ROHM SML

Data Sheet
SML-51 Series
1608
(0603)
1.6×0.8mm
(t=0.55mm)
Features
・Original device technology enables high brightness
and high reliability
・High reliability due to the wide operation
Color
Type
temperature(-40℃ to +100℃)
(SML-512(A) Series)
V
U
C
D
W
M
P
B
Specifications
Absolute Maximum Ratings (Ta=25℃)
Electrical and Optical Characteristics (Ta=25℃)
Chip
Emitting Power
Forward Voltage VF Reverse Current IR Dominant Wavelength λD Luminous Intensity IV
Forward Peak Forward Reverse Operating
Storage
Structure Color Dissipation Current
Current
Voltage Temperature Temperature
Max.
Min. Typ.
Min.*3 Typ. Max.*3
PD(mW) IF(mA) IFP(mA) VR(V)
Topr(℃)
Tstg(℃) Typ.(V) IF(mA) (μA) VR(V) (nm) (nm) (nm) IF(mA) (mcd) (mcd) IF(mA)
Part No.
■ SML-512VW(A)
■ SML-512VW
75
30
2
100*
5
-40 to +100
-40 to +100
10
35.5
56
22
63
626
630
636
619
624
629
615
620
625
14
40
600
603
606
71
112
5
Red
■ SML-512UW
■ SML-511UW
62
25
■ SML-512CW(A)
■ SML-512DW
AIGaInP on Orange
GaAs
■ SML-511DW
■ SML-512WW
75
30
Yellowish
Green
■ SML-512PW(A)
Green
InGaN on
SiC
■ SML512BC5T
-30 to +85
100
4
2.0
5
-40 to +100
-40 to +100
10
5
4
25
60*1
4
-30 to +85
-40 to +85
100
75
30
100*2
5
-40 to +100
-40 to +100
10
60*1
4
-30 to +85
100*2
66
606
609
605
608
587
590
593
20
5
36
100
14
40
36
63
20
22
-40 to +85
40
25
65
603
602
4
567
570
575
557
560
563
464
470
476
14
100
2.1
5
5
-40 to +100
Blue
-40 to +85
62
62
■ SML-512MW
100*2
4
20
Yellow
■ SML-511WW
60*1
14
-40 to +100
5.6
20
2.9
5
5
16
5
*1:Duty1/5, 200Hz / *2:Duty1/10, 1kHz / *3:Reference
Dimensions
Recommended Solder Pattern Viewing Angle
SML-51 Series
1.6
(deg)
SCANNING ANGLE
Directivity
(deg)
(deg)
SCANNING ANGLE
Directivity
(deg)
1.2
0.8
X
20°
Y
10°
0°
10°
20°
0.8
30°
X’
0.8
0.55
80°
80°
0.85
0.18
0.8
X
20°
Y
10°
0°
10°
70°
80°
50
0
90°
100
50
RELATIVE INTENSITY (%)
RELATIVE
INTENSITY (%)
SCANNING ANGLE (deg)
SCANNING
ANGLE (deg)
X’
20°
70°
80°
80°
(unit : mm)
1/2
50
0
50
10°
20°
30°
40°
50°
90°
100
RELATIVE INTENSITY (%)
RELATIVE
INTENSITY (%)
60°
60°
60°
70°
0°
50°
50°
60°
10°
30°
40°
40°
50°
90°
100
20°
Y’
30°
40°
© 2010 ROHM Co., Ltd. All rights reserved.
60°
SML512BC5T
Terminal
www.rohm.com
40°
50°
90°
100
90°
100
50
(deg)
SCANNING ANGLE
Directivity
(deg)
30°
Tolerance : ±0.1
(unit : mm)
30°
80°
RELATIVE INTENSITY (%)
1.0
20°
70°
70°
70°
RELATIVE INTENSITY (%)
Cathode mark
10°
60°
60°
60°
0
0°
50°
50°
50
10°
30°
40°
40°
50°
90°
100
20°
Y’
30°
40°
70°
70°
80°
80°
90°
100
50
0
50
90°
100
RELATIVE INTENSITY (%)
RELATIVE
INTENSITY (%)
2010.06 - Rev.A
SML-51 Series
Electrical Characteristics Curves
Forward Current-Forward Voltage
FORWARD CURRENT : IF (mA)
■
10
1
■SML-512VW(A)
■SML-512VW
■SML-512UW
■SML-511UW
■SML-512CW(A)
■SML-512DW
■SML-511DW
■SML-512WW
■SML-511WW
■SML-512MW
■SML-511PW(A)
0.1
1
1.5
2
■
■SML512BC5T
■
■SML512BC5T
■
■SML512BC5T
■
■SML512BC5T
10
1
2.8
3
2.5
Ta=25°C
100
FORWARD CURRENT:IF (mA)
Ta=25°C
100
2.9
3.0
3.2
3.1
FORWARD VOLTAGE:VF (V)
FORWARD VOLTAGE : VF (V)
Luminous Intensity-Atmosphere Temperature
RELATIVE LUMINOUS INTENSITY (a.u.)
■
1.4
1.2
1.0
0.8
■SML-511UW
■SML-511DW
■SML-511WW
■SML-512MW
■SML-511PW(A)
■SML-512VW(A)
■SML-512VW
■SML-512UW
■SML-512CW(A)
■SML-512DW
■SML-512WW
0.6
0.4
-40
-20
0
20
40
60
80
IF=5mA
1.6
RELATIVE LUMINOUS INTENSITY (a.u.)
IF=20mA
1.6
1.4
1.2
1.0
0.8
0.6
0.4
-40
100
ATMOSPHERE TEMPERATURE:Ta (°C)
-20
0
20
40
60
80
100
ATMOSPHERE TEMPERATURE:Ta (°C)
Luminous Intensity-Forward Current
RELATIVE LUMINOUS INTENSITY (a.u.)
■
1.0
0.5
■SML-512VW(A)
■SML-512VW
■SML-512UW
■SML-512CW(A)
■SML-512DW
■SML-512WW
■SML-511UW
■SML-511DW
■SML-511WW
■SML-512MW
■SML-511PW(A)
0
0
5
10
15
20
25
Ta=25°C
4.0
RELATIVE LUMINOUS INTENSITY (a.u.)
Ta=25°C
1.5
3.0
2.0
1.0
0
30
0
PEAK FORWARD CURRENT:IF (mA)
5
10
15
20
PEAK FORWARD CURRENT:IF (mA)
Derating
30
20
■SML-511UW
■SML-511DW
■SML-511WW
■SML-512VW(A)
■SML-512VW
■SML-512UW
■SML-512CW(A)
■SML-512DW
■SML-512WW
■SML-512MW
■SML-511PW(A)
MAXIMUM FORWARD CURRENT:IF (mA)
MAXIMUM FORWARD CURRENT:IF (mA)
■
40
10
10
-40
-20
0
20
40
60
80
100
AMBIENT TEMPERATURE:Ta (°C)
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
30
20
10
0
-40
-20
0
20
40
60
80
100
AMBIENT TEMPERATURE:Ta (°C)
2/2
2010.06 - Rev.A
Notice
Notes
No copying or reproduction of this document, in part or in whole, is permitted without the
consent of ROHM Co.,Ltd.
The content specified herein is subject to change for improvement without notice.
The content specified herein is for the purpose of introducing ROHM's products (hereinafter
"Products"). If you wish to use any such Product, please be sure to refer to the specifications,
which can be obtained from ROHM upon request.
Examples of application circuits, circuit constants and any other information contained herein
illustrate the standard usage and operations of the Products. The peripheral conditions must
be taken into account when designing circuits for mass production.
Great care was taken in ensuring the accuracy of the information specified in this document.
However, should you incur any damage arising from any inaccuracy or misprint of such
information, ROHM shall bear no responsibility for such damage.
The technical information specified herein is intended only to show the typical functions of and
examples of application circuits for the Products. ROHM does not grant you, explicitly or
implicitly, any license to use or exercise intellectual property or other rights held by ROHM and
other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the
use of such technical information.
The Products specified in this document are intended to be used with general-use electronic
equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices).
The Products specified in this document are not designed to be radiation tolerant.
While ROHM always makes efforts to enhance the quality and reliability of its Products, a
Product may fail or malfunction for a variety of reasons.
Please be sure to implement in your equipment using the Products safety measures to guard
against the possibility of physical injury, fire or any other damage caused in the event of the
failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM
shall bear no responsibility whatsoever for your use of any Product outside of the prescribed
scope or not in accordance with the instruction manual.
The Products are not designed or manufactured to be used with any equipment, device or
system which requires an extremely high level of reliability the failure or malfunction of which
may result in a direct threat to human life or create a risk of human injury (such as a medical
instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any
of the Products for the above special purposes. If a Product is intended to be used for any
such special purpose, please contact a ROHM sales representative before purchasing.
If you intend to export or ship overseas any Product or technology specified herein that may
be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to
obtain a license or permit under the Law.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact us.
ROHM Customer Support System
http://www.rohm.com/contact/
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
R1010A