POWER-ONE MAP110-4003

MAP110 SERIES
Power-One’s MAP110 series of power supplies combines low cost
and universal input in a board-only power solution to meet
commercial and industrial requirements. Full international safety,
EMI, and ESD compliance ensure world-wide acceptance. All units
bear the CE Mark.
Wide dynamic output current and fixed frequency operation simplifies
system level operation. The MAP110 series is configured to an
international standard footprint. Input and output connections are
made via popular single-row Molex connectors.
Single output models feature wide-range output adjustability to meet a
wide variety of standard and user specific output voltage requirements.
FEATURES
• New 3.3V and 5V Output Models
• Universal Input 85-264 VAC
• Industry Standard Footprint: 7.00" x 4.30" x 1.97"
(177.8mm x 109.2mm x 50.0mm)
• Input Transient & ESD Compliance to EN61000-4-2/-3/-4
• Greater than 134,000 Hours MTBF
• Remote Sense and Over-Voltage Protection on Single Output
Units and Main Output of Multiple Output Units
• Options Include Over-Temperature Protection,
Power Fail Signal, Chassis & Cover
SINGLE OUTPUT MODEL SELECTION CHART
MODEL
OUTPUT
VOLTAGE
MAP110-1005
5V
MAP110-1012 12V/15V
MAP110-1024 24V/28V
ADJUSTMENT
RANGE
CONVECTION COOLED
OUTPUT CURRENT
FORCED AIR
OUTPUT CURRENT
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 1)
INITIAL SETTING
ACCURACY
4.95V to 5.50V
11.25V to 15.75V
22.8V to 29.2V
16A
7.5/6A (Note 2)
3.8/3.2A (Note 2)
22A
10/8A (Note 2)
5.0/4.3A (Note 2)
0.2%
0.1%
0.1%
1%
0.5%
0.5%
1%
1%
1%
5.09V to 5.11V
11.97V to 12.02V
23.95V to 24.05V
NOTES: 1) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
2) MAP110-1012 output currents are expressed as 12V/15V operation. MAP110-1024 output currents are expressed as 24V/28V operation.
MULTIPLE OUTPUT MODEL SELECTION CHART – 80W CONVECTION COOLED, 110W FORCED AIR COOLED (200 LFM)
MODEL
MAP110-4000
MAP110-4001
MAP110-4002
MAP110-4003
MAP110-4004
Rev. 03/2001
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
CONVECTION COOLED
CURRENT (NOTE 1)
FORCED AIR
CURRENT
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
+5V
+12V
-12V
-5V
+5V
+24V
-12V
+12V
+5V
+12V
-12V
+12V
+5V
+15V
-15V
-5V
+5V
+24V
-15V
+15V
4.75V to 5.25V
Fixed
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
Fixed
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/7.3A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/7.3A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
0.2%
0.2%
0.2%
0.2%
0.2%
0.1%
0.1%
0.1%
0.2%
0.1%
0.1%
0.1%
0.2%
0.1%
0.1%
0.2%
0.2%
0.1%
0.1%
0.1%
0.5%
1%
1%
1.5%
0.5%
1%
1%
1%
0.5%
1%
1%
1%
0.5%
1%
1%
1.5%
0.5%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
5.09V to 5.11V
11.97V to 12.03V
-11.4V to -12.6V
-4.75V to -5.25V
5.09V to 5.11V
23.94V to 24.06V
-11.4V to -12.6V
11.4V to 12.6V
5.09V to 5.11V
11.97V to 12.03V
-11.4V to -12.6V
11.4V to 12.6V
5.09V to 5.11V
14.96V to 15.04V
-14.3V to -15.7V
-4.75V to -5.25V
5.09V to 5.11V
23.94V to 24.06V
-14.3V to -15.7V
14.3V to 15.7V
1
MAP110 SERIES
MULTIPLE OUTPUT MODEL SELECTION CHART (CONT.) – 80W CONVECTION COOLED, 110W FORCED AIR COOLED (200 LFM)
MODEL
MAP110-4010
MAP110-4011
MAP110-4015
MAP110-4200
New
MAP110-4300
(Note 3)
New
MAP110-4305
(Note 3)
NOTES:
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
CONVECTION COOLED
CURRENT (NOTE 1)
FORCED AIR
CURRENT
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
+5V
+12V
-5V
-12V
+5V
+12V
-12V
+24V
+5V
+12V
-15V
+15V
+12V
+24V
-12V
+5V
+3.3V
+5V
-12V
+12V
+3.3V
+5V
-5V
+12V
4.75V to 5.25V
Fixed
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
Fixed
11.55V to 12.45V
Fixed
Fixed
Fixed
3.2V to 3.4V
Fixed
Fixed
Fixed
3.2V to 3.4V
Fixed
Fixed
Fixed
12A/20A PK
5A/9A PK
1A/1.5A PK
3A/4A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
5A/9A PK
4A/4.5A PK
1A/1.5A PK
2A/2.5A PK
12A/20A PK
5A/12A PK
1A/1.5A PK
1A/1.5A PK
12A/15A PK
5A/12A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
3A/4A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
5A/9A PK
4A/4.5A PK
1A/1.5A PK
2A/2.5A PK
15A/20A PK
8A/12A PK
1A/1.5A PK
1A/1.5A PK
15A/20A PK
8A/12A PK
1A/1.5A PK
1A/1.5A PK
0.2%
0.1%
0.2%
0.3%
0.2%
0.1%
0.1%
0.1%
0.2%
0.1%
0.1%
0.1%
0.2%
0.2%
0.2%
0.2%
0.3%
0.2%
0.1%
0.1%
0.3%
0.2%
0.1%
0.1%
0.5%
2%
1.5%
8%
0.5%
1%
1%
1%
0.5%
1%
1%
1%
0.5%
1%
1%
1.5%
0.7%
1%
1%
1%
0.7%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
0.5%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
5.09V to 5.11V
11.97V to 12.03V
-4.75V to -5.25V
-11.5V to -12.5V
5.09V to 5.11V
11.97V to 12.03V
-11.4V to -12.6V
23.2V to 24.8V
5.09V to 5.11V
11.97V to 12.03V
-14.4V to -15.6V
14.4V to 15.6V
11.96V to 12.03V
23.94V to 24.06V
-11.4V to -12.6V
4.75V to 5.25V
3.29V to 3.31V
4.98V to 5.02V
-11.4V to -12.6V
11.4V to 12.6V
3.29V to 3.31V
4.98V to 5.02V
-4.75V to -5.25V
11.4V to 12.6V
1) Peak loads up to 110 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 110 Watts.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3) Sum of the output currents of V1 + V2 may not exceed 15A continuous, 22A peak.
MAXIMUM OUTPUT RATING:
MODEL/OUTPUT
OPTION
CONVECTION
CONTINUOUS/PEAK
FORCED AIR
200 LFM
MULTIPLE OUTPUT
BOARD ONLY
SINGLE OUTPUT
BOARD ONLY
MULTIPLE OUTPUT
‘L’-BRACKET
SINGLE OUTPUT
‘L’-BRACKET
MULTIPLE OUTPUT
‘C’-COVER
SINGLE OUTPUT
C’-COVER
80W/110W
90W/120W
80W/110W
90W/120W
60W/110W
65W/120W
110W
120W
110W
120W
110W
120W
INPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-up Time
85
47
85
40
20
Input Protection
Inrush Surge Current
Continuous input range.
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC input voltage (110 VAC)
50% load:
Full rated load:
85 VAC (110W load).
110VAC (110W load).
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264 VAC (one cycle). 25°C.
Operating Frequency
Switching frequency of main transformer, (fixed frequency).
20
Input Current
2
NOM
MAX
UNITS
264
63
VAC
Hz
VAC
mS
3.5
2.8
ARMS
41
APK
25
kHz
MAP110 SERIES
OUTPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
Efficiency
Minimum Loads
Full load, 230 VAC. Varies with distribution of loads among outputs.
Single output models.
Multiple output models, V1 + V2 (Note 1).
Full Load, 20 MHz Bandwidth.
Multiple output units with convection cooling.
Multiple output units with 200 LFM forced air cooling.
Output voltage overshoot/undershoot at turn-on.
Varies by output, regulation includes: line changes from 90-132
VAC or 175-264, changes in load starting at 20% load and changing
to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output only on multiple output units).
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
65
0
1
75
80
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
5
5
UNITS
%
Amps
Amps
See Model Selection Chart.
80
Watts
110
Watts
0
V
See Model Selection Chart.
500
1
20
µS
Sec
mS
NOM
MAX
UNITS
150
7.20
20.2
37.8
16.2
4.35
6.75
200
%
250
mV
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
CONDITIONS/DESCRIPTION
Overvoltage Protection
Provided on single output models and the
main output of multiple output models.
Overload Protection
Remote Sense
Input Power Fail
Warning
Overtemperature Protection
MIN
MAP110-1005
MAP110-1012
MAP110-1024
MAP110-4200
MAP110-4300
All other models.
Fully protected against output overload and short circuit.
Automatic recovery upon removal of overload condition.
Voltage drop compensated for at the load.
Option, TTL compatible logic signal. Time before regulation dropout due
to loss of input power at 110 VAC. Active low.
Option, system shutdown due to excessive internal temperature.
6.10
17.3
32.2
13.8
3.7
5.75
3
5
MIN
NOM
V
mS
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Agency Approvals
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TUV).
Input to Output.
FCC CFR title 47 part 15 sub-part B - conducted & radiated.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated (Note 2).
EN61000-4-5 level 3.
Input to output.
Per EN60950, 264 VAC.
Dielectric Withstand Voltage
Electromagnetic
Interference,
Conducted
Input Transient Protection
Insulation Resistance
Leakage Current
UNITS
Approved.
2600
VDC
B
B
A
Class
2
10
NOTES: 1) Minimum load is required only to meet the regulation limits of V3 and V4. If V3 and V4 are unused, no minimum load is necessary.
2) The following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300.
3
MAX
750
kV
M⍀
µA
MAP110 SERIES
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Altitude
Operating.
Non-operating.
Derate linearly above 50°C by 2.5% per° C
to a maximum temperature of 70°C.
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
MIN
At 100% load:
At 50% load:
0°C to 70°C.
Non-condensing.
NOM
0
0
-55
±0.03
MAX
UNITS
10k
50k
50
70
85
±0.05
95
ASL Ft.
ASL Ft.
°C
°C
°C
%/°C
%RH
OPTIONS
DESCRIPTION
NOTES
L-Bracket
Add ‘L’ suffix to model number.
DIMENSIONS
Cover
Add ‘C’ suffix to model number. Includes L-Bracket.
Power Fail
Signal
Thermal
Shutdown
Add ‘P’ suffix to model number. Provides >5 mS typical warning time before
main output drops 5%. Warning time increases at reduced load levels.
Add ‘T’ suffix to model number. Initiates shut-down in the event of an overtemperature
condition. Automatic recovery.
7.15" x 4.50" x 2.40"
(182.0mm x 115.0mm x 61.0mm)
7.20" x 4.50" x 2.40"
(183.0mm x 115.0mm x 61.0mm)
N/A
N/A
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
4
MAP110 SERIES
OVERALL SIZE: 7.00" X 4.30" X 1.97" (177.8mm x 109.2mm x 50.0mm)
OVERALL WEIGHT: 1.3 LBS (0.59 kg)
NOTE 1
Contact factory for dimensions for L-bracket and cover.
5