INTERSIL ZL2106ALCNT

ZL2106
Features
The ZL2106 is an innovative power conversion and
management IC that combines an integrated
synchronous step-down DC/DC converter with key power
management functions in a small package, resulting in a
flexible and integrated solution.
•
•
•
•
•
•
The ZL2106 can provide an output voltage from 0.54V to
5.5V (with margin) from an input voltage between 4.5V
and 14V. Internal low rDS(ON) synchronous power
MOSFETs enable the ZL2106 to deliver continuous loads
up to 6A with high efficiency. An internal Schottky
bootstrap diode reduces discrete component count. The
ZL2106 also supports phase spreading to reduce system
input capacitance.
Power management features such as digital soft-start
delay and ramp, sequencing, tracking, and margining
can be configured by simple pin-strapping or through an
on-chip serial port. The ZL2106 uses the PMBus™
protocol for communication with a host controller and the
Digital-DC bus for interoperability between other Zilker
Labs devices.
Integrated MOSFET switches
6A continuous output current
±1% output voltage accuracy
Snapshot™ parametric capture
I2C/SMBus interface, PMBus compatible
Internal non-volatile memory (NVM)
Applications*(see page 28)
•
•
•
•
Telecom, Networking, Storage equipment
Test and Measurement equipment
Industrial control equipment
5V and 12V distributed power systems
Related Literature*(see page 28)
• See AN1468 “ZL2106EVAL1Z Evaluation Board”, USB
Adapter Board, GUI Software
• See AN2010 “Thermal and Layout Guidelines for
Digital-DC™ Products”
• See AN2033 “Zilker Labs PMBus Command Set-DDC
ProductsPMBus Command Set”
• See AN2035 “Compensation Using CompZL™”
100
VOUT = 3.3V
EFFICIENCY (%)
90
80
70
60
VIN = 12V
fSW = 200kHz
L = 6µH
50
40
0.0
1.0
2.0
3.0
4.0
5.0
6.0
IOUT (A)
FIGURE 1. ZL2106 EFFICIENCY
February 11, 2010
FN6852.2
1
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 1-888-468-3774 | Intersil (and design) is a registered trademark of Intersil Americas Inc.
Copyright Intersil Americas Inc. 2009, 2010. All Rights Reserved
All other trademarks mentioned are the property of their respective owners.
ZL2106
6A Digital-DC Synchronous Step-Down DC/DC
Converter
ZL2106
Typical Application Circuit
The following application circuit represents a typical
implementation of the ZL2106. For PMBus operation, it is
recommended to tie the enable pin (EN) to SGND.
C RA
4.7 µF
VDDP 29
C IN
100 µF
VDDP 27
2 DGND
BST 26
3 SYNC
SW 25
SW 24
4 VSET
ZL2106
5 SA
I2C/
SMBus ††
SW 23
6 SCL
SW 22
7 SDA
SW 21
SW 20
CB
47nF
LOUT
2.2µH
VOUT
3.3V
C OUT
150 µF
18 PGND
17 PG ND
PGND 19
16 PGND
15 PGND
13 VSEN
12 VTRK
11 SS
10 CFG
e PAD
(SG ND)
14 SGND
8 SALRT
9 FC
VIN
12V
C DD
2.2 µF
VDDP 28
VR 31
1 PG
VDDS 30
VRA 32
DDC 34
V2P5 33
EN 36
PGOOD
MGN 35
DDC Bus
ENABLE
‡
CR
4.7µF
C 25
10 µF
†
F.B.
Notes:
‡
Ferrite bead is optional for input noise suppression.
†
The DDC bus pull-up resistance will vary based on the capacitive loading of the bus, including the number of devices
connected. The 10 kΩ default value, assuming a maximum of 100 pF per device, provides the necessary 1 µs pull-up rise
time. Please refer to the Digital-DC Bus section for more details.
††
2
The I C/SMBus pull -up resistance will vary based on the capacitive loading of the bus, including the number of devices
connected. Please refer to the I2 C/SMBus specifications for more details.
FIGURE 2. 12V TO 3.3V/6A APPLICATION CIRCUIT (5ms SS DELAY, 5ms SS RAMP)
Block Diagram
2.5V
LDO
5V
LDO
7V
LDO
VDDP
VDDS
VR
EN
VRA
V2P5
VIN
BST
PG
Power
Mgmt
VTRK
SMBus
SW
VOUT
VSEN
NVM
SYNC
SALRT
SA
SCL
DDC Bus
SDA
DDC
PWM
Control
&
Drivers
PGND
MGN
VSET
CFG
SS
FIGURE 3. BLOCK DIAGRAM
2
FN6852.2
February 11, 2010
ZL2106
Pin Configuration
28
29
30
31
32
33
34
1
27
2
26
3
25
4
24
ZL2106
5
23
6
22
7
Exposed Paddle
8
Connect to SGND
21
20
18
17
16
15
14
13
VDDP
BST
SW
SW
SW
SW
SW
SW
PGND
CFG
SS
VTRK
VSEN
SGND
PGND
PGND
PGND
PGND
12
19
11
9
10
PG
DGND
SYNC
VSET
SA
SCL
SDA
SALRT
FC
35
36
EN
MGN
DDC
V2P5
VRA
VR
VDDS
VDDP
VDDP
ZL2106
(36 LD QFN)
TOP VIEW
FIGURE 4.
Pin Descriptions
PIN
LABEL
TYPE
(Note 1)
1
PG
O
Power-good. This pin transitions high 100ms after output voltage stabilizes within
regulation band. Selectable open drain or push-pull output. Factory default is open drain.
2
DGND
PWR
Digital ground. Common return for digital signals. Connect to low impedance ground plane.
3
SYNC
I/O, M
(Note 2)
4
VSET
I, M
Output voltage select pin. Used to set VOUT set-point and VOUT max.
5
SA
I, M
Serial address select pin. Used to assign unique SMBus address to each IC.
6
SCL
I/O
Serial clock. Connect to external host interface.
7
SDA
I/O
Serial data. Connect to external host interface.
8
SALRT
O
9
FC
I, M
Loop compensation select pin. Used to set loop compensation.
10
CFG
I, M
Configuration pin. Used to control the SYNC pin, sequencing and enable tracking.
11
SS
I, M
Soft-start pin. Used to set the ramp delay and ramp time, sets UVLO and configure
tracking.
12
VTRK
I
Track sense pin. Used to track an external voltage source.
13
VSEN
I
Output voltage positive feedback sensing pin.
14
SGND
PWR
Common return for analog signals. Connect to low impedance ground plane.
15, 16, 17,
18, 19
PGND
PWR
Power ground. Common return for internal switching MOSFETs. Connect to low impedance
ground plane.
20, 21, 22,
23, 24, 25
SW
I/O
26
BST
PWR
Bootstrap voltage for level-shift driver (referenced to SW).
27, 28, 29
VDDP
PWR
Bias supply voltage for internal switching MOSFETs (return is PGND).
30
VDDS
PWR
IC supply voltage (return is SGND).
3
DESCRIPTION
Clock synchronization pin. Used to set switching frequency of internal clock or for
synchronization to external frequency reference.
Serial alert. Connect to external host interface if desired.
Switching node (level-shift common).
FN6852.2
February 11, 2010
ZL2106
Pin Descriptions (Continued)
PIN
LABEL
TYPE
(Note 1)
31
VR
PWR
Regulated bias from internal 7V low-dropout regulator (return is PGND). Decouple with a
4.7µF capacitor to PGND.
32
VRA
PWR
Regulated bias from internal 5V low-dropout regulator for internal analog circuitry (return
is SGND). Decouple with a 4.7µF capacitor to SGND.
33
V2P5
PWR
Regulated bias from internal 2.5V low-dropout regulator for internal digital circuitry (return
is DGND). Decouple with a 10µF capacitor.
34
DDC
I/O
35
MGN
I
Margin pin. Used to enable margining of the output voltage.
36
EN
I
Enable pin. Used to enable the device (active high).
ePad
SGND
PWR
DESCRIPTION
Digital-DC Bus (open drain). Interoperability between Zilker Labs devices.
Exposed thermal pad. Common return for analog signals. Connect to low impedance
ground plane.
NOTES:
1. I = Input, O = Output, PWR = Power or Ground, M = Multi-mode pins. Please refer to Section “Multi-mode Pins” on page 12.
2. The SYNC pin can be used as a logic pin, a clock input or a clock output.
Ordering Information
PART NUMBER
(Notes 2, 3)
PART
MARKING
TEMP RANGE
(°C)
PACKAGE
PKG.
DWG. #
ZL2106ALCN
2106
-40 to +85
36 Ld 6mmx6mm QFN
L36.6x6A
ZL2106ALCNT (Note 1)
2106
-40 to +85
36 Ld 6mmx6mm QFN
L36.6x6A
ZL2106ALCNTK (Note 1)
2106
-40 to +85
36 Ld 6mmx6mm QFN
L36.6x6A
ZL2106EVAL1Z
Evaluation Board
NOTES:
1. Please refer to TB347 for details on reel specifications.
2. These Intersil Pb-free plastic packaged products employ special Pb-free material sets; molding compounds/die attach
materials and NiPdAu plate - e4 termination finish, which is RoHS compliant and compatible with both SnPb and Pb-free
soldering operations. Intersil Pb-free products are MSL classified at Pb-free peak reflow temperatures that meet or exceed
the Pb-free requirements of IPC/JEDEC J STD-020.
3. For Moisture Sensitivity Level (MSL), please see device information page for ZL2106. For more information on MSL please see
techbrief TB363.
4
FN6852.2
February 11, 2010
ZL2106
Table of Contents
Typical Application Circuit .............................. 2
Block Diagram ................................................ 2
Pin Configuration ............................................ 3
Pin Descriptions ............................................. 3
Ordering Information ..................................... 4
Absolute Maximum Ratings ............................ 6
Thermal Information ...................................... 6
Recommended Operating Conditions .............. 6
Electrical Specifications .................................. 6
Typical Performance Curves ............................ 9
ZL2106 Overview ............................................ 10
Digital-DC Architecture ..................................... 10
Power Conversion Overview .............................. 10
Power Management Overview ............................ 12
Multi-mode Pins ............................................... 12
Power Conversion Functional Description ....... 13
Internal Bias Regulators and Input Supply
Connections .................................................. 13
High-side Driver Boost Circuit ............................ 13
Output Voltage Selection ................................... 13
Start-up Procedure ........................................... 14
Soft-start Delay and Ramp Times ....................... 14
Power-good (PG) ............................................. 16
Switching Frequency and PLL ............................. 16
5
Component Selection .......................................
Current Sensing and Current Limit Threshold
Selection ......................................................
Loop Compensation .........................................
Driver Dead-time Control .................................
17
19
19
20
Power Management Functional Description .... 20
Input Undervoltage Lockout ..............................
Output Overvoltage Protection ..........................
Output Pre-Bias Protection ................................
Output Overcurrent Protection ..........................
Thermal Overload Protection .............................
Voltage Tracking .............................................
Voltage Margining ...........................................
I2C/SMBus Communications .............................
I2C/SMBus Device Address Selection .................
Digital-DC Bus ................................................
Phase Spreading .............................................
Output Sequencing ..........................................
Fault Spreading ...............................................
Monitoring via I2C/SMBus .................................
Snapshot™ Parametric Capture .........................
Non-Volatile Memory and Device Security
Features .......................................................
20
21
21
21
22
22
23
24
24
24
25
25
26
26
26
26
Revision History ............................................. 27
Products ......................................................... 28
Package Outline Drawing ............................... 29
FN6852.2
February 11, 2010
ZL2106
Absolute Maximum Ratings
Thermal Information
DC Supply Voltage for VDDP, VDDS Pins . . . . . . -0.3V to 17V
High-Side Supply Voltage for BST Pin . . . . . . . . -0.3V to 30V
High-Side Boost Voltage for BST - SW Pins . . . . . -0.3V to 8V
Internal MOSFET Reference for VR Pin . . . . . . -0.3V to 8.5V
Internal Analog Reference for VRA Pin . . . . . . -0.3V to 6.5V
Internal 2.5 V Reference for V2P5 Pin . . . . . . . . . -0.3V to 3V
Logic I/O Voltage for EN, CFG, DDC, FC, MGN, PG, SDA, SCL,
SA, SALRT, SS, SYNC, VTRK, VSET, VSEN Pins -0.3V to 6.5V
Ground Differential for DGND - SGND,
PGND - SGND Pins . . . . . . . . . . . . . . . . . . . . . . ±0.3V
MOSFET Drive Reference Current for for VR Pin
Internal Bias Usage . . . . . . . . . . . . . . . . . . . . . . . . 20mA
Switch Node Current for SW Pin
Peak (Sink Or Source) . . . . . . . . . . . . . . . . . . . . . . . 10A
ESD Rating
Human Body Model . . . . . . . . . . . . . . . . . . . . . . . . . 2kV
Machine Model . . . . . . . . . . . . . . . . . . . . . . . . . . . 500V
Thermal Resistance (Typical)
θJA (°C/W) θJC (°C/W)
36 Ld QFN (Notes 4, 5) . . . . . . . . .
28
1
Junction Temperature Range . . . . . . . . . . -55°C to +150°C
Storage Temperature Range . . . . . . . . . . . -55°C to +150°C
Dissipation Limits (Note 6)
TA = +25°C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5W
TA = +55°C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5W
TA = +85°C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4W
Pb-Free Reflow Profile . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
Recommended Operating Conditions
Input Supply Voltage Range, VDDP, VDDS
VDDS tied to VR, VRA . . . . . . . . . . . . .
VDDS tied to VR, VRA Floating . . . . . . .
VR, VRA Floating . . . . . . . . . . . . . . . .
Output Voltage Range, VOUT (Note 7) . . .
Operating Junction Temperature Range, TJ .
(See Figure 14)
. . . . . 4.5V to 5.5V
. . . . . 5.5V to 7.5V
. . . . . 7.5V to 14V
. . . . 0.54V to 5.5V
. -40°C to +125°C
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact
product reliability and result in failures not covered by warranty.
NOTES:
4. θJA is measured in free air with the component mounted on a high effective thermal conductivity test board with “direct attach”
features. See Tech Brief TB379.
5. For θJC, the “case temp” location is the center of the exposed metal pad on the package underside.
6. Thermal impedance depends on layout.
7. Includes margin limits.
Electrical Specifications VDDP = VDDS = 12V, TA = -40°C to +85°C unless otherwise noted. (Note 8) Typical values are
at TA = +25°C. Boldface limits apply over the operating temperature range, -40°C to
+85°C.
MIN
(Note 18)
TYP
MAX
(Note 18)
UNIT
fSW = 200kHz, no load
-
11
20
mA
fSW = 1MHz, no load
-
15
30
mA
IDDS Shutdown Current
EN = 0V, No I2C/SMBus activity
-
0.6
1
mA
VR Reference Output Voltage
VDD > 8V, IVR < 10mA
6.5
7.0
7.5
V
VRA Reference Output Voltage
VDD > 5.5V, IVRA < 20mA
4.5
5.1
5.5
V
V2P5 Reference Output Voltage
IV2P5 < 20mA
2.25
2.5
2.75
V
-
-
6
A
0.6
-
5.0
V
PARAMETER
CONDITIONS
Input and Supply Characteristics
IDD Supply Current
Output Characteristics
Output Current
IRMS, Continuous
Output Voltage Adjustment Range (Note 9)
VIN > VOUT
Output Voltage Setpoint Resolution
Set using resistors
-
10
-
mV
Set using I2C/SMBus
-
±0.025
-
% FS
(Note 10)
-1
-
1
%
Vsen Output Voltage Accuracy
Includes line, load, temp
Vsen Input Bias Current
VSEN = 5.5V
-
110
200
µA
Soft-start Delay Duration Range (Note 11)
Set using SS pin or resistor
(Note 19)
2
-
20
ms
0.002
-
500
s
Set using I2C/SMBus (Note 19)
6
FN6852.2
February 11, 2010
ZL2106
Electrical Specifications VDDP = VDDS = 12V, TA = -40°C to +85°C unless otherwise noted. (Note 8) Typical values are
at TA = +25°C. Boldface limits apply over the operating temperature range, -40°C to
+85°C. (Continued)
PARAMETER
Soft-start Delay Duration Accuracy
Soft-start Ramp Duration Range
MIN
(Note 18)
TYP
MAX
(Note 18)
UNIT
Turn-on delay (precise mode)
(Notes 11, 12)
-
±0.25
-
ms
Turn-on delay (normal mode)
(Note 13)
-
-0.25/+4
-
ms
Turn-off delay (Note 13)
-
-0.25/+4
-
ms
Set using SS pin or resistor
(Note 19)
2
-
20
ms
Set using I2C/SMBus (Note 19)
0
-
200
ms
-
100
–
µs
-250
-
250
nA
-
-
0.8
V
-
1.4
-
V
2.0
-
-
V
-
-
0.4
V
2.25
-
-
V
-
-
9
A
200
-
1000
kHz
-5
-
5
%
-
-
95
(Note 16)
%
150
-
-
ns
CONDITIONS
Soft-start Ramp Duration Accuracy
Logic Input/output Characteristics
Logic Input Leakage Current
Digital pins
Logic input low, VIL
Logic input OPEN (N/C)
Multi-mode logic pins
Logic Input High, VIH
Logic Output Low, VOL
IOL ≤ 4mA
Logic Output High, VOH
IOH ≥ -2mA
Oscillator and Switching Characteristics
Switch Node Current, ISW
Peak (source or sink) (Note 14)
Switching Frequency Range
Switching Frequency Set-point Accuracy
Predefined settings (Table 9)
PWM Duty Cycle (max)
Factory default (Note 15)
SYNC Pulse Width (min)
Input Clock Frequency Drift Tolerance
External clock source (Note 19)
-13
-
13
%
rDS(ON) of High Side N-channel FETs
ISW = 6A, VGS = 6.5V (Note 19)
-
60
85
mΩ
rDS(ON) of Low Side N-channel FETs
ISW = 6A, VGS = 12V (Note 19)
-
43
65
mΩ
VTRK Input Bias Current
VTRK = 5.5V
-
110
200
µA
VTRK Tracking Ramp Accuracy
100% Tracking, VOUT - VTRK
(Note 19)
-100
-
100
mV
VTRK Regulation Accuracy
100% Tracking, VOUT - VTRK
-1
-
1
%
Configurable via I2C/SMBus
2.85
-
16
V
-150
-
150
mV
-
3
-
%
0
-
100
%
-
-
2.5
µs
Tracking
Fault Protection Characteristics
UVLO Threshold Range
UVLO Set-point Accuracy
UVLO Hysteresis
Factory default
Configurable via
(Note 19)
UVLO Delay
I2C/SMBus
Power-good VOUT Threshold
Factory default
-
90
-
% VOUT
Power-good VOUT Hysteresis
Factory default
-
5
-
%
7
FN6852.2
February 11, 2010
ZL2106
Electrical Specifications VDDP = VDDS = 12V, TA = -40°C to +85°C unless otherwise noted. (Note 8) Typical values are
at TA = +25°C. Boldface limits apply over the operating temperature range, -40°C to
+85°C. (Continued)
MIN
(Note 18)
TYP
MAX
(Note 18)
UNIT
Using pin-strap or resistor
(Note 19)
2
-
20
ms
Configurable via I2C/SMBus
(Note 19)
0
-
500
s
Factory default
-
85
-
% VOUT
Configurable via I2C/SMBus
(Note 19)
0
-
110
% VOUT
Factory default
-
115
-
% VOUT
0
-
115
% VOUT
-
5
-
% VOUT
Factory default
-
16
-
µs
Configurable via I2C/SMBus
(Note 19)
5
-
60
µs
Factory default
-
-
9.0
A
0.2
-
9.0
A
-
±10
-
% FS
(Note 10)
Factory default
-
5
-
tSW
(Note 17)
Configurable via I2C/SMBus
(Note 19)
1
-
32
tSW
(Note 17)
Factory default
-
125
-
°C
-40
-
125
°C
-
15
-
°C
PARAMETER
Power-good Delay
VSEN Undervoltage Threshold
VSEN Overvoltage Threshold
CONDITIONS
Configurable via
(Note 19)
I2C/SMBus
VSEN Undervoltage Hysteresis
VSEN Undervoltage/Overvoltage Fault
Response Time
Peak Current Limit Threshold
Configurable via
(Note 19)
I2C/SMBus
Current Limit Set-point Accuracy
Current Limit Protection Delay
Thermal Protection Threshold (Junction
Temperature)
Configurable via
I2C/SMBus
Thermal Protection Hysteresis
NOTES:
8. Refer to Safe Operating Area in Figure 8 and thermal design guidelines in AN2010.
9. Does not include margin limits.
10. Percentage of Full Scale (FS) with temperature compensation applied.
11. The device requires a delay period following an enable signal and prior to ramping its output. Precise timing mode limits this
delay period to approx 2ms, where in normal mode it may vary up to 4ms.
12. Precise ramp timing mode is only valid when using EN pin to enable the device rather than PMBus enable. Precise ramp timing
mode is automatically disabled for a self-enabled device (EN pin tied high).
13. The devices may require up to a 4ms delay following the assertion of the enable signal (normal mode) or following the
de-assertion of the enable signal. Precise mode requires Re-Enable delay = TOFF+TFALL+10µs.
14. Switch node current should not exceed IRMS of 6A.
15. Factory default is the initial value in firmware. The value can be changed via PMBus commands.
16. Maximum duty cycle is limited by the equation MAX_DUTY(%) = [1 - (150×10-9 × fSW)] × 100 and not to exceed 95%.
17. tSW = 1/fSW, where fSW is the switching frequency.
18. Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established
by characterization and are not production tested.
19. Limits established by characterization and are not production tested.
8
FN6852.2
February 11, 2010
ZL2106
Typical Performance Curves
For some applications, ZL2106 operating conditions (input voltage,
output voltage, switching frequency, temperature) may require
de-rating to remain within the Safe Operating Area (SOA).
1.4
1.4
1.3
1.3
NORMALIZED rDS(ON)
NORMALIZED rDS(ON)
VIN = VDDP = VDDS, TJ = +125°C
1.2
1.1
1.0
0.9
0.8
0
25
50
75
1.2
1.1
1.0
0.9
0.8
100
0
25
TJ (°C)
70
6
65
5
100
VIN = 7.5V
VIN = 6V
4
TJ = +110°C
VOUT (V)
rDS(ON) (mΩ)
75
FIGURE 6. HIGH-SIDE rDS(ON) vs TJ NORMALIZED
FOR TJ = +25°C (VDDS = 12V,
BST – SW = 6.5V, IDRAIN = 0.3A)
FIGURE 5. LOW-SIDE rDS(ON) vs TJ NORMALIZED
FOR TJ = +25°C (VDDS = 12V,
IDRAIN = 0.3A)
60
50
TJ (°C)
55
TJ = +80°C
50
3
VIN = 8.6V TO 14V
2
TJ = +50°C
45
40
1
TJ = +25°C
6
7
8
9
10
11
12
0
13
0.2
0.3
0.4
VDDS (V)
0.6
0.7
0.8
0.9
1
1.0
fSW (MHz)
FIGURE 7. LOW-SIDE rDS(ON) vs VDDS WITH TJ
FIGURE 8. SAFE OPERATING AREA, TJ ≤ +125°C
0.95
VOUT MAY NOT EXCEED
5.5V AT ANY TIME
0.90
VOUT/VIN (V)
0.5
0.85
0.80
0.75
0.70
0.65
0.60
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
fSW (MHz)
FIGURE 9. MAXIMUM CONVERSION RATIO, TJ ≤ +125°C
9
FN6852.2
February 11, 2010
ZL2106
ZL2106 Overview
Digital-DC Architecture
The ZL2106 is an innovative mixed-signal power
conversion and power management IC based on Zilker
Labs patented Digital-DC technology that provides an
integrated, high performance step-down converter for
point of load applications. The ZL2106 integrates all
necessary PWM control circuitry as well as low rDS(ON)
synchronous power MOSFETs to provide an extremely
small solution for supplying load currents up to 6A.
Its unique PWM loop utilizes an ideal mix of analog and
digital blocks to enable precise control of the entire
power conversion process with no software required,
resulting in a very flexible device that is also very easy to
use. An extensive set of power management functions
are fully integrated and can be configured using simple
pin connections. The user configuration can be saved in
an internal non-volatile memory (NVM). Additionally, all
functions can be configured and monitored via the
SMBus hardware interface using standard PMBus
commands, allowing ultimate flexibility.
Once enabled, the ZL2106 is immediately ready to
regulate power and perform power management tasks
with no programming required. Advanced configuration
options and real-time configuration changes are available
via the I2C/SMBus interface if desired and continuous
monitoring of multiple operating parameters is possible
with minimal interaction from a host controller.
Integrated sub-regulation circuitry enables single supply
operation from any external supply between 4.5V and
14V with no secondary bias supplies needed. The ZL2106
can also be configured to operate from a 3.3V or 5V
standby supply when the main power rail is not present,
allowing the user to configure and/or read diagnostic
information from the device when the main power has
been interrupted or is disabled.
The ZL2106 can be configured by simply connecting its
pins according to the tables provided in the following
sections. Additionally, a comprehensive set of application
notes are available to help simplify the design process.
An evaluation board is also available to help the user
become familiar with the device. This board can be
evaluated as a standalone platform using pin
configuration settings. A Windows™-based GUI is also
provided to enable full configuration and monitoring
capability via the I2C/SMBus interface using an available
computer and the included USB cable.
Power Conversion Overview
The ZL2106 operates as a voltage-mode, synchronous
buck converter with a selectable constant frequency
pulse width modulator (PWM) control scheme. The
ZL2106 integrates dual low rDS(ON) synchronous
MOSFETs to minimize the circuit footprint.
Figure 10 illustrates the basic synchronous buck
converter topology showing the primary power train
components. This converter is also called a step-down
converter, as the output voltage must always be lower
than the input voltage.
VIN
CIN
LDO
DB
QH
CB
L1
VOUT
PWM
QL
COUT
ZL
FIGURE 10. SYNCHRONOUS BUCK CONVERTER
10
FN6852.2
February 11, 2010
ZL2106
INPUT VOLTAGE BUS
VTRK
VSET
POWER MANAGEMENT
DIGITAL
DIGITAL
COMPENSATOR
COMPENSATOR
FC
BST
LDO
NVM
ISENSE
HS FET
DRIVER
D-PWM
SYNC
GEN
SYNC
VDDP
SS
VDDS
EN MGN CFG
PG
>
VRA
VR
>
SW
VOUT
LS FET
DRIVER
PLL
Σ
ADC
-
+
ISENSE
ADC
RESET
REF
DDC
SALRT
SDA
SCL
SA
VDD
ADC
VSEN
MUX
COMMUNICATION
TEMP
SENSOR
FIGURE 11. ZL2106 BLOCK DIAGRAM
VOUT
VIN
(EQ. 1)
During time D, QH is on and VIN – VOUT is applied across
the inductor. The output current ramps up as shown in
Figure 12.
When QH turns off (time 1-D), the current flowing in the
inductor must continue to flow from the ground up
through QL, during which the current ramps down. Since
the output capacitor COUT exhibits low impedance at the
switching frequency, the AC component of the inductor
current is filtered from the output voltage so the load
sees nearly a DC voltage.
VIN - VOUT
IL PK
IO
0
Current (A)
D≈
The maximum conversion ratio is shown in Figure 9.
Typically, buck converters specify a maximum duty cycle
that effectively limits the maximum output voltage that
can be realized for a given input voltage and switching
frequency. This duty cycle limit ensures that the low-side
MOSFET is allowed to turn on for a minimum amount of
time during each switching cycle, which enables the
bootstrap capacitor to be charged up and provide
adequate gate drive voltage for the high-side MOSFET.
Voltage
(V)
The ZL2106 integrates two N-channel power MOSFETs;
QH is the top control MOSFET and QL is the bottom
synchronous MOSFET. The amount of time that QH is on
as a fraction of the total switching period is known as the
duty cycle D, which is described by Equation 1:
ILV
-VOUT
D
1-D
Time
FIGURE 12. INDUCTOR WAVEFORM
11
FN6852.2
February 11, 2010
ZL2106
In general, the size of components L1 and COUT as well as
the overall efficiency of the circuit are inversely
proportional to the switching frequency, fSW. Therefore,
the highest efficiency circuit may be realized by switching
the MOSFETs at the lowest possible frequency; however,
this will result in the largest component size. Conversely,
the smallest possible footprint may be realized by
switching at the fastest possible frequency but this gives
a somewhat lower efficiency. Each user should determine
the optimal combination of size and efficiency when
determining the switching frequency for each application.
The block diagram for the ZL2106 is illustrated in
Figure 11. In this circuit, the target output voltage is
regulated by connecting the VSEN pin directly to the
output regulation point. The VSEN signal is then
compared to an internal reference voltage that had been
set to the desired output voltage level by the user. The
error signal derived from this comparison is converted to
a digital value with an analog to digital (A/D) converter.
The digital signal is also applied to an adjustable digital
compensation filter and the compensated signal is used
to derive the appropriate PWM duty cycle for driving the
internal MOSFETs in a way that produces the desired
output.
Power Management Overview
The ZL2106 incorporates a wide range of configurable
power management features that are simple to
implement without additional components. Also, the
ZL2106 includes circuit protection features that
continuously safeguard the device and load from damage
due to unexpected system faults. The ZL2106 can
continuously monitor input voltage, output
voltage/current and internal temperature. A Power-good
output signal is also included to enable power-on reset
functionality for an external processor.
All power management functions can be configured using
either pin configuration techniques (see Figure 13) or via
the I2C/SMBus interface. Monitoring parameters can also
be pre-configured to provide alerts for specific
conditions. See Application Note AN2033 for more details
on SMBus monitoring.
Multi-mode Pins
In order to simplify circuit design, the ZL2106
incorporates patented multi-mode pins that allow the
user to easily configure many aspects of the device
without programming. Most power management features
can be configured using these pins. The multi-mode pins
can respond to four different connections, as shown in
Table 1. These pins are sampled when power is applied or
by issuing a PMBus Restore command (See Application
Note AN2033).
PIN-STRAP SETTINGS
This is the simplest method, as no additional components
are required. Using this method, each pin can take on
one of three possible states: LOW, OPEN, or HIGH. These
pins can be connected to the V2P5 pin for logic HIGH
settings as this pin provides a regulated voltage higher
12
than 2V. Using a single pin one of three settings can be
selected.
TABLE 1. MULTI-MODE PIN CONFIGURATION
PIN TIED TO
VALUE
LOW
(Logic LOW)
< 0.8VDC
OPEN
(N/C)
No connection
HIGH
(Logic HIGH)
> 2.0VDC
Resistor to SGND
Set by resistor value
Logic
high
Open
ZL
ZL
Multi- mode Pin
Multi- mode Pin
RSET
Logic
low
Pinstrap
Settings
Resistor
Settings
FIGURE 13. PIN-STRAP AND RESISTOR SETTING
EXAMPLES
RESISTOR SETTINGS
This method allows a greater range of adjustability when
connecting a finite value resistor (in a specified range)
between the multi-mode pin and SGND.
Standard 1% resistor values are used, and only every
fourth E96 resistor value is used so the device can
reliably recognize the value of resistance connected to
the pin while eliminating the error associated with the
resistor accuracy. Up to 31 unique selections are
available using a single resistor.
I2C/SMBUS METHOD
ZL2106 functions can be configured via the I2C/SMBus
interface using standard PMBus commands. Additionally,
any value that has been configured using the pin-strap or
resistor setting methods can also be re-configured
and/or verified via the I2C/SMBus. See Application Note
AN2033 for more details.
The SMBus device address and VOUT_MAX are the only
parameters that must be set by external pins. All other
device parameters can be set via the I2C/SMBus. The
device address is set using the SA pin. VOUT_MAX is
determined as 10% greater than the voltage set by the
VSET pin.
Resistor pin-straps are recommended to be used for all
available device parameters to allow a safe initial powerup before configuration is stored via the I2C/SMBus. For
example, this can be accomplished by pin-strapping the
undervoltage lockout threshold (using SS pin) to a value
greater than the expected input voltage, thus preventing
the device from enabling prior to loading a configuration
file.
FN6852.2
February 11, 2010
ZL2106
Power Conversion Functional
Description
Internal Bias Regulators and Input Supply
Connections
The ZL2106 employs three internal low dropout (LDO)
regulators to supply bias voltages for internal circuitry,
allowing it to operate from a single input supply. The
internal bias regulators are as follows:
• VR: The VR LDO provides a regulated 7V bias supply
for the high-side MOSFET driver circuit. It is powered
from the VDDS pin and supplies bias current
internally. A 4.7µF filter capacitor is required at the
VR pin. The VDDS pin directly supplies the low-side
MOSFET driver circuit.
• VRA: The VRA LDO provides a regulated 5V bias
supply for the current sense circuit and other analog
circuitry. It is powered from the VDDS pin and
supplies bias current internally. A 4.7µF filter
capacitor is required at the VRA pin.
VIN
VIN
VIN
VDDS
VDDS
VDDS
VR
VR
VR
VRA
VRA
VRA
4.5V ≤ VIN ≤ 5.5V
5.5V < V IN ≤ 7.5V
7.5V < V IN ≤ 14V
FIGURE 14. INPUT SUPPLY CONNECTIONS
• V2P5:The V2P5 LDO provides a regulated 2.5V bias
supply for the main controller circuitry. It is powered
from the VRA LDO and supplies bias current
internally. A 10µF filter capacitor is required at the
V2P5 pin.
13
When the input supply (VDDS) is higher than 7.5V, the
VR and VRA pins should not be connected to any other
pins. These pins should only have a filter capacitor
attached. Due to the dropout voltage associated with the
VR and VRA bias regulators, the VDDS pin must be
connected to these pins for designs operating from a
supply below 7.5V. Figure 14 illustrates the required
connections for all cases.
Note: The internal bias regulators, VR and VRA, are not
designed to be outputs for powering other circuitry. Do
not attach external loads to any of these pins. Only the
multi-mode pins may be connected to the V2P5 pin for
logic HIGH settings.
High-side Driver Boost Circuit
The gate drive voltage for the high-side MOSFET driver is
generated by a floating bootstrap capacitor, CB (see
Figure 10). When the lower MOSFET (QL) is turned on,
the SW node is pulled to ground and the capacitor is
charged from the internal VR bias regulator through
diode DB. When QL turns off and the upper MOSFET (QH)
turns on, the SW node is pulled up to VDDP and the
voltage on the bootstrap capacitor is boosted
approximately 6.5V above VDDP to provide the
necessary voltage to power the high-side driver. An
internal Schottky diode is used with CB to help maximize
the high-side drive supply voltage.
Output Voltage Selection
The output voltage may be set to any voltage between
0.6V and 5.0V provided that the input voltage is higher
than the desired output voltage by an amount sufficient
to prevent the device from exceeding its maximum duty
cycle specification. Using the pin-strap method, VOUT can
be set to one of three standard voltages as shown in
Table 2.
TABLE 2. PIN-STRAP OUTPUT VOLTAGE SETTINGS
VSET
VOUT
LOW
1.2V
OPEN
1.5V
HIGH
3.3V
FN6852.2
February 11, 2010
ZL2106
TABLE 3. ZL2106 START-UP SEQUENCE
STEP #
STEP NAME
1
Power Applied
2
Internal Memory
Check
3
DESCRIPTION
Input voltage is applied to the ZL2106’s VDD pins (VDDP
and VDDS).
The device will check for values stored in its internal
memory. This step is also performed after a Restore
command.
Multi-mode Pin Check The device loads values configured by the multi-mode pins.
4
Device Ready
5
Pre-ramp Delay
The device is ready to accept an enable signal.
The device requires approximately 2ms following an enable
signal and prior to ramping its output. Additional pre-ramp
delay may be configured using the SS pin.
TABLE 4. RESISTORS FOR SETTING OUTPUT VOLTAGE
TIME DURATION
Depends on input supply
ramp time
Approx 5ms to 10ms (device
will ignore an enable signal or
PMBus traffic during this
period)
Approximately 2ms
The resistor setting method can be used to set the output
voltage to levels not available in Table 2. To set VOUT
using resistors, use Table 4 to select the resistor that
corresponds to the desired voltage.
RSET
(kΩ)
VOUT
(V)
10
0.6
11
0.7
12.1
0.75
13.3
0.8
Start-up Procedure
14.7
0.9
16.2
1.0
17.8
1.1
The ZL2106 follows a specific internal start-up procedure
after power is applied to the VDD pins (VDDP and
VDDS). Table 3 describes the start-up sequence.
19.6
1.2
21.5
1.25
23.7
1.3
26.1
1.4
28.7
1.5
31.6
1.6
34.8
1.7
38.3
1.8
42.2
1.9
46.4
2.0
51.1
2.1
56.2
2.2
61.9
2.3
68.1
2.4
75
2.5
82.5
2.6
90.9
2.7
100
2.8
110
2.9
121
3.0
Soft-start Delay and Ramp Times
133
3.1
147
3.2
162
3.3
178
5.0
It may be necessary to set a delay from when an enable
signal is received until the output voltage starts to ramp
to its target value. In addition, the designer may wish to
set the time required for VOUT to ramp to its target value
after the delay period has expired. These features may
14
The output voltage may also be set to any value between
0.6V and 5.0V using the I2C interface. See Application
Note AN2033 for details.
If the device is to be synchronized to an external clock
source, the clock frequency must be stable prior to
asserting the EN pin. The device requires approximately
5ms to 10ms to check for specific values stored in its
internal memory. If the user has stored values in
memory, those values will be loaded. The device will then
check the status of all multi-mode pins and load the
values associated with the pin settings.
Once this process is completed, the device is ready to
accept commands via the I2C/SMBus interface and the
device is ready to be enabled. Once enabled, the device
requires approximately 2ms before its output voltage
may be allowed to start its ramp-up process. If a
soft-start delay period less than 2ms has been configured
(using PMBus commands), the device will default to a
2ms delay period. If a delay period greater than 2ms is
configured, the device will wait for the configured delay
period prior to starting to ramp its output.
After the delay period has expired, the output will begin
to ramp towards its target voltage according to the preconfigured soft-start ramp time that has been set using
the SS pin. It should be noted that if the EN pin is tied to
VDDP or VDDS, the device will still require approximately
5ms to 10ms before the output can begin its ramp-up as
described in Table 3.
FN6852.2
February 11, 2010
ZL2106
be used as part of an overall inrush current management
strategy or to control how fast a load IC is turned on. The
ZL2106 gives the system designer several options for
precisely and independently controlling both the delay
and ramp time periods.
TABLE 6. DELAY AND RAMP CONFIGURATION
RSS
(kΩ)
DELAY
TIME
(ms)
10
5
11
10
12.1
20
13.3
5
14.7
10
16.2
20
17.8
5
19.6
10
21.5
20
23.7
5
26.1
10
TABLE 5. SOFT-START DELAY AND RAMP SETTINGS
28.7
20
31.6
5
SS PIN SETTING
DELAY AND
RAMP TIME
(ms)
34.8
10
LOW
2
38.3
20
OPEN
5
42.2
5
HIGH
10
46.4
10
51.1
20
56.2
5
61.9
10
68.1
20
75
5
82.5
10
90.9
20
100
5
110
10
121
20
133
5
147
10
162
20
The soft-start delay period begins when the EN pin is
asserted and ends when the delay time expires. The
soft-start delay period is set using the SS pin. Precise
ramp delay timing mode reduces the delay time
variations and is available when the appropriate bit in the
MISC_CONFIG register had been set. Please refer to
Application Note AN2033 for details.
The soft-start ramp timer enables a precisely controlled
ramp to the nominal VOUT value that begins once the
delay period has expired. The ramp-up is guaranteed
monotonic and its slope may be precisely set using the
SS pin. Using the pin-strap method, the soft-start delay
and ramp times can be set to one of three standard
values according to Table 5.
UVLO
7.5V
If the desired soft-start delay and ramp times are not
one of the values listed in Table 5, the times can be set to
a custom value by connecting a resistor from the SS pin
to SGND using the appropriate resistor value from
Table 6. The value of this resistor is measured upon
start-up or Restore and will not change if the resistor is
varied after power has been applied to the ZL2106
(see Figure 15).
SS
ZL
RSS
RAMP
TIME
(ms)
UVLO
(V)
5
4.5
10
2
5
5.5
10
20
2
5
7.5
10
20
FIGURE 15. SS PIN RESISTOR CONNECTIONS
The soft-start delay and ramp times can also be set to
custom values via the I2C/SMBus interface. When the SS
delay time is set to 0ms, the device will begin its
ramp-up after the internal circuitry has initialized
(~2ms). When the soft-start ramp period is set to 0ms,
the output will ramp up as quickly as the output load
capacitance and loop settings will allow. It is generally
recommended to set the soft-start ramp to a value
greater than 500µs to prevent inadvertent fault
conditions due to excessive inrush current.
15
FN6852.2
February 11, 2010
ZL2106
Power-good (PG)
TABLE 7. SYNC PIN FUNCTION SELECTION
The ZL2106 provides a Power-good (PG) signal that
indicates the output voltage is within a specified
tolerance of its target level and no fault condition exists.
By default, the PG pin will assert if the output is within
+15%/-10% of the target voltage. These limits may be
changed via the I2C/SMBus interface. See Application
Note AN2033 for details.
CFG PIN
SYNC PIN FUNCTION
LOW
SYNC is configured as an input
OPEN
Auto detect mode
HIGH
SYNC is configured as an output fSW = 400kHz
CONFIGURATION A: SYNC OUTPUT
A PG delay period is the time from when all conditions for
asserting PG are met and when the PG pin is actually
asserted. This feature is commonly used instead of an
external reset controller to signal the power supply is at
its target voltage prior to enabling any powered circuitry.
By default, the ZL2106 PG delay is set to 1ms and may
be changed using the I2C/SMBus interface as described
in AN2033.
When the SYNC pin is configured as an output (CFG pin is
tied HIGH), the device will run from its internal oscillator
and will drive the resulting internal oscillator signal
(preset to 400kHz) onto the SYNC pin so other devices
can be synchronized to it. The SYNC pin will not be
checked for an incoming clock signal while in this mode.
Switching Frequency and PLL
When the SYNC pin is configured as an input (CFG pin is
tied LOW), the device will automatically check for an
external clock signal on the SYNC pin each time the EN
pin is asserted. The internal oscillator will then
synchronize with the rising edge of the external clock.
The incoming clock signal must be in the range of
200kHz to 1MHz with a minimum duty cycle and must be
stable when the EN pin is asserted. The external clock
signal must also exhibit the necessary performance
requirements (see the “Electrical Specifications” table
beginning on page 6).
The ZL2106 incorporates an internal phase-locked loop
(PLL) to clock the internal circuitry. The PLL can be driven
by an external clock source connected to the SYNC pin.
When using the internal oscillator, the SYNC pin can be
configured as a clock source for other Zilker Labs
devices.
The SYNC pin is a unique pin that can perform multiple
functions depending on how it is configured. The CFG pin
is used to select the operating mode of the SYNC pin as
shown in Table 4. Figure 16 illustrates the typical
connections for each mode.
CONFIGURATION B: SYNC INPUT
SYNC
200kHz – 1MHz
ZL2106
N/C
Open
ZL2106
SYNC
OR
Logic
low
N/C
CFG
SYNC
200kHz – 1MHz
B) SYNC = input
Logic
high
CFG
N/C
ZL2106
ZL2106
SYNC
OR
RSYNC
CFG
A) SYNC = output
CFG
SYNC
200kHz – 1MHz
CFG
Logic
high
ZL2106
C) SYNC = Auto Detect
FIGURE 16. SYNC PIN CONFIGURATIONS
16
FN6852.2
February 11, 2010
ZL2106
In the event of a loss of the external clock signal, the
output voltage may show transient over/undershoot. If
this happens, the ZL2106 will automatically switch to its
internal oscillator and switch at a frequency close to the
previous incoming frequency.
The switching frequency can also be set to any value
between 200kHz and 1MHz using the I2C/SMBus
interface. The available frequencies are defined by
fSW = 8MHz/N, where whole number N is 8 ≤ N ≤ 40. See
Application Note AN2033 for details.
CONFIGURATION C: SYNC AUTO DETECT
If a value other than fSW = 8MHz/N is entered using a
PMBus command, the internal circuitry will select the
valid switching frequency value that is closest to the
entered value. For example, if 810kHz is entered, the
device will select 800kHz (N=10).
When the SYNC pin is configured in auto detect mode
(CFG pin is left OPEN), the device will automatically
check for a clock signal on the SYNC pin after enable is
asserted. If a valid clock signal is present, the ZL2106’s
oscillator will then synchronize with the rising edge of the
external clock (refer to SYNC INPUT description).
If no incoming clock signal is present, the ZL2106 will
configure the switching frequency according to the state
of the SYNC pin as listed in Table 8. In this mode, the
ZL2106 will only read the SYNC pin connection during the
start-up sequence. Changes to the SYNC pin connection
will not affect fSW until the power (VDDS) is cycled off
and on again.
TABLE 8. SWITCHING FREQUENCY SELECTION
SYNC PIN
FREQUENCY
LOW
200kHz
OPEN
400kHz
HIGH
1MHz
Resistor
See Table 9
If the user wishes to run the ZL2106 at a frequency not
listed in Table 8, the switching frequency can be set using
an external resistor, RSYNC, connected between SYNC
and SGND using Table 9.
TABLE 9. RSYNC RESISTOR VALUES
Note: The switching frequency read back using the
appropriate PMBus command will differ slightly from the
selected value in Table 9. The difference is due to
hardware quantization.
When multiple Zilker Labs devices are used together,
connecting the SYNC pins together will force all devices
to synchronize with each other. The CFG pin of one
device must set its SYNC pin as an output and the
remaining devices must have their SYNC pins set as an
input or as auto detect.
Note: Precise ramp timing mode must be disabled to use
SYNC clock auto detect.
Component Selection
The ZL2106 is a synchronous buck converter with
integrated MOSFETs that uses an external inductor and
capacitors to perform the power conversion process. The
proper selection of the external components is critical for
optimized performance.
To select the appropriate external components for the
desired performance goals, the power supply
requirements listed in Table 10 must be defined.
TABLE 10. POWER SUPPLY REQUIREMENTS
RSYNC
(kΩ)
FSW
(kHz)
10
200
11
222
12.1
242
13.3
267
14.7
296
16.2
320
17.8
364
19.6
400
Output load step (Iostep)
21.5
421
23.7
471
26.1
533
28.7
571
31.6
615
34.8
667
38.3
727
42.2
889
46.4
1000
17
PARAMETER
RANGE
EXAMPLE
VALUE
Input voltage (VIN)
4.5V to
14.0V
12V
Output voltage (VOUT)
0.6V to
5.0V
3.3V
Output current (IOUT)
0A to 6A
4A
Output voltage ripple (Vorip)
< 3% of
VOUT
±1% of VOUT
< Io
±25% of Io
Output load step rate
-
2.5A/µs
Output deviation due to load step
-
±3% of VOUT
+120°C
+85°C
Desired efficiency
-
85%
Other considerations
-
Optimize for
small size
Maximum PCB temp.
FN6852.2
February 11, 2010
ZL2106
DESIGN GOAL TRADE-OFFS
The design of the buck power stage requires several
compromises among size, efficiency and cost. The
inductor core loss increases with frequency, so there is a
trade-off between a small output filter made possible by
a higher switching frequency and getting better power
supply efficiency. Size can be decreased by increasing
the switching frequency at the expense of efficiency. Cost
can be minimized by using through-hole inductors and
capacitors; however these components are physically
large.
To start the design, select a frequency based on Table 11.
This frequency is a starting point and may be adjusted as
the design progresses.
TABLE 11. CIRCUIT DESIGN CONSIDERATIONS
FREQUENCY RANGE
EFFICIENCY
CIRCUIT SIZE
200kHz to 400kHz
Highest
Larger
400kHz to 800kHz
Moderate
Smaller
800kHz to 1MHz
Lower
Smallest
INDUCTOR SELECTION
The output inductor selection process must include
several trade-offs. A high inductance value will result in a
low ripple current (Iopp), which will reduce output
capacitance and produce a low output ripple voltage, but
may also compromise output transient load performance.
Therefore, a balance must be struck between output
ripple and optimal load transient performance. A good
starting point is to select the output inductor ripple equal
to the expected load transient step magnitude (Iostep):
I opp = I ostep
(EQ. 2)
Now the output inductance can be calculated using
Equation 3, where VINM is the maximum input voltage:
LOUT
⎛ V
VOUT × ⎜⎜1 − OUT
⎝ V INM
=
fsw × I opp
⎞
⎟⎟
⎠
(EQ. 3)
The average inductor current is equal to the maximum
output current. The peak inductor current (ILpk) is
calculated using Equation 4 where IOUT is the maximum
output current:
I Lpk = I OUT +
I opp
(EQ. 4)
2
Select an inductor rated for the average DC current with
a peak current rating above the peak current computed
in Equation 4.
In overcurrent or short-circuit conditions, the inductor
may have currents greater than 2X the normal maximum
rated output current. It is desirable to use an inductor
that still provides some inductance to protect the load
and the internal MOSFETs from damaging currents in this
situation.
18
Once an inductor is selected, the DCR and core losses in
the inductor are calculated. Use the DCR specified in the
inductor manufacturer’s data sheet.
PLDCR = DCR × I Lrms
2
(EQ. 5)
ILrms is given by Equation 6:
(I )
2
2
I Lrms = I OUT +
(EQ. 6)
opp
12
where IOUT is the maximum output current. Next,
calculate the core loss of the selected inductor. Since this
calculation is specific to each inductor and manufacturer,
refer to the chosen inductor data sheet. Add the core loss
and the DCR loss and compare the total loss to the
maximum power dissipation recommendation in the
inductor data sheet.
OUTPUT CAPACITOR SELECTION
Several trade-offs must also be considered when
selecting an output capacitor. Low ESR values are needed
to have a small output deviation during transient load
steps (Vosag) and low output voltage ripple (Vorip).
However, capacitors with low ESR, such as semi-stable
(X5R and X7R) dielectric ceramic capacitors, also have
relatively low capacitance values. Many designs can use
a combination of high capacitance devices and low ESR
devices in parallel.
For high ripple currents, a low capacitance value can
cause a significant amount of output voltage ripple.
Likewise, in high transient load steps, a relatively large
amount of capacitance is needed to minimize the output
voltage deviation while the inductor current ramps up or
down to the new steady state output current value.
As a starting point, apportion one-half of the output
ripple voltage to the capacitor ESR and the other half to
capacitance, as shown in Equations 7 and 8:
I opp
C OUT =
8 × f sw ×
ESR =
(EQ. 7)
Vorip
2
Vorip
(EQ. 8)
2 × I opp
Use these values to make an initial capacitor selection,
using a single capacitor or several capacitors in parallel.
After a capacitor has been selected, the resulting output
voltage ripple can be calculated using Equation 9:
Vorip = I opp × ESR +
I opp
8 × f sw × C OUT
(EQ. 9)
Because each part of this equation was made to be less
than or equal to half of the allowed output ripple voltage,
the Vorip should be less than the desired maximum
output ripple.
FN6852.2
February 11, 2010
ZL2106
INPUT CAPACITOR
It is highly recommended that dedicated input capacitors
be used in any point-of-load design, even when the
supply is powered from a heavily filtered 5V or 12V
“bulk” supply from an off-line power supply. This is
because of the high RMS ripple current that is drawn by
the buck converter topology. This ripple (ICINrms) can be
determined from Equation 10:
I CINrms = I OUT × D × (1 − D)
(EQ. 10)
Without capacitive filtering near the power supply circuit,
this current would flow through the supply bus and
return planes, coupling noise into other system circuitry.
The input capacitors should be rated at 1.2X the ripple
current calculated in Equation 10 to avoid overheating of
the capacitors due to the high ripple current, which can
cause premature failure. Ceramic capacitors with X7R or
X5R dielectric with low ESR and 1.1X the maximum
expected input voltage are recommended.
BOOTSTRAP CAPACITOR SELECTION
The high-side driver boost circuit utilizes an internal
Schottky diode (DB) and an external bootstrap capacitor
(CB) to supply sufficient gate drive for the high-side
MOSFET driver. CB should be a 47nF ceramic type rated
for at least 10V.
CV2P5 SELECTION
This capacitor is used to both stabilize and provide noise
filtering for the 2.5V internal power supply. It should be
between 4.7µF and 10µF, should use a semi-stable X5R
or X7R dielectric ceramic with a low ESR (less than
10mΩ) and should have a rating of 4V or more.
CVR SELECTION
This capacitor is used to both stabilize and provide noise
filtering for the 7V reference supply. It should be
between 4.7µF and 10µF, should use a semi-stable X5R
or X7R dielectric ceramic capacitor with a low ESR (less
than 10mΩ) and should have a rating of 10V or more.
Because the current for the bootstrap supply is drawn
from this capacitor, CVR should be sized at least 10X the
value of CB so that a discharged CB does not cause the
voltage on it to droop excessively during a CB recharge
pulse.
CVRA SELECTION
This capacitor is used to both stabilize and provide noise
filtering for the analog 5V reference supply. It should be
between 2.2µF and 10µF, should use a semi-stable X5R
or X7R dielectric ceramic capacitor with a low ESR (less
than 10mΩ) and should have a rating of 6.3V or more.
THERMAL CONSIDERATIONS
In typical applications, the ZL2106’s high efficiency will
limit the internal power dissipation inside the package.
However, in applications that require a high ambient
operating temperature the user must perform some
thermal analysis to ensure that the ZL2106’s maximum
junction temperature is not exceeded.
The ZL2106 has a maximum junction temperature limit
of +125°C, and the internal over-temperature limiting
19
circuitry will force the device to shut down if its junction
temperature exceeds this threshold. In order to calculate
the maximum junction temperature, the user must first
calculate the power dissipated inside the IC (PQ) as
expressed in Equation 11:
(
2
PQ = I LOAD
)[(R
DS (ON )QH
)(D) + (R
DS (ON )QL
)(1− D)] (EQ. 11)
The maximum operating junction temperature can then
be calculated using Equation 12:
T j max = TPCB + (PQ × θ JC )
(EQ. 12)
Where TPCB is the expected maximum printed circuit
board temperature and θJC is the junction-to-case
thermal resistance for the ZL2106 package.
Current Sensing and Current Limit
Threshold Selection
The ZL2106 incorporates a patented “lossless” current
sensing method across the internal low-side MOSFET
that is independent of rDS(ON) variations, including
temperature. The default value for the gain, which does
not represent a rDS(ON) value, and the offset of the
internal current sensing circuit can be modified by the
IOUT_CAL_GAIN and IOUT_CAL_OFFSET commands.
The design should include a current limiting mechanism
to protect the power supply from damage and prevent
excessive current from being drawn from the input
supply in the event that the output is shorted to ground
or an overload condition is imposed on the output.
Current limiting is accomplished by sensing the current
through the circuit during a portion of the duty cycle. The
current limit threshold is set to 9A by default. The current
limit threshold can set to a custom value via the
I2C/SMBus interface. Please refer to Application Note
AN2033 for further details.
Additionally, the ZL2106 gives the power supply designer
several choices for the fault response during over or
under current conditions. The user can select the number
of violations allowed before declaring a fault, a blanking
time and the action taken when a fault is detected. The
blanking time represents the time when no current
measurement is taken. This is to avoid taking a reading
just after a current load step (less accurate due to
potential ringing). Please refer to Application note
AN2033 for further details.
Loop Compensation
The ZL2106 operates as a voltage-mode synchronous
buck controller with a fixed frequency PWM scheme.
Although the ZL2106 uses a digital control loop, it
operates much like a traditional analog PWM controller.
Figure 17 is a simplified block diagram of the ZL2106
control loop, which differs from an analog control loop
only by the constants in the PWM and compensation
blocks. As in the analog controller case, the
compensation block compares the output voltage to the
desired voltage reference and compensation zeroes are
added to keep the loop stable. The resulting integrated
error signal is used to drive the PWM logic, converting
the error signal to a duty cycle to drive the internal
MOSFETs.
FN6852.2
February 11, 2010
ZL2106
VIN
D
L
VOUT
DPWM
1-D
C
RO
The loop compensation coefficients can also be set via
the I2C/SMBus interface. Please refer to Application Note
AN2033 for further details. Also refer to Application Note
AN2035 for further technical details on setting loop
compensation.
RC
Compensation
FIGURE 17. CONTROL LOOP BLOCK DIAGRAM
TABLE 12. RESISTOR SETTING FOR LOOP
COMPENSATION
G(dB)
Q
fsw/fn
FC
(k)
24
0.150
115.000
Open or 11
27
0.150
115.000
Low or 10
27
0.150
69.147
13.3
27
0.150
41.577
14.7
27
0.300
115.000
16.2
27
0.300
69.147
17.8
27
0.300
41.577
19.6
27
0.300
25.000
21.5
27
0.600
69.147
23.7
27
0.600
41.577
26.1
27
0.600
25.000
28.7
30
0.150
115.000
High or 12.1
30
0.150
69.147
31.6
30
0.150
41.577
34.8
30
0.300
115.000
38.3
30
0.300
69.147
42.2
30
0.300
41.577
46.4
30
0.300
25.000
51.1
30
0.600
69.147
56.2
30
0.600
41.577
61.9
30
0.600
25.000
68.1
33
0.150
115.000
75.0
33
0.150
69.147
82.5
33
0.150
41.577
90.9
33
0.300
115.000
100.0
33
0.300
69.147
110.0
33
0.300
41.577
121.0
33
0.300
25.000
133.0
33
0.600
69.147
147.0
33
0.600
41.577
162.0
33
0.600
25.000
178.0
20
In the ZL2106, the compensation zeros are set by
configuring the FC pin or via the I2C/SMBus interface
once the user has calculated the required settings. This
method eliminates the inaccuracies due to the
component tolerances associated with using external
resistors and capacitors required with traditional analog
controllers.
Driver Dead-time Control
The ZL2106 utilizes a predetermined fixed dead-time
applied between the gate drive signals for the top and
bottom MOSFETs.
In a synchronous buck converter, the MOSFET drive
circuitry must be operated such that the top and bottom
MOSFETs are never in the conducting state at the same
time. This is because potentially damaging currents flow
in the circuit if both MOSFETs are on simultaneously for
periods of time exceeding a few nanoseconds.
Conversely, long periods of time in which both MOSFETs
are off reduces overall circuit efficiency by allowing
current to flow in their parasitic body diodes.
Therefore, it is advantageous to minimize the dead-time
to provide peak optimal efficiency without compromising
system reliability. The ZL2106 has optimized the
dead-time for the integrated MOSFETs to maximizing
efficiency.
Power Management Functional
Description
Input Undervoltage Lockout
The input undervoltage lockout (UVLO) prevents the
ZL2106 from operating when the input falls below a
preset threshold, indicating the input supply is out of its
specified range. The UVLO threshold (VUVLO) can be set
to either 4.5V or 10.8V using the SS pin according to
Table 6.
The UVLO voltage can also be set to any value between
2.85V and 16V via the I2C/SMBus interface.
Once an input undervoltage fault condition occurs, the
device can respond in a number of ways as follows:
1. Continue operating without interruption.
2. Continue operating for a given delay period,
followed by shutdown if the fault still exists. The
device will remain in shutdown until instructed to
restart.
3. Initiate an immediate shutdown until the fault has
been cleared. The user can select a specific number
of retry attempts.
FN6852.2
February 11, 2010
ZL2106
The default response from a UVLO fault is an immediate
shutdown of the device. Please refer to Application Note
AN2033 for details on how to configure the UVLO
threshold or to select specific UVLO fault response
options via the I2C/SMBus interface.
pre-bias voltage is not higher than the overvoltage limit).
The PWM will then adjust its duty cycle to match the
original target voltage and the output will ramp down to
the pre-configured output voltage.
Output Overvoltage Protection
The ZL2106 offers an internal output overvoltage
protection circuit that can be used to protect sensitive
load circuitry from being subjected to a voltage higher
than its prescribed limits. A hardware comparator is used
to compare the actual output voltage (seen at the VSEN
pin) to a threshold set to 15% higher than the target
output voltage (the default setting). If the VSEN voltage
exceeds this threshold, the PG pin will de-assert and the
device can then respond in a number of ways as follows:
1. Initiate an immediate shutdown until the fault has
been cleared. The user can select a specific number
of retry attempts.
2. Turn off the high-side MOSFET and turn on the
low-side MOSFET. The low-side MOSFET remains on
until the device attempts a restart.
The default response from an overvoltage fault is to
immediately shut down. For continuous overvoltage
protection when operating from an external clock, the
only allowed response is an immediate shutdown. Please
refer to Application Note AN2033 for details on how to
select specific overvoltage fault response options via
I2C/SMBus.
Output Pre-Bias Protection
An output pre-bias condition exists when an externally
applied voltage is present on a power supply’s output
before the power supply’s control IC is enabled. Certain
applications require that the converter not be allowed to
sink current during start up if a pre-bias condition exists
at the output. The ZL2106 provides pre-bias protection
by sampling the output voltage prior to initiating an
output ramp.
If a pre-bias voltage lower than the target voltage exists
after the pre-configured delay period has expired, the
target voltage is set to match the existing pre-bias
voltage and both drivers are enabled. The output voltage
is then ramped to the final regulation value at the ramp
rate set by the SS pin.
The actual time the output will take to ramp from the
pre-bias voltage to the target voltage will vary depending
on the pre-bias voltage but the total time elapsed from
when the delay period expires and when the output
reaches its target value will match the pre-configured
ramp time (see Figure 18).
If a pre-bias voltage higher than the target voltage exists
after the pre-configured delay period has expired, the
target voltage is set to match the existing pre-bias
voltage and both drivers are enabled with a PWM duty
cycle that would ideally create the pre-bias voltage.
Once the pre-configured soft-start ramp period has
expired, the PG pin will be asserted (assuming the
21
FIGURE 18. OUTPUT RESPONSES TO PRE-BIAS
VOLTAGES
If a pre-bias voltage higher than the overvoltage limit
exists, the device will not initiate a turn-on sequence and
will declare an overvoltage fault condition to exist. In this
case, the device will respond based on the output
overvoltage fault response method that has been
selected. See “Output Overvoltage Protection” on
page 21 for response options due to an overvoltage
condition.
Output Overcurrent Protection
The ZL2106 can protect the power supply from damage if
the output is shorted to ground or if an overload
condition is imposed on the output. Once the current
limit threshold has been selected (see “Current Sensing
and Current Limit Threshold Selection” on page 19), the
user may determine the desired course of action in
response to the fault condition. The following overcurrent
protection response options are available:
1. Initiate a shutdown and attempt to restart an
infinite number of times with a preset delay period
between attempts.
FN6852.2
February 11, 2010
ZL2106
2. Initiate a shutdown and attempt to restart a preset
number of times with a preset delay period between
attempts.
3. Continue operating for a given delay period,
followed by shutdown if the fault still exists.
4. Continue operating through the fault (this could
result in permanent damage to the power supply).
5. Initiate an immediate shutdown.
6. The default response from an overcurrent fault is an
immediate shutdown of the device. Please refer to
Application Note AN2033 for details on how to select
specific overcurrent fault response options via
I2C/SMBus.
Thermal Overload Protection
The ZL2106 includes an on-chip thermal sensor that
continuously measures the internal temperature of the
die and will shutdown the device when the temperature
exceeds the preset limit. The factory default temperature
limit is set to +125°C, but the user may set the limit to a
different value if desired. See Application Note AN2033
for details. Note that setting a higher thermal limit via
the I2C/SMBus interface may result in permanent
damage to the device. Once the device has been disabled
due to an internal temperature fault, the user may select
one of several fault response options as follows:
single die. In most cases, the I/O interface operates at a
higher voltage than the core and therefore the core
supply voltage must not exceed the I/O supply voltage
according to the manufacturers' specifications.
Voltage tracking protects these sensitive ICs by limiting
the differential voltage between multiple power supplies
during the power-up and power down sequence. The
ZL2106 integrates a lossless tracking scheme that allows
its output to track a voltage that is applied to the VTRK
pin with no additional components required. The VTRK
pin is an analog input that, when tracking mode is
enabled, configures the voltage applied to the VTRK pin
to act as a reference for the device’s output regulation.
The ZL2106 offers two modes of tracking. Figure 19
illustrates the output voltage waveform for the two
tracking modes.
1. Coincident. This mode configures the ZL2106 to
ramp its output voltage at the same rate as the
voltage applied to the VTRK pin.
2. Ratiometric. This mode configures the ZL2106 to
ramp its output voltage at a rate that is a
percentage of the voltage applied to the VTRK pin.
The default setting is 50%, but an external resistor
may be used to configure a different tracking ratio.
V IN
1. Initiate a shutdown and attempt to restart an
infinite number of times with a preset delay period
between attempts.
3. Continue operating for a given delay period,
followed by shutdown if the fault still exists.
SW
VTRK
2. Initiate a shutdown and attempt to restart a preset
number of times with a preset delay period between
attempts.
ZL
VOUT
VTRK
V OUT
VTRK
4. Continue operating through the fault (this could
result in permanent damage to the power supply).
VOUT
5. Initiate an immediate shutdown.
If the user has configured the device to restart, the
device will wait the preset delay period (if configured to
do so) and will then check the device temperature. If the
temperature has dropped below a threshold that is
approximately +15°C lower than the selected
temperature fault limit, the device will attempt to restart. If the temperature still exceeds the fault limit the
device will wait the preset delay period and retry again.
The default response from a temperature fault is an
immediate shutdown of the device. Please refer to
Application Note AN2033 for details on how to select
specific temperature fault response options via
I2C/SMBus.
Voltage Tracking
Numerous high performance systems place stringent
demands on the order in which the power supply
voltages are turned on. This is particularly true when
powering FPGAs, ASICs, and other advanced processor
devices that require multiple supply voltages to power a
22
Time
Coincident
V OUT
VTRK
VOUT
Time
Ratiometric
FIGURE 19. TRACKING MODES
The master device in a tracking group is defined as the
device that has the highest target output voltage within
the group. This master device will control the ramp rate
of all tracking devices and is not configured for tracking
mode. A delay of at least 10ms must be configured into
the master device using the SS pin, and the user may
also configure a specific ramp rate using the SS pin.
Tracking mode is enabled through the CFG pin, as shown
FN6852.2
February 11, 2010
ZL2106
in Table 16, and configured through the SS pin, as shown
in Table 13.
that is continuously monitored and can be driven directly
by a processor I/O pin or other logic-level output.
Any device that is configured for tracking mode will
ignore its soft-start delay and ramp time settings (SS
pin) and its output will take on the turn-on/turn-off
characteristics of the reference voltage present at the
VTRK pin. All of the ENABLE pins in the tracking group
must be connected together and driven by a single logic
source.
The ZL2106’s output will be forced higher than its
nominal set point when the MGN command is set HIGH,
and the output will be forced lower than its nominal set
point when the MGN command is set LOW. Default
margin limits of VNOM ±5% are pre-loaded in the factory,
but the margin limits can be modified through the
I2C/SMBus interface to as high as VNOM + 10% or as low
as 0V, where VNOM is the nominal output voltage set
point determined by the VSET pin. A safety feature
prevents the user from configuring the output voltage to
exceed VNOM + 10% under any conditions.
Tracking mode can also be configured via the I2C/SMBus
interface by using the TRACK_CONFIG PMBus command.
Please refer to Application Note AN2033 for more
information on configuring tracking mode using PMBus.
Voltage Margining
The ZL2106 offers a simple means to vary its output
higher or lower than its nominal voltage setting in order
to determine whether the load device is capable of
operating over its specified supply voltage range. The
MGN command is set by driving the MGN pin or through
the I2C/SMBus interface. The MGN pin is a tri-level input
The margin limits and the MGN command can both be
set individually through the I2C/SMBus interface.
Additionally, the transition rate between the nominal
output voltage and either margin limit can be configured
through the I2C/SMBus interface. Please refer to
Application Note AN2033 for detailed instructions on
modifying the margining configurations.
TABLE 13. TRACKING MODE CONFIGURATION
RSS
(kΩ)
UVLO
(V)
TRACKING RATIO
(%)
19.6
21.5
100
23.7
26.1
28.7
UPPER TRACK LIMIT
RAMP-UP/DOWN BEHAVIOR
Limited by target voltage
Output not allowed to decrease before PG
Output will always follow VTRK
Limited by VTRK pin voltage Output not allowed to decrease before PG
Output will always follow VTRK
5.5
Limited by target voltage
31.6
50
34.8
Output will always follow VTRK
Limited by VTRK pin voltage Output not allowed to decrease before PG
38.3
Output will always follow VTRK
56.2
Limited by target voltage
61.9
100
68.1
75
82.5
Output not allowed to decrease before PG
Output not allowed to decrease before PG
Output will always follow VTRK
Limited by VTRK pin voltage Output not allowed to decrease before PG
Output will always follow VTRK
7.5
Limited by target voltage
90.9
50
100
110
Output not allowed to decrease before PG
Output will always follow VTRK
Limited by VTRK pin voltage Output not allowed to decrease before PG
Output will always follow VTRK
23
FN6852.2
February 11, 2010
ZL2106
I2C/SMBus Communications
I2C/SMBus
The ZL2106 provides an
digital interface that
enables the user to configure all aspects of the device
operation as well as monitor the input and output
parameters. The ZL2106 can be used with any standard
2-wire I2C host device.
In addition, the device is compatible with SMBus version
2.0 and includes an SALRT line to help mitigate
bandwidth limitations related to continuous fault
monitoring. Pull-up resistors are required on the
I2C/SMBus as specified in the SMBus 2.0 specification.
The ZL2106 accepts most standard PMBus commands.
When controlling the device with PMBus commands, it is
recommended that the enable pin is tied to SGND.
I2C/SMBus Device Address Selection
When communicating with multiple devices using the
I2C/SMBus interface, each device must have its own
unique address so the host can distinguish between the
devices. The device address can be set according to the
pin-strap options listed in Table 14. Address values are
right-justified.
TABLE 14. SMBus DEVICE ADDRESS SELECTION
The minimum pull-up resistance should be limited to a
value that enables any device to assert the bus to a
voltage that will ensure a logic 0 (typically 0.8V at the
device monitoring point) given the pull-up voltage (5V if
tied to VRA) and the pull-down current capability of the
ZL2106 (nominally 4mA).
TABLE 15. SMBus ADDRESS VALUES
RSA
(kΩ)
SMBus Address
10
0x20
11
0x21
12.1
0x22
13.3
0x23
14.7
0x24
16.2
0x25
17.8
0x26
19.6
0x27
21.5
0x28
23.7
0x29
SA PIN SETTING
SMBus ADDRESS
26.1
0x2A
LOW
0x20
28.7
0x2B
OPEN
0x21
31.6
0x2C
HIGH
0x22
34.8
0x2D
38.3
0x2E
42.2
0x2F
46.4
0x30
Digital-DC Bus
51.1
0x31
The Digital-DC Communications (DDC) bus is used to
communicate between Zilker Labs Digital-DC devices.
This dedicated bus provides the communication channel
between devices for features such as sequencing and
fault spreading. The DDC pin on all Digital-DC devices in
an application should be connected together. A pull-up
resistor is required on the DDC bus in order to guarantee
the rise time as expressed in Equation 13:
56.2
0x32
61.9
0x33
68.1
0x34
75
0x35
82.5
0x36
90.9
0x37
100
0x38
110
0x39
121
0x3A
133
0x3B
147
0x3C
162
0x3D
If additional device addresses are required, a resistor can
be connected to the SA pin according to Table 15 to
provide up to 30 unique device addresses.
Rise time = R PU • C LOAD ≈ 1 μ s
(EQ. 13)
Where RPU is the DDC bus pull-up resistance and CLOAD
is the bus loading. The pull-up resistor may be tied to
VRA or to an external 3.3V or 5V supply as long as this
voltage is present prior to or during device power-up. As
rules of thumb, each device connected to the DDC bus
presents approximately 10pF of capacitive loading, and
each inch of FR4 PCB trace introduces approximately 2pF.
The ideal design will use a central pull-up resistor that is
well matched to the total load capacitance. In power
module applications, the user should consider whether to
place the pull-up resistor on the module or on the PCB of
the end application.
24
FN6852.2
February 11, 2010
ZL2106
Phase Spreading
When multiple point of load converters share a common
DC input supply, it is desirable to adjust the clock phase
offset of each device such that not all devices start to
switch simultaneously. Setting each converter to start its
switching cycle at a different point in time can
dramatically reduce input capacitance requirements and
efficiency losses. Since the peak current drawn from the
input supply is effectively spread out over a period of
time, the peak current drawn at any given moment is
reduced and the power losses proportional to the IRMS2
are reduced dramatically.
In order to enable phase spreading, all converters must
be synchronized to the same switching clock. The CFG
pin is used to set the configuration of the SYNC pin for
each device as described in “Switching Frequency and
PLL” on page 16.
Selecting the phase offset for the device is accomplished
by selecting a device address according to the following
equation:
TABLE 16. CFG PIN CONFIGURATIONS FOR
SEQUENCING AND TRACKING
RCFG
SYNC PIN
CONFIGURATION
Low
Input
Open
Auto detect
High
Output
10kΩ
Input
11kΩ
Auto detect
12.1kΩ
Output
14.7kΩ
Input
16.2kΩ
Auto detect
17.8kΩ
Output
21.5kΩ
Input
23.7kΩ
Auto detect
26.1kΩ
Output
Phase offset = device address x 45°
31.6kΩ
Input
For example:
34.8kΩ
Auto detect
• A device address of 0x00 or 0x20 would configure no
phase offset
38.3kΩ
Output
• A device address of 0x01 or 0x21 would configure
45° of phase offset
46.4kΩ
Input
51.1kΩ
Auto detect
56.2kΩ
Output
• A device address of 0x02 or 0x22 would configure
90° of phase offset
The phase offset of each device may also be set to any
value between 0° and 360° in 22.5° increments via the
I2C/SMBus interface. Refer to Application Note AN2033
for further details.
Output Sequencing
A group of Zilker Labs devices may be configured to
power up in a predetermined sequence. This feature is
especially useful when powering advanced processors,
FPGAs, and ASICs that require one supply to reach its
operating voltage prior to another supply reaching its
operating voltage in order to avoid latch-up from
occurring. Multi-device sequencing can be achieved by
configuring each device through the I2C/SMBus interface
or by using Zilker Labs patented autonomous sequencing
mode.
Autonomous sequencing mode configures sequencing by
using events transmitted between devices over the DDC
bus.
The sequencing order is determined using each device’s
SMBus address. Using autonomous sequencing mode
(configured using the CFG pin), the devices must be
assigned sequential SMBus addresses with no missing
addresses in the chain. This mode will also constrain
each device to have a phase offset according to its
SMBus address as described in section “Phase
Spreading” on page 25.
25
SEQUENCING
CONFIGURATION
Sequencing and Tracking
are disabled.
Sequencing and Tracking
are disabled.
Device is FIRST in nested
sequence. Tracking
disabled.
Device is LAST in nested
sequence. Tracking
disabled.
Device is MIDDLE in nested
sequence. Tracking
disabled.
Sequence disabled. Tracking
enabled as defined in Table 13.
The sequencing group will turn on in order starting with
the device with the lowest SMBus address and will
continue through to turn on each device in the address
chain until all devices connected have been turned on.
When turning off, the device with the highest SMBus
address will turn off first followed in reverse order by the
other devices in the group.
Sequencing is configured by connecting a resistor from
the CFG pin to ground as described in Table 16. The CFG
pin is also used to set the configuration of the SYNC pin
as well as to determine the sequencing method and
order. Please refer to section “Switching Frequency and
PLL” on page 16 for more details on the operating
parameters of the SYNC pin.
Multiple device sequencing may also be achieved by
issuing PMBus commands to assign the preceding device
in the sequencing chain as well as the device that will
follow in the sequencing chain. This method places fewer
restrictions on the SMBus address (no need of sequential
address) and also allows the user to assign any phase
offset to any device irrespective of its SMBus device
address.
The Enable pins of all devices in a sequencing group
must be tied together and driven high to initiate a
sequenced turn-on of the group. Enable must be driven
low to initiate a sequenced turnoff of the group. Please
refer to Application Note AN2033 for details on
sequencing via the I2C/SMBus interface.
FN6852.2
February 11, 2010
ZL2106
Fault Spreading
Digital-DC devices can be configured to broadcast a fault
event over the DDC bus to the other devices in the
group. When a non-destructive fault occurs and the
device is configured to shut down on a fault, the device
will shut down and broadcast the fault event over the
DDC bus. The other devices on the DDC bus will shut
down together if configured to do so, and will attempt to
re-start in their prescribed order if configured to do so.
Monitoring via I2C/SMBus
A system controller can monitor a wide variety of
different ZL2106 system parameters through the
I2C/SMBus interface. The device can monitor for fault
conditions by monitoring the SALRT pin, which will be
pulled low when any number of pre-configured fault
conditions occur.
The device can also be monitored continuously for any
number of power conversion parameters including input
voltage, output voltage, output current, internal junction
temperature, switching frequency and duty cycle.
The PMBus host should respond to SALRT as follows:
1. ZL device pulls SALRT low.
2. PMBus host detects that SALRT is now low, performs
transmission with Alert Response Address to find
which ZL device is pulling SALRT low.
3. PMBus host talks to the ZL device that has pulled
SALRT low. The actions that the host performs are
up to the system designer.
If multiple devices are faulting, SALRT will still be low
after doing the above steps and will require transmission
with the Alert Response Address repeatedly until all faults
are cleared. Please refer to Application Note AN2033 for
details on how to monitor specific parameters via the
I2C/SMBus interface.
Snapshot™ Parametric Capture
The ZL2106 offers a special feature that enables the user
to capture parametric data during normal operation or
following a fault. The Snapshot functionality is enabled
by setting bit 1 of MISC_CONFIG to 1.
See AN2033 for details on using Snapshot in addition to
the parameters supported. The Snapshot feature enables
the user to read the parameters via a block read transfer
through the SMBus. This can be done during normal
operation, although it should be noted that reading the
22 bytes will occupy the SMBus for some time.
The SNAPSHOT_CONTROL command enables the user to
store the snapshot parameters to Flash memory in
response to a pending fault as well as to read the stored
data from Flash memory after a fault has occurred.
Table 17 describes the usage of this command.
Automatic writes to Flash memory following a fault are
triggered when any fault threshold level is exceeded,
provided that the specific fault’s response is to shut down
(writing to Flash memory is not allowed if the device is
configured to re-try following the specific fault condition).
26
It should also be noted that the device’s VDD voltage
must be maintained during the time when the device is
writing the data to Flash memory; a process that
requires between 700µs to 1400µs depending on
whether the data is set up for a block write. Undesirable
results may be observed if the device’s VDD supply drops
below 3.0V during this process.
TABLE 17. SNAPSHOT_CONTROL COMMAND
DATA
VALUE
DESCRIPTION
1
Copies current SNAPSHOT values from Flash
memory to RAM for immediate access using
SNAPSHOT command.
2
Writes current SNAPSHOT values to Flash memory.
Only available when device is disabled.
In the event that the device experiences a fault and
power is lost, the user can extract the last SNAPSHOT
parameters stored during the fault by writing a 1 to
SNAPSHOT_CONTROL (transfers data from Flash
memory to RAM) and then issuing a SNAPSHOT
command (reads data from RAM via SMBus).
Non-Volatile Memory and Device Security
Features
The ZL2106 has internal non-volatile memory where user
configurations are stored. Integrated security measures
ensure that the user can only restore the device to a
level that has been made available to them. Refer to
“Start-up Procedure” on page 14 for details on how the
device loads stored values from internal memory during
start-up.
During the initialization process, the ZL2106 checks for
stored values contained in its internal memory. The
ZL2106 offers two internal memory storage units that
are accessible by the user as follows:
1. Default Store: A power supply module manufacturer
may want to protect the module from damage by
preventing the user from being able to modify
certain values that are related to the physical
construction of the module. In this case, the module
manufacturer would use the Default Store and
would allow the user to restore the device to its
default setting but would restrict the user from
restoring the device to the factory settings.
2. User Store: The manufacturer of a piece of
equipment may want to provide the ability to modify
certain power supply settings while still protecting
the equipment from modifying values that can lead
to a system level fault. The equipment manufacturer
would use the User Store to achieve this goal.
Please refer to Application Note AN2033 for details on
how to set specific security measures via the I2C/SMBus
interface.
FN6852.2
February 11, 2010
ZL2106
Revision History
The revision history provided is for informational purposes only and is believed to be accurate, but not warranted. Please go to
web to make sure you have the latest Rev.
DATE
REVISION
02/11/10
FN6852.2
Typo on Page 24, Table 15, resistor values 34.8 and 31.6 swapped so that 31.6 is 0x2C and
34.8 is 0x2D in the table.
10/01/09
FN6852.1
1) Updated to new format. Updates include:
a) Moving Typical Application Circuits to front of datasheet, per new standard
b) Putting Abs Max, Recommended Operating Conditions and Electrical Specs tables into
Intersil format
- Adding Pb-free reflow link to Thermal info
- Adding Intersil's caution statement, per legal
- Added ESD ratings
c) Put Ordering Info table into Intersil format
- Adding Moisture Sensitivity Level note, TB347 tape and reel spec note and Pb-free note
(corresponding to lead finish). Added evaluation board.
d) Updated sales disclaimer on last page to Intersil's verbiage
e) Replaced Zilker POD with Intersil equivalent POD (L36.6x6A)
f) Updated graphics to Intersil standards (font change)
g) Updated cross references to tables (since table #s were removed from Electrical Specs,
Abs Max, Recommended Operating Conditions and Pin Descriptions tables)
h) Updated cross references to figures (since figure #s were removed from Block Diagram
and Pinout)
i) Added equation #s to all equations
j) Added Intersil standard over temp notes to Electrical Specs table as follows:
- Added Note 18: "Parameters with MIN and/or MAX limits are 100% tested at +25°C,
unless otherwise specified. Temperature limits established by characterization and are not
production tested." to MIN MAX columns of Electrical Specs table.
-Added "Boldface limits apply over the operating temperature range, -40°C to +85°C" to
common conditions of Electrical Specs table. Bolded all MIN and MAX specs in table.
k) Revised page 1. Shortened Features and added Efficiency curve
2) On page 6; Removed "low" from the “Power-good VOUT Low Threshold” line in the Electrical
Specs table
3) On page 15; “SOFT-START DELAY AND RAMP SETTINGS” table (was Table 9, now Table 5):
Changed UVLO from 4.5V to 7.5V
5) On page 15; “DELAY AND RAMP CONFIGURATION” table (was Table 10, now Table 6): Ramp
Time and Delay Time swapped columns and values changed. Updated UVLO values.
6) On page 10; 2nd column, removed 2nd paragraph "Application notes and reference .. .. to
order an evaluation kit."
7) On page 23; Table 13, “TRACKING MODE CONFIGURATION”, changed UVLO values "4.5" to
"5.5" and "10.8" to "7.5"
8) On page 23; Table 13, “TRACKING MODE CONFIGURATION”, changed Rss values from:
"42.2" to "56.2"
"46.4" to "61.9"
"51.1" to "68.1"
"56.2" to "75"
"61.9" to "82.5"
"68.1" to "90.9"
"75" to "100"
"82.5" to "110"
9) In Thermal Information, changed Thermal Tja from “35” to “28” and Tjc from “5” to “1”
10) In Thermal Information, changed Dissipation Limits from “3.25W, 2.25W, 1.25W” to “3.5W,
2.5W, 1.4W”
11) In Spec table, changed conditions for VRA and V2P5 Reference Output Voltage from
“50mA” to “20mA”
12) In Spec table, added Reference Note 19 to Soft-start Delay Duration in conditions.
13) Changed Part Numbers in Ordering Information from From “ZL2106ALBN, ZL2106ALBNT,
ZL2106ALBNTK” to “ZL2106ALCN, ZL2106ALCNT, ZL2106ALCNTK”
10/13/09
CHANGE
14) Removed “SNAPSHOT PARAMETERS” table. Added “See AN2033 for details on using
Snapshot in addition to the parameters supported. “ to “Snapshot™ Parametric Capture ” on
page 26
27
FN6852.2
February 11, 2010
ZL2106
Revision History
The revision history provided is for informational purposes only and is believed to be accurate, but not warranted. Please go to
web to make sure you have the latest Rev. (Continued)
DATE
REVISION
CHANGE
11/20/09
FN6852.1
15) On page 17. Table 9. “RSYNC RESISTOR VALUES”. Changed values of last 4 rows from:
34.8kohm | 727kHz
38.3kohm | 800kHz
46.4kohm | 889kHz
51.1kohm | 1000kHz
to:
34.8kohm | 667kHz
38.3kohm | 727kHz
42.2kohm | 889kHz
46.4kohm | 1000kHz
02/19/09
FN6852.0
Assigned file number FN6852 to datasheet as this will be the first release with an Intersil file
number. Replaced header and footer with Intersil header and footer. Updated disclaimer
information to read “Intersil and it’s subsidiaries including Zilker Labs, Inc.” No changes to
datasheet content
11/08
1.1
1) Added Notes 1, 5, 8 and 9 to Electrical Specifications Table
2) Corrected Tj = 25 °C in Figures 5 and 6
3) Added Tj ≤ 125°C in Figures 8 and 9
4) Added last paragraph to “Multi-mode Pins” on page 12
5) Changed PG delay to 1ms in “Power-good (PG)” on page 16
6) Added note for SYNC clock auto detect in “Switching Frequency and PLL” Section
7) Updated first paragraph of “Current Sensing and Current Limit Threshold Selection” on
page 19
8) Changed default fault response to immediate shutdown in “Input Undervoltage Lockout” on
page 20, “Output Overvoltage Protection” on page 21, “Output Overcurrent Protection” on
page 21 and “Thermal Overload Protection” on page 22.
9) Updated Ordering Information
8/08
1.0
Initial Release
Products
Intersil Corporation is a leader in the design and manufacture of high-performance analog semiconductors. The
Company's products address some of the industry's fastest growing markets, such as, flat panel displays, cell phones,
handheld products, and notebooks. Intersil's product families address power management and analog signal
processing functions. Go to www.intersil.com/products for a complete list of Intersil product families.
*For a complete listing of Applications, Related Documentation and Related Parts, please see the respective device
information page on intersil.com: ZL2106
To report errors or suggestions for this datasheet, please go to www.intersil.com/askourstaff
FITs are available from our website at http://rel.intersil.com/reports/search.php
For additional products, see www.intersil.com/product_tree
Intersil products are manufactured, assembled and tested utilizing ISO9000 quality systems as noted
in the quality certifications found at www.intersil.com/design/quality
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications
at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by
Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any
infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any
patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see www.intersil.com
28
FN6852.2
February 11, 2010
ZL2106
Package Outline Drawing
L36.6x6A
36 LEAD QUAD FLAT NO-LEAD PLASTIC PACKAGE
Rev 1, 9/09
4X 4.0
6.00
36X 0.50
A
B
28
6
PIN 1
INDEX AREA
36
27
6
PIN #1
INDEX AREA
6.00
1
4 .10 ± 0.10
9
19
(4X)
0.15
10
18
TOP VIEW
36X 0.60 ± 0.10
36X 0.25 4
0.10 M C A B
BOTTOM VIEW
0.10 C
MAX 0.90
0.08 C
( 5. 60 TYP )
(
C
( 36 X 0 . 50 )
SIDE VIEW
4. 10 )
C
0 . 2 REF
5
(36X 0.25 )
0 . 00 MIN.
0 . 05 MAX.
( 36X 0.80 )
DETAIL "X"
TYPICAL RECOMMENDED LAND PATTERN
NOTES:
1.
Dimensions are in millimeters.
Dimensions in ( ) for Reference Only.
2.
Dimensioning and tolerancing conform to AMSE Y14.5m-1994.
3.
Unless otherwise specified, tolerance : Decimal ± 0.05
4.
Dimension b applies to the metallized terminal and is measured
between 0.15mm and 0.30mm from the terminal tip.
5.
Tiebar shown (if present) is a non-functional feature.
6.
The configuration of the pin #1 identifier is optional, but must be
located within the zone indicated. The pin #1 indentifier may be
7.
Compliant to JEDEC MO-220VJJD.
either a mold or mark feature.
29