44 (240.00)
A
0.89
A
0.79
10.39 (264.00)
A
(22.50) (20.00)
2.48 (63.00.00)
1.18
(30.00)
0.71
(18.00)
A
ALL DIMENSIONS IN INCHES (mm)
DERATING CURVE
Output Power (Watts)
550W
PEAK OUTPUT
POWER
International Safety Standard Approvals:
350W
Multiple output and 24V Single output units are approved to these standards.
Safety approval pending for 48V output model. See Note 7
EN60950/VDE0805 Reg. File No. 90370
NATURAL
CONVECTION
COOLING
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C/LR101320
87.5W
0W
0°C 10°C
PAGE 3
20°C
30°C
40°C
50°C
60°C
70°C
http://www.artesyn.com
PAGE 4
DS_LX350AC_19980401.PDF
Data Sheet © Artesyn Technologies® 2000
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising