POWER-ONE MAP40-3000

MAP30/40/42 SERIES
Power-One’s MAP30/40/42 series of power supplies combines low cost
and universal input in a board-only power solution to meet
commercial and industrial requirements. Full international safety,
EMI, and ESD compliance ensure world-wide acceptance. All units
bear the CE Mark.
Fixed frequency operation simplifies system level operation. The
MAP30/40/42 series is configured to the international standard 3.00"
x 5.00" footprint. Input and output connections are made via popular
single row Molex connectors.
Single output models feature wide-range output adjustability to meet a
wide variety of standard and user specific output voltage requirements.
FEATURES
• Universal Input 85-264 VAC
• CE Marked to Low Voltage Directive
• Input Transient & ESD Compliance to EN61000-4-2/-3/-4
• Meets EN55022 Conducted and Radiated Limits
• Greater than 311,000 Hours MTBF
• Remote Sense (MAP30, MAP42)
SINGLE OUTPUT MODEL SELECTION CHART
MODEL
MAP30-1005
MAP42-1005
MAP42-1012
MAP42-1024
NOTES:
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT
PEAK OUTPUT
CURRENT (NOTE 2)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 1)
INITIAL SETTING
ACCURACY
5V
5V
12V/15V
24V/28V
4.7V to 5.8V
4.7V to 5.8V
11.0V to 18.0V
23.0V to 29.0V
6A
8A
3.4/2.7A (Note 3)
1.7/1.4A (Note 3)
8A
11A
4.6/3.7A (Note 3)
2.3/1.9A (Note 3)
0.2%
0.2%
0.2%
0.2%
±1%
±1%
1%
1%
1%
1%
1%
1%
4.9V to 5.1V
4.9V to 5.1V
11.9V to 12.1V
23.8V to 24.2V
1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
2) Peak ratings may be used as maximum output current with 100 Linear Feet per Minute (LFM) forced air cooling.
3) MAP42-1012 output currents are expressed as 12V/15V operation. MAP42-1024 output currents are expressed as 24V/28V operation.
MULTIPLE OUTPUT MODEL SELECTION CHART – 40W CONTINUOUS OUTPUT POWER
MODEL
MAP40-3000
MAP40-3100
MAP40-3101
MAP40-3105
MAP40-3500
MAP40-3003
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT
PEAK OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
+5V
+12V
-12V
+5V
+12V
-12V
+5V
+24V
-12V
+5V
+12
-5V
+5V
+12V
-12V
+5V
+15V
-15V
4.75V to 5.50V
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
4.7V to 5.8V
Fixed
Fixed
4.7V to 5.8V
Fixed
Fixed
4.7V to 5.8V
Fixed
Fixed
3A
2A
0.3A
3A
2A
0.3A
3A
1A
0.3A
3A
2A
0.5A
5A
1A
0.3A
3A
1.5A
0.2A
5A
3.5A
0.5A
5A
3.5A
0.5A
5A
1.5A
0.5A
5A
3.5A
1.0A
6A
3.5A
0.5A
5A
3A
0.5A
0.2%
1%
1%
0.2%
1%
1%
0.2%
1%
1%
0.2%
1%
1%
0.2%
1%
1%
0.2%
1%
1%
2%
3.5% (Note 3)
2% (Note 4)
2%
3.5% (Note 3)
2%
2%
3.5% (Note 3)
2%
2%
3.5% (Note 3)
2%
2%
3.5% (Note 3)
2%
2%
3.5% (Note 3)
2% (Note 4)
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
4.9V to 5.1V
11.5V to 12.5V
-11.4V to -12.6V
4.9V to 5.1V
11.5V to 12.5V
-11.4V to -12.6V
4.9V to 5.1V
23.0V to 25.0V
-11.5V to -12.5V
4.9V to 5.1V
11.5V to 12.5V
-4.75V to -5.25V
4.9V to 5.1V
11.5V to 12.5V
-11.4V to -12.6V
4.9V to 5.1V
14.7V to 15.3V
-14.3V to -15.7V
NOTES : 1) Peak loads for 30 seconds or less are acceptable, (10% duty cycle max.).
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
3) Quasi regulated output. See Regulation Curves for more information.
4) Requires a minimum load of 0.5A on V1 or 0.3A on V2.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments,
or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are
subject to change without notice.
Rev. 10/2000
1
MAP30/40/42 SERIES
INPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Input Voltage - AC
Continuous input range.
MIN
Input Frequency
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC Input Voltage (115VAC), full rated load.
90 VAC (40W load).
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C.
Operating Frequency
Switching frequency of power supply (fixed frequency).
MAP42
MAP30, MAP40
NOM
85
90
47
85
15
MAX
UNITS
264
264
63
VAC
1.2
Hz
VAC
mS
ARMS
38
APK
23
25
30
kHz
MIN
NOM
MAX
UNITS
OUTPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Efficiency
Minimum Loads
Turn-on Delay
Full load, 120VAC.
Single output models; MAP30, MAP42.
All multiple output models, see regulation graphs.
Full load, 20MHz bandwidth.
Multiple output models with convection cooling.
Output voltage overshoot/undershoot at turn-on, V1.
Varies by output, total regulation includes: Line changes from 90-132
VAC or 175-264, changes in load starting at 20% load and changing
to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output only of multiple output units).
Time required for initial output voltage stabilization.
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90%.
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
70
%
Amps
0.0
See Model Selection Chart.
40
Watts
1
%
See regulation graphs.
µS
500
1
2
20
Sec
mS
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
Overvoltage
Protection
Overload
Protection
Remote Sense
CONDITIONS/DESCRIPTION
MIN
MAP30-1005, MAP42-1005
MAP42-1012
MAP42-1024
Main output only of multiple output units.
Fully protected against output overload and short circuit. Automatic
recovery upon removal of overload condition.
Total cable drop, single output models only.
5.8
20.0
32.0
5.8
NOM
MAX
UNITS
6.8
22.0
37.0
6.8
V
130
%
250
mV
MAX
UNITS
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Agency Approvals
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TUV).
Input to output.
Dielectric Withstand
Voltage
Electromagnetic
Interference
Input Transient
Protection
Insulation Resistance
Leakage Current
MIN
Approved.
2600
FCC CFR title 47 part 15 sub-part B - conducted.
EN55022 / CISPR 22 conducted (Note 1).
EN55022 / CISPR 22 radiated (Note 2).
EN61000-4-5 Level 3
Input to output.
Per EN60950, 264VAC
NOM
B
B
B
Line to Line
Line to Ground
MAP42, MAP40-3100, 3001, 3105, 3500
MAP30-1005, MAP40-3000, MAP40-3003
NOTES: 1) MAP30-1005, MAP40-3000, MAP40-3003 meet Class A.
2) MAP40-3000, MAP40-3003, MAP3500 meet Class A.
2
VDC
Class
1
2
7
kV
MΩ
500
750
µA
MAP30/40/42 SERIES
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Altitude
Operating.
Non-operating.
Derate linearly above 50°C by 2.5%
per °C to a maximum temperature of 70°C.
At 100% load:
At 50% load:
±0.02
5
MAP40-3500 TYPICAL QUASI REGULATION
PERFORMANCE FOR +12V OUTPUT
14.25
12V OUTPUT VOLTAGE
13.75
13.25
12.75
+5V @ 5.0 Amps
12.25
+5V @ 3.0 Amps
+5V @ 1.0 Amps
11.75
+5V @ 0 Amps
11.25
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
12V OUTPUT CURRENT
MAP40-3000/3100/3105 TYPICAL QUASI REGULATION
PERFORMANCE FOR +12V OUTPUT
13.5
13.0
12.5
12.0
+5V @ 3.0 Amps
+5V @ 1.8 Amps
11.5
+5V @ 0.6 Amps
+5V @ 0 Amps
11.0
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
12V OUTPUT CURRENT
MAP40-3003 TYPICAL QUASI REGULATION
PERFORMANCE FOR +15V OUTPUT
17.0
16.5
16.0
15.5
15.0
+5V @ 3.0 Amps
+5V @ 1.8 Amps
14.5
+5V @ 0.6 Amps
+5V @ 0 Amps
14.0
13.5
0
0.15
0.3
0.45
0.6
NOM
0
0
-40
0°C to 70°C (after 15 minute warm-up).
Non-condensing.
Operating, peak acceleration.
Random vibration, 10Hz to 2kHz, 3 axis.
12V OUTPUT VOLTAGE
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
15V OUTPUT VOLTAGE
Operating Temperature
MIN
0.75
0.9
15V OUTPUT CURRENT
3
1.05
1.2
1.35
1.5
MAX
UNITS
10k
40k
50
70
85
±0.03
95
20
6
ASL Ft.
ASL Ft.
°C
°C
°C
%/°C
%RH
G
GRMS
MAP30/40/42 SERIES
OVERALL SIZE: 5.00" x 3.00" x (see table) (127.0mm x 76.2mm x see table)
WEIGHT: 0.6 LBS (0.26 kg)
5.00"
(127.0mm)
0.23"
(5.7mm)
4.55"
(115.6mm)
2.55"
(64.8mm)
J2
J1
3.00"
(76.2mm)
0.16" (4.0mm) Diameter
Diameter Mounting Holes (4 Places)
0.25"
(6.4mm)
see table
COMPONENT LEAD LENGTH 0.10" (2.5mm) MAX
ELECTRICAL CONNECTORS
J1
NEUTRAL
MAP30 J2
PIN 1
PIN 7
N/C
V1
V1
GND
GND
+Sense
-Sense
PIN 2 (REMOVED)
LINE
PIN 3
SAFETY EARTH GROUND
(0.250" x 0.032" FASTON)
MAP40 J2
PIN 1
PIN 6
PIN 1
V2
V1
V1
GND
GND
V3
MAP42 J2
PIN 6
PIN 1
J1/J2 MATES WITH MOLEX (SERIES 2139 or SERIES 41695) .156" (4mm)
CENTER CRIMP TERMINAL HOUSING OR EQUIVALENT
MAP30/40/42 SERIES HEIGHT
Single Output Models
Multiple Output Models
Model
Height
Model
Height
MAP30-1005
MAP42-1005
MAP42-1012
MAP42-1024
1.16" (29.5)
1.25" (31.8)
1.25" (31.8)
1.25" (31.8)
MAP40-3000
MAP40-3003
MAP40-3100
MAP40-3101
MAP40-3105
MAP40-3500
1.16" (29.5)
1.16" (29.5)
1.25" (31.8)
1.25" (31.8)
1.25" (31.8)
1.60" (40.6)
4
V1
V1
GND
GND
+Sense
-Sense