FUJITSU MB89R118_06

FUJITSU MICROELECTRONICS
DATA SHEET
DS04-33101-4Ea
ASSP
ISO/IEC 15693 Compliant FRAM Embedded
High-speed RFID LSI FerVID familyTM
MB89R118
■ DESCRIPTION
The MB89R118 is an LSI device that has built-in high-speed, large-capacity FRAM and is used for vicinity-RFID.
■ FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
•
Memory capacity of 2 Kbytes FRAM (including 2,000 bytes of user area)
8-byte/block configuration, 256 blocks
High-speed data transmission and reception at 26.48 kbps
Fast command supported (data transmission at 52.97 kbps) (Transponder → Reader/Writer)
Carrier frequency at 13.56 MHz
Anti-collision function : 30 tags per second
Endurance : 1010 writes to memory
Data Retention : 10 years (Ta = 0 °C to + 55 °C)
64-bit UID
FRAM memory data protection
Anti-theft (EAS) command
Compliance with ISO/IEC 15693 (partly not supported*)
Compliance with ISO/IEC 18000-3 (Mode 1) (partly not supported*)
* : Refer to “■ NOTES ON USING”.
FerVID family is a trademark of Fujitsu Microelectronics Limited, Japan.
Copyright©2004-2008 FUJITSU MICROELECTRONICS LIMITED All rights reserved
2006.9
MB89R118
■ BLOCK DIAGRAM
Analog RF interface
Antenna
coil
Digital control
Rectifier
Clock generator
Power supply
voltage control
Modulator
VDD
Anti-collision
function
Clock
Demodulator
Data output
I/O
Commands
Data input
Data output
FRAM access
2
FRAM
Data input
R/W
2 Kbytes
MB89R118
■ MEMORY MAP
This section describes the FRAM memory, which is the internal memory of the MB89R118.
• FRAM Configuration
The FRAM has 2,000 bytes for use as user area and 48 bytes for use as system area.
The FRAM memory areas consist of a total of 256 blocks (250 blocks of user area and 6 blocks of system area).
Each block can store 64 bits (8 bytes) of data.
The block is the unit used for the writing and reading of FRAM data. The memory configuration of FRAM is
shown below.
• FRAM memory configuration
Area
Block No.
Details
Data read
Data write
User area (2000 bytes)
System area (48 bytes)
00H to F9H
User area
Yes
Yes
FAH
UID (64 bits)
Yes
No
FBH
AFI, DSFID, EAS,
security status
Yes
Limited
FCH to FFH
Block security status
Yes
No
Blocks “00H” to “F9H” are user area. The user area is defined as an area that can be accessed when the
corresponding block address is specified. On the other hand, Blocks “FAH” to “FFH” are system area. The system
area is defined as an area that can be accessed only with a specific command.
The system area consists of 6 blocks and contains UID, AFI, DSFID, EAS bits, and security status (can write or
cannot write) data for individual block. UID is fixed and cannot be updated. AFI, DSFID, and EAS bits are written
at the factory, and can be updated and locked (disable to write) with commands (Only EAS bit cannot be locked) .
As shown in above, “FAH” holds the UID, and “FCH” to “FFH” hold the security status information on individual
user areas.
The configuration of “FBH” to “FFH” blocks is shown below. “FBH” block is used for EAS status, AFI and DSFID
data, the security status data of AFI and DSFID. “FCH” to “FFH” blocks contain block security status data.
• Structure of “FBH”
MSB
64
LSB
57 56
EAS
Status
33
RFU*
32
25
24
17
DSFID
Lock
AFI
Lock
Status
Status
16
DSFID
9
8
1
AFI
* : Reserved for future use
3
MB89R118
• Structure of “FCH” to “FFH”
Block security status (BSS) of user
block 3FH
Block security status (BSS) of user
block 00H
MSB
LSB
FCH
3F
3E
3D
3C
3B
3A
39
03
02
01
00
FDH
7F
7E
7D
7C
7B
7A
79
43
42
41
40
FEH
BF
BE
BD
BC
BB
BA
B9
83
C3
82
C2
81
C1
80
C0
FFH
RFU* (6 bits)
F9
* : Reserved for future use
The security status of the user area is stored in the block security status bit in system area blocks of “FCH” to
“FFH” per bit in each block. A user area is unlocked when the corresponding block security status bit is “0”; it is
locked (disable to write state) when the corresponding block security status bit is “1”.
EAS bit is a single bit, and it is used for setting EAS status. It is possible to read/write data of 2 blocks at one
time in the user area (If Read Multiple Blocks Unlimited command is used, up to 256 blocks can be accessed
at one time) .
4
MB89R118
■ DATA ELEMENT DEFINITION
1. Unique Identifier (UID)
The MB89R118 has a 64-bit unique identifier (UID) that complies with ISO/IEC 15693-3. The UID is used to
distinguish a transponder from another transponder in the anti-collision algorithm described later.
The UID consists of the 3 items shown in the following.
• An 8-bit data whose value is always “E0H” (bit 57 to bit 64)
• An 8-bit IC manufacturer code whose value is always “08H”, and is defined by ISO/IEC 7816-6/AMI
(bit 49 to bit 56)
• Unique 48-bit serial number assigned by Fujitsu Microelectronics (bit 1 to bit 48)
Among the unique 48-bit serial number assigned by Fujitsu Microelectronics, the 1 byte from bit 41 to bit 48
defines MB89R118 code whose value is “01H”. And the 5 bytes from bit 1 to bit 40 define Chip Information.
• Structure of UID
MSB
LSB
64
57 56
“E0H”
49 48
IC manufacturer
code “08H”
41 40
“01H”
1
Chip information
Unique serial number assigned by Fujitsu Microelectronics
5
MB89R118
2. Application Family Identifier (AFI)
The application family identifier (AFI) identifies the type of application set by the transponder.
The AFI can be written with a command. The AFI is 8-bit data and is stored in the system area of FRAM.
The factory default setting of the AFI is “00H”.
• Types of AFI
Application
Application
Sub-Family
Application Use Field
Example/Note
Family
(bit 8 to bit 5) (bit 4 to bit 1)
“0”
“0”
All families and sub-families
No application preselection
X
“0”
All sub-families of family X
X
Y
Only the Yth sub-families of family X
“0”
Y
All families of Yth sub-families
“1”
“0”, Y
Transport
Mass transit, bus, airline
“2”
“0”, Y
Financial
IEP, banking, retail
“3”
“0”, Y
Identification
“4”
“0”, Y
Telecommunication
“5”
“0”, Y
Medical
“6”
“0”, Y
Multimedia
“7”
“0”, Y
Gaming
“8”
“0”, Y
Data storage
“9”
“0”, Y
“A”
“0”, Y
ISO/IEC JTC1/SC31
“B”
“0”, Y
IATA
Managed by ISO/IEC JTC1/SC31
“C”
“0”, Y
UPU
Managed by ISO/IEC JTC1/SC31
“D”
“0”, Y
RFU*
Managed by ISO/IEC JTC1/SC31
“E”
“0”, Y
RFU*
Managed by ISO/IEC JTC1/SC31
“F”
“0”, Y
RFU*
Managed by ISO/IEC JTC1/SC31
Wide applicative preselection
Access control
Public telephone, GSM
Internet services
Portable files
EAN-UCC system for application identifiers Managed by ISO/IEC JTC1/SC31
Data identifiers as defined in
ISO/IEC15418
* : Reserved for future use
Note : Both X value and Y value are “1” to “F”.
In the status of the AFI_flag setting;
• If the AFI is not supported by the transponder, no response to all requests is returned.
• If the AFI is supported by the transponder, the response is returned only if the value is in accord with
the AFIsent from a reader/writer.
3. Data Storage Format Identifier (DSFID)
The data storage format identifier (DSFID) indicates how data is structured in the transponder (LSI memory
device). The DSFID can be programmed with a command.
The DSFID is 8-bit data and is stored in the system area of FRAM. The factory default setting of the DSFID is “01H”.
6
MB89R118
4. Cyclic Redundancy Check (CRC)
When a frame is received, reception of correct data--that is, the characters making up the frame is assumed
only when the value of the cyclic redundancy check (CRC) code is valid. For error-checking purposes, a 2-byte
CRC code value is inserted between data and the EOF signal.
The value of CRC code is required from all the data contained between the SOF and CRC field in each frame.
Method of calculation is provided in ISO/IEC 13239. The details are provided in ISO/IEC 15693-3 and ISO/IEC
18000-3 (Mode 1) . The initial value of the CRC code provided in ISO/IEC 15693-3 is “FFFFH”.
The CRC code is transferred, beginning with the lowest-order bit in the lowest-order byte.
• CRC bit/byte transition order
LSByte
LSBit
MSByte
MSBit
CRC 16 (8 Bits)
LSBit
MSBit
CRC 16 (8 Bits)
First transmitted bit of the CRC
5. Electronic Article Surveillance (EAS) status
EAS status is 1 bit data (LSB side) , which is stored in the system area of FRAM. The initial value is “1”. EAS
bit “1” means goods-monitoring status, and EAS bit “0” means that goods-monitoring status is cleared. EAS
status can be written by Write EAS command and can be checked “FBH” block (refer to “■ MEMORY MAP”) by
Read commands such as Read Single Block command.
Together with Gate type reader/writer, EAS command can support anti-theft security functions.
7
MB89R118
■ FUNCTION DESCRIPTION
1. Communication from Reader/Writer to Transponder
(1) Modulation method
The MB89R118 supports only 10% ASK modulation (Not supports 100% ASK modulation) .
Modulation rate m is defined as m = (a - b)/(a + b) with reference to the modulated waveform shown below. The
values a and b indicate, respectively, the maximum and minimum amplitude of magnetic field transmitted from
a reader/writer.
• Modulation waveform
hr
y
y
a
hf
t2
t1
t3
b
13.56 MHz
Maximum and minimum values of t1, t2 and t3 are shown in the following table. In this table, y is 0.05 (a-b) and
the maximum value of hf and hr is 0.1(a-b).
8
MB89R118
(2) Data rate and data coding
The MB89R118 supports only 1 out of 4 mode for bit coding (Not supports 1 out of 256 mode). In 1 out of 4
mode, 2-bit signals are coded in a period of 75.52 µs as shown in the following. When coding takes place, the
data rate is 26.48 kbps (fc/512). Each signal is transmitted beginning with the lowest bit.
• Coding Method in 1 out of 4 Mode
• “00B” pulse position
9.44 µs
9.44 µs
75.52 µs
• “01B” pulse position (1 = LSB)
28.32 µs
9.44 µs
75.52 µs
• “10B” pulse position (0 = LSB)
47.20 µs
9.44 µs
75.52 µs
• “11B” pulse position
66.08 µs
9.44 µs
75.52 µs
(3) Data frame
A data frame begins with a start of frame (SOF) signal and ends with an end of frame (EOF) signal.
The MB89R118 is enabled to receive a frame from a reader/writer within 300 µs after the MB89R118 has sent a
frame to the reader/writer. The MB89R118 is also enabled to receive a frame from a reader/writer within 3 ms after
power has been supplied to the MB89R118.
• Waveforms of SOF and EOF signals of a frame sent from a reader/writer
SOF
9.44 µs
9.44 µs
37.76 µs
9.44 µs
37.76 µs
EOF
37.76 µs
9.44 µs
9.44 µs
9
MB89R118
2. Communication from Transponder to Reader/Writer
• Minimum load modulation amplitude (Vlm) : 10 mV (based on ISO/IEC 10373-7)
• Load modulation subcarrier frequency (fs) : 423.75 kHz(fc/32)
The MB89R118 supports only a 1-subcarrier system.
(Not supports 2-subcarrier system.)
• Data rate : The MB89R118 supports the following 2 data rate modes :
• Low data rate
• High data rate
One of the 2 data rate modes is specified by the Data_rate_flag (described later) sent from
the reader/writer. In low data rate mode, the data rate is 6.62 kbps (fc/2048); in high data rate
mode, it is 26.48 kbps (fc/512).
When receiving the Fast commands (Custom commands) , the communication starts from the
transponder in the data rate that is twice as fast as normal data rate. In this case, the 2 data
rate modes of low data rate and high data rate specified by the Data_rate_flag is supported.
In Low data rate mode, the data rate is 13.24 kbps (fc/1024) ; in high data rate mode, it is
52.97 kbps (fc/256) .
(1) Bit coding
The Manchester coding is used for the bit coding. The following figures show the signals modulated in high data
rate mode when ISO command is received and the same signals when fast command is received. In low data
rate mode of both ISO commands and fast commands, the number of pulses for subcarrier and data transfer
time are 4 times as large as the number in high data rate mode.
• Signal waveforms by load modulation in high data rate mode (ISO commands)
• Logic 0
423.75 kHz subcarrier
18.88 µs (modulated)
18.88 µs
(not modulated)
37.76 µs
• Logic 1
423.75 kHz subcarrier
18.88 µs
(not modulated)
18.88 µs (modulated)
37.76 µs
10
MB89R118
• Signal waveforms by load modulation in high data rate response mode (fast commands)
• Logic 0
9.44 µs
9.44 µs
18.88 µs
• Logic 1
9.44 µs
9.44 µs
18.88 µs
(2) Data frame
A data frame sent from a transponder starts with a start of frame (SOF) signal and ends with an end of frame
(EOF) signal. The following figures show the SOF and EOF signals sent in high data rate mode when ISO
command is received and the same signals when fast command is received. In low data rate mode of both ISO
commands and fast commands, the number of pulses in subcarrier and data transfer time are 4 times as large
as the number in high data rate mode. The reader/writer shall be ready to receive a frame from the transponder
within 300 µs after having sent a frame to the transponder.
• Waveforms of SOF and EOF signals of a frame sent from a transponder (ISO commands)
• SOF
423.75 kHz subcarrier
56.64 µs
56.64 µs
37.76 µs
• EOF
37.76 µs
56.64 µs
56.64 µs
11
MB89R118
• Waveforms of SOF and EOF signals of a frame sent from a transponder (fast commands)
• SOF
423.75 kHz
Subcarrier
28.32 µs
28.32 µs
18.88 µs
• EOF
423.75 kHz
Subcarrier
18.88 µs
28.32 µs
28.32 µs
3. FRAM Data Protection if Power Lost During Data Writing
MB89R118 accesses to FRAM with the unit of 1 byte. When RF power is shut down during accessing FRAM,
writing in FRAM is completed by the charges stored in a smoothing capacitor on the LSI and FRAM data writing
error is prevented.
Therefore, the commands of 1 byte access such as Write AFI, Write DSFID, Write EAS, and Lock command
can protect the data from the power down.
On the other hand, the commands of more than 2 bytes access such as Write Single Block command may not
protect all the data from the power down during the access. In this case, it is recommended to confirm the data
by read command if it’s written correctly.
4. Requests/Responses
A request is sent from the reader/writer to the transponder. In reply to the request, the transponder sends a
response to the reader/writer.
Each request, and response, is transmitted in each single frame.
• Structure of requests and responses
A request consists of the following 5 fields :
• Flag
• Command code
• Parameter (required or optional depending on the command)
• Application data
• CRC
A response consists of the following 4 fields :
• Flag
• Parameter (required or option depending on the command)
• Application data
• CRC
Each byte is transferred, beginning with the lowest bit. When two or more bytes are transferred, transfer begins
with the lowest one.
12
MB89R118
5. Operating Modes
The MB89R118 has the following 3 operating modes :
Each mode specifies a different mechanism for how the transponder returns a response in reply to a request
from the reader/writer :
• Addressed mode
The MB89R118 enters addressed mode when the Address_flag is set to “1”.
In addressed mode, a request includes a UID (the Address_flag is set to “1” simultaneously), and only the
transponder that matches the UID in the request returns a response. If no transponder that matches the UID
exists, a response is not returned.
• Non-Addressed mode
The MB89R118 enters non-addressed mode when the Address_flag is set to “0”.
In non-addressed mode, a request does not include a UID. The transponders that receive the request execute
processing and return response in accordance with the command in the request.
• Select mode
The MB89R118 enters select mode when the Select_flag is set to “1”, and the address_flag is set to “0”.
In select mode, do not include a UID as a request. Of the transponders that receive the command, only the
transponder in the select state executes processing and returns a response in accordance with the command
in the request.
6. Request Format
The following figure shows a typical example of the request data format, and the following table shows the
definition of request flag bits.
• Structure of the request frame
SOF
Flag
Command code
• Setting of Bit 1 to Bit 4
Bit
Flag name
1
Sub-carrier_flag
2
Data_rate_flag
3
Inventory_flag
4
Protocol_Extension_flag
Parameter
1/0
Data
CRC
EOF
State/Description
0
1-subcarrier selected
1
2-subcarrier selected (not supported)
0
Low data rate (6.62 kbps) selected
1
High data rate (26.48 kbps) selected
0
Command other than Inventory command selected
1
Inventory command selected
0
Protocol not extended
1
Protocol extended (RFU*)
* : Reserved for future use
Note : “Inventory_flag” of bit3 is determined whether “Inventory command” (select “1”) or other command (select
“0”) is used.
13
MB89R118
• Setting of Bit 5 to Bit 8 (When Inventory command is selected [Inventory_flag = “1”])
Bit
Flag name
1/0
State/Description
5
AFI_flag
6
Nb_slots_flag
7
Option_flag
8
RFU*
0
AFI not set
1
AFI set (response when it is in accord with AFI of the
transponder)
0
16-slots (for one or more transponders)
1
1-slot (for one transponder)
0
Command option not supported
1
Command option supported (not supported)
0
Set to “0”

1
* : Reserved for future use
• Setting of Bit 5 to Bit 8 (When the command other than Inventory command is selected [Inventory_flag = “0”])
Bit
Flag name
1/0
State/Description
5
Select_flag
6
Address_flag
7
Option_flag
8
RFU*
0
Command flag decided by the setting of bit 6 and later bits.
1
Select mode (the response is sent by only the transponder in
select state)
0
Non-addressed mode (UID not included in the command)
1
Addressed mode (UID included in the command)
0
Command option not supported (for the command not
supporting the Option_flag)
1
Command option supported
0
Set to “0”

1
* : Reserved for future use
7. Response Format
The following figure shows a typical example of the response data format, and the following table shows the
definition of the response flag bits.
If the error flag is set to “1”, an error code field is generated in the response. If the error flag is set to “0”, this
means no error, and If the error flag is set to “1”, this means any error generation.
• Structure of the response frame
SOF
14
Flag
Parameter
Data
CRC
EOF
MB89R118
• Response flag definitions
Bit
Flag name
1/0
Description
0
Error not found
1
Error found
RFU*
0
Set to “0”
3
RFU*
0
Set to “0”
4
Extension_flag
0
Set to “0”
5
RFU*
0
Set to “0”
6
RFU*
0
Set to “0”
7
RFU*
0
Set to “0”
8
RFU*
0
Set to “0”
1
Error_flag
2
* : Reserved for future use
• Error code definitions
Error code
Meaning
“01”
The specific command is not supported. Example: Command code error
“02”
Cannot recognize the command. The number of blocks is over the limit. Example: Format error
“03”
Specific options are not supported.
“0F”
Other errors
“10”
The specified block cannot be used (or was not found).
“11”
The specified block has already been locked and cannot be locked again.
“12”
The specified block has already been locked, and its contents cannot be updated.
“13”
The specified block could not be programmed normally (a write verify error occurred).
“14”
The specified block could not be locked normally (a lock verify error occurred) .
Others
Unused.
8. Anti-Collision Algorithm
The MB89R118 executes an anti-collision sequence loop based on an algorithm that complies with ISO/IEC
15693-3.
The anti-collision algorithm is designed to examine the transponders located within reader/writer communication
areas on the basis of UID.
The reader/writer issues an Inventory command to transponders, and some transponders return responses
while other transponders do not according to the algorithm explained in “10. Execution of Inventory Command
by a Transponder”.
15
MB89R118
9. REQUEST PARAMETER
• Request Parameter Settings
Set the reader/writer as follows before issuing the Inventory command.
• The Nb_slots_flag (bit6), which is a request flag, is set to the desired value :
“0” : 16 slots (for plural transponders)
“1” : 1 slot (for single transponder)
• A mask length and a mask value are added after the command code.
• The mask length represents the data length of the mask value in bits.
• The mask value is integer bytes of data, transmitted beginning with the lowest bit. If the mask data is not
a multiple of 8 (bits) in length, 0 is padded on the MSB side of the mask value so that the data is in units of bytes.
The following figure shows an example of the mask value with padding. Since the mask length is 12 bits, the
mask value is padded with 4 bits on the MSB side so that the mask data is in units of bytes (2 bytes = 16 bits in
this case).
If the AFI flag in the request flags is set in the format explained in “• Structure of the request frame of 6 Request
Format”, an AFI field is added to the format. The command ends with transmission of an EOF signal as described
in “1. Communication from Reader/Writer to Transponder”. Thereafter, processing in the first slot starts immediately. To proceed to the next slot, the reader/writer sends an EOF signal.
• Format of the Command
SOF
Flag
Command code Optional AFI Mask length
8 bits
8 bits
8 bits
8 bits
• Example of the Mask Value with Padding
MSB
16
LSB
0000
0100 1100 1111
Pad
Mask value
Mask value
CRC
0 to 64 bits
16 bits
EOF
MB89R118
10. Execution of Inventory Command by a Transponder
A transponder returns a response to the reader/writer when its UID is equal to the value that consists of the
mask value and the number of slots. The mask value is sent in the Inventory command, and the number of slots
is determined by the number of times the EOF signal is transmitted.
• Algorithm for execution of processing by a transponder
The following figure shows the algorithm for the execution of processing by a transponder when an Inventory
command is received. The next figure shows the relationship between the UID and the mask value.
• Algorithm for Execution of Processing by a Transponder when Inventory Command
NbS
SN
LSB (value, n)
&
Slot_Frame
: Total number of slots (1 or 16)
: Current slot number
: The “n” least significant bits of value
: Concatenation operator
: SOF or EOF
SN = 0
Nb_slots_flag=1?
YES
NO
NbS = 1
SN_length=0
NbS = 16
SN_length=4
LSB (UID, SN_length + mask length) =
LSB (SN, SN_length) & LSB (mask,
mask length) ?
YES
Response transmission
NO
Wait (Slot_Frame)
Slot_Frame=SOF?
YES
NO
Slot_Frame=EOF?
NO
YES
End of processing
End of processing
SN < NbS-1
NO
YES
SN = SN + 1
End of processing
17
MB89R118
• Comparison of the mask value and the number of slots with the UID
[Inventory command (the side of a reader/writer)]
Padding
Inventory command includes the mask value and mask
length.
The mask value is padded with “0” into the higher bit side
so to make the byte-unit length (a multiple of 8 bits).
000•••
Mask value
(specified by the
Inventory command)
Mask length
If Inventory command is received, the slot
counter is reset to “0”.
Slot
counter
If EOF is received, the increment of the slot
counter is started by the transponder.
Number of
Mask value (no padding)
slots
The value is compared with the lowest bit in
UID of the transponder.
If the value is in accord with the mask value,
the response is returned by the transponder.
Ignored
Compared
Unique Identifier (UID)
MSB
18
[Unique Identifier (the side of a transponder) ]
LSB
MB89R118
11. Anti-Collision Sequence
• Execution of anti-collision sequence
A typical anti-collision sequence that is applied when the number of slots is 16 is executed as follows :
1) The reader/writer sends an Inventory command.
The Nb_slots_flag bit of the request flags is set to “0” to specify the number of slots.
2) In slot 0, transponder 1 transmits its response in the time t1_a from the detection of the rising edge of the
EOF. In this case no collision occurs and the UID of transponder is received and registered by the reader/
writer.
3) The reader/writer sends an EOF signal to switch to the next slot in the time t2_a after the response 1.
4) In slot 1, transponder 2 and transponder 3 transmit their response in the time t1_a from the detection of
the rising edge of the EOF. In this case, the reader/writer cannot recognize the UIDs of the two transponders
because the collision occurs, and the reader/writer remembers that a collision was detected in slot 1.
5) The reader/writer sends an EOF signal to switch to the next slot in the time t2_a after the responses.
6) In slot 2, no transponder transmits a response. The reader/writer does not detect any response, and sends
an EOF signal to switch to the next slot in the time t3_a from the detection of the rising edge of the EOF.
7) In slot 3, transponder 4 and transponder 5 transmit their response in the time t1_a from the detection of
the rising edge of the EOF, and another collision occurs.
8) The reader/writer sends a request (for example, a Read Single Block command, described later) to the
transponder 1, which UID was already correctly received.
9) All transponders detect an SOF signal and exit the anti-collision sequence. In this case, since the request
is addressed to transponder 1 (Addressed Mode), only transponder 1 transmits its response.
10) All transponders are ready to receive another request from the reader/writer. If the Inventory command is
sent again, the anti-collision sequence starts from slot 0.
Note : t1_a, t2_a, t3_a are specified in “12. Timing definitions”.
19
MB89R118
• Example of Anti-Collision Sequence
Slot_Counter
Reader/writer
Slot 0
(1)
SOF
Inventory command
(2)
EOF
t1_a
Status
Slot 2
(5)
EOF
Slot 3
(6)
(7)
EOF
EOF
Response 5
t3_a
Status
No response
Slot_Counter
(8)
Reader/writer
SOF
t1_a
t2_a
Collision
Command
(to Transponder1)
(9)
EOF
Response
(Transponder1)
MB89R118
20
t3_a
t1_a
t2_a
Collision
Response 4
Timing
Status
t1_a
t2_a
No collision
MB89R118
Timing
Response 2
Response 3
Timing
Reader/writer
(4)
EOF
Response 1
MB89R118
Slot_Counter
Slot 1
(3)
MB89R118
12. Timing definitions
(1) Period during which the MB89R118 waits for the start of response transmission after an EOF signal
transmitted from the reader/writer : t1_a
After detection of an EOF signal sent from the reader/writer, MB89R118 must wait for a certain time (t1_a) before
sending a response to the reader/writer. t1_a begins at the rising edge of the EOF pulse, and it is defined as
following. The minimum value is 4320/fc (= 318.6 µs), the nominal value is 4352/fc (= 320.9 µs), and the maximum
value is 4384/fc (=323.3 µs).
Even if the 10% ASK modulated signal from the reader/writer is detected within the time t1_a, the transponder
ignore the signal and wait for further time t1_a before starting to transmit.
(2) Period during which the MB89R118 ignores modulated signals after an EOF signal transmitted from
the reader/writer : tmit
After detection of an EOF signal sent from the reader/writer, MB89R118 must ignore the 10% ASK modulated
signals from the reader/writer for a time (tmit).
tmit begins at the rising edge of the EOF pulse. The minimum value of tmit is defined as 4384/fc (323.3 µs) + tnrt.
In the above expression, tnrt stands for the response time of MB89R118.
(3) Period during which the reader/writer waits before sending a request : t2_a
When the reader/writer has received a response from the transponder to a previous request other than Inventory
and Stay Quiet command, it shall wait a time t2_a before sending a subsequent request. The minimum value of
t2_a is 309.2 µs. It is defined in ISO/IEC 15693-3. And ISO/IEC 18000-3 (Mode 1) .
(4) Period during which the reader/writer waits before sending a request during execution of the Inventory
command : t2inv
While an Inventory command is being executed, the reader/writer sends an EOF signal when it shifts to the next
slot. In this case, the wait time is defined as follows depending on whether transponders return responses :
-
Wait time applied when the reader/writer has received one or more responses : t2invwr
It is defined in ISO/IEC 15693-3. And ISO/IEC 18000-3 (Mode 1) that when the reader/writer has received
one or more responses, the reader/writer must wait until responses from the transponders have been completed (that is, the reader/writer receives an EOF signal or tnrt passes). After that, the reader/writer must
wait until t2_a passes before sending an EOF signal to switch to the next slot.
-
Wait time applied when the reader/writer has not received any responses : t3_a
When the reader/writer has not received any responses from the MB89R118, the reader/writer must wait
until t3_a passes before sending an EOF signal. In this case, t3_a begins at the rising edge of the EOF pulse
that was sent previously. The minimum value of t3_a is defined as 4384/fc (323.3 µs) + tnrt.
• Timing Specifications
Min
Typ
Max
t1_a
4320/fc = 318.6 µs
4352/fc = 320.9 µs
4384/fc = 323.3 µs
tmit
4384/fc(323.3 µs)+ tnrt


t2_a
4192/fc = 309.2 µs


t2invwr
t2_a + tnrt


t3_a
4384/fc(323.3 µs)+ tnrt


21
MB89R118
■ COMMAND LIST
All Mandatory and Optional commands defined by ISO/IEC 15693-3 are supported.
The following Custom commands are supported :
• EAS command
: Using for preventing the theft of goods and goods-monitoring
• Write EAS command
: Writing data to the EAS bit
• Read Multiple Blocks Unlimited command : Enable to read FRAM area of up to 2048 bytes in a lump
• Fast command
: Respond at double speed compared to ISO commands
• Command list
Command
code
22
Command name
Command
Type
Details
“01H”
Inventory
Mandatory Execute the anti-collision sequence and get UID.
“02H”
Stay Quiet
Mandatory Enter the Quiet state
“20H”
Read Single Block
Optional
Read the requested 1 block data in the user area/system area
“21H”
Write Single Block
Optional
Write the requested 1 block data in the user area
“22H”
Lock Block
Optional
Lock (disable to write) the requested 1 block in the user area
“23H”
Read Multiple Blocks
Optional
Read the requested 1 or 2 blocks data in the user area/system
area
“24H”
Write Multiple Blocks
Optional
Write the requested 1 or 2 blocks data in the user area
“25H”
Select
Optional
Enter the select (communication selected) state
“26H”
Reset to Ready
Optional
Enter the ready (communication enabled) state
“27H”
Write AFI
Optional
Write AFI (Application Family Identifier) data into FRAM.
“28H”
Lock AFI
Optional
Lock AFI data (disable to write)
“29H”
Write DSFID
Optional
Write DSFID (Data Storage Format Identifier) data into FRAM
“2AH”
Lock DSFID
Optional
Lock DSFID (Data Storage Format Identifier) data (disable to
write)
“2BH”
Get System Information
Optional
Read the system information value (UID, DSFID, AFI, number
of bytes per block, number of blocks in user area, and IC
information)
“2CH”
Get Multiple Block
Security Status
Optional
Read the block security status stored in system area.
“A0H”
EAS
Custom
When EAS bit is “1”, reply response code 6 times.
“A1H”
Write EAS
Custom
Write EAS data (1 bit). Data “1” validates anti-theft/goodsmonitoring, and data “0” invalidates them.
“A5H”
Read Multiple Blocks
Unlimited
Custom
Read the specified data of up to 256 blocks in the user area/
system area.
“B1H”
Fast Inventory
Custom
Fast response Inventory command
“C0H”
Fast Read Single Block
Custom
Fast response Read Single Block command
“C1H”
Fast Write Single Block
Custom
Fast response Write Single Block command
“C3H”
Fast Read Multiple Blocks
Custom
Fast response Read Multiple Blocks command
“C4H”
Fast Write Multiple Blocks
Custom
Fast response Write Multiple Blocks command
“D1H”
Fast Write EAS
Custom
Fast response Write EAS command
“D5H”
Fast Read Multiple Blocks
Unlimited
Custom
Fast response Read Multiple Blocks Unlimited command
MB89R118
■ COMMAND DESCRIPTION
1. Description of Mandatory Command
1-1. Inventory command
The Inventory command executes the anti-collision sequence.
Even though an error is detected during execution of this command, a response indicating the error is not
returned.
The Inventory_flag (bit 3) must be set to “1”.
When the AFI_flag (bit 5) in the Inventory command frame is set as “1”, the response is returned in the following
cases.
• The AFI value of the transponder is in accord with the optional AFI value.
• The optional AFI value is “00H”.
• Request
[Request from the reader/writer to the transponder]
Command
SOF
Flag
Optional AFI
(Inventory)
8 bits
8 bits (“01H”)
8 bits
Mask length
Mask value
CRC
8 bits
0 to 64 bits
16 bits
EOF
• Response
[Response from the transponder to the reader/writer]
SOF
Flag
DSFID
8 bits (“00H”)
8 bits
UID
CRC
64 bits
16 bits
EOF
1-2. Stay Quiet command
On receiving the Stay Quiet command, the transponder enters the quiet state. The transponder does not return
any responses, including an error indication.
In the quiet state, the transponder does not execute any request for which the Inventory_flag (bit 3) is set to “1”
and executes only a command for which the Address_flag (bit 6) is set to “1”.
The transponder exits the quiet state only in the following cases:
• The transponder enters the power-off state.
• The transponder receives the Select command and enters the select state.
• The transponder receives the Reset to Ready command and enters the ready state.
• Request
[Request from the reader/writer to the transponder]
Command
SOF
Flag
(Stay Quiet)
8 bits
8 bits (“02H”)
UID (necessary)
CRC
64 bits
16 bits
EOF
• Response
[Response from the transponder to the reader/writer]
No response
23
MB89R118
2. Description of Optional Command
2-1. Read Single Block command
On receiving the Read Single Block command, the transponder reads the data stored in the specified singleblock to the reader/writer.
If the Option_flag (bit 7) is “1”, the transponder adds block security status information in the response. If the
Option_flag (bit 7) is “0”, the transponder returns only the data in the specified block to the reader/writer.
• Request
[Request from the reader/writer to the transponder]
Command
UID
SOF
Flag
(Read Single Block)
(Addressed mode)
8 bits
8 bits (“20H”)
Number of
blocks
CRC
8 bits
16 bits
64 bits
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
EOF
Block security status (option)
Data
CRC
8 bits
64 bits
16 bits
8 bits (“00H”)
EOF
2-2. Write Single Block command
On receiving the Write Single Block command, the transponder writes the single-block data included in the
request to the specified block.
The transponder performs verification after writing and returns an error code if the writing has failed.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the write operation
starting after <t1nom + a multiple of 4096/fc (302.1 µs)> with total tolerance of ± 32/fc (2.4 µs) and latest within
20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/writer and upon such
reception still return its response <t1nom : typical 320.9 µs> (However, if an EOF is not sent within 38 ms, the
time-out occurs and the transponder can receive another command).
• Request
[Request from the reader/writer to the transponder]
Command
UID
SOF
Flag
(Write Single Block)
(Addressed mode)
8 bits
24
8 bits (“21H”)
64 bits
Number
of blocks
Data
CRC
8 bits
64 bits
16 bits
EOF
MB89R118
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
2-3. Lock Block command
On receiving the Lock Block command, the transponder locks (write disable) permanently the data stored in one
specified single-block.
The transponder performs verification after writing and returns an error code if the writing has failed.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the lock operation
starting after <t1nom + a multiple of 4096/fc (302.1 µs)> with total tolerance of ± 32/fc (2.4 µs) and latest within
20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/writer and upon such
reception still return its response. (However, if an EOF is not sent within 38 ms, the time-out occurs and the
transponder can receive another command.)
Once the Lock Block command has been received, data in the locked block cannot be changed by the Write
Single (Multiple) Block (s) command.
• Request
[Request from the reader/writer to the transponder]
Command
UID
SOF
Flag
(Lock Block)
(Addressed mode)
8 bits
8 bits (“22H”)
64 bits
Number of
blocks
CRC
8 bits
16 bits
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
25
MB89R118
2-4. Read Multiple Blocks Command
On receiving the Read Multiple Blocks command, the transponder reads the data stored in the specified successive blocks to the reader/writer.
Up to 2 blocks of data can be read for one request.
If the Option_flag (bit 7) is “1”, the transponder adds block security status information in the response. If the
Option_flag (bit 7) is “0”, the transponder returns only the data in the specified blocks to the reader/writer.
The value of the “number of blocks” field specified in the request is the expected number of blocks minus 1.
Setting the number of blocks to “01H” makes a request to read 2 blocks. Setting the number of blocks to “00H”
makes a request to read 1 block (the request having the same effect as the Read Single Block command).
Note : For execution in the addressed mode, the Read Multiple Blocks command must be run without shutting off
the RF power supply after obtaining the UID, for example, using the Inventory command. No response may
be expected when RF power supply is not stable.
• Request
[Request from the reader/writer to the transponder]
Command
UID
SOF
Flag
(Read Multiple Blocks) (Addressed mode)
8 bits
8 bits (“23H”)
First block
number
Number of
blocks
CRC
8 bits
8 bits
16 bits
64 bits
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
Flag
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
EOF
Block security status (option)
Data
CRC
8 bits
64 bits
16 bits
8 bits (“00H”)
EOF
Repeated as required
2-5. Write Multiple Blocks Command
On receiving the Write Multiple Blocks command, the transponder writes the successive multiple-block data
included in the request to the specified blocks.
Up to 2 blocks of data can be written for one request.
The transponder performs verification after writing and returns an error code if the writing has failed. The number
of blocks specified in the Write Multiple Blocks command is similar to the number of blocks specified in the Read
Multiple Blocks command. The value of the number of blocks field specified in the Write Multiple Blocks command
is obtained by subtracting 1 from the number of the expected blocks to be written.
Setting the number of blocks to “01H” makes a request to write 2 blocks. Setting the number of blocks to “00H”
makes a request to write 1 block (the request having the same effect as the Write Single Block command).
If at least one of the blocks specified by the request is locked, the transponder does not write any data and,
instead, returns an error code.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the write operation
starting after <t1nom + a multiple of 4096/fc (302.1 µs)> with total tolerance of ± 32/fc (2.4 µs) and latest within
26
MB89R118
20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/writer and upon such
reception still return its response (However, if an EOF is not sent within 38 ms, the time-out occurs and the
transponder can receive another command) .
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
8 bits
Command (Write
UID
Multiple Blocks) (Addressed mode)
8 bits (“24H”)
64 bits
First block
number
Number of
blocks
Data
CRC
8 bits
8 bits
64 bits
or
128 bits
16 bits
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
2-6. Select command
Of the transponders that received the Select command, only the transponder whose UID matches the UID
included in the request enters the select state and returns a response.
The other transponders, whose UIDs do not match the UID in the request, enter the ready states without returning
any response. The Select command is used only in addressed mode.
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
Command (Select) UID (necessary)
8 bits (“25H”)
8 bits
64 bits
CRC
EOF
16 bits
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
27
MB89R118
2-7. Reset to Ready command
On receiving the Reset to Ready command, the transponder enters the ready state.
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
Command (Reset to Ready)
8 bits
UID (Addressed mode)
CRC
64 bits
16 bits
8 bits (“26H”)
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
2-8. Write AFI command
On receiving the Write AFI command, the transponder writes the data of AFI to FRAM.
The transponder performs verification after writing and returns an error code if the writing has failed.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the write operation
starting after <t1nom + a multiple of 4096/fc (302.1 µs)> with total tolerance of ± 32/fc (2.4 µs) and latest within
20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/writer and upon such
reception still return its response (However, if an EOF is not sent within 38 ms, the time-out occurs and the
transponder can receive another command) .
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
Command (Write AFI) UID (Addressed mode)
8 bits
8 bits (“27H”)
64 bits
AFI
CRC
8 bits
16 bits
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
28
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
MB89R118
2-9. Lock AFI command
On receiving the Lock AFI command, the transponder locks (write disable) permanently the data of AFI.
The transponder performs verification after writing and returns an error code if the writing has failed.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the lock operation
starting after <t1nom + a multiple of 4096/fc (302.1 µs)> with total tolerance of ±32/fc (2.4 µs) and latest within
20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/writer and upon such
reception still return its response (However, if an EOF is not sent within 38 ms, the time-out occurs and the
transponder can receive another command) .
Once the Lock AFI command has been received, the data of AFI cannot be changed by the Write AFI command.
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
Command (Lock AFI) UID (Addressed mode)
8 bits
8 bits (“28H”)
CRC
64 bits
EOF
16 bits
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
2-10. Write DSFID command
On receiving the Write DSFID command, the transponder writes the data of DSFID to FRAM.
The transponder performs verification after writing and returns an error code if the writing has failed.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the write operation
starting after <t1nom + a multiple of 4096/fc (302.1 µs)> with total tolerance of ± 32/fc (2.4 µs) and latest within
20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/writer and upon such
reception still return its response (However, if an EOF is not sent within 38 ms, the time-out occurs and the
transponder can receive another command) .
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
Command (Write DSFID) UID (Addressed mode)
8 bits
8 bits (“29H”)
64 bits
DSFID
CRC
8 bits
16 bits
EOF
29
MB89R118
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
2-11. Lock DSFID command
On receiving the Lock DSFID command, the transponder locks (write disable) permanently the data of DSFID.
The transponder performs verification after writing and returns an error code if the writing has failed.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the lock operation
starting after <t1nom + a multiple of 4096/fc (302.1 µs)> with total tolerance of ± 32/fc (2.4 µs) and latest within
20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/writer and upon such
reception still return its response (However, if an EOF is not sent within 38 ms, the time-out occurs and the
transponder can receive another command) .
Once the Lock DSFID command has been received, the data of DSFID cannot be changed by the Write DSFID
command.
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
Command (Lock DSFID)
8 bits
UID (Addressed mode)
CRC
64 bits
16 bits
8 bits (“2AH”)
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
30
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
MB89R118
2-12. Get System Information command
On receiving the Get System Information command, the transponder reads the chip information of UID, AFI,
DSFID, and so on to the reader/writer as a response.
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
Command (Get System Information) UID (Addressed mode)
8 bits
8 bits (“2BH”)
64 bits
CRC
EOF
16 bits
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
Information flag
8 bits (“00H”)
8 bits
UID
DSFID
AFI
64 bits
8 bits
8 bits
Memory size IC reference
16 bits
8 bits
EOF
CRC
EOF
16 bits
The followings show the definitions of the Information flag and the memory size information (transponder memory
size information) included in the response of the Get System Information command. However, the size of blocks
and number of blocks in the user area shown in the memory size information about a transponder indicate one
less than the actual value.
• Definition of information flag
Bit
Flag name
State
Description
0
DSFID is not supported or does not exist.
1
DSFID is supported or exists.
0
AFI is not supported or does not exist.
1
AFI is supported or exists.
0
Memory size information is not supported or does not exist.
1
Memory size information is supported or exists.
0
IC reference information is not supported or does not exist.
1
IC reference information is supported or exists.
1
DSFID
2
AFI
3
Memory size
4
IC reference
5
RFU*

6
RFU*

7
RFU*

8
RFU*

Set to “0”
* : Reserved for future use
Note : For MB89R118, set “0FH” (set “1” for bit 1 to bit 4 and set “0” for bit 5 to bit 8) .
31
MB89R118
• Memory size information about a transponder
MSB
LSB
16
14 13
RFU*
9 8
Size of blocks (Number of bytes in 1 block)
1
Number of blocks in
the user area
* : Reserved for future use
Note : The memory size of the MB89R118 which is consisted of 250 blocks (8 bytes per block) in the user area,
the memory size information is hexadecimal “07F9H”.
2-13. Get Multiple Block Security Status Command
On receiving the Get Multiple Block Security Status command, the transponder reads the block security status
stored in a system area to the reader/writer as a response.
Up to 64 blocks of data can be read for one request. The number of blocks specified in this request must be the
value that is 1 block less than the actual number of the blocks whose security status is to be obtained.
The first block number specified in this request must be a multiple of 8.
• Request
[Request from the reader/writer to the transponder]
Command
UID
SOF
Flag
(Get Multiple Block
(Addressed mode)
Security Status)
8 bits
8 bits (“2CH”)
First block
number
Number of
blocks
CRC
8 bits
8 bits
16 bits
64 bits
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
8 bits (“00H”)
32
Block security status
CRC
8 bits
(repeated as required)
16 bits
EOF
EOF
MB89R118
3. Custom Command
The IC manufacturing code is required to use a Custom command. The IC manufacturing code for the MB89R118
is “08H”.
3-1. EAS command
On EAS command reception, the transponder returns the response code “5AH” repeated 6 times after the
specified flag (“00H”) if the EAS bit is “1” or returns no response if the EAS bit is “0”. The EAS command can be
executed only when the transponder is in the ready or select state.
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
Command (EAS)
IC manufacturer code
(necessary)
CRC
8 bits
8 bits (“A0H”)
8 bits (“08H”)
16 bits
EOF
• Response
[Response from the transponder to the reader/writer]
SOF
Flag
Response code
8 bits (“00H”)
CRC
48 bits (6 times repeat of “5AH”)
EOF
16 bits
3-2. Write EAS command
On write EAS command reception, the transponder writes the EAS bit to FRAM.
The transponder performs verification after writing and returns an error code if the writing has failed.
The EAS bit must be set to “00H” to cancel anti-theft or goods-monitoring mode. The bit must be set to “01H” to
set up the goods-monitoring mode as the EAS data.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the write operation
starting after <t1nom + a multiple of 4096/fc (302.1 µs)> with total tolerance of ±32/fc (2.4 µs) and latest within
20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/writer and upon such
reception still return its response (However, if an EOF is not sent within 38 ms, the time-out error occurs and
the transponder can receive another command) .
• Request
[Request from the reader/writer to the transponder]
Command
IC manufacturer
UID
SOF Flag
(Write EAS) code (necessary) (Addressed mode)
8 bits
Data
CRC
64 bits
8 bits (“00H” or “01H”)
16 bits
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
8 bits (“A1H”)
8 bits (“08H”)
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
EOF
33
MB89R118
(2) When Error_flag not set
SOF
Flag
CRC
8 bits (“00H”)
16 bits
EOF
3-3. Read Multiple Blocks Unlimited Command
On receiving the Read Multiple Blocks Unlimited command, the transponder reads the data stored in the specified
successive blocks to the reader/writer as a response.
Up to 256 blocks of data can be read for one request.
If the Option_flag (bit 7) is “1”, the transponder adds block security status information in the response. If the
Option_flag (bit 7) is “0”, the transponder returns only the data in the specified blocks to the reader/writer.
The value of the “number of blocks” field specified in the request is the expected number of blocks minus 1.
Setting the number of blocks to “06H” makes a request to read 7 blocks. Up to “FFH” blocks can be set. (Note
that the maximum number of blocks is changed by setting the leading block number.)
• Request
[Request from the reader/writer to the transponder]
UID
Command
IC manufacturer
First block Number
(Addressed
SOF
Flag
(Read Multiple
number of blocks
code (necessary)
Blocks Unlimited)
mode)
8 bits
8 bits (“A5H”)
8 bits (“08H”)
64 bits
8 bits
8 bits
CRC
EOF
16 bits
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
8 bits (“00H”)
EOF
Block security status(option)
Data
CRC
8 bits
64 bits
16 bits
EOF
Repeated as required
3-4. Fast Inventory Command
The Fast Inventory command is the same as the Inventory Command that executes the anti-collision sequence.
The data rate in the response is twice as defined in ISO/IEC 15693.
Even though an error is detected during execution of this command, a response indicating the error is not
returned.
The Inventory_flag (bit 3) must be set to “1”.
When the AFI_flag (bit 5) in the Inventory command frame is set as “1”, the response is returned in the following
cases.
• The AFI value of the transponder is in accord with the optional AFI value.
• The optional AFI value is “00H”.
34
MB89R118
• Request
[Request from the reader/writer to the transponder]
Command
IC manufacturer
SOF
Flag
(Fast Inventory) code (necessary)
8 bits
8 bits (“B1H”)
8 bits (“08H”)
Optional
AFI
Mask
length
Mask
value
CRC
8 bits
8 bits
0 to 64 bits
16 bits
EOF
• Response
[Response from the transponder to the reader/writer]
SOF
Flag
DSFID
8 bits (“00H”)
8 bits
UID
CRC
64 bits
16 bits
EOF
3-5. Fast Read Single Block Command
The Fast Read Single Block command is the same as the Read Single Block command that reads the data
stored in the specific single-block. The data rate in the response is twice as defined in ISO/IEC 15693.
If the Option_flag (bit 7) is “1”, the transponder adds block security status information in the response. If the
Option_flag (bit 7) is “0”, the transponder returns only the data in the specified block to the reader/writer.
• Request
[Request from the reader/writer to the transponder]
Command
IC manufacturer
UID
Number
SOF
Flag
(Fast Read Single Block) code (necessary) (Addressed mode) of blocks
8 bits
8 bits (“C0H”)
8 bits (“08H”)
64 bits
8 bits
CRC
EOF
16 bits
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
Flag
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
EOF
Block security status(option)
Data
CRC
8 bits
64 bits
16 bits
8 bits (“00H”)
EOF
3-6. Fast Write Single Block Command
The Fast Write Single Block command is the same as the Write Single Block command that writes the singleblock data included in the request. The data rate in the response is twice as defined in ISO/IEC 15693.
The transponder performs verification after writing and returns an error code if the writing has failed.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the write operation
starting after <t1nom + a multiple of 4096/fc (302.1 µs)> with total tolerance of ±32/fc (2.4 µs) and latest within
20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/writer and upon such
reception still return its response <t1nom : typical 320.9 µs> (However, if an EOF is not sent within 38 ms, the
time-out occurs and the transponder can receive another command) .
35
MB89R118
• Request
[Request from the reader/writer to the transponder]
Command (Fast
IC manufacturer UID (Addressed Number
SOF
Flag
Write Single Block) code (necessary)
mode)
of blocks
8 bits
8 bits (“C1H”)
8 bits (“08H”)
64 bits
8 bits
Data
CRC
64 bits
16 bits
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
3-7. Fast Read Multiple Blocks Command
The Fast Read Multiple Blocks command is the same as the Read Multiple Blocks command that reads the data
of the specified successive blocks.
Up to 2 blocks of data can be read for one request. The data rate in the response is twice as defined in ISO/IEC
15693.
If the Option_flag (bit 7) is “1”, the transponder adds block security status information in the response. If the
Option_flag (bit 7) is “0”, the transponder returns only the data in the specified blocks to the reader/writer.
The value of the “number of blocks” field specified in the request is the expected number of blocks minus 1.
Setting the number of blocks to “01H” makes a request to read 2 blocks. Setting the number of blocks to “00H”
makes a request to read 1 block (the request having the same effect as the Fast Read Single Block command).
Note : For execution in the addressed mode, the Fast Read Multiple Blocks command must be run without shutting
off the RF power supply after obtaining the UID, for example, using the Inventory command. No response
may be expected when RF power supply is not stable.
• Request
[Request from the reader/writer to the transponder]
UID
Command
IC manufacturer
(Addressed
SOF
Flag
(Fast Read
code (necessary)
mode)
Multiple Blocks)
8 bits
8 bits (“C3H”)
8 bits (“08H”)
64 bits
First
block
number
Number
of
blocks
CRC
8 bits
8 bits
16 bits
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
36
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
EOF
EOF
MB89R118
(2) When Error_flag not set
SOF
Flag
Block security status(option)
Data
CRC
8 bits
64 bits
16 bits
8 bits (“00H”)
EOF
Repeated as required
3-8. Fast Write Multiple Blocks Command
The Fast Write Multiple Blocks command is the same as the Write Multiple Blocks command that writes the
successive multiple-block data included in the request.
Up to 2 blocks of data can be written for one request. The data rate in the response is twice as defined in ISO/
IEC 15693.
The transponder performs verification after writing and returns an error code if the writing has failed. The number
of blocks specified in the Fast Write Multiple Blocks command is similar to the number of blocks specified in the
Read Multiple Blocks command. The value of the number of blocks field specified in the Fast Write Multiple
Blocks command is obtained by subtracting 1 from the number of the expected blocks to be written.
Setting the number of blocks to “01H” makes a request to write 2 blocks. Setting the number of blocks to “00H”
makes a request to write 1 block (the request having the same effect as the Fast Write Single Block command).
If at least one of the blocks specified by the request is locked, the transponder does not write any data and,
instead, returns an error code.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the write operation
starting after <t1nom + a multiple of 4096/fc (302.1 µs)> with total tolerance of ±32/fc (2.4 µs) and latest within
20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/writer and upon such
reception still returns its response (However, if an EOF is not sent within 38 ms, the time-out occurs and the
transponder can receive another command) .
• Request
[Request from the reader/writer to the transponder]
First
UID
Command
Number
IC manufacturer
(Addressed block
SOF Flag
(Fast Write
of blocks
code
number
mode)
Multiple Blocks)
8 bits
8 bits (“C4H”)
8 bits (“08H”)
64 bits
8 bits
8 bits
Data
CRC
64 bits or
128 bits
16 bits
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
37
MB89R118
3-9. Fast Write EAS Command
The Fast Write EAS command is the same as Write EAS command that writes the EAS bit to FRAM. The data
rate in the response is twice as defined in ISO/IEC 15693.
The transponder performs verification after writing and returns an error code if the writing has failed.
The EAS bit must be set to “00H” to cancel anti-theft or goods-monitoring mode. The bit must be set to “01H” to
set up the goods-monitoring mode.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the write operation
starting after <t1nom + a multiple of 4096/fc (302.1 µs)> with total tolerance of ±32/fc (2.4 µs) and latest within
20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/writer and upon such
reception still return its response (However, if an EOF is not sent within 38 ms, the time-out error occurs and
the transponder can receive another command) .
• Request
[Request from the reader/writer to the transponder]
Command
IC manufacturer
UID
SOF Flag
(Fast Write EAS) code (necessary) (Addressed mode)
8 bits
8 bits (“D1H”)
8 bits (“08H”)
64 bits
Data
CRC
EOF
8 bits (“00H” or “01H”) 16 bits
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
3-10. Fast Read Multiple Blocks Unlimited Command
The Fast Read Multiple Blocks Unlimited command is the same as the Read Multiple Blocks Unlimited command
that reads the data of the specified successive blocks.
Up to 256 blocks of data can be read for one request. The data rate in the response is twice as defined in ISO/
IEC 15693.
If the Option_flag (bit 7) is “1”, the transponder adds block security status information in the response. If the
Option_flag (bit 7) is “0”, the transponder returns only the data in the specified blocks to the reader/writer.
The value of the “number of blocks” field specified in the request is the expected number of blocks minus 1.
Setting the number of blocks to “06H” makes a request to read 7 blocks. Up to “FFH” blocks can be set. (Note
that the maximum number of blocks is changed by setting the leading block number.)
• Request
[Request from the reader/writer to the transponder]
UID
Command
First block Number
IC manufacturer
(Addressed
SOF Flag (Fast Read Multiple
number of blocks
code (necessary)
mode)
Blocks Unlimited)
8 bits
38
8 bits (“D5H”)
8 bits (“08H”)
64 bits
8 bits
8 bits
CRC
16 bits
EOF
MB89R118
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
Flag
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
EOF
Block security status (option)
Data
CRC
8 bits
64 bits
16 bits
8 bits (“00H”)
EOF
Repeated as required
4. Command Execution Time
4-1. Write Multiple Blocks Command Execution Time
The minimum time (processing in the addressed mode) required to complete data writing to all user areas (2000
bytes) of the FRAM and verification with the Write Multiple Blocks command is estimated to be 1.4 seconds.
4-2. Read Multiple Blocks Command Execution Time
The minimum time (processing in the addressed mode) required to complete data reading for all user areas
(2000 bytes) of the FRAM with the Read Multiple Blocks command is estimated to be 1.5 seconds.
In addition, with the Fast Read Multiple Blocks command is estimated to be 1.1 seconds, and with the Fast Read
Multiple Blocks Unlimited command is estimated to be 0.35 seconds.
39
MB89R118
■ STATE TRANSITION DIAGRAM
• Definition of states
Each state of MB89R118 is defined as follows.
• Power-Off the state : In the power-off state, a transponder cannot fulfill the function so that the voltage from
a reader/writer is underpowered.
• Ready state
: In the ready state, the MB89R118 can execute all commands if the Select_flag is
not set.
• Quiet state
: In the quiet state, the MB89R118 can execute the command for which the
Inventory_flag is not set and the Address_flag is set.
• Select state
: In the select state, the MB89R118 can execute the command for which the
Select_flag is set.
As shown in figure below, the MB89R118 moves from one state to another according to the status of power and
by a command.
• State transition diagram
Out of field
Power-off state
Out of field
Out of field
In field
Any other command
where Select_flag is not
set.
Ready state
Reset to Ready command
Reset to Ready command where
Select_flag is set or Select (different UID) .
Select command (UID)
Stay Quiet (UID) command
Select command (UID)
Select state
Quiet state
Stay Quiet (UID) command
Any other command
where Address_flag is set
and where Inventory_flag
is not set.
40
Any other command
MB89R118
■ ABSOLUTE MAXIMUM RATINGS
Parameter
Ratings
Symbol
Min
Max
Unit
Maximum antenna input current
Imax

90
mAp−p
ESD voltage immunity
VESD
±2

kV
Storage temperature
Tstg
− 40
+ 85
°C
Remarks
Human body model
WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current,
temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.
■ RECOMMENDED OPERATING CONDITIONS
Parameter
Value
Symbol
Min
Typ
Max
Unit
Minimum antenna input voltage
VRF

8.7
11.2
Vp−p
Antenna input current
IRF


30
mArms
ASK modulation index
m
10

20
%
t1
6.0

9.44
µs
t2
4.7

t1
µs
t3
0

3.0
µs
Input frequency
Fin
13.553
13.560
13.567
MHz
Operating temperature
Ta
− 20

+ 85
°C
ASK pulse width
Remarks
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
representatives beforehand.
■ ELECTRICAL CHARACTERISTICS
DC characteristics
Parameter
Symbol
Internal power supply voltage
Value
Unit
Min
Typ
Max
VDP3
2.7
3.1
3.6
V
Load modulation resistance
RlSW

1.1

kΩ
Input capacitance*
Cant
22.8
24.0
25.2
pF
Remarks
Voltage between antennas = 2 Vrms
* : Values are controlled by process monitoring in the wafer.
41
MB89R118
■ NOTES ON USING
• Notes on the radio interface
- It is the user’s responsibility to reduce the effects of the electromagnetic waves produced by the reader/writer.
- The user must optimize the shapes of the antenna coils for transponder and reader/writer so that they match
the transmission distance and installation space required for the user’s application.
- If the user intends to access multiple transponders from a reader/writer, the interference between
transponders or between the reader/writer and a transponder may degrade communication performance
(transmission distance and communication time) . Therefore, a user who intends to design a system using
multiple transponders should consider this point.
• FRAM reliability
Up to 1010 writes to the FRAM memory and 10 years of data retention at Ta = 0 °C to + 55 °C are guaranteed.
For the data retention characteristics of the mounting temperature at + 150 °C or higher, refer to “■ SHIPPING
METHOD AND RECOMMENDED ASSEMBLY CONDITIONS”.
• Difference between rating of ISO/IEC 15693 and MB89R118 implementation.
The table comparing rating of ISO/IEC 15693 to method of MB89R118 is shown in following.
Note that the MB89R118 implementation does not support following ratings.
• 100% amplitude shift keying (ASK) modulation method
• 1 out of 256 mode data coding
• 2-subcarrier
• Supports more than 3 blocks for Read/Write Multiple Blocks command
(If “Read/Write Multiple Blocks Unlimited command” of Custom commands is used, enables to support more
than 3 blocks.)
42
MB89R118
• Comparison between ratings of ISO/IEC15693 and specification of MB89R118
Parameter
Details
ISO/IEC15693 method
MB89R118 method
10% ASK modulation method
Correspondence
Correspondence
100% ASK modulation method
Correspondence
Not correspondence
(At using of 10% ASK)
10% to 30%
10% to 20%
1 out of 256
Correspondence
Not correspondence
1 out of 4
Correspondence
Correspondence
1-subcarrier
Correspondence
Correspondence
2-subcarrier
Correspondence
Not correspondence
Inventory command
Correspondence
Correspondence
Stay Quiet command
Correspondence
Correspondence
Read Single Block command
Correspondence
Correspondence
Write Single Block command
Correspondence
Correspondence
Lock Block command
Correspondence
Correspondence
Read Multiple Blocks command
Correspondence
Correspondence
uppermost 2 blocks
Write Multiple Blocks command
Correspondence
Correspondence
uppermost 2 blocks
Select command
Correspondence
Correspondence
Reset to Ready command
Correspondence
Correspondence
Write AFI command
Correspondence
Correspondence
Lock AFI command
Correspondence
Correspondence
Write DSFID command
Correspondence
Correspondence
Lock DSFID command
Correspondence
Correspondence
Get System Information command
Correspondence
Correspondence
Get Multiple Block Security Status
command
Correspondence
Correspondence
Communication method
Range of modulation
rate
Data coding
Subcarrier
Mandatory command
Optional command
43
MB89R118
■ SHIPPING METHOD AND RECOMMENDED ASSEMBLY CONDITIONS
• Shipping method
The following shows shipping method and ordering information for the MB89R118. Please inquire separately
for the details.
Part no.
Wafer thickness
Tip dicing
Shipping method
MB89R118A-DI15
150 µm ± 25.4 µm
Completed
Wafer shipping (Mount gold-plated bump in
antenna terminal etc.)
• Recommended assembly conditions
The MB89R118 is recommended to be mounted in the following condition to maintain the data retention characteristics of the FRAM memory when the chip is mounted.
- Mounting temperature of + 175 °C or lower, and 120 minutes or shorter when applied at high temperature, or
- Mounting temperature of + 200 °C or lower, and 60 seconds or shorter when applied at high temperature
Temperature [ °C]
Temperature [ °C]
+200
+175
+25
44
+25
120
60
Time [min]
Time [s]
MB89R118
MEMO
45
MB89R118
MEMO
46
MB89R118
MEMO
47
FUJITSU MICROELECTRONICS LIMITED
Shinjuku Dai-Ichi Seimei Bldg. 7-1, Nishishinjuku 2-chome, Shinjuku-ku,
Tokyo 163-0722, Japan
Tel: +81-3-5322-3347 Fax: +81-3-5322-3387
http://jp.fujitsu.com/fml/en/
For further information please contact:
North and South America
FUJITSU MICROELECTRONICS AMERICA, INC.
1250 E. Arques Avenue, M/S 333
Sunnyvale, CA 94085-5401, U.S.A.
Tel: +1-408-737-5600 Fax: +1-408-737-5999
http://www.fma.fujitsu.com/
Asia Pacific
FUJITSU MICROELECTRONICS ASIA PTE LTD.
151 Lorong Chuan, #05-08 New Tech Park,
Singapore 556741
Tel: +65-6281-0770 Fax: +65-6281-0220
http://www.fujitsu.com/sg/services/micro/semiconductor/
Europe
FUJITSU MICROELECTRONICS EUROPE GmbH
Pittlerstrasse 47, 63225 Langen,
Germany
Tel: +49-6103-690-0 Fax: +49-6103-690-122
http://emea.fujitsu.com/microelectronics/
FUJITSU MICROELECTRONICS SHANGHAI CO., LTD.
Rm.3102, Bund Center, No.222 Yan An Road(E),
Shanghai 200002, China
Tel: +86-21-6335-1560 Fax: +86-21-6335-1605
http://cn.fujitsu.com/fmc/
Korea
FUJITSU MICROELECTRONICS KOREA LTD.
206 KOSMO TOWER, 1002 Daechi-Dong,
Kangnam-Gu,Seoul 135-280
Korea
Tel: +82-2-3484-7100 Fax: +82-2-3484-7111
http://www.fmk.fujitsu.com/
FUJITSU MICROELECTRONICS PACIFIC ASIA LTD.
10/F., World Commerce Centre, 11 Canton Road
Tsimshatsui, Kowloon
Hong Kong
Tel: +852-2377-0226 Fax: +852-2376-3269
http://cn.fujitsu.com/fmc/tw
All Rights Reserved.
The contents of this document are subject to change without notice.
Customers are advised to consult with sales representatives before ordering.
The information, such as descriptions of function and application circuit examples, in this document are presented solely for the purpose
of reference to show examples of operations and uses of FUJITSU MICROELECTRONICS device; FUJITSU MICROELECTRONICS
does not warrant proper operation of the device with respect to use based on such information. When you develop equipment incorporating the device based on such information, you must assume any responsibility arising out of such use of the information.
FUJITSU MICROELECTRONICS assumes no liability for any damages whatsoever arising out of the use of the information.
Any information in this document, including descriptions of function and schematic diagrams, shall not be construed as license of the use
or exercise of any intellectual property right, such as patent right or copyright, or any other right of FUJITSU MICROELECTRONICS
or any third party or does FUJITSU MICROELECTRONICS warrant non-infringement of any third-party's intellectual property right or
other right by using such information. FUJITSU MICROELECTRONICS assumes no liability for any infringement of the intellectual
property rights or other rights of third parties which would result from the use of information contained herein.
The products described in this document are designed, developed and manufactured as contemplated for general use, including without
limitation, ordinary industrial use, general office use, personal use, and household use, but are not designed, developed and manufactured
as contemplated (1) for use accompanying fatal risks or dangers that, unless extremely high safety is secured, could have a serious effect
to the public, and could lead directly to death, personal injury, severe physical damage or other loss (i.e., nuclear reaction control in
nuclear facility, aircraft flight control, air traffic control, mass transport control, medical life support system, missile launch control in
weapon system), or (2) for use requiring extremely high reliability (i.e., submersible repeater and artificial satellite).
Please note that FUJITSU MICROELECTRONICS will not be liable against you and/or any third party for any claims or damages arising
in connection with above-mentioned uses of the products.
Any semiconductor devices have an inherent chance of failure. You must protect against injury, damage or loss from such failures by
incorporating safety design measures into your facility and equipment such as redundancy, fire protection, and prevention of over-current
levels and other abnormal operating conditions.
Exportation/release of any products described in this document may require necessary procedures in accordance with the regulations of
the Foreign Exchange and Foreign Trade Control Law of Japan and/or US export control laws.
The company names and brand names herein are the trademarks or registered trademarks of their respective owners.
Edited
Strategic Business Development Dept.