MA-COM TR600-160-RA

Tyco / Electronics
PolySwitch®
PTC Devices
Raychem Circuit Protection
308 Constitution Drive
Menlo Park, CA 94025-1164
Phone: 800-227-4856
FAX 800-227-4866
PRODUCT: TR600-160-RA
DOCUMENT: SCD 24953
PCN: 041478
REV LETTER: A
REV DATE: JANUARY 29, 2002
PAGE NO.: 1 OF 1
Overcurrent Protection Device
Specification Status: Released
Max Electrical Rating at 20°°C
Operating Voltage: 250VDC
Fault Voltage: 600VRMS
Interrupt Current: 3ARMS
A
C
Lead Material :
22 AWG Sn/Pb plated copper
F
Marking:
B
Raychem Logo
and Voltage
600
160
D
Part Identification
Lot Identification
E
CENTER TO CENTER
TABLE I. DIMENSIONS:
A
mm:
in:
MIN
---
B
MAX
16.0
(0.630)
MIN
---
C
MAX
12.6
(0.496)
MIN
---
D
MAX
MIN
6.0
4.7
(0.236) (0.185)
E
MAX
---
NOM
5.0
(0.197)
F
MIN
MAX
10.0
(0.394)
TABLE II. PERFORMANCE RATINGS @ 20°°C (unless otherwise noted):
IHOLD (A)
20°C
0.160
60°C
0.100
RESISTANCE (Ω)
R MIN
4.0
R MAX
7.0
R1 MAX*
16.0
OPERATING
TYPICAL
TIME TO TRIP (S) TEMPERATURE (°C)
@ 1A
TYP
MIN
MAX
9.5
-40
85
* Maximum device resistance @ 20°C measured 1 hour post trip.
Storage Temperature:
Reference Documents:
Precedence:
Effectivity:
CAUTION:
-40° to 85°C
PS300
This specification takes precedence over documents referenced herein.
Reference documents shall be the issue in effect on the date of invitation for bid.
Operation beyond the rated voltage or current may result in rupture, electrical arcing or flame.