XPPOWER PDM30US12

AC-DC
30 Watts
xppower.com
PDM30 Series
•
CEC2008 & EISA2007 Compliant ≥9 V
•
Worldwide Medical Approvals
•
4000 VAC Isolation
•
Class II Construction
•
Single Outputs from 5 V to 24 V
•
High Efficiency
•
Operation to +60 °C
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Input Protection
General
•
•
•
•
•
90-264 VAC
47-63 Hz
0.6 A rms max
50 A max at 264 VAC
Fitted with a T2 A/250 VAC fuse in live line
Output
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
•
•
•
•
•
82% typical
4000 VAC Input to Output
70 kHz typical
3 W/Inch3
500 kHrs to MIL-STD-217F
Environmental
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient
•
•
•
•
•
See table
±2% set at 60% load
No mimimum load required
3 s max
2 ms
16 ms minimum at 115 VAC
±1%
See tables
5% max deviation recovering to within 1%
within 500 µs for 50% load change
1% max, 20 MHz BW see note 2
See tables
120-150%
Trip & restart (hiccup mode), auto-recovery
±0.05%/°C
Operating Temperature • 0 °C to +60 °C, derate from 100% load at
+40 °C to 60% load at +60 °C for 5, 9 &
12 V models. Derate from 100% load at
+50 °C to 80% load at +60 °C for 15, 18 &
24 V models
Cooling
• Convection-cooled
Operating Humidity
• 15-95% non-condensing
Storage Temperature
• -20 °C to +85 °C
Operating Altitude
• 3000 m
Vibration
• 5-500 Hz at 3 g for 10 mins on each axis
Shock
• 30 g with 18 ms half sine wave,
3 times on each axis
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
•
•
•
•
•
•
•
•
•
EN55011 Level B conducted & radiated
EN61000-3-2
EN61000-3-3
EN61000-4-2 Level 3, Perf Criteria A
EN61000-4-3 Level 2, Perf Criteria A
EN61000-4-4, Level 3, Perf Criteria A
EN61000-4-5 Level 3, Perf Criteria A
EN61000-4-6 Level 3, Perf Criteria A
EN61000-4-11, 70% UT for 500 ms,
40% UT for 100 ms, <5% UT for 5000 ms
Perf criteria A, B, B
• UL60601-1, EN60601-1, IEC60601-1,
CE Mark
Output
Voltage
5V
9V
12 V
15 V
18 V
24 V
Output
Current
4.00 A
3.00 A
2.50 A
2.00 A
1.65 A
1.25 A
OVP
Range
6.45-7.14
10.5-11.6
14.3-15.8
17.1-18.9
20.9-23.1
25.7-28.4
Regulation
Efficiency
V
V
V
V
V
V
Line(3)
±1%
±1%
±1%
±1%
±1%
±1%
74%
81%
82%
83%
83%
83%
Model
Number
PDM30US05
PDM30US09
PDM30US12
PDM30US15
PDM30US18
PDM30US24
Load(4)
±6%
±4%
±3%
±3%
±2%
±2%
Notes
1.
2.
3.
4.
Initial set accuracy is set at 60% full load.
Add a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor to output for ripple and noise measuring at 20 MHz bandwidth.
Line regulation is measured from 100 VAC to 240 VAC with full load.
Load regulation is measured from 20% to 100% full load (60% ±40% full load).
Mechanical Details
48.00 ±0.80 (1220.0 ±20.0)
2.28
(58.00)
5.2 (132.00)
LED
0.47
(12.00)
1.2
(30.5)
IEC320-C8
Output connector is right angle jack 0.22 x 0.10 x 0.47 (5.5 x 2.5 x 12.0), center postive.
Weight: 210 g (0.46 lbs).
All dimensions in inches (mm).
Derating Curves
15 V, 18 V & 24 V Models
100
100
80
80
Output Power (%)
Output Power (%)
5 V, 9 V & 12 V Models
60
40
20
0
10
20
30
40
50
Ambient Temperature (°C)
60
60
40
20
0
10
20
30
40
50
60
Ambient Temperature (°C)
17-Nov-08
AC-DC
PDM30
Models and Ratings