PPQ-1003 100W Quad Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at PFC:67KHz PWM:134KHz(Optional) 2 years warranty SPECIFICATION MODEL OUTPUT INPUT PPQ-1003A CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 3.3V 5V 12V -5V 3.3V 5V 12V -12V RATED CURRENT 10A 10A 2A 0.3A 10A 10A 2A 0.3A CURRENT RANGE 0 ~ 15A 2 ~ 15A 0.2 ~ 3A 0 ~ 1A 0 ~ 15A 2 ~ 15A 0.2 ~ 3A 0 ~ 1A RATED POWER 108.5W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 120mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.5V 3.0% -----6.0% -----6.0% 3.14 ~ 3.63V 3.0% 4.75 ~ 5.5V 3.0% -----6.0% -----6.0% LINE REGULATION 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% LOAD REGULATION 2.0% 2.0% 6.0% 1.0% 2.0% 2.0% 6.0% 1.0% SETUP, RISE TIME 800ms, 50ms at full load HOLD UP TIME (Typ.) 18ms at full load VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 72% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.65A/115VAC OVER LOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE (Note 4) OTHERS 127 ~370VDC PF>0.98/115VAC at full load 0.85A/230VAC COLD START 40A <1mA /240VAC 105% ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed CH1: 3.6 ~ 4.3V CH2: 5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +60 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE EMC EMISSION I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A MTBF 150.6K hrs min. MIL-HDBK-217F (25 177.8*107.95*40mm (L*W*H) 0.62Kg; 24pcs/15.5Kg/1.34CUFT DIMENSION PACKING NOTE 110.6W 3.14 ~ 3.63V VOLTAGE TOLERANCE Note.3 3.0% LEAKAGE CURRENT EMC PPQ-1003B OUTPUT NUMBER ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Heat Sink HS1,HS2 can not be shorted. File Name:PPQ-1003-SPEC 2012-02-21 PPQ-1003 100W Quad Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections:Short circuit/Over load/Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at PFC:67KHz PWM:134KHz(Optional) 2 years warranty SPECIFICATION MODEL OUTPUT INPUT PPQ-1003C CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 3.3V 5V 15V -15V 3.3V 5V 12V 24V RATED CURRENT 10A 10A 1.5A 0.3A 10A 10A 2A 0.3A CURRENT RANGE 0 ~ 15A 2 ~ 15A 0.2 ~ 3A 0 ~ 1A 0 ~ 15A 2 ~ 15A 0.2 ~ 3A 0 ~ 1A RATED POWER 110W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 180mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.5V 3.0% -----+10,-5% -----6.0% 3.14 ~ 3.63V 3.0% 4.75 ~ 5.5V 3.0% -----6.0% -----6.0% LINE REGULATION 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% LOAD REGULATION 2.0% 2.0% 6.0% 1.0% 2.0% 2.0% 6.0% 1.0% SETUP, RISE TIME 800ms, 50ms at full load HOLD UP TIME (Typ.) 18ms at full load VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 72% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.65A/115VAC OVER LOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE (Note 4) ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE 114.2W 3.14 ~ 3.63V VOLTAGE TOLERANCE Note.3 3.0% LEAKAGE CURRENT EMC PPQ-1003D OUTPUT NUMBER 127 ~370VDC PF>0.98/115VAC at full load 0.85A/230VAC COLD START 40A <1mA /240VAC 105% ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed CH1: 3.6 ~ 4.3V CH2: 5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +60 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A 150.6K hrs min. MIL-HDBK-217F (25 177.8*107.95*40mm (L*W*H) 0.62Kg; 24pcs/15.5Kg/1.34CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Heat Sink HS1,HS2 can not be shorted. File Name:PPQ-1003-SPEC 2012-02-21 PPQ-1003 100W Quad Output with PFC Function Mechanical Specification series Unit:mm 177.8 165.1 6.35 6.35 +3.3V ADJ 95.25 107.95 CN3 1 2 3 4 5 6 7 8 1 2 3 4 5 CN2 AC FUSE F4A/250V Pin No. 1 2 3 Assignment AC/L No Pin AC/N Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent DC Output Connector (CN2) : JST B5P-VH or equivalent FS1 1 2 3 CN1 FG AC Input Connector (CN1) : JST B3P-VH or equivalent HS1 HS2 +5V ADJ 4- 3.96 Pin No. 1,2,3 4 5 Assignment V2 V3 V4 Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent DC Output Connector (CN3) : JST B8P-VH or equivalent 40 Pin No. 1~3 4~8 Assignment V1 COM Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent 3 max. HS1,HS2 can not be shorted Block Diagram RECTIFIERS & FILTER EMI FILTER & RECTIFIERS I/P FG PFC CIRCUIT POWER SWITCHING ACTIVE START CIRCUIT PWM & PFC CONTROL V4 REGULATOR RECTIFIERS & FILTER MA & CONTROL RECTIFIERS & FILTER PFC fosc : 67KHz PWM fosc : 134KHz (Option) V3 RECTIFIERS & FILTER +3.3V +5V COM DETECTION CIRCUT O.V.P. Derating Curve Output Derating VS Input Voltage 17CFM Forced Air Cooling(10cm) 100 100 90 80 Natural convection Cooling 80 70 70 LOAD (%) LOAD (%) 60 40 20 -10 -10 0 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 (HORIZONTAL) 60 50 40 90 100 115 135 155 230 264 INPUT VOLTAGE (V) 60Hz File Name:PPQ-1003-SPEC 2012-02-21