TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 D D D D D D D D D D DB PACKAGE (TOP VIEW) Complete USB Hub Power Solution Meets USB Specifications 1.1 and 2.0 Independent Thermal and Short-Circuit Protection 3.3-V Regulator for USB Hub Controller Overcurrent Logic Outputs 4.5-V to 5.5-V Operating Range CMOS- and TTL-Compatible Enable Inputs 185 µA Bus-Power Supply Current Available in 24-Pin SSOP Package –40°C to 85°C Ambient Temperature Range PG_DLY EN1 AGND PG SP SP NC 3.3V_OUT BPMODE† DP0_RST EN2 DGND description The TPS2074 and TPS2075 provide a complete USB hub power solution by incorporating three major functions: current-limited power switches for four ports, a 3.3-V 100-mA regulator, and a DP0 line control to signal attach/detach of the hub. These devices are designed to meet bus-powered and self-powered hub requirements. These devices are also designed for hybrid hub implementations and allow for automatic switching from self-powered mode to bus-powered mode if loss of self-power is experienced. This feature can be disabled by applying a logic high to the BP_DIS input Each port has a current-limited 100-mΩ Nchannel MOSFET high-side power switch for 500 mA self-powered operation. Each port also has a current-limited 500-mΩ N-channel MOSFET high-side power switch for 100-mA buspowered operation. All the N-channel MOSFETs are designed without parasitic diodes, preventing current backflow into the inputs. For applications where a 5-V regulator is needed, use the TPS2070 or TPS2071 device. 1 24 2 23 3 22 4 21 5 20 6 19 7 18 8 17 9 16 10 15 11 14 12 13 BP_DIS BP OUT1 OUT2 OUT3 OUT4 OC4 OC3 OC2 OC1 EN4 EN3 NC – No internal connection † Pin 9 is active low (BPMODE) for TPS2074 and active high (BPMODE) for TPS2075. simplified hybrid-hub diagram‡ D+ D– Power Supply OUT1 SP 5V GND OUT2 TPS2074 D+ D– OUT3 DP0_RST 5V GND OUT4 BP 3.3 V_OUT BPMODE 1.5 kΩ Downstream Ports Upstream Port VCC EN OC Hub Controller DM0 5V GND 5V GND DP2 DM2 DP3 DM3 DP4 DM4 DP0 D+ D– D+ D– DP1 DM1 D+ D– 5V GND ‡ See Figure 33 for complete implementation. SELECTION GUIDE TA USB HUB POWER CONTROLLERS Four port with internal LDO controller Four-port PACKAGED DEVICES PIN COUNT 32 – 40°C to 85°C Four port without internal LDO controller Four-port 24 BPMODE HTSSOP (DAP) SSOP (DB)† — Active low TPS2070DAP Active high TPS2071DAP — Active low — TPS2074DB Active high — TPS2075DB † The DB package is available taped and reeled. Add an R suffix to the device type (e.g., TPS2074DBR). Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. Copyright 2001, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 1 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 functional block diagram 3.3 V/100 mA LDO 3.3 V_OUT PG PG_DLY BP S1 OUT1 SP S2 SP S3 OUT2 S4 S5 OUT3 S6 S7 OUT4 S8 DPO_RST BP_DIS AGND DGND Control Logic EN1 OC1 EN2 OC2 EN3 OC3 EN4 OC4 BPMODE (TPS2074) BPMODE (TPS2075) 2 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 Terminal Functions TERMINAL NAME PG_DLY† NO. I/O 1 DESCRIPTION Adjusts the PG time delay with a capacitor to ground. Adjust the pulse width to fit the application. EN1 2 I Active-low enable for OUT1 AGND 3 PG 4 O Logic output, power good SP 5 I Self-power voltage input, connects to local power supply SP 6 I Self-power voltage input, connects to local power supply NC 7 3.3V_OUT BPMODE‡ 8 O 3.3-V internal voltage regulator output 9 O A logic signal that indicates if the outputs source from the bus-powered supply, BPMODE (TPS2074) or BPMODE (TPS2075), can be used to signal the hub controller. DP0_RST 10 O Connects to DP signal from upstream hub/host through an external 1.5-kΩ resistor EN2 11 I Active-low enable for OUT2 DGND 12 EN3 13 EN4 OC1 Analog ground No internal connection Digital ground I Active-low enable for OUT3 14 I Active-low enable for OUT4 15 O Logic output, overcurrent response for OUT1 OC2 16 O Logic output, overcurrent response for OUT2 OC3 17 O Logic output, overcurrent response for OUT3 OC4 18 O Logic output, overcurrent response for OUT4 OUT4 19 O Power switch output for downstream ports OUT3 20 O Power switch output for downstream ports OUT2 21 O Power switch output for downstream ports OUT1 22 O Power switch output for downstream ports BP 23 I Bus power voltage input, connect to VBUS BP_DIS 24 I Active-high logic input, disables autoswitch to bus power when self power is disconnected. Connect to BP or GND † Use the following formula to calculate the capacitance needed; C = (desired pulse width × 3 × 10–6 / 1.22 ‡ Pin 9 is active low for TPS2074 and active high for TPS2075. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 3 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 detailed description BP The bus-powered supply input (BP) serves as the source for the internal 3.3-V LDO and for all logic functions in the device. In bus-powered mode, BP also serves as the source for all the outputs (OUTx). If BP is below the undervoltage threshold, all power switches will turn off and the LDO will be disabled. BP must be connected to a voltage source in order for the device to operate. SP The self-powered supply input (SP) serves as the source for all the outputs (OUTx) in self-powered mode. The enable logic for the SP switches requires that BP be connected to a voltage source. OUT1, OUT2, OUT2, OUT4 OUTx are the outputs of the integrated power switches. 3.3V_OUT The internal 3.3-V LDO output can be used to supply up to 100 mA current to low-power functions, such as hub controllers. DP0_RST DP0_RST functions as a hub reset when a 1.5-kΩ resistor is connected between DP0_RST and the upstream DP0 data line in a hub system. To provide a clean attach signal on DP0 data line, the DP0_RST output goes low momentarily (because of the upstream pulldown resistor) to discharge any parasitic charge on the cable, then goes to 3-state and finally outputs a high signal. The low and Hi-Z pulse widths are adjustable using a capacitor between PG_DLY and ground, and are approximately 50% of the power-good time delay. Detachment is signaled by a Hi-Z on DP0_RST. Both DP0_RST and PG will transition high at the same time. Power Good (PG) The power good (PG) function serves as a reset for a USB hub controller. PG is asserted low when the output voltage on the internal voltage regulator is below a fixed threshold. A time delay to ensure a stable output voltage before PG goes high is adjustable using a small-value ceramic capacitor from PG_DLY to ground. PG_DLY PG_DLY connects to an external capacitor to adjust the time delay for PG and DP0_RST. For USB applications, a 0.1 µF capacitor is recommended, however, reference the USB hub controller data sheet to determine the needed pulse width criteria. BP_DIS BP_DIS is used to enable or disable the autoswitching function between bus-powered mode and self-powered mode. When BP_DIS is connected low and the voltage on SP is greater than the undervoltage-lockout (UVLO) threshold, the device will switch to self-powered operation automatically; if the SP voltage falls lower than the UVLO threshold, the device will switch to bus-powered operation. When BP_DIS is connected high, the autoswitching function is disabled and the device will not autoswitch to bus-powered operation if the SP voltage is below the UVLO threshold. BPMODE or BPMODE BPMODE (TPS2074) or BPMODE (TPS2075) is an output that signals when the device is in bus-powered mode. The logic state is set according to the voltages on BP, SP, and BP_DIS. For the TPS2074, BPMODE outputs a low signal to indicate bus-powered mode or a high signal to indicate self-powered mode. For the TPS2075, BPMODE outputs a high signal to indicate bus-powered mode or a low signal to indicate self-powered mode. This output can be used to inform a USB hub controller to configure for bus-powered mode or self-powered mode. 4 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 detailed description (continued) OC1, OC2, OC3, OC4 OCx is an output signal that is asserted (active low) when an overcurrent or overtemperature condition is encountered for the corresponding channel. OCx will remain asserted until the overcurrent or overtemperature condition is removed. EN1, EN2, EN3, EN4, The active-low logic input ENx enables or disables the power switches in the device. The enable input is compatible with both TTL and CMOS logic levels. The switches will not turn on until 3.3V_OUT is above the PG threshold. absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†‡ Input voltage range: VI(BP), VI(SP), VI(ENx), VI(BP_DIS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 6 V Output voltage range: VO(OUTx) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 6 V VO(3.3V_OUT), VO(PG_DLY), VO(OCx), VO(BPMODE), VO(DP0_RST), VO(PG) . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to VO (3.3V_OUT) 0.3 V Continuous output current: IO(OUTx), IO(3.3V_OUT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . internally limited Maximum output current: IO(BPMODE) or IO(BPMODE), IO(DP0_RST), IO(PG), IO(OCx) . . . . . . . . . . ±10 mA Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table Operating virtual junction temperature range, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40°C to 125°C Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C Lead temperature soldering 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . 260°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. ‡ All voltages are with respect to GND. DISSIPATION RATING TABLE PACKAGE TA ≤ 25°C POWER RATING DERATING FACTOR ABOVE TA = 25°C TA = 70°C POWER RATING TA = 85°C POWER RATING 24 DB 889.7 mW 8.9 mW/°C 489.3 mW 355.9 mW recommended operating conditions Input voltage Continuous output current, IO VI(BP) VI(SP) VI(BP_DIS) VI(ENx) MIN MAX 4.5 5.5 0 5.5 0 5.5 0 100 SP to OUTx (per switch) 500 BP to 3.3V_OUT 100 -40 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 V 5.5 BP to OUTx (per switch) Operating virtual junction temperature, TJ UNIT 125 mA °C 5 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 electrical characteristics over recommended operating junction temperature range, 4.5 V ≤ VI(BP) ≤ 5.5 V, 4.85 V ≤ VI(SP) ≤ 5.5 V, ENx = 0 V, BP_DIS = 0 V (unless otherwise noted) input current TEST CONDITIONS† PARAMETER No load N l d on OUTx OUT and d 3.3V_OUT, 3 3V OUT ENx = VI(BP) Input current at BP, switches disabled II(BP) N load l d on OUTx OUT and d 3.3V_OUT, 3 3V OUT No ENx = 0 V Input current at BP, switches enabled No load N l d on OUTx OUT and d 3.3V_OUT, 3 3V OUT ENx = VI(SP) Input current at SP, switches disabled II(SP) No load N l d on OUTx OUT and d 3.3V_OUT, 3 3V OUT ENx = 0 V Input current at SP, switches enabled TYP MAX VI(SP) = Hi-Z VI(SP) = 0 V MIN 185 240 185 240 VI(SP) = 5 V VI(SP) = Hi-Z 175 210 185 240 VI(SP) = 0 V VI(SP) = 5 V 185 240 175 210 VI(BP) = Hi-Z VI(BP) = 0 V 90 115 90 115 VI(BP) = 5 V VI(BP) = Hi-Z 115 140 90 115 VI(BP) = 0 V VI(BP) = 5 V 90 115 115 140 UNIT µA µA µA µA † Pulse-testing techniques maintain junction temperature close to ambient temperature; thermal effects must be taken into account separately. power switches PARAMETER Static drain-source on-state resistance i t rDS(on) DS( ) Ilkg(OUTx) lk (OUT ) TEST CONDITIONS SP to OUTx BP to OUTx Leakage current at OUTx (no load on 3.3V_OUT) Short circuit current Short-circuit (per output)† MIN TYP MAX VI(SP) = VI(BP) = 5 V V, IO 0.5 5A Ox = 0 TA = 25°C TA = 70°C 100 5V VI(BP) = 4 4.5 V, TA = 25°C TA = 70°C 500 600 900 ENx = VI(BP) = 5.5 V, VI(SP) = Hi-Z, OUTx connected to ground, VI(VIN) = Hi-Z TJ = 25°C 0.5 10 ENx = VI(BP) = VI(SP) = 5.5 V, OUTx connected to ground TJ = 25°C 0.5 10 ENx = VI(BP) = Hi-Z or 0 V, VI(SP)= VI(OUTx) = 5.5 V TJ = 25°C 0.5 10 ENx = VI(BP) = VI(SP) = Hi-Z or 0 V, VI(OUTx) = 5.5 V TJ = 25°C 0.5 10 VI(SP) = Open 1A Open, IOx 0.1 O =0 110 150 UNIT mΩ µA VI(BP) = VI(SP) = 5 V, OUTx connected to GND, Device enabled into short circuit 0.6 0.9 1.2 VI(BP) = 5 V, VI(SP) = open, OUTx connected to GND, device enabled into short circuit 0.12 0.2 0.3 A † Pulse-testing techniques maintain junction temperature close to ambient temperature; thermal effects must be taken into account separately. NOTE: All BP to OUTx , SP to OUTx switches and the internal 3.3-V voltage regulator are loaded to the recommended continuous current rating of 100 mA, 500 mA and 100 mA, respectively, for the static drain-source on-state resistance measurements. input signals (ENx, BP_DIS) PARAMETER VIH VIL High-level input voltage II Input current 6 TEST CONDITIONS MIN TYP† MAX 2 Low-level input voltage 0.8 Pullup ENx (active low) Pulldown BP_DIS (active high) POST OFFICE BOX 655303 VI(ENx) = 0 V VI(BP_DIS) = 5 V • DALLAS, TEXAS 75265 5 5 UNIT V µA TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 electrical characteristics over recommended operating junction temperature range, 4.5 V ≤ VI(BP) ≤ 5.5 V, 4.85 V ≤ VI(SP) ≤ 5.5 V, ENx = 0 V, BP_DIS = 0 V (unless otherwise noted) (continued) output signals (BPMODE or BPMODE, OCx, DPO_RST) PARAMETER VOH VOL TEST CONDITIONS BPMODE 4.25 V ≤ VI(BP) ≤ 5.5 V, 4.5 V ≤ VI(SP) ≤ 5.5 V BPMODE 4.25 V ≤ VI(BP) ≤ 5.5 V, VI(SP) < 4 V High level output voltage High-level Low-level output voltage OCx 4.25 V ≤ VI(BP) ≤ 5.5 V, VI(ENx) = 3.3 V or Hi-Z DPO_RST 4.25 V ≤ VI(BP) ≤ 5.5 V, VI(PG_DLY) = 3.3 V BPMODE 4.25 V ≤ VI(BP) ≤ 5.5 V, VI(SP) < 4 V BPMODE 4.25 V ≤ VI(BP) ≤ 5.5 V, 4.5 V ≤ VI(SP) ≤ 5.5 V OCx 4.25 V ≤ VI(BP) ≤ 5.5 V, OUTx = 0 V VI(BP) Minimum input voltage at BP for low-level output Ilkg Hi-Z leakage current at DP0_RST td Overcurrent response delay time (see Note 1) IO = 300 µA, IO = 300 µA, VI(SP) = 5 V MIN TYP MAX UNIT 2.4 2.4 IO = 2 mA V 2.4 2.4 0.4 IO = 3 3.2 2 mA 0.4 IO(OC) = 3.2 mA 0.4 VO(BPMODE)≤ 0.4 V VO(BPMODE)≤ 0.4 V, 1.5 0 V ≤ VI(DPO_RST) ≤ 3.3 V, VI(SP) = 0 V, VI(BP) = 5.5 V, VI(PG_DLY) = 0.9 V 1.5 V V –5 5 µA 1 10 ms NOTE 1: Specified by design, not tested in production. undervoltage lockout (SP and BP) PARAMETER Start threshold Stop threshold Vh hys Hysteresis voltage (see Note 1) TEST CONDITIONS MIN SP BP TYP MAX 4.5 VI(SP) = Hi-Z 4.25 SP 4 BP 3.75 SP 300 BP 300 UNIT V V mV NOTE 1: Specified by design, not tested in production. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 7 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 electrical characteristics over recommended operating junction temperature range, 4.5 V ≤ VI(BP) ≤ 5.5 V, 4.85 V ≤ VI(SP) ≤ 5.5 V, ENx = 0 V, BP_DIS = 0 V, CL(3.3V_OUT) = 10 µF (unless otherwise noted) internal voltage regulator PARAMETER VO TEST CONDITIONS Output voltage, dc VI(BP) = 4.25 V to 5.5 V, IO = 100 mA Dropout voltage Line regulation Short-circuit current limit† Pulldown transistor at 3.3V_OUTPUT _ (see Note 1) PSRR Power-supply ripple rejection (see Note 1) VI(3.3V_OUT) = 3.3 V VI(3.3V_OUT) = 1 V F = 1 kHz, CL(3.3V_OUT)=4.7 µF, ESR=0.25 Ω , IO=5 mA, VI(BP)PP=100 mV Low-level trip threshold voltage at PG Vhys VOH Hysteresis voltage at PG (see Note 1) VOL Vref Low-level output voltage at PG MAX 3.2 3.3 3.4 V 0.1 %/v UNIT V 0.6% 0.12 0.2 0.3 10 40 dB 2.94 50 3 100 2.4 Charge current at PG_DLY V mV V 0.4 Reference voltage at PG_DLY A mA 5 2.88 4.25 V ≤ VI(BP) ≤ 5.25 V, IO = 2 mA 4.25 V ≤ VI(BP) ≤ 5.25 V, IO = 3.2 mA High-level output voltage at PG TYP 0.6 VI(BP) = 4.25 V to 5.25 V, IO= 5 mA VI(BP) = 4.25 V, IO= 5 mA to 100 mA VI(BP) = 4.25 V, 3.3V_OUT connected to GND Load regulation IOS IO= 5 mA to 100 mA MIN V 1.22 V 3 µA td Delay time at PG (see Notes 1 and 2) CL(PG_DLY) = 0.47 µF 190 ms † Pulse-testing techniques maintain junction temperature close to ambient temperature; thermal effects must be taken into account separately. NOTES: 1. Specified by design, not tested in production. 2. The PG delay time (td) is calculated using the PG_DLY reference voltage and charge current: t + d C V ref L(PG_DLY) Charge Current power switch timing requirements TEST CONDITIONS†‡ PARAMETER ton toff ff tr tf Turnon time (see Note 1) Turnoff time (see Note 1) Rise time, time output (see Note 1) Fall time, time output (see Note 1) BP to OUTx switch VI(BP) = 5 V, VI(SP) = open, CL = 100 µF, RL = 50 Ω SP to OUTx switch VI(SP) = VI(BP) = 5 V, TA = 25°C, CL = 100 µF, RL = 10 Ω VI(BP) = 5 V, VI(SP) = open, TA = 25°C, CL = 100 µF, RL = 50 Ω VI(SP) = VI(BP) = 5 V, TA = 25°C, CL = 100 µF, RL = 10 Ω BP to OUTx switch SP to OUTx switch BP to OUTx switch SP to OUTx switch BP to OUTx switch SP to OUTx switch TA = 25°C, VI(BP) = 5 V, VI(SP) = open, TA = 25°C, CL = 100 µF, RL = 50 Ω VI(SP) = VI(BP) = 5 V, TA = 25°C, CL = 100 µF, RL = 10 Ω VI(BP) = 5 V, VI(SP) = open, TA = 25°C, CL = 100 µF, RL = 50 Ω VI(SP) = VI(BP) = 5 V, TA = 25°C, CL = 100 µF, RL = 10 Ω MIN TYP MAX UNIT 4.5 ms 4.5 15 ms 10 4 ms 3 10 ms 3 † Pulse-testing techniques maintain junction temperature close to ambient temperature; thermal effects must be taken into account separately. ‡ All BP to OUTx , SP to OUTx switches and the internal 3.3-V voltage regulator are loaded to the recommended continuous current rating of 100 mA, 500 mA and 100 mA, respectively, for the static drain-source on-state resistance measurements. NOTE 1. Specified by design, not tested in production. 8 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 thermal shutdown PARAMETER TJ Thermal shutdown Hysteresis MIN TYP First 140 Second 150 First 15 Second 25 50% VI(ENx) Current Meter MAX °C °C 50% tpd(off) ton DUT toff tpd(on) IN OUT 90% VO(OUTx) + UNIT 10% 90% 10% tr tf 90% VO(OUTx) 10% 90% 10% TEST CIRCUIT TIMING Figure 1. Current Limit Response Figure 2. Timing and Internal Voltage Regulator Transition Waveforms VI(BP) = 5 V TA = 25°C CL = 10 µF RL = 50 Ω VI(EN) (2 V/div) VI(EN) (2 V/div) VO(out) (2 V/div) VI(BP) = 5 V TA = 25°C CL = 10 µF RL = 50 Ω VO(OUT) (2 V/div) 0 2 4 6 8 10 12 t – time – ms 14 16 18 20 Figure 3. Turnon Delay and Rise Time (BP Switch) POST OFFICE BOX 655303 0 2 4 6 8 10 12 t – time – ms 14 16 18 20 Figure 4. Turnoff Delay and Fall Time (BP Switch) • DALLAS, TEXAS 75265 9 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 PARAMETER MEASUREMENT INFORMATION VI(BP) = VI(SP) = 5 V TA = 25°C CL = 10 µF RL = 10 Ω VI(BP) = VI(SP) = 5 V TA = 25°C CL = 10 µF RL = 10 Ω VI(EN) (2 V/div) VI(EN) (2 V/div) VO(out) (2 V/div) VO(OUT) (2 V/div) 0 2 4 6 8 10 12 t – time – ms 14 16 18 20 0 Figure 5. Turnon Delay and Rise Time (SP Switch) 2 4 6 VI(BP) (2 V/div) VO 3.3V_OUT) (1 V/div) VO (3.3V_OUT) (1 V/div) 8 12 16 20 24 t – time – ms 28 32 36 40 Figure 7. Turnon Delay and Rise Time (3.3V_OUT) 10 16 18 20 TA = 25°C CL = 4.7 µF RL = 33 Ω VI(BP) (2 V/div) 4 14 Figure 6. Turnoff Delay and Fall Time (SP Switch) TA = 25°C CL = 4.7 µF RL = 33 Ω 0 8 10 12 t – time – ms POST OFFICE BOX 655303 0 20 40 60 80 100 120 140 160 180 200 t – time – ms Figure 8. Turnoff Delay and Fall Time (3.3V_OUT) • DALLAS, TEXAS 75265 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 PARAMETER MEASUREMENT INFORMATION VO (3.3V_OUT) (2 V/div) VO (3.3V_OUT) (2 V/div) VO (PG_DLY) (2 V/div) VI(BP) = 5 V TA = 25°C CL(PG_DLY) = 0.47 µF 0 400 800 1200 VI(BP) = 5 V TA = 25°C CL(PG_DLY) = 0.47 µF VO(PG) (2 V/div) 1600 2400 3200 4000 2000 2800 3600 t – time – ms 0 Figure 9. PG_DLY Rise Time With a 0.47-µF Capacitor 100 200 300 400 500 600 700 800 900 1000 t – time – ms Figure 10. Turnon Delay (3.3V_OUT to PG) VI(BP) = 5 V TA = 25°C CL(PG_DLY) = 0.47 µF VI(BP) = 5 V TA = 25°C VO (3.3V_OUT) (2 V/div) VI(EN) (2 V/div) VO(PG) (2 V/div) IO(OUT) (0.1A/div) 0 1 2 3 4 5 6 t – time – ms 7 8 9 10 Figure 11. Turnoff Time (3.3V_OUT to PG) POST OFFICE BOX 655303 0 1 2 3 4 5 6 t – time – ms 7 8 9 10 Figure 12. Short-Circuit Current (BP Switch), Device Enabled Into Short • DALLAS, TEXAS 75265 11 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 PARAMETER MEASUREMENT INFORMATION VI(BP) = VI(SP) = 5 V TA = 25°C VI(BP) = VI(SP) = 5 V TA = 25°C VI(EN) (2 V/div) VO(OC) (2 V/div) IO(OUT) (0.5 A/div) IO(OUT) (0.5 A/div) 0 1 2 3 4 5 6 t – time – ms 7 8 9 0 10 1 2 3 VO(OC) (2 V/div) VO(PG) (2 V/div) IO(OUT) (0.1 A/div) VO (3.3V_OUT) (1 V/div) 2 3 4 5 6 t – time – ms 7 8 9 10 0 2 9 POST OFFICE BOX 655303 4 6 8 10 12 t – time – ms 14 16 18 Figure 16. SP to BP Automatic Switchover Enabled Figure 15. OC Response (BP Switch), Device Enabled Into Short 12 8 10 VI(BP) = 5 V TA = 25°C BP_DIS = 0 V or Open CL(3.3 V_OUT) = 4.7 µF RL(3.3 V_OUT) = 33 Ω CL(PG_DLY) = 0.47 µF VI(BP) = 5 V TA = 25°C 1 7 Figure 14. OC Response (SP Switch), Device Enabled Into Short Figure 13. Short-Circuit Current (SP Switch), Device Enabled Into Short 0 4 5 6 t – time – ms • DALLAS, TEXAS 75265 20 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 PARAMETER MEASUREMENT INFORMATION VI(BP) = 5 V TA = 25°C BP_DIS = 0 V or Open VI(BP) = 5 V TA = 25°C BP_DIS = 5 V VO(PG) (2 V/div) VO(PG) (2 V/div) VO (3.3V_OUT) (1 V/div) VO (DPO_RST) (1 V/div) 0 1 2 3 4 5 6 t – time – ms 7 8 9 0 10 Figure 17. SP to BP Automatic Switchover Disabled 40 80 120 160 200 240 280 320 360 400 t – time – ms Figure 18. SP to BP Automatic Switchover Enabled VI(BP) = 5 V TA = 25°C BP_DIS = 5 V 5.25 V VI(BP) 4.25 V VO(PG) (2 V/div) ∆VO (3.3V_OUT) (0.05 V/div) VO (DPO_RST) (1 V/div) TA = 25°C CL (3.3 V–OUT) = 4.7 µF IO (3.3 V–OUT) = 100 mA 0 40 80 120 160 200 240 280 320 360 400 t – time – ms Figure 19. SP to BP Automatic Switchover Disabled POST OFFICE BOX 655303 0 100 200 300 400 500 600 700 800 900 1000 t – time – µs Figure 20. Line Transient Response • DALLAS, TEXAS 75265 13 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 PARAMETER MEASUREMENT INFORMATION TA = 25°C CL (3.3 V_OUT) = 10 µF IO(3.3 V_OUT) (100 mA/div) ∆VO (3.3 V_OUT) (100 mV/div) 0 100 200 300 400 500 600 700 800 900 1000 t – Time – µs Figure 21. Load Transient Response TYPICAL CHARACTERISTICS BP SUPPLY CURRENT vs INPUT VOLTAGE BP SUPPLY CURRENT vs JUNCTION TEMPERATURE 205 196 VI(BP) = 5 V 200 192 190 Output Enabled 188 186 184 Output Disabled 182 I I(BP) – Supply Current – µ A I I(BP) – Supply Current – µ A 194 195 185 Output Disabled 180 175 170 180 –60 –40 –20 0 20 40 60 80 100 120 140 165 4.25 TJ – Junction Temperature – °C Figure 22 14 Output Enabled 190 4.5 5.25 4.75 5 VI(BP) – Input Voltage – V Figure 23 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 5.5 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 TYPICAL CHARACTERISTICS SP SUPPLY CURRENT vs INPUT VOLTAGE SP SUPPLY CURRENT vs JUNCTION TEMPERATURE 120 120 VI(SP) = 5 V 115 I I(SP) – Supply Current – µA I I(SP) – Supply Current – µ A 115 110 Outputs Disabled 105 Outputs Enabled 100 Outputs Disabled 110 Outputs Enabled 105 100 95 4.5 95 –60 –40 –20 0 20 40 60 80 100 120 140 TJ – Junction Temperature – °C 200 VI(SP) = 5 V 160 140 120 100 80 60 40 20 0 –40 85 0 25 TJ – Junction Temperature – °C 125 DS(on) – Static Drain-Source On-State Resistance – Ω STATIC DRAIN-SOURCE ON-STATE RESISTANCE vs JUNCTION TEMPERATURE (SELF-POWER SWITCHES) 180 5.5 Figure 25 r r DS(on) – Static Drain-Source On-State Resistance – Ω Figure 24 5 VI(SP) – Input Voltage – V STATIC DRAIN-SOURCE ON-STATE RESISTANCE vs JUNCTION TEMPERATURE (BUS POWER SWITCHES) 800 700 600 500 400 VI(BP) = 5.5 V VI(BP) = 4.25 V 300 200 100 0 –40 85 0 25 TJ – Junction Temperature – °C 125 Figure 27 Figure 26 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 15 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 TYPICAL CHARACTERISTICS SHORT-CIRCUIT OUTPUT CURRENT vs JUNCTION TEMPERATURE (BUS-POWER SWITCHES) SHORT-CIRCUIT OUTPUT CURRENT vs JUNCTION TEMPERATURE (BUS-POWER SWITCHES) 300 250 VI(BP) = 5.5 V 280 I OS – Short-Circuit Output Current – mA I OS – Short-Circuit Output Current – mA VI(BP) = 4.25 V 260 240 220 200 180 160 140 –40 0 25 85 230 210 190 170 150 130 110 –40 125 TJ – Junction Temperature – °C SHORT-CIRCUIT OUTPUT CURRENT vs JUNCTION TEMPERATURE (SELF-POWER SWITCHES) I OS – Short-Circuit Output Current – mA VI(SP) = 5 V 980 960 940 920 900 880 860 840 820 0 25 85 TJ – Junction Temperature – °C 125 VI(BP) – Input Voltage (BP Undervoltage Lockout) – V INPUT VOLTAGE (BP UNDERVOLTAGE LOCKOUT) vs JUNCTION TEMPERATURE 1000 4.25 Start Threshold 4.2 4.15 4.1 4.05 4 3.95 3.9 3.85 Stop Threshold 3.8 3.75 –50 Figure 30 16 125 Figure 29 Figure 28 800 –40 0 25 85 TJ – Junction Temperature – °C 100 0 50 TJ – Junction Temperature – °C Figure 31 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 150 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 TYPICAL CHARACTERISTICS VI(SP) – Input Voltage (SP Undervoltage Lockout) – V INPUT VOLTAGE (SP UNDERVOLTAGE LOCKOUT) vs JUNCTION TEMPERATURE 4.5 4.45 Start Threshold 4.4 4.35 4.3 4.25 4.2 4.15 4.1 Stop Threshold 4.05 4 –50 100 0 50 TJ – Junction Temperature – °C 150 Figure 32 APPLICATION INFORMATION external capacitor requirements A 0.1-µF ceramic bypass capacitor and a 10-µF bulk capacitor between BP and AGND, close to the device, are recommended. Similarly, a 0.1-µF ceramic and a 68-µF bulk capacitor, from SP to AGND, and from VEXT to AGND if an external 5-V LDO is required, are recommended because of much higher current in the self-powered mode. From each of the outputs (OUTx) to ground, a 33-µF or higher valued bulk capacitor is recommended when the output load is heavy. This precaution reduces power-supply transients. Additionally, bypassing the outputs with a 0.1-µF ceramic capacitor improves the immunity of the device to short-circuit transients. An output capacitor connected between 3.3V_OUT and GND is required to stabilize the internal control loop. The internal LDO is designed for a capacitor range of 4.7 µF to 33 µF with an ESR of 0.2 Ω to 10 Ω. Solid tantalum-electrolytic, aluminum-electrolytic, and multilayer ceramic capacitors are all suitable. Ceramic capacitors have different types of dielectric material, each exhibiting different temperature and voltage variations. The most common types are X5R, X7R, Y5U, Z5U, and NPO. The NPO type ceramic capacitors are generally the most stable over temperature. However, the X5R and X7R are also relatively stable over temperature (with the X7R being the more stable of the two) and are therefore acceptable for use. The Y5U and Z5U types provide high capacitance in a small geometry, but exhibit large variations over temperature. For this reason, the Y5U and Z5U are not generally recommended. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 17 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 APPLICATION INFORMATION external capacitor requirements (continued) A transient condition occurs because of a sudden increase in output current. The output capacitor reduces the transient effect by providing the additional current needed by the load. Depending on the current demand at the output, a voltage drop will occur across the internal resistance, ESR, of the capacitor. Using a low ESR capacitor will help minimize this voltage drop. A larger capacitor will also reduce the voltage drop by supplying the current demand for a longer time, versus that provided by a smaller capacitor. overcurrent An internal sense FET checks for overcurrent conditions. Unlike current-sense resistors, sense FETs do not increase the series resistance of the current path. When an overcurrent condition is detected, the device maintains a constant output current and reduces the output voltage accordingly. Complete shutdown occurs only if the fault is present long enough to activate thermal limiting. Three possible overload conditions can occur. In the first condition, the output has been shorted before the device is enabled or before BP and SP have been applied. The TPS2074 and TPS2075 sense the short and immediately switch into a constant-current output. In the second condition, the short occurs while the device is enabled. At the instant the short occurs, very high currents may flow for a very short time before the current-limit circuit can react. After the current-limit circuit has tripped (reached the overcurrent trip threshold), the device switches into constant-current mode. In the third condition, the load has been gradually increased beyond the recommended operating current. The current is permitted to rise until the current-limit threshold is reached or until the thermal limit of the device is exceeded. The TPS2074 and TPS2075 are capable of delivering current up to the current-limit threshold without damaging the device. Once the threshold has been reached, the device switches into its constant-current mode. OC response The OCx output is asserted (active low) when an overcurrent or overtemperature condition is encountered and will remain asserted until the overcurrent or overtemperature condition is removed. Connecting a heavy capacitive load to an enabled device can cause momentary false overcurrent reporting from the inrush current flowing through the device and charging the downstream capacitor. The TPS2074 and TPS2075 are designed to reduce false overcurrent reporting by implementing an internal deglitch circuit. This circuit eliminates the need for an external filter, which requires extra components. Also, using low-ESR electrolytic capacitors on the outputs can reduce erroneous overcurrent reporting by providing a low-impedance energy source to lower the inrush current flow through the device during hot-plug events. The OCx outputs are logic outputs thereby requiring no pullup or pulldown resistors. 18 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 APPLICATION INFORMATION power dissipation and junction temperature The major source of power dissipation for the TPS2074 and TPS2075 comes from the internal voltage regulator and the N-channel MOSFETs. Checking the power dissipation and junction temperature is always a good design practice. Begin by determining the rDS(on) of the N-channel MOSFET according to the input voltage and operating temperature. As an initial estimate, use the highest operating ambient temperature of interest and read rDS(on) from the graphs shown under the typical characteristics section of this data sheet. Using this value, the power dissipation per switch can be calculated by: PD + rDS(on) I2 Multiply this number by four to get the total power dissipation coming from the N-channel MOSFETs. ǒ Ǔ The power dissipation for the internal voltage regulator is calculated using: PD + V I(BP) –V O(min) I O(OUT) ǒ The total power dissipation for the device becomes: P D(total) + PD(voltage regulator) ) 4 P D(switch) Ǔ Finally, calculate the junction temperature: TJ Where: + PD R qJA ) TA TA = ambient temperature °C RθJA = Thermal resistance °C /W, equal to inverting of derating factor found on the power dissipation table in this data sheet. Compare the calculated junction temperature with the initial estimate. If they do not agree within a few degrees, repeat the calculation, using the calculated value as the new estimate. Two or three iterations are generally sufficient to get a reasonable answer. thermal protection Thermal protection prevents damage to the IC when heavy-overload or short-circuit faults are present for extended periods. The faults force the TPS2074 and TPS2075 into constant-current mode at first, which causes the voltage across the high-side switch to increase; under short-circuit conditions, the voltage across the switch is equal to the input voltage. The increased dissipation causes the junction temperature to rise to high levels. The protection circuit senses the junction temperature of the switch and shuts it off. Hysteresis is built into the thermal sense circuit, and after the device has cooled approximately 20 degrees the switch turns back on. The switch continues to cycle in this manner until the load fault or input power is removed. The TPS2074 and TPS2075 implement a dual thermal trip to allow fully independent operation of the power distribution switches. In an overcurrent or short-circuit condition the junction temperature rises. Once the die temperature rises to approximately 140°C, the internal thermal-sense circuitry determines which power switch is in an overcurrent condition and turns only that power switch off, thus isolating the fault without interrupting operation of the adjacent power switch. If the die temperature exceeds the first thermal trip point of 140°C and reaches 150°C, the device turns off. The OC output is asserted (active low) when overtemperature or overcurrent occurs. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 19 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 APPLICATION INFORMATION undervoltage lockout (UVLO) An undervoltage lockout ensures that the device (LDO and switches) is in the off state at power up. The UVLO will also keep the device from being turned on until the power supply has reached the start threshold (see undervoltage lockout table), even if the switches are enabled. The UVLO will activate whenever the input voltage falls below the stop threshold as defined in the undervoltage lockout table. This facilitates the design of hot-insertion systems where it is not possible to turn off the power switches before input power is removed. Upon reinsertion, the power switches will be turned on with a controlled rise time to reduce EMI and voltage overshoots. self-power to bus-power or bus-power to self-power transition An autoswitching function between bus-powered mode and self-powered mode is a feature of the TPS2074 and TPS2075. When this feature is enabled (BP_DIS is inactive) and SP is removed or applied, a transition will be initiated. The transition sequence begins with the internal LDO being turned off and its external capacitance discharged. Any enabled switches are also turned off and the external capacitors discharged. Once the LDO and switch outputs are low, the internal logic will turn the LDO back on. This entire sequence occurs whenever power to the SP input is removed or applied, regardless of the source of power, i.e., an external power supply or the use of the external regulator. universal serial bus (USB) applications The universal serial bus (USB 1.1) interface is a 12-Mb/s, 1.5-Mb/s, or 480 Mb/s (USB 2.0), multiplexed serial bus designed for low-to-medium bandwidth PC peripherals (e.g., keyboards, printers, scanners, and mice). The four-wire USB interface is conceived for dynamic attach-detach (hot plug-unplug) of peripherals. Two lines are provided for differential data, and two lines are provided for 5-V power distribution. USB data is a 3.3-V-level signal, but power is distributed at 5 V to allow for voltage drops in cases where power is distributed through more than one hub or across long cables. Each function must provide its own regulated 3.3 V from the 5-V input or its own internal power supply. The USB specification defines the following five classes of devices, each differentiated by power-consumption requirements: D D D D D Hosts/self-powered hubs (SPH) Bus-powered hubs (BPH) Low-power, bus-powered functions High-power, bus-powered functions Self-powered functions Self-powered and bus-powered hubs distribute data and power to downstream functions. The TPS2074 and TPS2075 can provide power-distribution solutions for hybrid hubs that need switching between BPH and SPH according to power availability and application requirements. 20 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 APPLICATION INFORMATION USB power-distribution requirements USB can be implemented in several ways, and, regardless of the type of USB device being developed, several power-distribution features must be implemented. D Hosts/self-powered hubs must: – – – D Bus-powered hubs must: – – – – – D Current-limit downstream ports Report overcurrent conditions on USB VBUS Output 5.25 V to 4.75 at 500 mA Enable/disable power to downstream ports Power up at <100 mA Limit inrush current (<44 Ω and 10 µF) Output 5.25 V to 4.4 at 100 mA Not send power back upstream Functions must: – – – Limit inrush currents Power up at <100 mA Not send power back upstream (SP functions) The feature set of the TPS2074 and TPS2075 allows them to meet each of these requirements. The integrated current-limiting and overcurrent reporting is required by hosts and self-powered hubs. The logic-level enable and controlled rise times meet the needs of both input and output ports on hubs, as well as the input ports for bus-powered functions USB hybrid hub A USB hybrid hub can be simply implemented using the TPS2075 USB power controller and a TUSB2046 USB hub controller as shown in Figure 33. The TPS2075 USB power controller provides all the power needs to the four downstream ports and meets all the USB power specifications for both self-powered hubs and bus-powered hubs. The power controllers integrated 3.3-V LDO is used to provide power for the hub controller and any other local functions (e.g. transient suppressor SN75240 ), which saves board space and cost. The TPS2075 also provides the hub controller with a power good (PG) signal that connects to the RESET input of the hub controller to automatically reinitialize the hub when switching between self-powered mode and bus-powered mode whenever the self-power supply is connected or disconnected. The amount of time in which the hub controller is kept in a reset state is controlled by a capacitor connected between the PG_DLY pin of the power controller and ground. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 21 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 APPLICATION INFORMATION Downstream Ports TUSB2046B Upstream Ports D+ DP1 DM1 D+ DP0 D– DM0 A C B D GND 5V SN75240 A C EECLK EEDATA B D EXTMEM BUSPWR DP2 D+ D– GND DM3 SN75240 VCC1_3.3 0.1 µF 5V DM2 DP3 RESET 10 µF GND 33 µF SUSPEND 0.1 µF D– SN75240 A C B D 5V 33 µF VCC2_3.3 DP4 DM4 D+ TPS2075 XTAL1 33 pF 6 MHz 1.5 kΩ 33 pF XTAL2 PWRON1 OVRCUR1 EN1 OC1 OUT1 PWRON2 EN2 OC2 OUT3 OVRCUR2 D– GND OUT2 5V 33 µF EN3 OC3 PWRON3 TSTPLL TSTMODE OVRCUR3 PWRON4 GND OVRCUR4 GND D+ D– EN4 OC4 GND 5V OUT4 33 µF 3.3 V 4.7 µF 0.1 µF 5 V Power Supply SP BP_DIS SP 68 µF 0.1 µF PG_DLY 0.1 µF PG BPMODE 1.5 kΩ AGND DGND DP0_RST BP Figure 33. USB Hybrid Hub Using TPS2075 Power Controller and TUSB2046 Hub Controller 22 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TPS2074, TPS2075 FOUR-PORT USB HUB POWER CONTROLLERS SLVS288A – SEPTEMBER 2000 – REVISED FEBRUARY 2001 MECHANICAL DATA DB (R-PDSO-G**) PLASTIC SMALL-OUTLINE PACKAGE 28 PINS SHOWN 0,38 0,22 0,65 28 0,15 M 15 0,15 NOM 8,20 7,40 5,60 5,00 Gage Plane 1 14 0,25 A 0°– 8° 1,03 0,63 Seating Plane 2,00 MAX 0,10 0,05 MIN PINS ** 8 14 16 20 24 28 30 38 A MAX 3,30 6,50 6,50 7,50 8,50 10,50 10,50 12,90 A MIN 2,70 5,90 5,90 6,90 7,90 9,90 9,90 12,30 DIM 4040065 / C 10/95 NOTES: A. B. C. D. All linear dimensions are in millimeters. This drawing is subject to change without notice. Body dimensions do not include mold flash or protrusion not to exceed 0,15. Falls within JEDEC MO-150 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 23 PACKAGE OPTION ADDENDUM www.ti.com 4-Mar-2005 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Drawing Pins Package Eco Plan (2) Qty Lead/Ball Finish MSL Peak Temp (3) TPS2074DB ACTIVE SSOP DB 24 60 None CU NIPDAU Level-1-220C-UNLIM TPS2074DBR ACTIVE SSOP DB 24 2000 None CU NIPDAU Level-1-220C-UNLIM TPS2075DB ACTIVE SSOP DB 24 60 None CU NIPDAU Level-1-220C-UNLIM TPS2075DBR ACTIVE SSOP DB 24 2000 None CU NIPDAU Level-1-220C-UNLIM (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - May not be currently available - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. None: Not yet available Lead (Pb-Free). Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Green (RoHS & no Sb/Br): TI defines "Green" to mean "Pb-Free" and in addition, uses package materials that do not contain halogens, including bromine (Br) or antimony (Sb) above 0.1% of total product weight. (3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDECindustry standard classifications, and peak solder temperature. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 1 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Amplifiers amplifier.ti.com Audio www.ti.com/audio Data Converters dataconverter.ti.com Automotive www.ti.com/automotive DSP dsp.ti.com Broadband www.ti.com/broadband Interface interface.ti.com Digital Control www.ti.com/digitalcontrol Logic logic.ti.com Military www.ti.com/military Power Mgmt power.ti.com Optical Networking www.ti.com/opticalnetwork Microcontrollers microcontroller.ti.com Security www.ti.com/security Telephony www.ti.com/telephony Video & Imaging www.ti.com/video Wireless www.ti.com/wireless Mailing Address: Texas Instruments Post Office Box 655303 Dallas, Texas 75265 Copyright 2005, Texas Instruments Incorporated