CUI VPPQ

VPPQ-1003D 100W Quad Output with PFC Function
Features
·Universal AC input / Full range
·Built-in active PFC function
·Short circuit, overload, over-voltage protected
·Cooling by free air convection
·100% full load burn-in test
·Fixed switching frequency at PFC:67KHz
PWM:134KHz (Optional)
·2 year warranty
CH1
CH2
CH3
CH4
DC output voltage
Output V. tolerance
3.3V
±3%
5V
±3%
12V
±6%
24V
±6%
Output rated current
Output current range
Ripple & noise
Line regulation
Load regulation
DC output power
Efficiency
DC voltage adj.
Input voltage range
AC current
Inrush current
Leakage current
Overload protection
10A
10A
2A
0.3A
0~15A
2~15A
0.2~3A
0~1A
100mV
100mV
180mV
150mV
±1%
±1%
±2%
±1%
±2%
±2%
±6%
±1%
114.2W
72%
+10%
-5%
------90 ~ 264VAC
127 ~370VDC
1.65A/115V
0.85A/230V
cold start 40A
<1mA /240VAC
105%-135%
type: Hiccup mode, recovers automatically after fault condition is removed
CH1: 3.6 ~ 4.3V
CH2: 5.75 ~ 6.75V
±0.03% / ºC (0~50ºC)
800ms, 50ms, 16ms at full load
PF>0.95/230VAC
PF>0.98/115VAC at full load
10~500Hz, 2G 10 min./1 cycle, period of 60 min. each axes
I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, for 1 min.
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms min.
-10°C~+60% (refer to output derating curve), 20%-90% RH
-20°C~+85°C, 10%-95% RH
7x4.25x1.5 inches (178x108x38 mm)
1.1 lb. (0.5 Kg)
UL1950, TUV EN60950 Approved
Meets CISPR22 (EN55022) Class B
Over voltage protection
Temperature coefficient
Set up, rise, hold up time
Power factor
Vibration
Withstand voltage
Isolation resistance
Working temp., humidity
Storage temp., humidity
Dimensions
Weight
Safety standards
EMC standards
Notes:
1. All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient
2. Tolerance includes set up tolerance, line regulation, load regulation
3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor
4. Line regulation is measured from low line to high line at rated load
5. Load regulation is measured from 20% to 100% rated load, and oother output at 60% rated load
6. Each output provide up to maximum current, but total load cannot exceed max. output power
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty.
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005
www.v-infinity.com
1-866-372-1258
VPPQ-1003D 100W Quad Output with PFC Function
Output Derating
Dimensions (mm)
Static Characteristics