MAP110 SERIES Power-One’s MAP110 series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure world-wide acceptance. All units bear the CE Mark. Wide dynamic output current and fixed frequency operation simplifies system level operation. The MAP110 series is configured to an international standard footprint. Input and output connections are made via popular single-row Molex connectors. Single output models feature wide-range output adjustability to meet a wide variety of standard and user specific output voltage requirements. FEATURES • New 3.3V and 5V Output Models • Universal Input 85-264 VAC • Industry Standard Footprint: 7.00" x 4.30" x 1.97" (177.8mm x 109.2mm x 50.0mm) • Input Transient & ESD Compliance to EN61000-4-2/-3/-4 • Greater than 134,000 Hours MTBF • Remote Sense and Over-Voltage Protection on Single Output Units and Main Output of Multiple Output Units • Options Include Over-Temperature Protection, Power Fail Signal, Chassis & Cover SINGLE OUTPUT MODEL SELECTION CHART MODEL OUTPUT VOLTAGE MAP110-1005 5V MAP110-1012 12V/15V MAP110-1024 24V/28V ADJUSTMENT RANGE CONVECTION COOLED OUTPUT CURRENT FORCED AIR OUTPUT CURRENT LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 1) INITIAL SETTING ACCURACY 4.95V to 5.50V 11.25V to 15.75V 22.8V to 29.2V 16A 7.5/6A (Note 2) 3.8/3.2A (Note 2) 22A 10/8A (Note 2) 5.0/4.3A (Note 2) 0.2% 0.1% 0.1% 1% 0.5% 0.5% 1% 1% 1% 5.09V to 5.11V 11.97V to 12.02V 23.95V to 24.05V NOTES: 1) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 2) MAP110-1012 output currents are expressed as 12V/15V operation. MAP110-1024 output currents are expressed as 24V/28V operation. MULTIPLE OUTPUT MODEL SELECTION CHART – 80W CONVECTION COOLED, 110W FORCED AIR COOLED (200 LFM) MODEL MAP110-4000 MAP110-4001 MAP110-4002 MAP110-4003 MAP110-4004 Rev. 03/2001 OUTPUT VOLTAGE ADJUSTMENT RANGE CONVECTION COOLED CURRENT (NOTE 1) FORCED AIR CURRENT LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 2) INITIAL SETTING ACCURACY +5V +12V -12V -5V +5V +24V -12V +12V +5V +12V -12V +12V +5V +15V -15V -5V +5V +24V -15V +15V 4.75V to 5.25V Fixed Fixed Fixed 4.75V to 5.25V Fixed Fixed Fixed 4.75V to 5.25V Fixed Fixed Fixed 4.75V to 5.25V Fixed Fixed Fixed 4.75V to 5.25V Fixed Fixed Fixed 12A/20A PK 5A/9A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 3A/4.5A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 5A/9A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 5A/7.3A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 3A/4.5A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 5A/9A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 3A/4.5A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 5A/9A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 5A/7.3A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 3A/4.5A PK 1A/1.5A PK 1A/1.5A PK 0.2% 0.2% 0.2% 0.2% 0.2% 0.1% 0.1% 0.1% 0.2% 0.1% 0.1% 0.1% 0.2% 0.1% 0.1% 0.2% 0.2% 0.1% 0.1% 0.1% 0.5% 1% 1% 1.5% 0.5% 1% 1% 1% 0.5% 1% 1% 1% 0.5% 1% 1% 1.5% 0.5% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 5.09V to 5.11V 11.97V to 12.03V -11.4V to -12.6V -4.75V to -5.25V 5.09V to 5.11V 23.94V to 24.06V -11.4V to -12.6V 11.4V to 12.6V 5.09V to 5.11V 11.97V to 12.03V -11.4V to -12.6V 11.4V to 12.6V 5.09V to 5.11V 14.96V to 15.04V -14.3V to -15.7V -4.75V to -5.25V 5.09V to 5.11V 23.94V to 24.06V -14.3V to -15.7V 14.3V to 15.7V 1 MAP110 SERIES MULTIPLE OUTPUT MODEL SELECTION CHART (CONT.) – 80W CONVECTION COOLED, 110W FORCED AIR COOLED (200 LFM) MODEL MAP110-4010 MAP110-4011 MAP110-4015 MAP110-4200 New MAP110-4300 (Note 3) New MAP110-4305 (Note 3) NOTES: OUTPUT VOLTAGE ADJUSTMENT RANGE CONVECTION COOLED CURRENT (NOTE 1) FORCED AIR CURRENT LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 2) INITIAL SETTING ACCURACY +5V +12V -5V -12V +5V +12V -12V +24V +5V +12V -15V +15V +12V +24V -12V +5V +3.3V +5V -12V +12V +3.3V +5V -5V +12V 4.75V to 5.25V Fixed Fixed Fixed 4.75V to 5.25V Fixed Fixed Fixed 4.75V to 5.25V Fixed Fixed Fixed 11.55V to 12.45V Fixed Fixed Fixed 3.2V to 3.4V Fixed Fixed Fixed 3.2V to 3.4V Fixed Fixed Fixed 12A/20A PK 5A/9A PK 1A/1.5A PK 3A/4A PK 12A/20A PK 5A/9A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 5A/9A PK 1A/1.5A PK 1A/1.5A PK 5A/9A PK 4A/4.5A PK 1A/1.5A PK 2A/2.5A PK 12A/20A PK 5A/12A PK 1A/1.5A PK 1A/1.5A PK 12A/15A PK 5A/12A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 5A/9A PK 1A/1.5A PK 3A/4A PK 12A/20A PK 5A/9A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 5A/9A PK 1A/1.5A PK 1A/1.5A PK 5A/9A PK 4A/4.5A PK 1A/1.5A PK 2A/2.5A PK 15A/20A PK 8A/12A PK 1A/1.5A PK 1A/1.5A PK 15A/20A PK 8A/12A PK 1A/1.5A PK 1A/1.5A PK 0.2% 0.1% 0.2% 0.3% 0.2% 0.1% 0.1% 0.1% 0.2% 0.1% 0.1% 0.1% 0.2% 0.2% 0.2% 0.2% 0.3% 0.2% 0.1% 0.1% 0.3% 0.2% 0.1% 0.1% 0.5% 2% 1.5% 8% 0.5% 1% 1% 1% 0.5% 1% 1% 1% 0.5% 1% 1% 1.5% 0.7% 1% 1% 1% 0.7% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 0.5% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 5.09V to 5.11V 11.97V to 12.03V -4.75V to -5.25V -11.5V to -12.5V 5.09V to 5.11V 11.97V to 12.03V -11.4V to -12.6V 23.2V to 24.8V 5.09V to 5.11V 11.97V to 12.03V -14.4V to -15.6V 14.4V to 15.6V 11.96V to 12.03V 23.94V to 24.06V -11.4V to -12.6V 4.75V to 5.25V 3.29V to 3.31V 4.98V to 5.02V -11.4V to -12.6V 11.4V to 12.6V 3.29V to 3.31V 4.98V to 5.02V -4.75V to -5.25V 11.4V to 12.6V 1) Peak loads up to 110 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 110 Watts. 2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3) Sum of the output currents of V1 + V2 may not exceed 15A continuous, 22A peak. MAXIMUM OUTPUT RATING: MODEL/OUTPUT OPTION CONVECTION CONTINUOUS/PEAK FORCED AIR 200 LFM MULTIPLE OUTPUT BOARD ONLY SINGLE OUTPUT BOARD ONLY MULTIPLE OUTPUT ‘L’-BRACKET SINGLE OUTPUT ‘L’-BRACKET MULTIPLE OUTPUT ‘C’-COVER SINGLE OUTPUT C’-COVER 80W/110W 90W/120W 80W/110W 90W/120W 60W/110W 65W/120W 110W 120W 110W 120W 110W 120W INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN Input Voltage - AC Input Frequency Brown Out Protection Hold-up Time 85 47 85 40 20 Input Protection Inrush Surge Current Continuous input range. AC input. Lowest AC input voltage that regulation is maintained with full rated loads. Nominal AC input voltage (110 VAC) 50% load: Full rated load: 85 VAC (110W load). 110VAC (110W load). Non-user serviceable internally located AC input line fuse. Internally limited by thermistor. Vin = 264 VAC (one cycle). 25°C. Operating Frequency Switching frequency of main transformer, (fixed frequency). 20 Input Current 2 NOM MAX UNITS 264 63 VAC Hz VAC mS 3.5 2.8 ARMS 41 APK 25 kHz MAP110 SERIES OUTPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX Efficiency Minimum Loads Full load, 230 VAC. Varies with distribution of loads among outputs. Single output models. Multiple output models, V1 + V2 (Note 1). Full Load, 20 MHz Bandwidth. Multiple output units with convection cooling. Multiple output units with 200 LFM forced air cooling. Output voltage overshoot/undershoot at turn-on. Varies by output, regulation includes: line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output only on multiple output units). Time required for initial output voltage stabilization. Time required for output voltage to rise from 10% to 90%. 65 0 1 75 80 Ripple and Noise Output Power Overshoot / Undershoot Regulation Transient Response Turn-on Delay Turn-on Rise Time 5 5 UNITS % Amps Amps See Model Selection Chart. 80 Watts 110 Watts 0 V See Model Selection Chart. 500 1 20 µS Sec mS NOM MAX UNITS 150 7.20 20.2 37.8 16.2 4.35 6.75 200 % 250 mV INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION Overvoltage Protection Provided on single output models and the main output of multiple output models. Overload Protection Remote Sense Input Power Fail Warning Overtemperature Protection MIN MAP110-1005 MAP110-1012 MAP110-1024 MAP110-4200 MAP110-4300 All other models. Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Voltage drop compensated for at the load. Option, TTL compatible logic signal. Time before regulation dropout due to loss of input power at 110 VAC. Active low. Option, system shutdown due to excessive internal temperature. 6.10 17.3 32.2 13.8 3.7 5.75 3 5 MIN NOM V mS SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION Agency Approvals UL1950. CSA 22.2 No. 234/950. EN60950 (TUV). Input to Output. FCC CFR title 47 part 15 sub-part B - conducted & radiated. EN55022 / CISPR 22 conducted. EN55022 / CISPR 22 radiated (Note 2). EN61000-4-5 level 3. Input to output. Per EN60950, 264 VAC. Dielectric Withstand Voltage Electromagnetic Interference, Conducted Input Transient Protection Insulation Resistance Leakage Current UNITS Approved. 2600 VDC B B A Class 2 10 NOTES: 1) Minimum load is required only to meet the regulation limits of V3 and V4. If V3 and V4 are unused, no minimum load is necessary. 2) The following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300. 3 MAX 750 kV M⍀ µA MAP110 SERIES ENVIRONMENTAL SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION Altitude Operating. Non-operating. Derate linearly above 50°C by 2.5% per° C to a maximum temperature of 70°C. Operating Temperature Storage Temperature Temperature Coefficient Relative Humidity MIN At 100% load: At 50% load: 0°C to 70°C. Non-condensing. NOM 0 0 -55 ±0.03 MAX UNITS 10k 50k 50 70 85 ±0.05 95 ASL Ft. ASL Ft. °C °C °C %/°C %RH OPTIONS DESCRIPTION NOTES L-Bracket Add ‘L’ suffix to model number. DIMENSIONS Cover Add ‘C’ suffix to model number. Includes L-Bracket. Power Fail Signal Thermal Shutdown Add ‘P’ suffix to model number. Provides >5 mS typical warning time before main output drops 5%. Warning time increases at reduced load levels. Add ‘T’ suffix to model number. Initiates shut-down in the event of an overtemperature condition. Automatic recovery. 7.15" x 4.50" x 2.40" (182.0mm x 115.0mm x 61.0mm) 7.20" x 4.50" x 2.40" (183.0mm x 115.0mm x 61.0mm) N/A N/A NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. 4 MAP110 SERIES OVERALL SIZE: 7.00" X 4.30" X 1.97" (177.8mm x 109.2mm x 50.0mm) OVERALL WEIGHT: 1.3 LBS (0.59 kg) NOTE 1 Contact factory for dimensions for L-bracket and cover. 5