MPD MPA300L

MPA300L
Series
Low Profile 300W
Single Output
Power Factor Corrected
AC/DC Power Supplies
Key Features:
• 300W Output Power
• Universal 90-264V AC Input
• PFC to EN61000-3-2 “D”
• UL, cUL, TUV Approvals
• CE Certified
• FCC Class B Emissions
• 12V to 55V Outputs
• Remote Sense /Remote On/Off
• Three Mechanical Options
NEW
Industrial
Power!!
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without
ih
notice.
i
Input
Parameter
Input Voltage Range
Input Frequency
Input Current, Full Load
Inrush Current, Cold Start
Leakage Current (Note 1)
Power Factor Correction
Input Protection
Conditions
Universal
Min.
90
47
Typ.
Max.
264
63
90 - 264 VAC
8
110 VAC
17.5
220 VAC
35
240 VAC
1.5
Active, Meets EN61000-3-2 Class D
T8A/250V Fuse
Units
VAC
Hz
A
A
mA
Output
Parameter
Output Voltage Adjustment
Output Regulation (Note 2)
Hold Time
Ripple & Noise (20 MHz) (Note 3)
Overload Protection
Over Voltage Protection
Over Temperature Protection
Temperature Coefficient
Transient Recovery Time (Note 4)
Transient Response Deviation
Overshoot/Undershoot
Turn On Delay
Output Short Circuit
Conditions
Min.
Typ.
Max.
±5.0
±1.0
80% Load
20
See Model Selection Guide
Hiccup Mode 110
140
>130% of Rated Output Voltage. Recycle AC Input.
>+85ºC Ambient with Autorecovery
±0.04
2.5
50% Load Change
5
At Turn On/Off
5.0
120 VAC
1
Continuous With Autorecovery
By Trim Pot
Units
%
%
mSec
%
%/ºC
mS
%
%
S
General
Parameter
Isolation Voltage
Switching Frequency
Conditions
Input - Output
Input - FG (Frame Ground)
Primary - Core
Fixed
Min.
3,000
1,500
1,500
Typ.
Max.
Units
VAC
23
kHz
Interface Signals
Power Supply On
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Power Good Signal
Remote Sense
Remote On/Off
Bi-Color LED on the PCB, Green for power ON, Orange when
protection is enabled or the the unit is inhibited (see remote 0n/0ff)
PG on CN3. Goes TTL high 100 to 500 mS after regulation. Goes low at
least 1 mS before the loss of regulation. Will sink 100 mA.
V1S + and V1S- on CN3. Compensates for up to a 0.5V line drop. (not
on models with current share option)
INH on CN3. A TTL low signal inhibits the output
Environmental
Parameter
Operating Temperature Range
Output Derating
Storage Temperature Range
Cooling
Operating Humidity
Vibration, 5 ~ 50 Hz
Conditions
Min.
Typ.
Max.
Units
Ambient
0
+25
+50
ºC
2.5%/ ºC from +50 ºC to + 70 ºC
-20
+85
ºC
See Model Selection Guide
RH, Non-condensing
90
%
Acceleration of ±7.35 m/(S x S) on X, Y and Z axis
Reliability Specifications
Parameter
MTBF
Safety Standards
EMI Compliance
EMS Immunity Compliance
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 30ºC, Gnd Benign 100
kHours
UL 60950; CSA C22.2 No. 60950; TUV EN60950; CB Report (IEC 60950)
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3
EN6100-4-2,3,4,5,6,8,11; EN55024,; CE Marked (LVD)
Model Selection Guide
Model
Number
MPA300Lx-12zz
MPA300Lx-18zz
MPA300Lx-24zz
MPA300Lx-36zz
MPA300Lx-48zz
Output Voltage
Output Current (Notes 6, 7, 8)
Factory
(“U” units) Max.
“E” Units
Range (Note 5)
Min
PreSet
with 22 CFM
Int. Fan
12 VDC 12.0 - 15.0 VDC
25.00A
0.0A
25.00A
18 VDC 16.0 - 21.0 VDC
18.75A
0.0A
18.75A
24 VDC 22.0 - 30.0 VDC
13.64A
0.0A
13.64A
36 VDC 31.0 - 41.0 VDC
9.68A
0.0A
9.68A
48 VDC 42.0 - 55.0 VDC
7.15A
0.0A
7.15A
Notes:
1. Models are available with leakage current specified as low
as 750 µA. Contact the factory for details.
2. Output regulation includes line & load.
3. Ripple & noise is measured from 10 Hz to 20 MHz.
Measurement connection to the unit is made with a 0.1
µF ceramic capacitor & a 22 µF electrolytic capacitor connected in parallel.
4. Transient recovery is measured to within a 1% error band
for a load step change of 50% to 100%.
Ripple &
Noise
Efficiency
1% p-p
1% p-p
1% p-p
1% p-p
1% p-p
80%
80%
80%
80%
80%
(Note 7)
5. The full output range (see table above) is covered in the safety agency certification. Standard models are factory set to the “Preset” voltage. This may be set to other levels within
the range without affecting the agency certification. Contact the factory for details.
6. A minimum 1% load is required to maintain load regulation and ripple specifications.
7. Output current is given for the factory preset voltage. For more information, contact the
factory.
8. Units will provide peak power of 900W for 500 µS. For units capable of longer durations,
contact the factory.
Input Connector CN1:
U-Chassis (U,A)
Howder Terminal Block No. HI-201-39 (3-pin), 9.5 mm
center or Mating Molex Part No. 09-91-0500 (5 pin, 3
used) or equivalent.
Enclosed with Fan (E)
Dinkle Terminal Block No. DT-35-A02W-3 (3-pin).
Output Connector CN2:
Howder Terminal Block No. HD-121-6P (6-pin) or
Mating Molex Part No. 09-91-2000 (14 pin) or equivalent.
Output Pin Assignment:
Howder
Molex
Pins 1 ~ 3: V+
Pins 1 ~ 7: V+
Pins 4 ~ 6: V-
Pins 8 ~ 14: V-
Logic Signal Connector CN3:
Mating JST XHP-5 or equivalent (CHYAO SHIUNN JS-2001-05).
Fan driver connector (FAN):
12 VDC / 400 mA is available to drive an external
fan. Mating JST XHP-2 or equivalent (CHYAO
SHIUNN JS-2001-02).
Mechanical Dimensions: U-Chassis (U Suffix)
Enclosure With Fan (E Suffix)
U-Chassis Cover (C Suffix)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]