VECTRON TFS286

Tfs286.doc
version 1.4
24.03.2000
______________________________________________________________________________________________________
VI TELEFILTER
Filter specification
TFS 286
1/5
______________________________________________________________________________________________________
Measurement Condition
Ambient Temperature:
Input Power Level:
Source impedance:
Load impedance:
Terminating impedances:
input:
output:
23 °C
0 dBm
50 Ω single ended
50 Ω single ended
570 Ω || -5.5 pF
570 Ω || -5.3 pF
Construction, pin connection and 50 Ω test circuit
see page 2
Characteristics
Remark:
Reference level for the relative attenuation arel is the pass band attenuation at the nominal frequency fN. It is defined as the insertion loss ae. The
nominal frequency fN is fixed to 286,00 MHz. The given values for the relative attenuation arel and for the phase ripple have to be reached at the
frequencies given below also if the centre frequency fo is shifted due to the temperature coefficient of frequency TCf in the operating temperature
range and due to a production tolerance for the centre frequency fo.
Data
typ. Value
Limit
______________________________________________________________________________________________________
Insertion Loss
max.
8
dB
ae = amin
(Reference level)
______________________________________________________________________________________________________
Nominal Frequency
fN
286,0 MHz
______________________________________________________________________________________________________
3 dB - Bandwidth
min. 400
kHz
BW
______________________________________________________________________________________________________
Pass Band Ripple
max. ± 0,5 dB
fN – 80 kHz ... fN + 80 kHz
______________________________________________________________________________________________________
Relative Attenuation
arel
fN ±
1,8 MHz ... fN ±
6
MHz
min. 20
dB
6
MHz ... fN ±
75
MHz
min. 35
dB
fN ±
MHz ...
fN 75
MHz
min. 20
dB
fN - 285
75
MHz ... fN + 714
MHz
min. 20
dB
fN +
______________________________________________________________________________________________________
Group delay
max.
1
µs
fN
_____________________________________________________________________________________________________
Group delay ripple
max.
1
µs
fN – 80 kHz ... fN + 80 kHz
_____________________________________________________________________________________________________
Input power level
max. + 10
dBm
______________________________________________________________________________________________________
Operating Temperature Range
- 40 °C ... + 85 °C
______________________________________________________________________________________________________
Generated:
Checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs286.doc
version 1.4
24.03.2000
______________________________________________________________________________________________________
VI TELEFILTER
Filter specification
TFS 286
2/5
______________________________________________________________________________________________________
Construction and pin connection
Datecode
TFS 286
M12
1
2
3
10
4
9
5
8
7
1
2
3
4
5
6
7
8
9
10
Output
Ground
Ground
Ground
Ground
Input
Ground
Ground
Ground
Ground
Datecode:
K
L
M
...
Year+week
1998
1999
2000
6
:
50 Ω single ended test circuit
L1
L2
6
Input
50 Ohm
1
Output
50 Ohm
SAW
C1
C2
2,3,4,5,7
8,9,10
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs286.doc
version 1.4
24.03.2000
______________________________________________________________________________________________________
VI TELEFILTER
Filter specification
TFS 286
3/5
______________________________________________________________________________________________________
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Real of empty components at start:
Real of empty components at start including leader:
Trailer
2000
min 300 mm
min 500 mm
min 300 mm
Tape (all dimensions in mm)
EMBOSSED CARRIER
TAPE
W
:
16
± 0,3
Po
:
4
± 0,1
Do
:
1,5
+ 0,5
D1
:
1,5
+ 0,5
Po
D o
P
2
E
A
E
:
1,75 ± 0,1
F
:
7,5 ± 0,1
o
F
G (min) :
D
13,4
1
± 0,1
B
W
o
0,75
P2
:
2
± 0,05
P1
:
12
± 0,1
G
D1(min) :
1,5
Ao
:
7,6
± 0,1
Bo
:
9,6
± 0,1
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
16,4 +2
22,4
>= 90
C
C
:
13
± 0,25
A
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs286.doc
version 1.4
24.03.2000
______________________________________________________________________________________________________
VI TELEFILTER
Filter specification
TFS 286
4/5
______________________________________________________________________________________________________
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs286.doc
version 1.4
24.03.2000
______________________________________________________________________________________________________
VI TELEFILTER
Filter specification
TFS 286
5/5
______________________________________________________________________________________________________
History
Version
Reason of Changes
Name
Date
1.4
- impedances modified
- date code changed and explained
Steiner
24.03.2000
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.