ALLEN-BRADLEY MSR123RT

Safety Relays
Monitoring Safety Relays
Minotaur MSR123RT
Specifications
Standards
EN 954-1, ISO 13849-1, IEC/EN
60204-1, IEC 60947-4-1, IEC
60947-5-1, ANSI B11.19, AS4024.1
Category
Cat. 4 per EN954-1
Approvals
C-Tick, CE marked for all
applicable directives, cULus and BG
Power Supply
24V AC/DC, 115/230V AC
0.8 – 1.1 x rated voltage, 50/60Hz
0.9 – 1.1 x 24V DC
Power Consumption
4W
Safety Inputs
1N.C., 2 N.C., Light Curtain
Input Simultaneity
Infinite
Max. Allowable Input Resistance
240 ohms
Description
Reset
Auto./Manual or Monitored Manual
Outputs
2 N. O. Safety, 1 S.S. PNP Aux.
The Allen-Bradley Guardmaster Minotaur MSR123RT is a safety
monitoring relay that provides two normally open safety contacts
and a solid state auxiliary output for use with interfacing to PLCs.
Output Utilization per IEC
60947-4-1 (Resistive)
AC-1: 8A/250V AC
DC-1: 8A/24V DC
➊ Output Utilization per
IEC 60947-5-1 (Inductive)
A300, AC-15
6A/250V AC, 6A/125V AC
N300, DC-13; 3A/24V DC;
6A/24V DC @ 6 ops/min
Thermal Current (non switching)
See limit curve
Max 10A in one circuit
Reset and output monitoring is determined by the wiring
configuration. Automatic/manual reset can use a jumper or can be
used to check operation of external contactors. Monitored manual
requires the use of a manually operated normally open momentary
switch.
Output, Solid State
20mA @ 24V DC
The MSR123RT has 2 normally open safety rated outputs. The
safety outputs have independent and redundant internal contacts to
help ensure the safety function. The solid state auxiliary output is a
PNP circuit with short circuit protection designed to indicate the
status of the MSR123RT.
The MSR123RT can be connected to either a single or dual channel
safety gate or e-stop, or can be connected to a light curtain that
provides cross fault detection.
Fuses, output external
6A slow blow or 10A quick blow
Min. Switched Current/Voltage
10mA/10V
Contact Material
AgSnO2 + 0.5µAu
Power On Delay
1s
Response Time
15ms
Recovery Time
100ms
Indication LEDs
Green = Power on
Green = K1 Closed
Green = K2 Closed
Impulse Withstand Voltage
2500V
Features
•
•
•
•
•
•
•
•
Category 4 per EN 954-1
Stop category 0
2 Safety contacts N.O.
1 Solid state PNP auxiliary contact
Single/dual channel operation
Cross fault monitoring
Monitored or automatic reset
E-stop, safety gate or light curtain applications
current2 x number of contact paths, (A2)
Contact Current Limit Curve
140
-5°C to +55°C (+23°F to +131°F)
Humidity
90% RH
Enclosure Protection
IP40 (NEMA 1), DIN 0470
Terminal Protection
IP20, DIN 0470
Short Circuit Protection
Solid state outputs
Pollution Degree
2
Conductor Size
0.2-4mm2 (24-12AWG)
Mounting
35mm DIN rail
120
Weight 24V DC
110 and 230V AC
270g (0.353lbs)
350g (0.474lbs)
100
Electrical Life
220V AC/4A/880VA/cosϕ=0.35
220V AC/1.7A/375VA/cosϕ=0.6
30V DC/2A/60W
10V DC/0.01A/0.1W
100,000 operations
500,000 operations
1,000,000 operations
2,000,000 operations
40
Mechanical Life
2,000,000 operations
20
Vibration
10-55Hz, 0.35mm
Shock
10g, 16ms, 100 shocks
80
60
0
0
10
20
30
40
50
Ambient Temperature (°C)
4-32
Operating Temperature
60
➊ See Output Ratings on page 1-29 for details. Consult factory for ratings not
shown.
Safety Relays
Monitoring Safety Relays
Minotaur MSR123RT
Product Selection
Inputs
Safety Outputs
Auxiliary Outputs
1 N.C., 2 N.C. or
Light Curtain
2 N.O.
1 S.S. PNP
Power Supply
Catalogue Number
24V AC/DC
440R-J23106
115V AC
440R-J23104
230V AC
440R-J23103
Dimensions—mm (inches) Block Diagram
87 (3.42)
109.5 (4.31)
A1(+) S11
45
(1.77)
75
(2.95)
S52
S12
Y31 Y32
13
23
13
23
14
24
24
A2(-)
K1
MSR123RT
K2
S21
(PE)
4.5
(0.17)
S22
X5
S33
S34
14
Typical Wiring Diagrams
+24V DC
+
24VDC
-
Safety Gate
L1
Light curtain
Out 1 Out 2
L1 L2 L3
L1 L2 L3
Closed
A1 S11 S12 S52 X5 Y31 13 23
A1 S11 S12 S52 X5 Y31 13 23
K1
MSR123RT
K1
MSR123RT
PE
A2 S21 S22 S34 S33 Y32 14 24
M
K1 K2
Reset
PE
A2 S21 S22 S34 S33 Y32 14 24
K2
N
M
K1
Ground
115/230V Supply, 24V DC Light Curtain,
Monitored Manual Reset, Monitored Output
Single Channel Safety Gate,
Automatic Reset, No Output Monitoring
+24V DC
E-Stop
L1 L2 L3
A1 S11 S12 S52 X5 Y31 13 23
K1
MSR123RT
PE
A2 S21 S22 S34 S33 Y32 14 24
Reset
K1 K2
K2
M
Ground
Dual Channel E-Stop,
Monitored Manual Reset, Monitored Output
4-33