TISP3600F3, TISP3700F3
*R
DUAL BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS
TISP3600F3, TISP3700F3
IEEE Std 802.3 LAN and MAN Applications
SL Package (Top View)
Ion-Implanted Breakdown Region
Precise and Stable Voltage
Terminals
T&G, R&G
T&R
Device
VDRM
V
V(BO)
V
VDRM
V
V(BO)
V
‘3600
420
600
840
1200
‘3700
500
700
1000
1400
T
1
G
2
R
3
MDXXAGB
Device Symbol
T
R
Rated for International Surge Wave Shapes
ITSP
Wave Shape
Standard
2/10
GR-1089-CORE
190
8/20
IEC 61000-4-5
175
10/160
FCC Part 68
110
A
10/700
FCC Part 68
ITU-T K.20/21
70
10/560
FCC Part 68
50
10/1000
GR-1089-CORE
45
SD3XAA
G
Terminals T, R and G correspond to the
alternative line designators of A, B and C
How To Order
Device
Package
Carrier
For Standard
Termination Finish
Order As
For Lead Free
Termination Finish
Order As
TISP3600F3
SL, Single-in-line
TUBE
TISP3600F3SL
TISP3600F3SL-S
TISP3700F3
SL, Single-in-line
TUBE
TISP3700F3SL
TISP3700F3SL-S
Description
These devices are designed to limit overvoltages between systems and so protect their insulation. A single device can be used in two
ways; as a 3-point protector or as a 2-point protector. In the 3-point mode, the G terminal is connected to the system protective ground
and the R and T terminals are connected to the two conductors being protected. For the TISP3600F3, each conductor will have its voltage limited to ±600 V from the protective ground. The maximum inter-conductor voltage will be limited to ±1200 V.
In the 2-point mode, only the outer R and T terminals are connected and the G terminal is unconnected. The TISP3700F3 limits the voltage between the two connection nodes to ±1400 V with voltage limiting beginning above ±1000 V. Two TISP3700F3 devices connected
in series would allow insulation testing to ±2000 V ( 1400 Vrms ).
The protector consists of two symmetrical voltage-triggered bidirectional thyristors with a common connection. Overvoltages are normally caused by a.c. power system or lightning flash disturbances which are coupled on to the system. These overvoltages are initially
clipped by breakdown clamping until the voltage rises to the breakover level, which causes the device to crowbar into a low-voltage on
state. This low-voltage on state causes the current resulting from the overvoltage to be safely diverted through the device. The high
crowbar holding current prevents d.c. latchup as the diverted current subsides.
The TISP3x00F3 is guaranteed to voltage limit and withstand the listed international lightning surges in both polarities.
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex
NOVEMBER 1997 - REVISED FEBRUARY 2005
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP3600F3, TISP3700F3
Absolute Maximum Ratings, TA = 25 °C (Unless Otherwise Noted)
Rating
Symbol
TISP3600F3
TISP3700F3
Repetitive peak off-state voltage, (R-G or T-G value)
Value
± 420
± 500
VDRM
Unit
V
Non-repetitive peak on-state pulse current (see Notes 1 and 2)
2/10 (Telcordia GR-1089-CORE, 2/10 voltage wave shape)
190
1/20 (I TU-T K.22, 1.2/50 voltage wave shape, 25 Ω resistor)
100
8/20 (I EC 61000-4-5, combination wave generator, 1.2/50 voltage wave shape)
175
10/160 (F CC Part 68, 10/160 voltage wave shape)
110
4/250 (I TU-T K.20/21, 10/700 voltage wave shape, simultaneous)
IPPSM
95
5/310 (I TU-T K.20/21, 10/700 voltage wave shape, single)
70
5/320 (F CC Part 68, 9/720 voltage wave shape, single)
70
10/560 (F CC Part 68, 10/560 voltage wave shape)
50
10/1000 (Telcordia GR-1089-CORE, 10/1000 voltage wave shape)
45
Non-repetitive peak on-state current (see Notes 1 and 2)
A
ITSM
6
A
di T/dt
250
A/µs
Junction temperature
TJ
-40 to +150
°C
Storage temperature range
Tstg
-65 to +150
°C
50/60 Hz,
1s
Initial rate of rise of on-state current, Linear current ramp, Maximum ramp value < 38 A
NOTES: 1. Initially, the TISP® device must be in thermal equilibrium with TJ = 25 °C.
2. These non-repetitive rated currents are peak values of either polarirty. The rated current values may be applied to the R or T
terminals. Additionally, both R and T terminals may have their rated current values applied simultaneously (in this case the G
terminal return current will be the sum of the currents applied to the R and T terminals). The surge may be repeated after the TISP
returns to its initial conditions.
Recommended Operating Conditions
Component
Series resistor for GR-1089-CORE first-level surge survival
Series resistor for ITU-T recommendation K.20 and K.21
R1, R2
Series resistor for FCC Part 68 9/720 survival
Series resistor for FCC Part 68 10/160, 10/560 survival
Min
15
0
0
10
Typ
Min
Typ
Max
Unit
Ω
Electrical Characteristics for the T and R Terminals, TA = 25 °C
Parameter
IDRM
Repetitive peak offstate current
Test Conditions
VD = ±2V DRM
V(BO) Breakover voltage
dv/dt = ±700 V/ms, R SOURCE = 300 Ω
I(BO)
dv/dt = ±700 V/ms, R SOURCE = 300 Ω
I T = ±5 A, di/dt = +/-30 mA/ms
IH
dv/dt
ID
Breakover current
Holding current
Critical rate of rise of
off-state voltage
Linear voltage ramp, Maximum ramp value < 1.7VDRM
Off-state current
VD = ±50 V
NOVEMBER 1997 - REVISED FEBRUARY 2005
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP3600F3
TISP3700F3
Max
Unit
±10
µA
±1200
±1400
V
±0.1
A
±0.15
A
kV/µs
±5
±10
µA
TISP3600F3, TISP3700F3
Electrical Characteristics for the T and R Terminals, TA = 25 °C (Continued)
Parameter
Coff
NOTE
Test Conditions
Off-state capacitance
Min
Typ
f = 100 kHz, V d = 1 V rms, VD = 0, (See Note 3)
Max
Unit
0.1
pF
3: These capacitance measurements employ a three terminal capacitance bridge incorporating a guard circuit. The third terminal is
connected to the guard terminal of the bridge.
Electrical Characteristics for the T and G or the R and G Terminals, TA = 25 °C
Parameter
IDRM
Test Conditions
Repetitive peak offstate current
dv/dt = ±700 V/ms, R SOURCE = 300 Ω
I(BO)
dv/dt = ±700 V/ms, R SOURCE = 300 Ω
I T = ±5 A, di/dt = +/-30 mA/ms
IH
dv/dt
ID
Coff
NOTE
Holding current
Typ
VD = ±V DRM
V(BO) Breakover voltage
Breakover current
Min
TISP3600F3
TISP3700F3
Max
Unit
±5
µA
±600
±700
V
A
±0.1
Critical rate of rise of
off-state voltage
Linear voltage ramp, Maximum ramp value < 0.85VDRM
Off-state current
V D = ±50 V
Off-state capacitance
f = 100 kHz, Vd = 1 V rms, VD = 0, (See Note 4)
f = 100 kHz, Vd = 1 V rms, VD = -50 V
±0.15
A
±5
kV/µs
44
11
±10
µA
74
20
pF
4: These capacitance measurements employ a three terminal capacitance bridge incorporating a guard circuit. The third terminal is
connected to the guard terminal of the bridge.
Thermal Characteristics
Parameter
RθJA
NOTE
Junction to free air thermal resistance
Test Conditions
EIA/JESD51-3 PCB, IT = ITSM(1000) ,
TA = 25 °C, (see Note 5)
Min
Typ
Max
Unit
50
°C/W
5: EIA/JESD51-2 environment and PCB has standard footprint dimensions connected with 5 A rated printed wiring track widths.
NOVEMBER 1997 - REVISED FEBRUARY 2005
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP3600F3, TISP3700F3
Parameter Measurement Information
+i
Quadrant I
ITSP
Switching
Characteristic
ITSM
V(BO)
I(BO)
IH
IDRM
VD
VDRM
-v
ID
ID
IDRM
VD
+v
VDRM
IH
I(BO)
V(BO)
ITSM
Quadrant III
I
ITSP
Switching
Characteristic
PMXXAH A
-i
Figure 1. Voltage-Current Characteristic for R-G and T-G Terminal Pairs
+i
Quadrant I
ITSP
Switching
Characteristic
ITSM
V(BO)
I(BO)
IH
IDRM
VD
VDRM
-v
ID
ID
VD
VDRM
+v
IDRM
IH
I(BO)
V(BO)
ITSM
Quadrant III
Switching
Characteristic
ITSP
-i
Figure 2. Voltage-Current Characteristic for R-T Terminal Pair
NOVEMBER 1997 - REVISED FEBRUARY 2005
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
PMXXAJ A
TISP3600F3, TISP3700F3
Typical Characteristics
OFF-STATE CURRENT
vs
JUNCTION TEMPERATURE
100
TC3LAF
1.10
Normalized Breakover Voltage
ID - Off-State Current - µA
10
1
V D = 50 V
0·1
VD = -50 V
0·01
NORMALIZED BREAKOVER VOLTAGE
vs
JUNCTION TEMPERATURE TC3MAIA
1.05
1.00
0.95
0·001
0
25
50
75
100
125
-25
150
0
25
50
75
100
125
150
TJ - Junction Temperature - °C
TJ - Junction Temperature - °C
Figure 3.
Figure 4.
HOLDING CURRENT
vs
JUNCTION TEMPERATURE
0.5
TC3LAHA
0.4
IH - Holding Current - A
-25
0.3
0.2
0.1
-25
0
25
50
75
100
125
150
TJ - Junction Temperature - °C
Figure 5.
NOVEMBER 1997 - REVISED FEBRUARY 2005
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP3600F3, TISP3700F3
Thermal Information
NON-REPETITIVE PEAK ON-STATE CURRENT
vs
CURRENT DURATION
TI4FA A
ITSM(t) - Non-Repetitive Peak On-State Current - A
20
VGEN = 1500 V rms, 50/60 Hz
15
RGEN = 1.4*VGEN/ITSM(t)
EIA/JESD51-2 ENVIRONMENT
EIA/JESD51-3 PCB, TA = 25 °C
10
9
8
7
6
5
SIMULTANEOUS OPERATION
OF R AND T TERMINALS. G
TERMINAL CURRENT = 2xI TSM(t)
4
3
2
1.5
1
0·1
1
10
100
t - Current Duration - s
Figure 6.
NOVEMBER 1997 - REVISED FEBRUARY 2005
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
1000
TISP3600F3, TISP3700F3
APPLICATIONS INFORMATION
IEC 60950, EN 60950, UL 1950 and CSA 22.2 No.950
The ‘950 family of standards have certain requirements for equipment (EUT) with incoming lines of telecommunication network voltage (TNV).
Any protector from a TNV conductor to protective ground must have a voltage rating of at least 1.6 times the equipment rated supply voltage
(Figure 7). The intent is to prevent the possibility of the a.c. main supply voltage from feeding into the telecommunication network and creating
a safety hazard. International and European equipment usually have a maximum rated voltage of 230 V rms, 240 V rms or 250 V rms.
Multiplying the 250 V value by 1.6 gives a protector VDRM value of 400 V. Allowing for operation down 0 °C gives a VDRM requirement of
420 V at 25 °C. This need is met by the TISP3600F3.
Overvoltage Protection
bridging insulation
AC SUPPLY
Te lecommunication
network connection
EUT
Th1
Insulation
Th2
Protective ground
connection
TISP3600F3
AI3XAC
Figure 7. '950 TNV Network Insulation from Protective Ground
LAN System Insulation Protection
Some wired systems are not directly connected to ground and are either floating or have a high resistance to ground. Induced transients may
cause high voltages relative to ground, resulting in arcing across insulation at wiring junctions. Arcing often leaves carbonized tracks which can
degrade system performance. Where the system is carrying a power feed, current conduction through the carbonized track may cause a
safety hazard.
Th3
Th2
D7
D5
D3
D1
D6
D4
D2
Th1
TISP
3x00F3
TISP
3x00F3
D8
TISP
4xxx
AI3XAB
SYSTEM
CONDUCTORS
Figure 8. System Insulation Protection
In Figure 8, a low-protector, Th1, from a TISP4xxx series limits the differential conductor voltage of the system. The use of a diode bridge, D1
through D4, reduces the capacitive loading of the protectors on the system and can be extended to protect more conductors as shown by the
dotted diodes D5 and D6. Low voltage diodes can be used as the maximum reverse voltage stress is limited to the V(BO) value of the
TISP4xxx protector plus the diode forward recovery voltage. Steering diodes D7 and D8 and high-voltage protector Th2 limit the conductor
voltage to ground. The limiting voltage is set by the choice of protector, TISP3600F3, 1200 V or TISP3700F3, 1400 V, and the number
connected in series (one extra protector Th3 shown dotted).
NOVEMBER 1997 - REVISED FEBRUARY 2005
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP3600F3, TISP3700F3
APPLICATIONS INFORMATION
LAN System Insulation Protection (continued)
IEEE Std 802.3, 2000 Edition (IEEE Standard for Information technology— Telecommunications and information exchange between systems—
Local and metropolitan area networks— Specific requirements, Part 3: Carrier sense multiple access with collision detection (CSMA/CD)
access method and physical layer specifications) specifies three network insulation withstands: 1.5 kV rms a.c., 2.25 kV d.c. and 2.4 kV 1.2/50
impulse. Under these conditions there shall be no insulation breakdown, as defined in IEC 60950:1991. Also, there is a 2 MΩ insulation
resistance minimum requirement measured at 500 V d.c. (250 µA maximum).
In Figure 8, at least one protection element of a TISP3700F3 must be used to give the 500 V working voltage (VDRM) to meet the insulation
resistance requirement. To avoid breakover during the 2.4 kV impulse test, five TISP3700F3 protection elements (2.5 kV VDRM, 2-1/2 SL packages) or six TISP3600F3 elements (2.52 kV VDRM, 3 SL packages) are required. Transmitters are required to withstand a 1 kV 0.3/50 commonmode impulse. A TISP3700F3 (1 kV VDRM), from each conductor to ground at the transmitter, would not breakover during the impulse.
BOD Replacement
Figure 9a shows a traditional overvoltage protection scheme for a high power switching thyristor, Th1. The protection voltage level is set by a
BOD (BreakOver Diode) thyristor. Potentially damaging voltage transients cause the BOD to crowbar which turns on thyristor Th1. The on state
of thyristor Th1 causes the current drawn by the load from the d.c. voltage supply +V to continuously increase until the fast acting fuse F1
operates.
Resistor R1 limits the peak BOD current and diode D1 protects the unidirectional BOD against reverse polarity voltage. Resistor R2 provides a
d.c. return, and with capacitor C1, forms a low pass network to prevent false triggering from noise. Further trigger voltage discrimination and
isolation is given by the series combination of zener diode D2 and reverse blocking diode D3. Capacitor C2 and Resistor R3 form the normal
snubber network for the thyristor Th1.
+V
+V
F1
AI3XAA
F1
LOAD
LOAD
R1
R1
R3
R3
D1
TISP
3x00F3
Th1
Th1
BOD
D2
R2
D2
R2
D3
C2
n
D3
C2
C1
C1
a)
GATE
DRIVE
b)
GATE
DRIVE
Figure 9. Thyristor Protection
Figure 9b shows the TISP3x00F3 replacing the unidirectional BOD and reverse polarity protection diode, D1. Reverse polarity protection is not
needed for the TISP3x00F3 as it is bidirectional.
NOVEMBER 1997 - REVISED FEBRUARY 2005
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP3600F3, TISP3700F3
MECHANICAL DATA
Device Symbolization Code
Devices will be coded as follows:
DEVICE
SYMBOLIZATION
CODE
TISP36 00F3
SP3600F3
TISP37 00F3
SP3700F3
NOVEMBER 1997 - REVISED FEBRUARY 2005
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP3600F3, TISP3700F3
MECHANICAL DATA
SL003 3-pin Plastic Single-In-Line Package
This single-in-line package consists of a circuit mounted on a lead frame and encapsulated within a plastic compound. The compound will
withstand soldering temperature with no deformation, and circuit performance characteristics will remain stable when operated in high
humidity conditions. Leads require no additional cleaning or processing when used in soldered assembly.
DIMENSIONS ARE:
SL003
MILLIMETERS
(INCHES)
3.20 - 3.40
(0.126 - 0.134)
9.25 - 9.75
(0.364 - 0.384)
Index
Notch
6.10 - 6.60
(0.240- 0.260)
8.31
(0.327)
MAX.
12.9
(0.492)
MAX.
4.267
(0.168)
MIN.
2
1
3
2.54
Typical
(0.100)
(See Note A)
2 Places
0.203 - 0.356
(0.008- 0.014)
1.854
(0.073)
MAX.
0.559 - 0.711
(0.022 - 0.028)
3 Places
MDXXCEB
NOTES: A. Each pin centerline is located within 0.25 (0.010) of its true longitudinal position.
B. Body molding flash of up to 0.15 (0.006) may occur in the package lead plane.
“TISP” is a trademark of Bourns, Ltd., a Bourns Company, and is Registered in U.S. Patent and Trademark Office.
“Bourns” is a registered trademark of Bourns, Inc. in the U.S. and other countries.
NOVEMBER 1997 - REVISED FEBRUARY 2005
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.