IVO NE216.012AX01

Preset counters electronic
2 presets, totalizer and batch counter
Display LED, 5-digits, programmable
NE216
Features
–– Preset counter with two presets
–– Display 5-digits
–– Totalizer, hour counter
–– Operating mode, start count, scaling factor
programmable
–– Connection: Incremental encoder or digital sensors
–– Step and trailing preset programmable
–– Interface RS485
Technical data - electrical ratings
Voltage supply
22...50 VAC (50/60 Hz)
85...265 VAC (50/60 Hz)
12...30 VDC
Programmable
parameters
Power consumption
5 VA, 5 W
Sensor supply
AC: 24 VDC ±20 % / 100 mA
DC: 9...28 VDC / 100 mA
Operating modes
Sensor logic
Scaling factor
Count mode
Control inputs
Approvals
UL/cUL, CE conform
Display
LED, 7-segment display
Number of digits
5-digits
Technical data - mechanical design
Digit height
7.6 mm
Operating temperature
0...+50 °C
Function
Preset counter
Main counter with 2 presets
Totalizer
Hour counter
Storing temperature
-20...+70 °C
Relative humidity
80 % non-condensing
E-connection
Plug-in screw terminals
Core cross-section
1.5 mm²
Protection DIN EN 60529
IP 65 face with seal
Operation / keypad
Membrane with softkeys
Housing type
Built-in housing
Dimensions W x H x L
48 x 48 x 100 mm
100 mm
Scaling factor
0.0001...9999.99
Count modes
Adding or subtracting
A-B (difference counting)
A+B total (parallel counting)
Up/Down
A 90° B phase evaluation
Counting frequency
3 Hz, 25 Hz, 10 kHz
programmable
Installation depth
Mounting
Clip frame
Operating modes
Step preset, Trailing preset,
Time meter and hour counter
Cutout dimensions
45 x 45 mm (+0.6)
Materials
Housing: Makrolon 6485 (PC)
Keypad: Polyester
Weight approx.
150 g
Data memory
>10 years in EEPROM
Reset
Button, electric or automatic
Outputs electronic
Optocoupler
Outputs relay
Normally open or closed,
programmable
Output holding time
0.01...99.99 s
Interface
RS485
Standard
DIN EN 61010‑1
Protection class II
Overvoltage category II
Pollution degree 2
Emitted interference
DIN EN 61000-6-4
Interference immunity
DIN EN 61000-6-2
1
www.baumerivo.com
30/10/2008
Technical data - electrical ratings
Subject to modification in technic and design. Errors and omissions excepted.
NE216 - LED Preset counter
Preset counters electronic
2 presets, totalizer and batch counter
Display LED, 5-digits, programmable
NE216
Part number
Block circuit diagram
AX01
12
Sensor
supply
+
13
-
Voltage
supply
Voltage supply
1 22...50 VAC
2 85...265 VAC
3 12...30 VDC
-
1
+
2
Totalizer
Signal input
A
7
B
8
Control input
1
9
2
10
Outputs
1 Relay outputs
2 Electronic outputs
A 90° B
T,R- 14
T,R+ 15
Interface
0 Without interface
1 RS485
Output
Main counter
with 2 presets
start count
scaling factor
3
4
5
Operating
time meter
6
P1
P2
Interface
RS485
Trigger level
Input circuit
Accessories
PNP- / NPN- / AC-logic
Input level
Programmable
Adaptor plates (page %S)
Input level Low
0...2 VDC
Z 118.033
Input level High
3...40 VDC
Input resistance
3 kΩ
Relay outputs
Output circuit
Switching voltage max.
250 VAC / 110 VDC
Switching current max.
1A
Switching capacity max.
150 VA / 30 W
Relay responding time
5 ms
Electronical outputs
Output circuit
Optocoupler short-circuit proof
Switching voltage max.
40 V
Switching current max.
25 mA
Residual voltage
<1 V
Adaptor plate for screw mount,
face 60 x 75 mm
Z 118.034
Adaptor plate for clip mount,
face 53.2 x 53.2 mm
Z 118.035
Adaptor plate for clip mount,
face 60 x 75 mm
Connection diagram
Electronic outputs
5
4
3
2
1
RS485 Sensor
supply
6
5
Control
input
4
3
max. 265 V
terminal - terminal /
A
7
Signal
input
2
1
P2
P1
Outputs
- terminal
8
B
9
2
3
0V
+24V
T,R-
T,R+
A
1
Signal
input
P2
P1
Outputs
max. 265 V
terminal - terminal/
15 14 13 12 11 10
Supply voltage
6
7
Supply voltage
RS485 Sensor- Control
supply
input
8
B
9
2
3
0V
+24V
T,R-
T,R+
15 14 13 12 11 10
1
Relay outputs
Subject to modification in technic and design. Errors and omissions excepted.
Comparator inputs
Inputs
- terminal
Dimensions
100
60.8
48
7
1-6
44.7
48
10
2
www.baumerivo.com
30/10/2008
NE216.