EXAR XRK4991IJ-5

xr
XRK4991
3.3V HIGH-SPEED (85 MHZ) PROGRAMMABLE SKEW CLOCK BUFFER
OCTOBER 2005
REV. 1.0.1
FUNCTIONAL DESCRIPTION
FEATURES
The XRK4991 is a 3.3V High-Speed Low-Voltage
Programmable Skew Clock Buffer. It is intended for
high-performance computer systems and offers user
selectable control over system clock functions to
optimize timing. Eight outputs, arranged in four
banks, can each drive 50Ω terminated transmission
lines while delivering minimal and specified output
skews and full-swing Low Voltage TTL logic levels.
• 3.75- to 85-MHz output operation
• All output pair skew <100 ps typical
• Three skew grades
Each bank (two outputs per bank) can be individually
selected for one of nine delay or function
configurations through two dedicated tri-level inputs.
These outputs are able to lead or lag the CLKIN input
reference clock by up to 6 time units from their
nominal “zero” skew position. The integrated PLL
allows external load and transmission line delay
effects to be canceled achieving zero delay capability.
Combining the zero delay capability with the
selectable output skew functions, output-to-output
delays of up to ±12 time units can be created.
• Selectable output functions
The XRK4991’s divide functions (divide-by-two and
divide-by-four) allow distribution of a low-frequency
clock that can be multiplied by two or four at the clock
destination. This feature facilitates clock distribution
while allowing maximum system clock flexibility.
• Zero input-to-output delay
• 50% duty-cycle outputs
• LVTTL outputs drive 50Ω terminated lines
• Operates from a single 3.3V supply
• 32-pin PLCC package
• Green packaging
• Lead free lead frame available
-2 : tSKEW0<250ps
-5 : tSKEW0<500ps
-7 : tSKEW0<700ps
Skew adjustments of +/- 6tU (up to 18 ns)
Inverted and non-inverted
Operation at 1/2 and 1/4 input frequency
Operation at 2x and 4x input frequency
• Cycle-Cycle Jitter
< 25 ps (rms)
< 200 ps (pk-pk)
FIGURE 1. BLOCK DIAGRAM OF THE XRK4991
CLKIN
Ref
QA0
M
QA1
L
PLL
FB_IN
H
QB0
Feedback
Bank “SKEW”
Control
FSEL*
QB1
QC0
PLL_BYPASS*
QC1
SELA[1:0]*
SELB[1:0]*
SELC[1:0]*
SELD[1:0]*
2
2
2
2
QD0
QD1
* Tri-Level inputs
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • (510) 668-7000 • FAX (510) 668-7017 • www.exar.com
xr
XRK4991
3.3V HIGH-SPEED (85 MHZ) PROGRAMMABLE SKEW CLOCK BUFFER
REV. 1.0.1
PRODUCT ORDERING INFORMATION
PRODUCT NUMBER
ACCURACY
TEMPERATURE RANGE
XRK4991IJ-2
250 ps
-40°C to +85°C
XRK4991CJ-2
250 ps
0°C to +70°C
XRK4991IJ-5
500 ps
-40°C to +85°C
XRK4991CJ-5
500 ps
0°C to +70°C
XRK4991CJ-7
750 ps
0°C to +70°C
SELC0
FSEL
VCCQ
CLKIN
GND
PLL_BYPASS
SELB1
FIGURE 2. PIN OUT OF THE XRK4991
4
3
2
1
32
31
30
SELC1
5
29
SELB0
SELD0
6
28
GND
SELD1
7
27
SELA1
VCCQ
8
26
SELA0
VCCN
9
25
VCCN
QD1
10
24
QA0
QDO
11
23
QA1
GND
12
22
GND
GND
13
21
GND
VCCN
18
19
20
QB0
QC0
17
QB1
16
VCCN
15
FB_IN
14
QC1
XRK4991
2
xr
XRK4991
3.3V HIGH-SPEED (85 MHZ) PROGRAMMABLE SKEW CLOCK BUFFER
REV. 1.0.1
PIN DESCRIPTIONS
PIN NAME
PIN #
TYPE
DESCRIPTION
CLKIN
1
I
Reference clock input.
FB_IN
17
I
PLL’s feedback input. (Normally connected to one of the eight outputs)
FSEL
3
I
Tri-level frequency range select. See Table 1
PLL_BYPASS
31
I
Tri-level select. See PLL_BYPASS section.
SELA0
SELA1
26
27
I
Tri-level select inputs for Bank A outputs (QA0, QA1). See Table 2.
SELB0
SELB1
29
30
I
Tri-level select inputs for Bank B outputs (QB0, QB1). See Table 2.
SELC0
SELC1
4
5
I
Tri-level select inputs for Bank C outputs (QC0, QC1). See Table 2.
SELD0
SELD1
6
7
I
Tri-level select inputs for Bank D outputs (QD0, QD1). See Table 2.
QA0
QA1
24
23
O
Bank A output pair. See Table 2.
QB0
QB1
20
19
O
Bank B output pair. See Table 2.
QC0
QC1
15
14
O
Bank C output pair. See Table 2.
QD0
QD1
11
10
O
Bank D output pair. See Table 2.
VCCN
9
16
18
25
PWR
Power supply for output drivers.
VCCQ
2
8
PWR
Power supply for internal circuitry.
GND
12
13
21
22
28
32
PWR
Ground.
3
xr
XRK4991
3.3V HIGH-SPEED (85 MHZ) PROGRAMMABLE SKEW CLOCK BUFFER
REV. 1.0.1
TABLE 1: FREQUENCY RANGE SELECT AND tU CALCULATION [1]
fNOM (MHZ)
tU = 1 / (fNOM X N)
APPROXIMATE
FREQUENCY (MHZ) AT
FSEL[2]
MIN
MAX
LOW
15
30
44
22.7
MID
25
50
26
38.5
HIGH[3]
40
85
16
62.5
WHERE
N=
WHICH tU
= 1.0ns
SKEW SELECT CONTROL
The skew select control consists of four independent banks. Each bank has two low-skew, high-fanout drivers
(Qx0, Qx1), and two corresponding tri-level function select (SELx0, SELx1) inputs. The nine possible output
states for each bank are shown in Table 2 as determined by each bank’s select inputs. All timing
measurements are made with respect to the CLKIN input with the output connected to the FB_IN input
configured for 0 tU operation.
TABLE 2: PROGRAMMABLE SKEW CONFIGURATIONS [1]
FUNCTION SELECT INPUTS
OUTPUT FUNCTIONS
SELX1
SELX0
QA[1:0], QB[1:0]
QC[1:0]
QD[1:0]
LOW
LOW
-4tU
÷2
÷2
LOW
MID
-3tU
-6tU
-6tU
LOW
HIGH
-2tU
-4tU
-4tU
MID
LOW
-1tU
-2tU
-2tU
MID
MID
0tU
0tU
0tU
MID
HIGH
+1tU
+2tU
+2tU
HIGH
LOW
+2tU
+4tU
+4tU
HIGH
MID
+3tU
+6tU
+6tU
HIGH
HIGH
+4tU
÷4
Inverted
NOTES:
1. For all tri-level (three-state) inputs, HIGH indicates a connection to VCC, LOW indicates a connection to GND, and
MID indicates an open connection. Internal termination circuitry holds an unconnected input to VCC/2.
2. The level to be set on FSEL is determined by the “normal” operating frequency (fNOM) of the PLL. Nominal
frequency (fNOM) always appears at QA0 and the other outputs when they are operated in their undivided modes
(see Table 2). The frequency appearing at the CLKIN and FB_IN inputs will be fNOM when the output connected to
FB_IN is undivided. The frequency of the CLKIN and FB_IN inputs will be fNOM ÷ 2 or fNOM ÷ 4 when the part is
configured for a frequency multiplication.
3. When the FSEL pin is selected HIGH, the CLKIN input must not transition upon power-up until VCC has reached
2.8V.
4
xr
REV. 1.0.1
XRK4991
3.3V HIGH-SPEED (85 MHZ) PROGRAMMABLE SKEW CLOCK BUFFER
t0+6tU
t0+5tU
t0+4tU
t0+3tU
t0+2tU
t0+1tU
t0
t0-1tU
t0-2tU
t0-3tU
t0-4tU
t0-5tU
t0-6tU
FIGURE 3. TYPICAL OUTPUTS WITH FB_IN CONNECTED TO A ZERO-SKEW OUTPUT
FB_IN
SELA[1:0]
SELB[1:0]
(N/A)
LL
LM
LH
ML
MM
MH
HL
HM
HH
(N/A)
(N/A)
(N/A)
CLKIN
SELC[1:0]
SELD[1:0]
-6tU
LM
-4tU
LH
-3tU
(N/A)
-2tU
ML
-1tU
(N/A)
0tU
MM
+1tU
(N/A)
+2tU
MH
+3tU
(N/A)
+4tU
HL
+6tU
HM
LL/HH DIVIDED
HH(D)
INVERT
PLL_BYPASS
The PLL_BYPASS input is a tri-level input. In normal system operation, this pin is connected to ground.
In normal operation (tied LOW) all outputs will function based only on the connection of their own function
select inputs (SELx[1:0]) and the waveform characteristics of the PLL.
If the PLL_BYPASS input is forced to its MID or HIGH state the device will operate in PLL bypass mode, with
the phase locked loop disconnected, and CLKIN waveforms will directly control all outputs. Relative output to
output timing is controlled by the SELx[1:0], the same as in normal mode.
5
xr
XRK4991
3.3V HIGH-SPEED (85 MHZ) PROGRAMMABLE SKEW CLOCK BUFFER
REV. 1.0.1
ELECTRICAL SPECIFICATIONS
ABSOLUTE MAXIMUM RATINGS
Storage Temperature
–65°C to +150°C
Ambient Temperature with Power Applied
–55°C to +125°C
Supply Voltage to Ground Potential
–0.5V to +7.0V
DC Input Voltage
–0.5V to +7.0V
Output Current into Outputs (LOW)
64 mA
Static Discharge Voltage (per MIL-STD-883, Method 3015)
>3000V
Latch-Up Current.
>200 mA
OPERATING RANGE
RANGE
AMBIENT TEMPERATURE
VCC
Industrial
-40°C to +85°C
3.3 + 10%
Commercial
0°C to +70°C
3.3 + 10%
ELECTRICAL CHARACTERISTICS OVER THE 3.3V + 10% OPERATING RANGE
SYMBOL
DESCRIPTION
VOH
Output HIGH Voltage
VOL
Output LOW Voltage
VIH
Input HIGH Voltage
VIL
Input LOW Voltage
VIHH
MIN
MAX
2.4
tri-level Input HIGH Voltage
UNIT
CONDITION
V
VCC = Min., IOH = -18mA
0.45
V
VCC = Min., IOL = 35mA
2.0
VCC
V
(CLKIN and FB_IN inputs
only)
-0.5
0.8
V
0.87*VCC
VCC
V
Min. < VCC < Max.
0.47*VCC
0.53 * VCC
V
Min. < VCC < Max.
0.0
0.13 * VCC
V
Min. < VCC < Max.
20
µΑ
VCC = Max., VIN = Max.
µΑ
VCC = Max., VIN = 0.4V
200
µΑ
VIN = VCC
50
µA
VIN = VCC/2
-200
µA
VIN = GND
(FSEL, SELx[1:0], Test) [4]
VIMM
tri-level Input MID Voltage
(FSEL, SELx[1:0], Test)
VILL
[4]
tri-level Input LOW Voltage
(FSEL, SELx[1:0], Test)
[4]
IIH
Input HIGH Leakage Current
(CLKIN and FB_IN inputs only)
IIL
Input LOW Leakage Current
(CLKIN and FB_IN inputs only)
IIHH
Input HIGH Current
(FSEL, SELx[1:0], Test)
IIMM
Input MID Current
(FSEL, SELx[1:0], Test)
IILL
Input LOW Current
(FSEL, SELx[1:0], Test)
-20
-50
6
xr
XRK4991
3.3V HIGH-SPEED (85 MHZ) PROGRAMMABLE SKEW CLOCK BUFFER
REV. 1.0.1
ELECTRICAL CHARACTERISTICS OVER THE 3.3V + 10% OPERATING RANGE
SYMBOL
IOS
DESCRIPTION
MIN
Short Circuit Current [5]
MAX
UNIT
-200
mA
CONDITION
VCC = Max,
VOUT = GND (25° only)
ICCQ
ICCN
Operating Current Used by Internal Circuitry
Com’l
95
Ind
100
19
Output Buffer Current per Output Pair [6]
mA
VCCN = VCCQ = Max.,
All Inputs Selects Open
mA
VCCN = VCCQ = Max.,
IOUT = 0 mA
Inputs Selects Open, fMAX
PD
104
Power Dissipation per Output Pair [7]
mW
VCCN = VCCQ = Max.,
IOUT = 0 mA
Input Selects Open, fMAX
CAPACITANCE[8]
SYMBOL
CIN
DESCRIPTION
Input Capacitance
MAX.
UNIT
10
pF
CONDITION
TA = 25°C,
f=1MHz, VCC=3.3V
NOTES:
4. These inputs are normally wired to VCC, GND or left unconnected (actual threshold voltages vary as a percentage
of VCC). Internal termination resistors hold unconnected inputs at VCC/2. If these inputs are switched, the function
and timing of the outputs may glitch and the PLL may require an additional tLOCK time before all data sheet limits
are achieved.
5. XRK4991 should be tested one output at a time, output shorted for less than one second, less than 10% duty
cycle. Room temperature only.
6. Total output current per output pair can be approximated by the following expression that includes device current
plus load current:
XRK4991: ICCN = {(4+0.11F) + [(835-3F)/Z + (.0022FC)]N} x 1.1
Where:
F = frequency in MHz
C = capacitive load in pF
Z = line impedance in ohms
N = number of loaded outputs; 0, 1, or 2
7. Total power dissipation per output pair can be approximated by the following expression that includes device
power dissipation plus power dissipation due to the load circuit:
PD = {(22 + 0.61F) + [(1550 + 2.7F)/Z) + .0125FC]N} x 1.1
See note 6 for variable definition.
8. Applies to CLKIN and FB_IN inputs only.
7
xr
XRK4991
3.3V HIGH-SPEED (85 MHZ) PROGRAMMABLE SKEW CLOCK BUFFER
REV. 1.0.1
FIGURE 4. AC TEST LOAD
VCC
R1
CL
R2
LOAD
R1 = 100
R2 = 100
CL = 30pF
(Includes fixture and probe capacitances )
FIGURE 5. INPUT TEST WAVEFORM
3.0V
2.0V
2.0V
Vth = 1.5V
Vth = 1.5V
0.8V
0.8V
0.0V
<1ns
<1ns
SWITCHING CHARACTERISTICS OVER THE OPERATING RANGE [2,9]
SYMBOL
fNOM
DESCRIPTION
Operating Clock Frequency in MHz
MIN
MAX
UNIT
FSEL = LOW [1, 2]
15
30
MHz
FSEL = MID [1, 2]
25
50
FSEL = HIGH [1, 2, 3]
40
85
8
xr
XRK4991
3.3V HIGH-SPEED (85 MHZ) PROGRAMMABLE SKEW CLOCK BUFFER
REV. 1.0.1
SWITCHING CHARACTERISTICS OVER THE 3.3V + 10% OPERATING RANGE [2,9]
XRK4991-2
SYMBOL
XRK4991-5
XRK4991-7
DESCRIPTION
UNIT
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
tRPWH
CLKIN Pulse Width HIGH
4
4
4
ns
tRPWL
CLKIN Pulse Width LOW
4
4
4
ns
tu
Programmable Skew Unit
tSKEWPR
See Table 1
Zero Output Matched-Pair Skew
(Qx[1:0]) [10, 11]
0.05
0.2
0.1
0.25
0.1
0.25
ns
tSKEW0
Zero Output Skew (All Outputs) [10, 12]
0.1
0.25
0.25
0.5
0.3
0.75
ns
tSKEW1
Output Skew (Rise-Rise, Fall-Fall,
Same Class Outputs) [10, 13]
0.25
0.5
0.6
0.7
0.6
1
ns
tSKEW2
Output Skew (Rise-Fall, NominalInverted, Divided-Divided) [10, 13]
0.3
1
0.5
1
1
1.5
ns
tSKEW3
Output Skew (Rise-Rise, Fall-Fall,
Different Class Outputs) [10, 13]
0.25
0.5
0.5
0.7
0.7
1.2
ns
tSKEW4
Output Skew (Rise-Fall, NominalDivided, Divided-Inverted [10, 13]
0.5
0.9
0.5
1
1.2
1.7
ns
1.65
ns
tDEV
Device-to-Device Skew [14, 15]
0.75
1.25
tPD
Propagation Delay, CLKIN Rise to
FB_IN Rise
-0.25
0
0.25
-0.5
0
0.5
-0.7
0
0.7
ns
tODCV
Output Duty Cycle Variation [16]
-0.65
0
0.65
-1
0
1
-1.2
0
1.2
ns
tPWH
Output HIGH Time Deviation from 50%
2.0
2.5
3
ns
1.5
3
3.5
ns
[17]
tPWL
Output LOW Time Deviation from 50%
[17]
tORISE
Output Rise Time [17, 18]
0.15
1
1.2
0.15
1
1.5
0.15
1.5
2.5
ns
tOFALL
Output Fall Time [17, 18]
0.15
1
1.2
0.15
1
1.5
0.15
1.5
2.5
ns
tLOCK
PLL Lock Time [19]
tJR
Cycle-to-Cycle Output
Jitter
0.5
0.5
0.5
ms
RMS [14]
25
25
25
ps
Peak-to-Peak
200
200
200
[14]
NOTES:
9. Test measurement levels for the XRK4991 are TTL levels (1.5V to 1.5V). Test conditions assume signal transition
times of 2 ns or less and output loading as shown in the AC Test Loads and Waveforms unless otherwise
specified.
10. SKEW is defined as the time between the earliest and the latest output transition among all outputs for which the
same tU delay has been selected when all are loaded with 30pF and terminated with 50Ω to VCC/2 (XRK4991).
9
xr
XRK4991
3.3V HIGH-SPEED (85 MHZ) PROGRAMMABLE SKEW CLOCK BUFFER
REV. 1.0.1
11. tSKEWPR is defined as the skew between a pair of outputs (Qx0 and Qx1) when all eight outputs are selected for
0tU.
12. tSKEW0 is defined as the skew between outputs when they are selected for 0tU. Other outputs are divided or
inverted but not shifted
13. There are three classes of outputs: Nominal (multiple of tU delay), Inverted (QD[1:0] only with SELD0 = SELD1 =
HIGH), and Divided (QC[1:0] and QD[1:0] only in Divide-by-2 or Divide-by-4 mode).
14. Guaranteed by statistical correlation. Tested initially and after any design or process changes that may affect
these parameters.
15. tDEV is the output-to-output skew between any two devices operating under the same conditions (VCC ambient
temperature, air flow, etc.)
16. tODCV is the deviation of the output from a 50% duty cycle. Output pulse width variations are included in tSKEW2
and tSKEW4 specifications.
17. Specified with outputs loaded with 30pF for the XRK4991-5 and -7 devices. Devices are terminated through 50Ω
to VCC/2. tPWH is measured at 2.0V. tPWL is measured at 0.8V.
18. tORISE and tOFALL measured between 0.8V and 2.0V.
19. tLOCK is the time that is required before synchronization is achieved. This specification is valid only after VCC is
stable and within normal operating limits. This parameter is measured from the application of a new signal or
frequency at CLKIN or FB_IN until tPD is within specified limits
FIGURE 6. AC TIMING DIAGRAMS
tREF
tRPWH
tRPWL
CLKIN
tPD
tODCV
tODCV
FB_IN
tJR
Qxx output
tSKEWPR,
tSKEW0, 1
tSKEWPR,
tSKEW0, 1
Other Qxx output
tSKEW2
tSKEW2
Inverted Qxx output
tSKEW3, 4
tSKEW3, 4
tSKEW3, 4
CLKIN Divided by 2
tSKEW1, 3, 4
tSKEW2, 4
CLKIN Divided by 4
10
xr
XRK4991
3.3V HIGH-SPEED (85 MHZ) PROGRAMMABLE SKEW CLOCK BUFFER
REV. 1.0.1
PACKAGE DIMENSIONS
32 LEAD PLASTIC LEADED CHIP CARRIER
(PLCC)
Rev. 1.00
D
A1
D1
A2
30° x H1
2
1
32
45° x H2
B1
Corner Chamfer
E1
E3
B
E
D2
e
7°±2 deg typ.
C
R
D3
A
INCHES
MILLIMETERS
SYMBOL
MIN
MAX
MIN
MAX
A
0.120
0.140
3.05
3.56
A1
0.075
0.095
1.91
2.41
A2
0.020
--0.51
--B
0.013
0.021
0.33
0.53
B1
0.026
0.032
0.66
0.81
C
0.008
0.013
0.19
0.32
D
0.485
0.495
12.33
12.58
D1
0.448
0.454
11.39
11.54
D2
0.400
0.440
10.17
11.18
0.300 typ.
7.62 typ.
D3
E
0.585
0.595
14.87
15.11
E1
0.545
0.557
13.85
14.15
E2
0.500
0.540
12.71
13.72
0.400 typ.
10.16 typ.
E3
0.050 BSC
1.27 BSC
e
H1
0.023
0.029
0.58
0.74
H2
0.042
0.048
1.07
1.22
R
0.025
0.045
0.64
1.14
Note: The control dimension is in inches.
11
SEATING PLANE
XRK4991
3.3V HIGH-SPEED (85 MHZ) PROGRAMMABLE SKEW CLOCK BUFFER
xr
REV. 1.0.1
REVISION HISTORY
REVISION #
DATE
1.0.0
June 17, 2005
1.0.1
DESCRIPTION
Initial Release to Production
October 5, 2005 Product ordering information: Remove "F" product numbers and Lead Free column.
NOTICE
EXAR Corporation reserves the right to make changes to the products contained in this publication in order to
improve design, performance or reliability. EXAR Corporation assumes no responsibility for the use of any
circuits described herein, conveys no license under any patent or other right, and makes no representation that
the circuits are free of patent infringement. Charts and schedules contained here in are only for illustration
purposes and may vary depending upon a user’s specific application. While the information in this publication
has been carefully checked; no responsibility, however, is assumed for inaccuracies.
EXAR Corporation does not recommend the use of any of its products in life support applications where the
failure or malfunction of the product can reasonably be expected to cause failure of the life support system or
to significantly affect its safety or effectiveness. Products are not authorized for use in such applications unless
EXAR Corporation receives, in writing, assurances to its satisfaction that: (a) the risk of injury or damage has
been minimized; (b) the user assumes all such risks; (c) potential liability of EXAR Corporation is adequately
protected under the circumstances.
Copyright 2005 EXAR Corporation
Datasheet October 2005.
Reproduction, in part or whole, without the prior written consent of EXAR Corporation is prohibited.
12