VECTRON TFS100C

tfs100C.doc
Version 1.1
VI TELEFILTER
Preliminary Specification
20.04.2001
TFS 100C
1/5
1. Measurement condition
Ambient temperature TA:
Input power level:
23 °C
0
dBm.
Terminating impedances in fc:
for input:
for output:
19 Ω  - 52 pF.
38 Ω  - 64 pF.
2. Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 100C is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at
the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency
fc and the frequency response of the filter in the operating temperature range. The bandwidth shift of the filter in the operating temperature
range (OTR) is included in the production tolerance scheme.
Data
typ. value
Insertion loss (Reference level)
Centre frequency
ae
fc at ambient temperature ( fCAT )
22,5 dB
100,0 MHz
0,6...0,8 dB
Bandwidth :
at TA
1
dB - band width
1,3 dB - band width
3
dB - band width
20
33
40
43
48
5,88 MHz
5,91 MHz
6,06 MHz
dB - band width
dB - band width
dB - band width
dB - band width
dB - band width
6,57
6,75
6,84
6,90
7,10
Relative attenuation
fc
fc ± 2,9
fc
fc
fc
fc
±
±
±
±
3,4
3,6
4,0
17,1
max.
25
100,0 ±0,10
dB
MHz
fC - 2,9 MHz ... fC + 2,9 MHz
Pass band ( PB ) at ambient temperature :
Amplitude ripple in PB (p-p):
tolerance / limit
MHz
MHz
MHz
MHz
MHz
max.
1,30
dB
min
min.
5,8
6,0
MHz
MHz
max.
6,8
MHz
max.
max.
7,2
8,0
MHz
MHz
max.
max.
1,3
3
dB
dB
in OTR
arel :
MHz
fc ± 2,9
fc ± 3,0
MHz
MHz
MHz
MHz
MHz
MHz
fc
fc
fc
fc
MHz
MHz
MHz
MHz
±
±
±
±
3,6
4,0
17,1
92
Group delay ( mean value in PB ):
Group delay ripple in PB (p-p):
Deviation from linear phase in PB:
Triple transit attenuation compared to main signal:
Crosstalk:
Temperature coefficient of frequency ( Tcf )
Frequency deviation of fc over temperature
Operating temperature range (OTR) :
Storage temperature range (STR) :
0,8 dB
2,5 dB
36
49...52
50...60
55...70
dB
dB
dB
dB
min.
min.
min.
min.
2,89 µs
130...150
ns
5...7°
max.
max.
47
50...60
3,4
170
dB
dB
dB
dB
µs
ns
dB
dB
- 20
ppm/K
∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz)
- 25 °C ... + 80 °C
- 40 °C ... + 85 °C
Generated:
Wadim Dunzow
Checked/Approved:
Dr. Bert Wall
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
33
43
48
50
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
Email: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs100C.doc
Version 1.1
VI TELEFILTER
Preliminary Specification
3. Package, pin grid 2,54 mm
TFS 100C
20.04.2001
2/5
(All dimensions in mm)
35 Max
TFS
tft
12,7
Datecode:
L
M
N
....
100C
N19
Year+week
1999
2000
2001
........
0,25
5,2
4,5
Dia. 0,45
1 2
3
4
9
12
7,62
Dia. 1
24
21
16 15 14
2,54
Pin 3
Input
Pin 2
Input RF Return
Pin 15
Output
Pin 14
Output RF Return
Pin 1, 4, 9, 12, 13, 16, 21, 24 –
Package Ground
Pin 10, 11, 22, 23 – Dummy
11x2,54 = 27,94
4. 50 Ω - Matching network ( scheme 1, see Application Note ):
C1
50 Ω
1 2
3
4
9
12
L2
L1
50 Ω
C2
24
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
21
16 15 14 13
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
Email: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs100C.doc
Version 1.1
VI TELEFILTER
Preliminary Specification
20.04.2001
TFS 100C
3/5
5. Stability characteristics :
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
Email: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs100C.doc
Version 1.1
VI TELEFILTER
Preliminary Specification
20.04.2001
TFS 100C
4/5
6. Soldering temperature conditions :
1st and 2nd soldering temperature profile
Name:
Temperature:
Time:
pre-heating periods main-heating periods
150 °C - 170 °C
over 200 °C
60 sec. - 90 sec.
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Soldering temperature profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the soldering process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
Email: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs100C.doc
Version 1.1
VI TELEFILTER
Preliminary Specification
20.04.2001
TFS 100C
5/5
7. History :
Version
Reason of Changes
Name
Date
1.0
- edit customer Development Specification.
Dunzow
17 April 2000
Dunzow
20 April 2001
Preliminary Specification:
1.1
- add and correct typical values of filter ;
- add termination impedances of matching networks ;
- add matching network configuration.
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
Email: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.