Bulletin 700S-CF Industrial Relays Overview/Product Selection Bulletin 700S-CF Table Of Contents • • • • Product Selection . . . . . . 197 Specifications . . . . . . . . . 199 Approximate Dimensions . . . . . . . . . . . 200 IEC Industrial Safety Relay Positively Guided/Mechanically Linked Contacts as Per IEC 947-5-1 Annex L Third Party Certification By SUVA Red Cover and Mechanically Linked Contact Symbol on Front Face Type CF Safety Control Relays — 8-Pole AC Voltage AC-1 AC-11 and AC-15 Connection Diagrams Ie [A] Ie [A] Main Contacts 40°C 60°C 24/48V 120V 240V 400V 500V 600V Contacts Catalog Number ➊ Auxiliary Contacts 690V A1 53 61 71 81 54 62 72 82 43 53 61 71 83 44 54 62 72 84 13 21 33 43 14 22 34 44 13 21 33 14 22 34 K1 N.O. N.C. 4 4 700S-CF440⊗C 5 3 700S-CF530⊗C 6 2 700S-CF620⊗C A2 Main Contacts 25 20 16 14 10 5 2.5 1.8 1 A1 K1 A2 Adder Deck Contacts A1 10 6 6 6 3 2 2 1.2 0.7 13 21 33 43 53 61 73 83 14 22 34 44 54 62 74 84 K1 A2 ➊ All Cat. Nos. are factory-stocked. ⊗ AC Voltage Suffix Code Voltage 12 50 Hz 60 Hz 50/60 Hz Voltage 50 Hz 60 Hz 50/60 Hz R Q – 230 – – KF 24 K J KJ 230240 VA – – 32 36 V – – W V – 240 T A KA 42 48 X – – 100 Y X KY 277 KP – KP 347 – T – 100110 – KP – – E – 120 D – KD 380400 380 – I – 110 P D – S – – – – KN 400415 G – – 400 N – – 127 200 KG – KG 440 B N KB 200220 – KG – 480 – B – – H – 208240 – L – 220230 F – – 500 550 600 208 M – – C – – – C – ➊ All Cat. Nos. are factory-stocked. ➋ See page 198 for coil voltage selection information. 197 Bulletin 700S-CF Industrial Relays Product Selection, Continued Ordering Details Type CF Control Relays — 8-Pole DC Voltage DC-1 DC-11 and DC-15 Connection Diagrams Ie [A] Ie [A] Main Contacts 40°C 60°C 24/48V 120V 240V 400V 500V 600V 690V A1 Contacts Catalog Number ➊ ➋ Auxiliary Contacts N.O. 13 21 33 43 53 61 71 81 14 22 34 44 54 62 72 82 13 21 33 43 53 61 71 83 14 22 34 44 54 62 72 84 K1 A2 25 20 16 14 10 5 2.5 1.8 1 A1 K1 A2 A1 13 21 33 43 53 61 73 83 14 22 34 44 54 62 74 84 K1 A2 N.C. 4 4 700S-CF440Z⊗C 5 3 700S-CF530Z⊗C 6 2 700S-CF620Z⊗C ➊ All Cat. Nos. are factory-stocked. ➋ See page 198 for coil voltage selection information. ⊗ DC Voltage Suffix Code ➌ Voltage Standard With diode suppressor å 9 R 12 Q — — 24 J 36 W DJ — 48 Y — 60 Z 64 B — 72 G — 80 E — 110 D — — 115 P — 125 S — 220 A 230 F — — 250 T — ➌ When ordering DJ coil with built-in surge suppression, remove Z from the Cat. No. Example: Cat. No. 700S-CF440Z⊗C becomes Catalog Number 700S-CF440DJC Accessories Safety Control Relays with Auxiliary contact block for side mounting 1- or 2-pole Electronic Timing Module on coil terminal side Mechanical Interlock on side of contactor Interface Module on coil terminal side Surge Suppressor on coil terminal side Labeling with label sheet marking tag sheet with clear cover marking tag adapter for System Bul. 1492W 198 mm. a+9 b + 24 a+9 b+9 b+3 +0 +0 + 5.5 (inches) (a + 23/64) (b + 15/16) (a + 23/64) (b + 23/64) (b + 1/8) (+ 0) (+ 0) (+ 7/32) Bulletin 700S-CF Industrial Relays Specifications General Main Relay Cat. No. 700S-CF ➌ A600, P600 Contact Ratings — NEMA Standard Min. Contact Rating Sidemounted Contacts A600, Q600 Mechanical Life 20V, 10 mA Gold Contact Ratings — IEC AC-15 (solenoids, contactors) at rated voltage IEC 947, EN 60947 12V, 8 mA 24V 16 A 6A 6A 48V 16 A 6A 6A 120V 14 A 6A 6A 240V 10 A 5A 3A 400V 5A 3A 2A 480V/500V 2.5 A 1.6 A 2A 600V 1.8 A 1.2 A 1.2 A 1A 1.0 A 690V 40°C AC-12 (Control of resistive loads) IEC 60947 Front Adder Deck Contacts 60°C Ith 0.7 A 10 A 25 A < 1ms, Resistive Loads IEC 60947 DC-13 IEC 60947, Solenoids and contactors 15 15 Electrical Life [Mil] 1.5 1.5 Weight AC Op. Mechanism [g] 390 — Terminal Cross-Sections Terminal Type Terminal Size per IEC 947-1 Solid/Stranded 1 Conductor 2 Conductor ➌ 16…10 18…14 8.9…22 8.9…13.3 [N•m] 1…2.5 1…1.5 17 kW Tightening Torque 30 kW 8 kW 400V 14 kW 690V 24 kW 24V 2 x A4 0.5…2.5 0.75…2.5 [AWG] 690 V 230V 2 x A4 1.5…6 1.5…6 [lb.-in.] 10 kW 6A [mm2] [mm2] Max. Wire Size per UL/CSA 400 V ➌ For 16 or more strands, end ferrule is required DC Switching Ratings for 700S-CF Main Poles in Series (Resistive Load at 60° C) DC-12 Switching DC Loads L/R [Mil] 230 V 20 A Aux./Pneumatic Timer Contact (Frontmounted) AC-15 (240V, 3 A) Tightening Torque Ith Cat. No. 700S-CF 12 A 12 A 48V 9A 9A 110V 3.5 A 3.5 A 220V 0.55 A 0.55 A 440V 0.2 A 0.2 A 24V 5A 5A 1 pole 2 poles 3 poles 24/48 V 25/20 A 25 A 25 A 125 V 6A 25 A 25 A 220 V 1.5 A 8A 25 A 440 V 0.4 A 1A 3A 3A 48V 2A 2A 1.5 A 125V 0.7 A 0.7 A 0.6 A 220V 0.25 A 0.25 A 0.3 A 440V 660V 0.12 A 0.14 A 0.12 A 0.1 A 0.2 A 0.1 A Yes Yes ➊ Location State of N.C. Contacts if N.O. contact welds of welded Front Left side Right side N.O. Main aux. aux. aux. contacts Positive ly Guided Contact s➋ Main Open Open ➊ Open Open Front aux. Open Open ➊ Open Open Left side aux. Open Open ➊ Open Open Right side aux. Open Open ➊ Open Open ➊ If the accessory is a pneumatic timer or latch, there is no positive guidance; the accessory contacts are independent. ➋ Defined in IEC 947-5-1 annex L. Positive guidance is a relationship between contacts of opposite types (i.e., N.O. and N.C.). 199 Bulletin 700S-CF Industrial Relays Approximate Dimensions Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended for manufacturing purposes. c2 ➊ c1 c AC Safety Control Relays a b 45 (1-25/32) c 81 (3-3/16) c1 119.5 (4-3/4) ∅d c2 114.5 (4-43/64) 6 (1/4) d1 2 - 4.5 (2 - 3/16) d2 Cat. No. 60 (2-23/64) 35 (1-25/64) d1 d2 700S-CF DC Safety Control Relays a b 45 (1-25/32) c 81 (3-3/16) c1 145.5 (5-49/64) 140.5 (5-37/64) ∅d c2 6 (1/4) 2 - 4.5 (2 -3/16) 60 (2-23/64) 35 (1-25/64) Cat. No. 700S-CF Mounting Positions Mounting Position AC Safety Control Relays DC Safety Control Relays Safety Relay Circuit With 5 Safety Outputs • Use for E-stop control. E-stop will work properly if any one fault occurs (a fault could be one welded contact or one undesired open connection such as a loose wire). • High output switching capability and long contact life. • Circuit complies with EN 954 categories 1, 2, 3, 4 • Prevents restart of the 5 safety outputs if there is a single fault anywhere in the system. Use (3) 700S-CF relays and this diagram to construct the circuit, or contact your local Allen Bradley sales office for pre-assembled module 200 Bulletin 700S-CF Industrial Relays Approximate Dimensions, Continued . Basic Circuit (1) Output Circuit (3 Relays, 9 Terminal Blocks) 13 14 13 14 33 34 A1 2 4 5 7 8 9 10 11 700S-CF 620* C A2 ➊ 700-Z Included in Factory Wired Units 21 22 21 A1 22 A2 1 3 5 7 8 9 10 11 700S-CF 350* C A2 4 6 7 8 9 10 11 700S-CF 620* C ➊ ➊ 61 13 62 43 44 21 22 A1 14 33 34 43 44 53 54 73 74 83 84 33 LOAD 1 34 (5) Output Circuit (3 Relays, 17 Terminal Blocks) 14 15 18 16 51 52 61 62 71 72 81 82 19 22 44 53 54 63 64 73 74 20 23 26 17 43 21 24 27 25 28 29 LOAD 2 LOAD 3 LOAD 4 LOAD 5 ➊ Numbers shown are the line numbers where the contacts for this relay appear. 201