MPA300L Series Low Profile 300W Single Output Power Factor Corrected AC/DC Power Supplies Key Features: • 300W Output Power • Universal 90-264V AC Input • PFC to EN61000-3-2 “D” • UL, cUL, TUV Approvals • CE Certified • FCC Class B Emissions • 12V to 55V Outputs • Remote Sense /Remote On/Off • Three Mechanical Options NEW Industrial Power!! Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without ih notice. i Input Parameter Input Voltage Range Input Frequency Input Current, Full Load Inrush Current, Cold Start Leakage Current (Note 1) Power Factor Correction Input Protection Conditions Universal Min. 90 47 Typ. Max. 264 63 90 - 264 VAC 8 110 VAC 17.5 220 VAC 35 240 VAC 1.5 Active, Meets EN61000-3-2 Class D T8A/250V Fuse Units VAC Hz A A mA Output Parameter Output Voltage Adjustment Output Regulation (Note 2) Hold Time Ripple & Noise (20 MHz) (Note 3) Overload Protection Over Voltage Protection Over Temperature Protection Temperature Coefficient Transient Recovery Time (Note 4) Transient Response Deviation Overshoot/Undershoot Turn On Delay Output Short Circuit Conditions Min. Typ. Max. ±5.0 ±1.0 80% Load 20 See Model Selection Guide Hiccup Mode 110 140 >130% of Rated Output Voltage. Recycle AC Input. >+85ºC Ambient with Autorecovery ±0.04 2.5 50% Load Change 5 At Turn On/Off 5.0 120 VAC 1 Continuous With Autorecovery By Trim Pot Units % % mSec % %/ºC mS % % S General Parameter Isolation Voltage Switching Frequency Conditions Input - Output Input - FG (Frame Ground) Primary - Core Fixed Min. 3,000 1,500 1,500 Typ. Max. Units VAC 23 kHz Interface Signals Power Supply On MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Power Good Signal Remote Sense Remote On/Off Bi-Color LED on the PCB, Green for power ON, Orange when protection is enabled or the the unit is inhibited (see remote 0n/0ff) PG on CN3. Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS before the loss of regulation. Will sink 100 mA. V1S + and V1S- on CN3. Compensates for up to a 0.5V line drop. (not on models with current share option) INH on CN3. A TTL low signal inhibits the output Environmental Parameter Operating Temperature Range Output Derating Storage Temperature Range Cooling Operating Humidity Vibration, 5 ~ 50 Hz Conditions Min. Typ. Max. Units Ambient 0 +25 +50 ºC 2.5%/ ºC from +50 ºC to + 70 ºC -20 +85 ºC See Model Selection Guide RH, Non-condensing 90 % Acceleration of ±7.35 m/(S x S) on X, Y and Z axis Reliability Specifications Parameter MTBF Safety Standards EMI Compliance EMS Immunity Compliance Conditions Min. Typ. Max. Units MIL HDBK 217F, 30ºC, Gnd Benign 100 kHours UL 60950; CSA C22.2 No. 60950; TUV EN60950; CB Report (IEC 60950) Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3 EN6100-4-2,3,4,5,6,8,11; EN55024,; CE Marked (LVD) Model Selection Guide Model Number MPA300Lx-12zz MPA300Lx-18zz MPA300Lx-24zz MPA300Lx-36zz MPA300Lx-48zz Output Voltage Output Current (Notes 6, 7, 8) Factory (“U” units) Max. “E” Units Range (Note 5) Min PreSet with 22 CFM Int. Fan 12 VDC 12.0 - 15.0 VDC 25.00A 0.0A 25.00A 18 VDC 16.0 - 21.0 VDC 18.75A 0.0A 18.75A 24 VDC 22.0 - 30.0 VDC 13.64A 0.0A 13.64A 36 VDC 31.0 - 41.0 VDC 9.68A 0.0A 9.68A 48 VDC 42.0 - 55.0 VDC 7.15A 0.0A 7.15A Notes: 1. Models are available with leakage current specified as low as 750 µA. Contact the factory for details. 2. Output regulation includes line & load. 3. Ripple & noise is measured from 10 Hz to 20 MHz. Measurement connection to the unit is made with a 0.1 µF ceramic capacitor & a 22 µF electrolytic capacitor connected in parallel. 4. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%. Ripple & Noise Efficiency 1% p-p 1% p-p 1% p-p 1% p-p 1% p-p 80% 80% 80% 80% 80% (Note 7) 5. The full output range (see table above) is covered in the safety agency certification. Standard models are factory set to the “Preset” voltage. This may be set to other levels within the range without affecting the agency certification. Contact the factory for details. 6. A minimum 1% load is required to maintain load regulation and ripple specifications. 7. Output current is given for the factory preset voltage. For more information, contact the factory. 8. Units will provide peak power of 900W for 500 µS. For units capable of longer durations, contact the factory. Input Connector CN1: U-Chassis (U,A) Howder Terminal Block No. HI-201-39 (3-pin), 9.5 mm center or Mating Molex Part No. 09-91-0500 (5 pin, 3 used) or equivalent. Enclosed with Fan (E) Dinkle Terminal Block No. DT-35-A02W-3 (3-pin). Output Connector CN2: Howder Terminal Block No. HD-121-6P (6-pin) or Mating Molex Part No. 09-91-2000 (14 pin) or equivalent. Output Pin Assignment: Howder Molex Pins 1 ~ 3: V+ Pins 1 ~ 7: V+ Pins 4 ~ 6: V- Pins 8 ~ 14: V- Logic Signal Connector CN3: Mating JST XHP-5 or equivalent (CHYAO SHIUNN JS-2001-05). Fan driver connector (FAN): 12 VDC / 400 mA is available to drive an external fan. Mating JST XHP-2 or equivalent (CHYAO SHIUNN JS-2001-02). Mechanical Dimensions: U-Chassis (U Suffix) Enclosure With Fan (E Suffix) U-Chassis Cover (C Suffix) MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]