NLP70 Series Triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 70 W AC/DC Universal Input Switch Mode Power Supplies • • • • • • • • • 1 Provides up to 10.5 A on either 3.3 V or 5 V 5.5 x 3.0 inch card and 1.26 inch package (1U applications) 3.3 V, 5 V and 12 V triple EN61000-3-2 compliant Overvoltage and short circuit protection EN55022, EN55011 conducted emissions level B EN61000-4-2, -3, -4, -5, -6 immunity compliant Mounting holes as per NLP65 series, easy upgrade Available RoHS compliant The NLP70-9693J is a 70 W (with forced air) universal input ac-dc power supply on a 5.5 x 3 inch card with a maximum component height of 1.26 inches for use in 1U applications. The model has input harmonic current correction making the series ideal for product designs that need to comply with EN61000-3-2 legislation. The NLP70 provides 52.5 W of output power with free air convection cooling which can be boosted to 70 W with 20 CFM of air. The NLP70, with full international safety approval and the CE mark, meets conducted emissions EN55022 level B and has immunity compliance to EN610004-2, -3, -4, -5, -6. The NLP70 series is designed for use in low power data networking, computer and telecom applications using 3.3 V or 5 V logic. The NLP70 can provide the same current on either the 3.3 V or 5 V channel making it ideal for applications using a mixture of 3.3V and 5V logic or for applications in transition from 5 V to 3.3 V logic. 2 YEAR WARRANTY SPECIFICATIONS All specifications are typical at nominal input, full load at 25 °C unless otherwise stated OUTPUT SPECIFICATIONS GENERAL SPECIFICATIONS Total regulation (line and load) 3.3 V and 5 V 12 V Rise time At turn-on Transient response Main output 25% step at 0.1 A/µs ±2.0% ±5.0% 1.0 s, max. 5.0% or 250 mV max. dev., 1 ms max. recovery to 1.0% Temperature coefficient ±0.02%/°C Overvoltage protection Main outputs Short circuit protection Cyclic operation Minimum output current 125%, ±10% Continuous (See Note 6) Universal input Input frequency range 90-264 Vac 47-63 Hz Input surge current (cold start) 120 Vac 230 Vac Safety ground leakage current 120 Vac, 60 Hz 230 Vac, 50 Hz Input current 120 Vac, with PFC 230 Vac, with PFC Input fuse UL/IEC127 EMC CHARACTERISTICS Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity 120 Vac @ 60 Hz 230 Vac @ 50 Hz Efficiency 120 Vac, 65 W Isolation voltage Input/output Input/chassis Switching frequency Fixed EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-5, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3 3000 Vac 1500 Vac 300 g (10.7 oz) MIL-HDBK-217F 150,000 hours min. ENVIRONMENTAL SPECIFICATIONS Thermal performance (See Notes 1, 2, 3, 11) 0.7 mA 1.4 mA 1.05 A rms 0.55 A rms 250 Vac S 3.15 A Level B Level A 70% typical EN60950, VDE0805 IEC950, UL1950 CSA C22.2 No. 950 Weight 17 A max. 32 A max. (10) 16 ms @ 55 W 78 ms @ 55 W 100 kHz, ±5 kHz Approvals and standards (See Notes 8, 9) MTBF INPUT SPECIFICATIONS Input voltage range Hold-up time Operating ambient, 0 °C to +70 °C (See derating curve) Non-operating -40 °C to +85 °C 50 °C to 70 °C ambient, Derate to convection cooled 50% load 0 °C to 50 °C ambient, 52.5 W convection cooled 0 °C to 50 °C ambient, 70 W 20 CFM forced air (See Note 10) Peak (0 °C to +50 °C, 60 s) See table Relative humidity Non-condensing Altitude Operating Non-operating Vibration (See Note 5) 5-500 Hz Shock per MIL-STD-810E 5% to 95% RH 10,000 feet max. 30,000 feet max. 2.4 G rms peak 516.4 Part IV File Name: nlp70.pdf Rev (02): 08 Nov 2005 NLP70 Series Triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 70 W AC/DC Universal Input Switch Mode Power Supplies 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm OUTPUT CURRENT OUTPUT VOLTAGE RIPPLE TYP. (1) AIR (2) PEAK TOTAL (4) (3) REGULATION +5 V (IA) 10.5 A 13 A 14 A 50 mV ±2.0% +3.3 V (IB) 10.5 A 13 A 14 A 50 mV ±2.0% (12) 0.65 A 0.8 A 0.8 A 120 mV ±5.0% +12 V MODEL (6) NUMBER (13,14) NLP70-9693J Notes N 1 10 Conducted and radiated emissions testing were performed using the standard EN55022 set-up with a stand alone NLP70-9693J unit placed on a grounded metal plate with a line choke on the AC input and ground wires (i.e. the wires are looped through an EMI suppression toroid). For system compliance it is usually necessary to install an ‘off-the-shelf’ ac inlet with an integral line filter in the system chassis or to install a line choke on the input wires as close as possible to ac entry point of the system chassis. Please contact the applications group at Artesyn for assistance with EMI compliance. 11 All models require a minimum mounting stand-off of 0.25 inches (6.35 mm) in the end use product. 12 12 V is a floating output and can be referenced negative or positive. 13 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. 14 NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative. 2 3 4 5 6 7 8 9 Free air convection cooling. I5 = 10.5 A max.; I3.3 = 10.5 A max.; I3.3 + I5 < 10.6 A; Po = 52.5 W max. 20 CFM forced air. I3.3 = 13 A max.; I5.5 = 13 A max.; I3.3 + I5 < 15 A; Po = 70 W max. Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total regulation limits. Figure is peak-to-peak for convection power rating. Output noise measurements are made across a 20 MHz bandwidth using a 6 inch twisted pair, terminated with a 10 µF electrolytic capacitor and a 0.1 µF ceramic capacitor. Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz. To maintain stated regulation then: I12 / I(A) ≤ 2 and I(A) ≥ 0.1 A. For optimum reliability, no part of the heatsink should exceed 120 ºC, and no semiconductor case temperature should exceed 130 ºC. CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. INPUT PIN CONNECTIONS J1 Pin 1 AC Line Pin 2 No Pin Pin 3 AC Neutral J2 Pin 1 Safety Ground OUTPUT PIN CONNECTIONS J5 FUNCTION Pin 1 3.3V Pin 2 3.3V Pin 3 Return Pin 4 Return Pin 5 Return Pin 6 5V Pin 7 5V J3 FUNCTION Pin 1 12V Return Pin 2 12V (12) DERATING CURVE Output Power (Watts) 70W 20CFM FORCED AIR COOLING 52.5W NATURAL CONVECTION COOLING 0˚C 10˚C 20˚C 30˚C 40˚C 50˚C 60˚C 35W 26W 70˚C File Name: nlp70.pdf Rev (02): 08 Nov 2005 NLP70 Series Triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 70 W AC/DC Universal Input Switch Mode Power Supplies 3 For the most current data and application support visit www.artesyn.com/powergroup/products.htm Input and output connectors Mating connectors AC (J1) connector type Molex 26-60-4030 type. AC (J1) mating connector type Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp terminals. DC (J3) connector type Molex 26-60-4020 type. DC (J3) mating connector type Molex 09-50-3021 with Molex 2478 phosphor bronze crimp terminals or equivalent. DC (J5) connector type Molex 26-60-4070 type. DC (J5) mating connector type Molex 09-50-3071 with Molex phosphor bronze crimp terminals or equivalent. Note: The input and output connectors are the same as those used on NFS40, NAL40, NAN40, NLP40 and NLP65. Earth (J2) connector type Male 0.250 quick disconnect type. Earth (J2) mating connector type Molex 90028. 5.50 (139.70) 0.225 (5.715) 4.550 (115.57) J1 3 N 1 L J5 7 3.00 (76.20) 2.550 (64.770) 1 T1 J3 C19 2 1 J2 MAXIMUM COMPONENT HEIGHT 1.26 (32.00) TOLERANCE: .xxx ± 0.005" .xx ± 0.02" Mounting Hole Diameter 0.156 (4.00) ALL DIMENSIONS IN INCHES (mm) International Safety Standard Approvals VDE0805/EN60950/IEC950 File No. 10401-3336-0143 Licence No. 117595 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062 Datasheet © Artesyn Technologies® 2005 The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. www.artesyn.com File Name: nlp70.pdf Rev (02): 08 Nov 2005