AC-DC 250 Watts xppower.com SDR Series • 3.2” x 5” Footprint • Fits 1U Applications • Low Leakage Current Option • Up to 600 W Peak Power • Single & Dual Outputs • Top Fan & Convection-cooled Versions • Output Voltages from 5 V to 60 V Specification Input Input Voltage • 90-132 VAC/180-264 VAC, auto ranging Input Frequency • 47-63 Hz Input Current • 6 A at 115 VAC, 3 A at 230 VAC Inrush Current • Max 70 A at 230 VAC, 35 A at 115 VAC, cold start Power Factor • To EN61000-3-2 Class A Earth Leakage Current • <1.5 mA at 264 VAC, option ‘-L’ 500 µA leakage current Input Protection • Fitted with a T6.3 A/250 V fuse on dual output models, T8 A/250 V fuse on single output models General Efficiency Isolation Switching Frequency Power Density Signals MTBF Output Output Voltage Output Voltage Trim • See tables • ±5% on V1 (V2 of dual output models will track by same % of adjustment) Initial Set Accuracy • ±1% Minimum Load • 1% on single output models, 10% on dual output models Start Up Delay • 1.5 s max at 120 VAC Start Up Rise Time • 50 ms typical Hold Up Time • 20 ms min at 80% of full load Line Regulation • ±0.5% Load Regulation • ±1% 1-100% load for single outputs ±3% V1, ±7% V2 for dual outputs (except 0312 & 0512 models, ±10% regulation on V2) Over/Undershoot • 5% max Transient Response • 5% max deviation, recovery to within 1% in 500 µs for a 50% load change Ripple & Noise • 1% pk-pk, see note 3 Overvoltage Protection • 105-130% Vnom on output V1, recyle input to reset Overtemperature • Measured internally with auto recovery Protection Overload Protection • 110-140% Short Circuit Protection • Trip & restart (Hiccup mode), auto recovery Remote On/Off • Requires a low signal to inhibit output Fan Supply • 12 VDC, 300 mA, not available on ‘-F’ version with built-in fan • Single output models: 3.3 V & 5 V models 70%, 12 V models 80%, all other models >83% at 230 V & full load. Dual output models: >70% at 230 V & full load • 3000 VAC Input to Output 1500 VAC Input to Ground 100 VDC Output to Ground • 30 kHz typical • 10.4 W/in3 • Power Good goes Hi 100-500 ms after output is in regulation and goes Lo at least 1 ms before loss of regulation • 100 kHrs to MIL-HDBK-217F Environmental Operating Temperature • 0 °C to +70 °C, derate at 2.5%/ °C from +50 °C to +70 °C for single output & forced air cooled dual output models. For convection cooled dual output models, see note 7. Storage Temperature • -20 °C to +85 °C Operating Humidity • 5-90%, non-condensing Storage Humidity • 5-90%, non-condensing Cooling • ‘-F’ version has built-in fan, others require 16 CFM to meet forced air ratings Operating Altitude • 3000 m Vibration • 5-50 Hz, acceleration 7.35 m/s2 on X, Y and Z axis EMC & Safety Emissions Harmonic Currents ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions Safety Approvals • FCC Part 15 & EN55022 Level B conducted • EN61000-3-2, EN61000-3-3 • EN61000-4-2, level 3 Perf Criteria A • EN61000-4-3, 3 V/m Perf Criteria A • EN61000-4-4, level 2 Perf Criteria A • EN61000-4-5, level 3 Perf Criteria A • EN61000-4-6, 3V Perf Criteria A • EN61000-4-11 70% UT for 10 ms, 40% UT for 100 ms, <5% UT for 5000 ms Perf Criteria A, B, B • UL60950-1, CSA C22.2 No. 950, EN60950-1:2001, CE Mark LVD Output Voltage 5V 9V 12 V 15 V 18 V 24 V 28 V 36 V 48 V 54 V 60 V Output Power 200 W 225 W 250 W 250 W 250 W 250 W 250 W 250 W 250 W 250 W 250 W Output Voltage V1 : +3.3 V V2 : +12.0 V V1 : +3.3 V V2 : +24.0 V V1 : +5.0 V V2 : +12.0 V V1 : +5.0 V V2 : +24.0 V V1 : +5.0 V V2 : +48.0 V V1 : +12.0 V V2 : +24.0 V Output Power 200 W 200 W 200 W 200 W 200 W 250 W Output Current Nominal 40.00 A 25.00 A 20.83 A 16.70 A 13.89 A 10.42 A 8.93 A 6.94 A 5.21 A 4.63 A 4.17 A Peak(2) 120.00 A 66.67 A 50.00 A 40.00 A 33.30 A 25.00 A 21.43 A 16.67 A 12.50 A 11.10 A 10.00 A Output Current Nominal 24 A 12 A 24 A 6A 24 A 12 A 24 A 6A 24 A 3A 12 A 6A Peak(2) 28.8 A 14.4 A 28.8 A 7.2 A 28.8 A 14.4 A 28.8 A 7.2 A 28.8 A 3.6 A 14.4 A 7.2 A Ripple & Noise Pk-Pk(3) 50 mV 90 mV 120 mV 150 mV 180 mV 240 mV 280 mV 360 mV 480 mV 540 mV 600 mV Model Number(1,4,5) SDR250AS05-F SDR250AS09-F SDR250AS12-F SDR250AS15-F SDR250AS18-F SDR250AS24-F SDR250AS28-F SDR250AS36-F SDR250AS48-F SDR250AS54-F SDR250AS60-F Ripple & Noise Pk-Pk(3) 50 mV 120 mV 50 mV 240 mV 50 mV 120 mV 50 mV 240 mV 50 mV 480 mV 120 mV 240 mV Model Number(1,4,5) SDR250AD0312-F SDR250AD0324-F SDR250AD0512-F SDR250AD0524-F SDR250AD0548-F SDR250AD1224-F Notes 1. 2. 3. 4. 5. Add suffix ‘L’ to model number for optional 500 µA leakage current. Peak load can be taken for 500 µs. Average power not to exceed max power. Ripple & noise is measured using a 0.1 µF ceramic capacitor in parallel with 22 µF electrolytic and 20 MHz bandwidth. Add suffix ‘D’ for optional output terminal block except the 5 V and 9 V output models which are only available with output terminal blocks. Add suffix ‘E’ for optional input terminal block. Mechanical Details Enclosed with top fan All dimensions are in inches (mm). Weight: 430 g (0.95 lbs) 0.25 (6.35) A A A Mounting hole 7 places M3 x 0.5 0.25 (6.35) 2.00 (50.80) 0.75 (19.05) A 2.25 (57.10) 2.70 (68.58) 0.55 (13.90) 1.66 (42.10) 1.75 (44.52) A A 3.20 (81.28) V1 RTN CN2 CN2 V2 A RTN FG NEUTRAL LINE CN1 V1 CN3 0.32 (8.26) 2.55 (64.77) LED1 RTN RMSW P.G A Molex Part No. 09-91-0500 or equivalent (5 Pin, 3 Used) OPTION ‘E’ Terminal Block M3 Screw 3 Pins 0.25 (6.35) Centre Dual Output Models Single Output Models (5 V & 9 V Models Only Available With Screw Terminals) OPTION ‘D’ RTN V1 RTN RTN V1 V2 V1 5.00 (127.00) Single Output Models Terminal Block M3 Screw 4 Pins 0.25 (6.35) Centre Dual Output Models Terminal Block M4 Screw 3 Pins 0.33 (8.35) Centre Signal connector CN1 mates with JST XHP-3 or equivalent & crimp terminals SXH-002-P0.6. Input: Molex No. 09-91-0500, crimp terminals Molex series 6838. Output: Molex No. 09-91-0600 for 12 V to 60 V single output models, 09-91-0800 for dual output models, crimp terminals Molex series 6838. Terminal block for 5 V to 9 V single output models. AC-DC SDR Series Models and Ratings Output Voltage 5V 9V 12 V 15 V 18 V 24 V 28 V 36 V 48 V 54 V 60 V Forced Air Cooled Output Power Output Current 200 W 40.00 A 225 W 25.00 A 250 W 20.83 A 250 W 16.70 A 250 W 13.89 A 250 W 10.42 A 250 W 9.93 A 250 W 6.94 A 250 W 5.21 A 250 W 4.63 A 250 W 4.17 A Convection-cooled Output Power Output Current 100 W 20.00 A 121 W 13.50 A 135 W 11.23 A 135 W 9.00 A 135 W 7.50 A 135 W 5.63 A 135 W 4.82 A 135 W 3.75 A 135 W 2.81 A 135 W 2.50 A 135 W 2.25 A Peak Current(2) 120.00 A 66.67 A 50.00 A 40.00 A 33.30 A 25.00 A 21.43 A 16.67 A 12.30 A 11.10 A 10.00 A Ripple & Noise Pk-Pk(3) 50 mV 90 mV 120 mV 150 mV 180 mV 240 mV 330 mV 360 mV 480 mV 540 mV 600 mV Model Number(1,4,5,6) SDR250AS05 SDR250AS09 SDR250AS12 SDR250AS15 SDR250AS18 SDR250AS24 SDR250AS28 SDR250AS36 SDR250AS48 SDR250AS54 SDR250AS60 Output Voltage V1 : +3.3 V2 : +12.0 V1 : +3.3 V2 : +24.0 V1 : +5.0 V2 : +12.0 V1 : +5.0 V2 : +24.0 V1 : +5.0 V2 : +48.0 V1 : +12.0 V2 : +24.0 Forced Air Cooled Output Power Output Current 24 A 200 W 12 A 24 A 200 W 6A 24 A 200 W 12 A 24 A 200 W 6A 24 A 200 W 3A 12 A 250 W 6A Convection-cooled Output Power Output Current 12 A 100 W 7A 12 A 100 W 4A 12 A 100 W 7A 12 A 100 W 4A 12 A 100 W 2A 7A 135 W 4A Peak Current(2) 28.8 A 14.4 A 28.8 A 7.2 A 28.8 A 14.4 A 28.8 A 7.2 A 28.8 A 3.6 A 14.4 A 7.2 A Ripple & Noise Pk-Pk(3) 50 mV 120 mV 50 mV 240 mV 50 mV 120 mV 50 mV 240 mV 50 mV 480 mV 120 mV 240 mV Model Number(1,4,5,6,7) V V V V V V V V V V V V SDR250AD0312 SDR250AD0324 SDR250AD0512 SDR250AD0524 SDR250AD0548 SDR250AD1224 Notes 5. Add suffix ‘D’ for optional output terminal block except the 5 V and 9 V output models which are only available with output terminal blocks. 6. Add suffix ‘E’ for optional input terminal block. 7. Operating temperature - 0 ºC to +60 ºC, derate at 5%/ ºC from 50 ºC to 60 ºC for convection cooled dual output models. 1. Add suffix ‘L’ to model number for optional 500 µA leakage current. 2. Peak load can be taken for 500 µs. Average power not to exceed max power. 3. Ripple & noise is measured using a 0.1 µF ceramic capacitor in parallel with 22 µF electrolytic and 20 MHz bandwidth. 4. For optional vented cover add suffix ‘-C’ to model number. Mechanical Details U-Channel All dimensions are in inches (mm). Weight: 400 g (0.88 lbs) 0.25 (6.35) A A 0.75 (19.05) A 1.50 (38.10) 1.75 (44.52) 2.70 (68.58) 0.55 (13.90) A Mounting hole 7 places M3 x 0.5 (Brass) 0.25 (6.35) 2.00 (50.80) A A A Molex Part No. 09-91-0500 or equivalent (5 Pin, 3 Used) OPTION ‘E’ Terminal Block M3 Screw 3 Pins 0.25 (6.35) Centre V1 CN2 CN2 RTN V1 RTN CN1 V2 A 0.32 (8.26) CN3 FG NEUTRAL LINE FAN RETURN REMOTE ON/OFF POWER GOOD 3.20 (81.28) LED1 2.55 (64.77) AC-DC SDR Mechanical Details Dual Output Models Single Output Models (5 V & 9 V Models Only Available With Screw Terminals) OPTION ‘D’ RTN V1 RTN 1.50 (38.10) RTN V1 V2 V1 5.00 (127.00) Single Output Models Terminal Block M3 Screw 4 Pins 0.25 (6.35) Centre Dual Output Models Terminal Block M4 Screw 3 Pins 0.33 (8.35) Centre Signal connector CN1 mates with JST XHP-3 or equivalent & crimp terminals SXH-002-P0.6. Fan connector mates with JST XHP-2 or equivalent & crimp terminals. Input: Molex No. 09-91-0500, crimp terminals Molex series 6838. Output: Molex No. 09-91-0600 for 12 V to 60 V single output models, 09-91-0800 for dual output models, crimp terminals Molex series 6838. Terminal block for 5 V to 9 V single output models. AC-DC SDR Mechanical Details U-Channel with cover (Option ‘-C’) All dimensions are in inches (mm). Weight: 420 g (0.93 lbs) 0.25 (6.35) A A 0.75 (19.05) A 1.66 (42.10) 1.75 (44.52) 2.70 (68.58) 0.55 (13.90) A Mounting hole 7 places M3 x 0.5 0.25 (6.35) 2.00 (50.80) A A Supply 1 B RTN V1 RTN CN2 CN2 V2 A CN1 V1 FG NEUTRAL LINE 0.32 (8.26) CN3 3.20 (81.28) 2.55 (64.77) LED1 FAN RETURN REMOTE ON/OFF POWER GOOD Output OPTION ‘E’ Return Terminal Block Molex Part No. 09-91-0500 or equivalent (5 Pin, 3 Used) Dual Output Models Single Output Models M3 Screw 3 Pins 0.25 (6.35) Centre OPTION ‘D’ V1 CN3 Pin 6 Current Share RTN LOAD Supply 2 V1 RTN RTN V1 Comm V2 V1 Output Single Output Models Terminal Block M3 Screw 4 Pins 0.25 (6.35) Centre Return 5.00 (127.00) Dual Output Models Terminal Block M4 Screw 3 Pins 0.33 (8.35) Centre CN3 Pin 6 Current Share Signal connector CN1 mates with JST XHP-3 or equivalent & crimp terminals SXH-002-P0.6. Fan connector mates with JST XHP-2 or equivalent & crimp terminals. Input: Molex No. 09-91-0500, crimp terminals Molex series 6838. Output: Molex No. 09-91-0600 for 12 V to 60 V single output models, 09-91-0800 for dual output models, crimp terminals Molex series 6838. Terminal block for 5 V to 9 V single output models Output + Supply Application Notes Remote On/Off CN3 Pin 7 Sense + LOAD CL CN3 Pin 6 Current Share CN3 Pin 6 Sense - Output - CD PSU CN1 Pin 1 Return OOD Supply 2 ON CN1 Pin 2 ON/OFF Output Return + Twisted Pair Supply ER GOOD 1 CD Output Return Note: 1. Applying <0.3 V or short between pins 2 and 1 turns the output OFF. 2. Applying >4.5 V or open circuit between pins 2 and 1 turns output ON. CN3 Pin 6 Current Share OFF Power Good +5 V 1K POWER GOOD CN1 Pin 3 DC OK CN1 Pin 1 Return PSU Sink current = 6 mA Source current = 4 mA POWER NOT GOOD CN1 Pin 2 ON/OFF CN1 Pin 1 Return 04-Apr-08