VECTRON TFS370

Tfs370.doc
version 1.3
VI TELEFILTER
29.10.2002
Filter Specification
TFS 370
1/5
Measurement condition
Ambient temperature:
23 C
Input power level:
0 dBm
Terminating impedances *): for input:
for output :
170
170
// -0,50 pF
// -0,50 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 370 is the minimum of the pass band attenuation amin . The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at
the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 370 MHz without tolerance. The given values
for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below even if the centre frequency fc is
shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre
frequency fc.
Data
typ. value
Insertion loss
(Reference level)
ae = amin
Nominal frequency
fN
-
Centre frequency
fc
370
Pass band ripple
(at ambient temperature)
within fN
Relative attenuation
arel
fN
fN fN -
2,80
10 MHz
…fN ± 10 MHz
80 MHz …fN - 100
MHz
35 MHz …fN 25 MHz …fN +
1,30
3 dB
dB
370 MHz
MHz
-
dB
max.
2 dB**
dB
max.
3 dB
60
dB
min.
50 dB
MHz
60
dB
min.
30 dB
57,5 MHz
25
dB
min.
20 dB
57,5MHz …fN + 82,5 MHz
fN + 127,5MHz …fN + 152,5 MHz
60
dB
min.
40 dB
60
db
min.
57 dB
-
min.
20 dBm***
-
max.
10 dBm
-
max.
12 V
fN +
fN +
Intermodulation
55
1,5**
tolerance/limit
IP3
Input power lewel
Permissible DC voltage
VDC
Operating temperature range
- 25 C ... + 75
C
Storage temperature range
- 40 C … + 85
C
Temperature coefficient of frequency
TCf****
-72
ppm/K
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.
**) 2 dB bandwidth ( fN 10 MHz) is guaranteed at ambient temperature (23°C).
***) intermodulation signals:
fN + 1 MHz and fN + 2 MHz, each of 10 dBm
****) fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz)
generated:
checked / approved:
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs370.doc
version 1.3
29.10.2002
VI TELEFILTER
Filter Specification
Construction, pin configuration and 50
- matching network
TFS 370
2/5
(All dimensions in mm)
+0.15
5.0 SQ -0.1
7
5
370
P44
1
3
date code
Pin 1
Pin 2
Pin 3
Pin 4
output
output rf return
ground
package ground
Pin 5
Pin 6
Pin 7
Pin 8
date code:
M
N
P
...
input
input rf return
ground
package ground
year + week
2000
2001
2002
50 Ohm Test circuit
50
test circuit
L1
IN
1
C1
L2
5
SAW
C2
OUT
2,3,4,6,7,8
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs370.doc
version 1.3
VI TELEFILTER
29.10.2002
Filter Specification
TFS 370
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page
4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer
Tape (all dimensions in mm)
W
: 12
± 0,3
Po
:
4
± 0,1
Do
:
1,5 + 0,1
E
:
1,75 ± 0,1
F
:
5,5 ± 0,05
G (min) :
0,75
P2
:
2 ± 0,05
P1
:
8
± 0,1
D1(min) :
1,5
Ao
:
5,3 ± 0,1
Bo
:
5,3 ± 0,1
CT
:
9,5 ± 0,1
3000
min 300 mm
min 500 mm
min 300 mm
EMBOSSED CARRIER TAPE
Do
Po
P2
E
Ao
F
D1
CT
W
Bo
G
P1
COVER TAPE
W2
Reel (all d imensions in mm):
A
W1
:
:
330
12 ,4 + 2 / 0
W2 (m ax) :
N (m in)
:
18 ,4
50
C
13
:
+ 0 ,5 / -0 ,2
A
C
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs370.doc
version 1.3
VI TELEFILTER
29.10.2002
Filter Specification
TFS 370
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs370.doc
version 1.3
VI TELEFILTER
Filter Specification
29.10.2002
TFS 370
5/5
History
Version
Reason of Changes
NameDate
1.0
- generation of specification
Pfeiffer
05.09.2002
1.1
- changing package
Pfeiffer
09.09.2002
1.2
- change of specification of 2 dB bandwidth
Dr. Sabah
21.10.2002
1.3
- change from development specification to filter specification;
add typical values and terminating impedance
Dr. Sabah
29.10.2002
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.