MICREL SY10E155JC

6-BIT 2:1
MUX-LATCH
FEATURES
DESCRIPTION
■
■
■
■
■
■
■
The SY10/100E155 offer six 2:1 multiplexers followed
by latches with single-ended outputs, designed for use in
new, high-performance ECL systems. The two external
latch-enable signals (LEN1 and LEN2) are gated through a
logical OR operation before use as control for the six
latches. When both LEN1 and LEN 2 are at a logic LOW, the
latches are transparent, thus presenting the data from the
multiplexers at the output pins. If either LEN1 or LEN2 (or
both) are at a logic HIGH, the outputs are latched.
The multiplexer operation is controlled by the SEL (Select)
signal which selects one of the two bits of input data at each
mux to be passed through.
The MR (Master Reset) signal operates asynchronously
to take all outputs to a logic LOW.
750ps max. LEN to output
Extended 100E VEE range of –4.2V to –5.5V
700ps max. D to output
Single-ended outputs
Asynchronous Master Reset
Dual latch-enables
Fully compatible with industry standard 10KH,
100K ECL levels
■ Internal 75KΩ input pulldown resistors
■ Fully compatible with Motorola MC10E/100E155
■ Available in 28-pin PLCC package
SEL
Q
Q0
E
N R
D4b
D
D4a
D3b
MUX
D5a
D0a
D3a
NC
VCCO
PIN CONFIGURATION
BLOCK DIAGRAM
D0b
SY10E155
SY100E155
25 24 23 22 21 20 19
D2a
MUX
D2b
SEL
D3a
SEL
D4a
MUX
D4b
SEL
D5a
SEL
Q
Q2
E
NR
18
Q5
27
17
VEE
1
Q4
VCC
Q3
MR
SEL
2
D0b
4
28
5
Q
Q3
D
Q
Q4
16
PLCC
TOP VIEW
J28-1
15
6
7
8
9
13
Q2
VCCO
12
Q1
14
3
E
NR
10 11
PIN NAMES
E
NR
D
MUX
D5b
D
D
MUX
D3b
E
NR
26
LEN1
LEN2
Q0
SEL
Q1
D2b
VCCO
D1b
Q
D1b
D2a
D
MUX
D0b
D1a
D1a
D5b
Q
Pin
Q5
E
NR
SEL
LEN1
LEN2
MR
Function
D0a–D5a
Input Data a
D0b–D5b
Input Data b
SEL
Data Select Input
LEN1, LEN2
Latch Enables
MR
Master Reset
Q0–Q5
Outputs
VCCO
VCC to Output
Rev.: C
1
Amendment: /1
Issue Date: February, 1998
SY10E155
SY100E155
Micrel
TRUTH TABLES
SEL
Data
LEN1
LEN2
Latch
H
a
L
L
Transparent
L
b
H
X
Latched
X
H
Latched
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
Parameter
Min.
IIH
Input HIGH Current
IEE
Power Supply Current
10E
100E
TA = +25°C
Typ. Max. Min. Typ.
TA = +85°C
Max.
Min. Typ.
Max.
Unit
Condition
µA
—
mA
—
Unit
Condition
ps
—
ps
—
ps
—
—
—
150
—
—
150
—
—
150
—
—
85
85
102
102
—
—
85
85
102
102
—
—
85
98
102
117
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
Parameter
TA = +25°C
TA = +85°C
Min.
Typ. Max. Min. Typ.
Max.
Min. Typ.
Max.
tPLH
tPHL
Propagation Delay to Output
D
SEL
LEN
MR
325
475
350
450
500
675
500
600
700
925
750
850
325
475
350
450
500
675
500
600
700
925
750
850
325
475
350
450
500
675
500
600
700
925
750
850
tS
Set-up Time
D
SEL
300
500
100
250
—
—
300
500
100
250
—
—
300
500
100
250
—
—
Hold Time
D
SEL
300
0
–100
–250
—
—
300
0
–100
–250
—
—
300
0
–100
–250
—
—
tRR
Reset Recovery Time
800
650
—
800
650
—
800
650
—
ps
—
tPW
Minimum Pulse Width, MR
400
—
—
400
—
—
400
—
—
ps
—
tskew
Within-Device Skew
—
75
—
—
75
—
—
75
—
ps
1
tr
tf
Rise/Fall Time
20% to 80%
300
450
800
300
450
800
300
450
800
ps
—
tH
NOTE:
1. Within-device skew is defined as identical transitions on similar paths through a device.
PRODUCT ORDERING CODE
Ordering
Code
Package
Type
Operating
Range
SY10E155JC
J28-1
Commercial
SY10E155JCTR
J28-1
Commercial
SY100E155JC
J28-1
Commercial
SY100E155JCTR
J28-1
Commercial
2
SY10E155
SY100E155
Micrel
28 LEAD PLCC (J28-1)
Rev. 03
3
SY10E155
SY100E155
Micrel
MICREL-SYNERGY
TEL
3250 SCOTT BOULEVARD SANTA CLARA CA 95054 USA
+ 1 (408) 980-9191
FAX
+ 1 (408) 914-7878
WEB
http://www.micrel.com
This information is believed to be accurate and reliable, however no responsibility is assumed by Micrel for its use nor for any infringement of patents or
other rights of third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent right of Micrel Inc.
© 2000 Micrel Incorporated
4