MEANWELL PPQ

PPQ-1003
100W Quad Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at PFC:67KHz PWM:134KHz(Optional)
2 years warranty
SPECIFICATION
MODEL
OUTPUT
INPUT
PPQ-1003A
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
DC VOLTAGE
3.3V
5V
12V
-5V
3.3V
5V
12V
-12V
RATED CURRENT
10A
10A
2A
0.3A
10A
10A
2A
0.3A
CURRENT RANGE
0 ~ 15A
2 ~ 15A
0.2 ~ 3A
0 ~ 1A
0 ~ 15A
2 ~ 15A
0.2 ~ 3A
0 ~ 1A
RATED POWER
108.5W
RIPPLE & NOISE (max.) Note.2 100mVp-p
100mVp-p
150mVp-p
100mVp-p
100mVp-p
100mVp-p
150mVp-p
120mVp-p
VOLTAGE ADJ. RANGE
4.75 ~ 5.5V
3.0%
-----6.0%
-----6.0%
3.14 ~ 3.63V
3.0%
4.75 ~ 5.5V
3.0%
-----6.0%
-----6.0%
LINE REGULATION
1.0%
1.0%
2.0%
1.0%
1.0%
1.0%
2.0%
1.0%
LOAD REGULATION
2.0%
2.0%
6.0%
1.0%
2.0%
2.0%
6.0%
1.0%
SETUP, RISE TIME
800ms, 50ms at full load
HOLD UP TIME (Typ.)
18ms at full load
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC
EFFICIENCY (Typ.)
72%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.65A/115VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
(Note 4)
OTHERS
127 ~370VDC
PF>0.98/115VAC at full load
0.85A/230VAC
COLD START 40A
<1mA /240VAC
105% ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
CH1: 3.6 ~ 4.3V
CH2: 5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
MTBF
150.6K hrs min. MIL-HDBK-217F (25
177.8*107.95*40mm (L*W*H)
0.62Kg; 24pcs/15.5Kg/1.34CUFT
DIMENSION
PACKING
NOTE
110.6W
3.14 ~ 3.63V
VOLTAGE TOLERANCE Note.3 3.0%
LEAKAGE CURRENT
EMC
PPQ-1003B
OUTPUT NUMBER
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Heat Sink HS1,HS2 can not be shorted.
File Name:PPQ-1003-SPEC 2012-02-21
PPQ-1003
100W Quad Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at PFC:67KHz PWM:134KHz(Optional)
2 years warranty
SPECIFICATION
MODEL
OUTPUT
INPUT
PPQ-1003C
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
DC VOLTAGE
3.3V
5V
15V
-15V
3.3V
5V
12V
24V
RATED CURRENT
10A
10A
1.5A
0.3A
10A
10A
2A
0.3A
CURRENT RANGE
0 ~ 15A
2 ~ 15A
0.2 ~ 3A
0 ~ 1A
0 ~ 15A
2 ~ 15A
0.2 ~ 3A
0 ~ 1A
RATED POWER
110W
RIPPLE & NOISE (max.) Note.2 100mVp-p
100mVp-p
180mVp-p
150mVp-p
100mVp-p
100mVp-p
150mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
4.75 ~ 5.5V
3.0%
-----+10,-5%
-----6.0%
3.14 ~ 3.63V
3.0%
4.75 ~ 5.5V
3.0%
-----6.0%
-----6.0%
LINE REGULATION
1.0%
1.0%
2.0%
1.0%
1.0%
1.0%
2.0%
1.0%
LOAD REGULATION
2.0%
2.0%
6.0%
1.0%
2.0%
2.0%
6.0%
1.0%
SETUP, RISE TIME
800ms, 50ms at full load
HOLD UP TIME (Typ.)
18ms at full load
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC
EFFICIENCY (Typ.)
72%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.65A/115VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
(Note 4)
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
114.2W
3.14 ~ 3.63V
VOLTAGE TOLERANCE Note.3 3.0%
LEAKAGE CURRENT
EMC
PPQ-1003D
OUTPUT NUMBER
127 ~370VDC
PF>0.98/115VAC at full load
0.85A/230VAC
COLD START 40A
<1mA /240VAC
105% ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
CH1: 3.6 ~ 4.3V
CH2: 5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
150.6K hrs min. MIL-HDBK-217F (25
177.8*107.95*40mm (L*W*H)
0.62Kg; 24pcs/15.5Kg/1.34CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Heat Sink HS1,HS2 can not be shorted.
File Name:PPQ-1003-SPEC 2012-02-21
PPQ-1003
100W Quad Output with PFC Function
Mechanical Specification
series
Unit:mm
177.8
165.1
6.35
6.35
+3.3V ADJ
95.25
107.95
CN3
1
2
3
4
5
6
7
8
1
2
3
4
5
CN2
AC FUSE
F4A/250V
Pin No.
1
2
3
Assignment
AC/L
No Pin
AC/N
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
DC Output Connector (CN2) : JST B5P-VH or equivalent
FS1
1 2 3 CN1
FG
AC Input Connector (CN1) : JST B3P-VH or equivalent
HS1
HS2
+5V ADJ
4- 3.96
Pin No.
1,2,3
4
5
Assignment
V2
V3
V4
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
DC Output Connector (CN3) : JST B8P-VH or equivalent
40
Pin No.
1~3
4~8
Assignment
V1
COM
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
3 max.
HS1,HS2 can not be shorted
Block Diagram
RECTIFIERS
&
FILTER
EMI FILTER
&
RECTIFIERS
I/P
FG
PFC
CIRCUIT
POWER
SWITCHING
ACTIVE
START
CIRCUIT
PWM & PFC
CONTROL
V4
REGULATOR
RECTIFIERS
&
FILTER
MA
&
CONTROL
RECTIFIERS
&
FILTER
PFC fosc : 67KHz
PWM fosc : 134KHz
(Option)
V3
RECTIFIERS
&
FILTER
+3.3V
+5V
COM
DETECTION
CIRCUT
O.V.P.
Derating Curve
Output Derating VS Input Voltage
17CFM Forced Air Cooling(10cm)
100
100
90
80
Natural convection Cooling
80
70
70
LOAD (%)
LOAD (%)
60
40
20
-10
-10
0
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60 (HORIZONTAL)
60
50
40
90
100
115
135
155
230
264
INPUT VOLTAGE (V) 60Hz
File Name:PPQ-1003-SPEC 2012-02-21