SGX-1505FB “HOCKEY PUCK” SOLID STATE RELAY 10 THRU 40 AMPS 48 TO 380 VRMS FEATURES • Photo isolation • Up to 800V blocking voltage • Both “Zero Voltage” and phase controllable “Random” Switching versions • High surge capability • Built-in snubber • UL, CUR file E43203 • Triac Output Circuitry INPUT Type DC Input 24 VAC 110 VAC 220 VAC Control Voltage Range 3 to 32 VDC 19.2 to 28.8 VAC 85 to 132 VAC 175 to 264 VAC Turn On Voltage 3 VDC Max 19.2 VAC Max. 85 VAC Max. 175 VAC Max. 1 VDC Min. 2 VAC Min. 10 VAC Min. 10 VAC Min. 25 mA 15 mA 15 mA 15 mA -32 VDC - - - Turn Off Voltage Max. Input Current Max. Reverse Voltage OUTPUT Type Output Voltage Range Blocking Voltage Max. Leakage Current (off) 240 380 48 to 264 VAC 48 to 380 VAC 48 to 530 VAC 600 Vpk 800 Vpk 1200 Vpk 5 mA 5 mA Max. Voltage Drop (at rated current) Random Turn On (DC input): 1 ms Zero Cross Turn On (DC input): 1/2 cycles + 1 ms AC Input: 20 ms Max. Turn-Off Time DC Input: 1/2 cycle + 1 ms AC Input: 40 ms Min. Power Factor 5 mA 1.5 VRMS Max. Turn-On Time Min. Off-State (dv/dt) 480 200 V/us 0.5 GENERAL Dielectric Strength Insulation Resistance Max. Capacitance (in/out) Ambient Temperature 4000 Vrms min. (at 50/60 Hz, 1 min.) 1000 Min. (at 500 VDC) 8 pf Operating: -30°C (-22°F) to 80°C (176°F) Storage: -30°C (122°F) to 100°C (212°F) Panel Mount Termination Weight Screw 88g 1/13/06W SGX-1505FB RELAY ORDERING DATA SGX-1505FB D 240 A INPUT VOLTAGE OPERATING VOLTAGE RANGE LOAD TYPE D: 3 TO 32 Vdc 24A: 24 Vac* 110A: 110 Vac* 220A: 220 Vac* 240:48 TO 264 Vac 380: 48 to 380 Vac A: AC LOAD MODEL 40 Z LOAD CURRENT 10: 15: 20: 25: 40: ZERO CROSS OR RANDOM 10A 15A 20A 25A 40A Z: Zero cross turn on P: Random turn on L LED INDICATOR NIL: no LED L: with LED (not for AC input type) *UL pending MECHANICAL DATA Outline Dimensions 2-M.118 [M3.0] 1.870 [47.5] 2-M.157 [M4.0] 2-M.157 [M4.0] .902Max [22.9] .795Max [20.2] Wiring Diagram Load power supply Load 1.870 [47.5] 1 4 1.00 [25.4] .449 [11.4] 1.098 [27.9] 3 1 1.799 Max [45.7] LOAD 2 2 2-Ø.177 [Ø4.5] -4 1.743 [44.26] INPUT 3+ .323 [8.2] 2.299 Max [58.4] input control signal Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010" INSTALLATION PRECAUTIONS 1. When mounting the relays side by side, provide a space equivalent to the width of a single SSR between two adjacent SSRs. Otherwise, reduce the load current flow to 1/2 to 1/3 of the rated current. 1. Before connecting a load that generates a high surge current, such as a lamp load to the SSR, make sure that the SSR can withstand the surge current of the load. 2. 2. When mounting relays on heat sink surface, first apply a heat conductive grease to the metal back surface of the SSR. Press the SSR firmly onto the heat sink to ensure a good seal. Screw the SSR down to the heat sink. The product data sheet shows the non-repetitive peak value of the surge current that flows through the SSR. Normally, use 1/2 of the non-repetitive peak surge current as the standard value. If a surge current exceeding that value is expected, connect a quick-blowing fuse to protect the SSR. 3. Next, wire the screw terminals and securely tighten the screws. 1/13/06W SGX-1505FB CHARACTERISTIC CURVES 10 Amp Model 20 Amp Model 15 Amp Model 25 Amp Model 40 Amp Model F=50Hz 1/13/06W