ETC 25CPV240

Series CPV
Phase Control Modules
• 120 & 240 Vac Models
• 0-5 Vdc Phase Control
Models CPV120 and CPV240 auxiliary
function modules provide control of the
phased turn-on of a solid state relay, in
response to the application of a 0-5 Vdc
control signal. They must be used with
MODEL NUMBERS
Crydom Series 1 (-10) random turn-on
solid state relays. Consult factory about
use with 480 Vac loads. For a complete set (control module and solid state
relay) order 10CPV120, 25CPV120, etc.
Manufactured in Crydom’s ISO 9002
Certified facility for optimum product
performance and reliability.
120 Vac
10CPV120
25CPV120
40CPV120
240 Vac
10CPV240
25CPV240
50CPV240
75CPV240
90CPV240
RELAY OUTPUT SPECIFICATIONS ➀
90-140 (120 Vac Models)
180-280 (240 Vac Models)
Operating Voltage Range (47-63 Hz) [Vrms]
Load Current Range ➂ [Arms]
.04-10
.04-25
.04-50
.04-75
.04-90
400 (120 Vac models)
600 (240 Vac models)
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
120
250
625
1000
1200
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
1.6
1.48
1.02
0.63
0.31
0.28
60
260
1620
4150
6000
Max. Off-State Leakage Current @ Rated Voltage [mArms]
10.0
10.0
10.0
10.0
10.0
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁
500
500
500
500
500
Thermal Resistance Junction to Case [RθJC] °C/W
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
0.02
Max. Turn-On Time [msec]
1/
2
Max. Turn-Off Time
0.02
cycle
0.5
Power Factor (Min.) with Max. Load
1/
2
0.02
1/
2
cycle
0.5
CONTROL MODULE INPUT SPECIFICATIONS ➀
cycle
0.5
0.02
1/
2
cycle
0.5
0.02
1/
2
cycle
0.5
DC CONTROL
3.5-10Vdc
Logic Supply Range (Terminal 3A)
1.6mA @ 5Vdc
Typical Supply Current
0-5 Vdc
Control Voltage Range (Terminal 3B)
1500 Ohms
Nominal Control Input Impedance
1.0
Min. Turn-Off Voltage
CONTROL MODULE OUTPUT (Terminal 4B – Input to Relay) ➀
Max. Off-State Operating Voltage
36 Vdc
Max. Load Current (Sink)
3.0 mA
Max. On-State Voltage @ 3mA
0.5 Vdc
Max. Off-State Leakage @ 10Vdc
GENERAL NOTES
➀ All parameters at 25ºC unless otherwise specified.
➁ Off-State dv/dt test method per
EIA/NARM standard RS-443,
paragraph 13.11.1
➂ Heat sinking required (Relay Only),
see Series 1 data sheet.
FastFax Document No. 203
SERIES CPV.040898, PAGE 1 OF 2
1.0 µAdc
©1998 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected]
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340
85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany
Series CPV
Phase Control Modules
GENERAL SPECIFICATIONS
Dielectric Strength, Signal to Load
4000 Vrms
Dielectric Strength, Signal to Base
4000 Vrms
Ambient Operating Temperature Range
-30 to 80ºC
Ambient Storage Temperature Range
-40 to 125ºC
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (43g)
Encapsulation:
AVAILABLE OPTIONS
CPV120 Control Module Only (120 Vac line)
CPV240 Control Module Only (120 Vac line)
Thermally Conductive Epoxy
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1.10
(27.9)
.50
(12.7)
.270 (2)
(6.9)
FASTON TERMINAL
.250 X .032
4 PLCS.
DERATING CURVES – See Series 1
2.30
(58.4)
1.70
(43.2)
1.87
(47.5)
1A 1B
Positive
Supply (+)
(5Vdc)
2B 2A
CONTROL MODULE
+
3B 3A
-4A 4B
Control
Voltage (+)
(0 to 5Vdc)
Common (–)
1.00
(25.4)
1.80
(45.7)
.270 FASTON
(6.9) TERMINAL
.187 X .032
4 PLCS.
.78
(19.8)
.87
(22.2)
All dimensions are in inches (millimeters)
Line
Load
OUTPUT
1
2
–10 RELAY
4
3
INPUT
Notes
1. Following pins may be interchanged: 1A & 1B, 2A & 2B.
2. Pin 4A & 4B may not be interchanged, nor may pins 3A & 3B.
3. The line and load may be interchanged.
©1998 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No. 203
SERIES CPV.040898, PAGE 2 OF 2
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected]
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340
85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany