Series CPV Phase Control Modules • 120 & 240 Vac Models • 0-5 Vdc Phase Control Models CPV120 and CPV240 auxiliary function modules provide control of the phased turn-on of a solid state relay, in response to the application of a 0-5 Vdc control signal. They must be used with MODEL NUMBERS Crydom Series 1 (-10) random turn-on solid state relays. Consult factory about use with 480 Vac loads. For a complete set (control module and solid state relay) order 10CPV120, 25CPV120, etc. Manufactured in Crydom’s ISO 9002 Certified facility for optimum product performance and reliability. 120 Vac 10CPV120 25CPV120 40CPV120 240 Vac 10CPV240 25CPV240 50CPV240 75CPV240 90CPV240 RELAY OUTPUT SPECIFICATIONS ➀ 90-140 (120 Vac Models) 180-280 (240 Vac Models) Operating Voltage Range (47-63 Hz) [Vrms] Load Current Range ➂ [Arms] .04-10 .04-25 .04-50 .04-75 .04-90 400 (120 Vac models) 600 (240 Vac models) Transient Overvoltage [Vpk] Max. Surge Current, (16.6ms) [Apk] 120 250 625 1000 1200 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 1.6 1.48 1.02 0.63 0.31 0.28 60 260 1620 4150 6000 Max. Off-State Leakage Current @ Rated Voltage [mArms] 10.0 10.0 10.0 10.0 10.0 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁ 500 500 500 500 500 Thermal Resistance Junction to Case [RθJC] °C/W Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 0.02 Max. Turn-On Time [msec] 1/ 2 Max. Turn-Off Time 0.02 cycle 0.5 Power Factor (Min.) with Max. Load 1/ 2 0.02 1/ 2 cycle 0.5 CONTROL MODULE INPUT SPECIFICATIONS ➀ cycle 0.5 0.02 1/ 2 cycle 0.5 0.02 1/ 2 cycle 0.5 DC CONTROL 3.5-10Vdc Logic Supply Range (Terminal 3A) 1.6mA @ 5Vdc Typical Supply Current 0-5 Vdc Control Voltage Range (Terminal 3B) 1500 Ohms Nominal Control Input Impedance 1.0 Min. Turn-Off Voltage CONTROL MODULE OUTPUT (Terminal 4B – Input to Relay) ➀ Max. Off-State Operating Voltage 36 Vdc Max. Load Current (Sink) 3.0 mA Max. On-State Voltage @ 3mA 0.5 Vdc Max. Off-State Leakage @ 10Vdc GENERAL NOTES ➀ All parameters at 25ºC unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required (Relay Only), see Series 1 data sheet. FastFax Document No. 203 SERIES CPV.040898, PAGE 1 OF 2 1.0 µAdc ©1998 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected] WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany Series CPV Phase Control Modules GENERAL SPECIFICATIONS Dielectric Strength, Signal to Load 4000 Vrms Dielectric Strength, Signal to Base 4000 Vrms Ambient Operating Temperature Range -30 to 80ºC Ambient Storage Temperature Range -40 to 125ºC MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (43g) Encapsulation: AVAILABLE OPTIONS CPV120 Control Module Only (120 Vac line) CPV240 Control Module Only (120 Vac line) Thermally Conductive Epoxy MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1.10 (27.9) .50 (12.7) .270 (2) (6.9) FASTON TERMINAL .250 X .032 4 PLCS. DERATING CURVES – See Series 1 2.30 (58.4) 1.70 (43.2) 1.87 (47.5) 1A 1B Positive Supply (+) (5Vdc) 2B 2A CONTROL MODULE + 3B 3A -4A 4B Control Voltage (+) (0 to 5Vdc) Common (–) 1.00 (25.4) 1.80 (45.7) .270 FASTON (6.9) TERMINAL .187 X .032 4 PLCS. .78 (19.8) .87 (22.2) All dimensions are in inches (millimeters) Line Load OUTPUT 1 2 –10 RELAY 4 3 INPUT Notes 1. Following pins may be interchanged: 1A & 1B, 2A & 2B. 2. Pin 4A & 4B may not be interchanged, nor may pins 3A & 3B. 3. The line and load may be interchanged. ©1998 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No. 203 SERIES CPV.040898, PAGE 2 OF 2 For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected] WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany