Filename: tfs 1200.doc Version 1.3 VI TELEFILTER 09.06.2006 Filter specification TFS 1200 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 168Ω // -1,0pF 168Ω // -1,0pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 1200 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 1200,0 MHz without any tolerance. The given values for both the relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value Insertion loss (reference level) ae 3,25 Nominal frequency fN - Centre frequency fC PB Passband Relative attenuation fN … fN ± fN ± 3 MHz … fN 6 MHz … fN fN ± 17 MHz … fN fN + 30 MHz … fN fN + 17 MHz … fN fN Group delay ripple within PB ± ± + + - 0,1 6 17 30 180 1150 arel MHz MHz MHz MHz MHz MHz Input power level Operating temperature range OTR Storage temperature range max. TCf ** 6,0 1200,0 MHz dB MHz fN 0,3 dB max. 0,3 ± 100,0 1,0 kHz dB dB max. 1 dB 20 28 33 43 39 19 dB dB dB dB dB ns min. min. min. min. min. max. 15 20 25 30 30 100 dB dB dB dB dB ns 26 dBm max. 15 - - 40 °C ... + 85°C - - 45 °C ... + 90°C 40 Frequency inversion temperature Temperature coefficient of frequency dB p-p Pass band ripple 1200,0 tolerance / limit 0,05 °C ppm/K dBm 2 - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fTo(MHz) Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 1200.doc Version 1.3 VI TELEFILTER 09.06.2006 Filter specification TFS 1200 2/5 Filter characteristic -20 magnitude in dB magnitude in dB -10 -30 -40 -50 -60 1065 1092 1119 1146 1173 1200 1227 frequency in MHz 1254 1281 1308 -2 0.45 -4 0.4 -6 0.35 -8 0.3 -10 1335 0.5 1199 1199.5 1200 1200.5 frequency in MHz 1201 delay in µs 0 0 0.25 1201.5 Construction and pin connection (All dimensions in mm) C00 ● U23 1 2 3 4 5 6 7 8 Ground Input Ground Ground Ground Output Ground Ground Date code: U V W ... Year + week 2006 2007 2008 50 Ohm Test circuit 2 6 1, 3, 4, 5, 7, 8 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Filename: tfs 1200.doc Version 1.3 VI TELEFILTER 09.06.2006 Filter specification TFS 1200 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 – 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 12,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 5,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 4,30 ± 0,1 Bo : 4,30 ± 0,1 Ct : 9,5 ± 0,1 t P1 Date Code Po P2 W G Ct Bo F G E Do Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 12,4 +2/-0 W2(max) : 18,4 N(min) : 50 C : 13,0 +0,5/-0,2 C A N W 1 The minimum bending radius is 45 mm. VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Filename: tfs 1200.doc Version 1.3 VI TELEFILTER 09.06.2006 Filter specification TFS 1200 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Filename: tfs 1200.doc VI TELEFILTER Version 1.3 Filter specification 09.06.2006 TFS 1200 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 13.06.2005 1.1 - Change of input power level to +15dBm Sabah 06.07.2005 1.2 - Add of typical values and typical filter performances Sabah 06.07.2005 1.3 - Improve limit line scheme - Change filter characteristic Noack 09.06.2006 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information