MPU15B SERIES 15W Desk Top Switching Power Supplies For Medical Equipment. Description: The MPU15B series of AC/DC switching mode power supplies provide 15 Watts of continuous output power and is well-suited for a variety of applications. All supplies are UL 94V-1 min compliant. All models comply with UL/c-UL(UL 60601-1:2ndEdition), TUV/Tmark(EN 60601-1:2ndEdition) and new CE requirements. All units are 100% burned-in and tested. Features: Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz IEC-320-C8 Input Inlet Single Output Energy Star 2.0, Efficiency level V Over Voltage and Over Load protection. Over temperature Detection Class II 3 year warranty Safety Approvals: EN 60601-1 IEC 60601-1 Electrical Characteristics: Sym. Parameter Vin Safety Approvals Input Voltage Range Operate Voltage Range fin Input Frequency Po Output Power Range Vo Output Voltage Range CB Agree to apply for the PSE if order on hand Test Conditions Vin=90 to 264VAC Min. Typ. Max. Unit 100 240 VAC 90 264 VAC 47 63 Hz 0 15 W See rating chart V See rating chart A Io Output Current Range Iil Input Current (Low Line) Io=Full load, Vin=115VAC 0.25 0.33 A Iih Input Current (High Line) Io=Full load, Vin=230VAC 0.17 0.18 A Irl Low Line Inrush Current Io=Full load, 25c, Cool start, Vin=115VAC 18 23 A Irh High Line Inrush Current Io=Full load, 25c, Cool start, Vin=230VAC 38 45 A Eff Efficiency Io=Full Load, Vin=230VAC 85 % 1 % REG-i Line Regulation Io=Full Load REG-o Load Regulation Vin=230VAC 73 0.5 5 % OVP 1 Over Voltage○ Protection 112 132 % OCP 1 Over Current○ Protection 110 150 % Ttr Time of Transient Response 4 mS Thold Hold-Up Time Ts Vp-p Start Up Time Io=Full Load, Vin=110VAC 10 Io=Full Load, Vin=100VAC Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC TC Temperature Coefficient All output No-Load Power Consumption No load, Vin=230VAC The parameter is not subject to production test-verified by design/characterization of integrated controller. 1 Thermal Shutdown○ by Junction Temperature Controller 3 Io=Full Load to Half Load, Vin=100VAC Pno Tjsd 1 16 1 S 0.5 1 % 0.04 %/c 0.3 W 125 c -0.04 0 mS 0.5 0.25 -20 1 When the power system interruption is isolated, the product would re-start after recovering by hand. ○ Environmental : Sym. Parameter T e s t Conditions Min. Typ. Max. Unit 50 70 C Toper Operating Temperature Tstg Storage Temperature -40 85 C Ho Operating Humidity 0 95 % Hr Storage Humidity 0 75 % MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F Pd Derate linearly from 100% load at 50 C to 50% load at 70 C 0 0.1M Hrs MPU15B SERIES 15W Desk Top Switching Power Supplies For Medical Equipment. Safety Specifications: Sym. Vps Parameter Min. Typ. Max. Unit 5656 VDC Vin=230VAC,50HZ B CLASS Vin=120VAC,60HZ B CLASS T e s t Conditions Dielectric Withstanding Voltage for Primary to secondary E N 5 5 0 2 2 EMI requirements for EN55022 EMI requirements for FCC PART-18 FCC Primary to secondary Output Voltage And Current Rating Chart ( Single Output ) : ① * * * * Model Number Output Voltage Output Current Total Regulation Maximum Output Power MPU15B-102 5 ~ 6 VDC 2.60~2.16 A 5% 13W 6 ~ 8 VDC 2.16~1.62 A 5% 13W MPU15B-104 8 ~ 11 VDC 1.87~1.36 A 5% 15W MPU15B-105 11 ~ 13 VDC 1.36~1.15 A 5% 15W MPU15B-106 13 ~ 16 VDC 1.15~0.93 A 5% 15W MPU15B-107 MPU15B-103 16 ~ 21 VDC 0.93~0.71 A 5% 15W MPU15B-108 21 ~ 27 VDC 0.71~0.55 A 3% 15W MPU15B-109 27 ~ 33 VDC 0.55~0.45 A 3% 15W MPU15B-110 33 ~ 36 VDC 0.45~0.41 A 3% 15W Mark " * " means " PSE approval " ① MPU15B-102.103 are required to use AWG#16 / 4FT output cable. MPU15B-105~110 are required to use AWG#18 / 4FT output cable. The regulation and efficiency will be changed by modified output cable. Mechanical Specifications : Note: 1. Dimensions are shown in mm. 2. Weight: 170gs approx. 3. Optional output connector: See page Appendix.