Do you ever worry about power failure? POWER HiCORDER 8714-01,8715-01 Recorders Introducing easy-to-use power monitoring recorders! See what you’ve been missing ! ★ Capture Spikes, Sags, and Surges ★ Monitor and record power anomalies and fluctuations easily, even unattended ★ Analyze Leakage Currents as well as AC/DC Current up to 2000 amps ★ True-RMS with Trigger Function ★ 250µsec Transient Waveform Capture 2 Record power anomalies accurately with simple operation ! - Aplications What a Power Recorder Does There are many power-quality concerns in today's sags, and record voltage changes with simple operation, PC-based businesses, and detecting power anomalies and even monitor and record while totally unattended. is important for maintaining factory facilities and The compact B5 size and 1.5kg (52.9oz.) weight provide equipment. The POWER HiCORDERs 8714-01 and excellent portability among worksites. (8714-01) 8715 -01 are monitoring recorders that can capture instantaneous power drop-outs, brown-outs, spikes and Simple Setup 1. Simple setup. No worries about operability. 2. Accepts direct input of line voltages up to 400 V, and up to 1000 V AC/ 2000 V DC with the use of the DIFFERENTIAL PROBE 9322 accessory. 3. Voltage and current can be simultaneously measured on four isolated channels. 4. Data immediately before an anomaly occurs can be stored and recorded. 5. High quality data printouts on site. 6. High-speed A/D converter stores data in memory, providing simple recording of events that cannot be recorded by a pen recorder. 7. Two measurement functions are available: Waveform Measurement Mode (memory mode), and RMS Trend Measurement Mode (RMS recorder & memory). 8. HIOKI clamp-on probes (voltageoutput type) can be directly connected. Example To monitor the current waveform on a 220 V power line. [ Setup ] Measurement mode is set to Waveform, time axis to 2ms. Recording length is set to 20 division. [ Channel setup ] For current waveforms, after selecting a clamp-on probe for the input type from Mode, select the range of the clamp. Here, we select 9010 and 100A. Set the range of the clamp-on probe in the same way. [ Starting Measurement ] Clamp the probe around the conductor to be measured. Press the START button. The current waveform is displayed on the screen. To stop measuring, press the STOP button. Current Waveform Example Two models: the two-channel (8714-01) and four-channel (8715-01) - Specifications Basic Specifications 8714-01 8715-01 Waveform Measurement (Power Waveform Observation) Mode Waveform Measurement mode (Power Waveform Observation), Measurement Mode RMS Trend Measurement mode (RMS Observation) Time axis Input channels fixed, Analog 2 channels Input channels fixed, Analog 4 channels Input types and Inter-channels and input-frame isolation number of channels Inter-channels and input-frame isolation Sampling period Recording length 400k sample/s (2.5μs period) 200 and 400µs, 1, 2, 5, 10, and 20ms/division, time axis zoom ×2 to ×10; 3 settings, compression 1/2 to 1/50; 5 settings 1/80 of time axis ranges (minimum sampling period 2.5µs) 20, 50, 100, 200, or 400 division (800 division at sequential save OFF) Can record data from before the trigger point, 0/10/20/50, or 100% of recording length Maximum sampling rate Simultaneous sampling for 2 or 4 analog channels Pre-trigger Memory capacity continuous 2-channels measurement (12-bit analog) × 64 kilo-words/ ch Other functions External memory PC Card TYPE II slot × 1 : Flash ATA card (max.1 GB), MS-DOS format. Memory contents : Settings data, Measurement data (binary or text format), Screen data (BMP) RMS Trend Measurement (RMS Fluctuation Measurement) Mode Measurement objective Commercial mains power (50/60Hz) 25°C/ 77°F). Time axis Backup function continuous 4-channels measurement (12-bit analog) × 64 kilo-words/ ch Clock, waveform data and settings, Battery life approx. 5 years (at Terminal block : trigger input/output External control Environment conditions Operation: +5°C/41°F to +40°C/104°F, 35% to 80% relative humidity. Storage: -10°C/14°F to +50°C/122°F, 35% to 80% relative humidity. (no condensation) Safety: EN61010 Sampling period Recording length RMS accuracy Applicable standards EMC: EN61326, EN61000-3-2, EN61000-3-3 Power supplies Power consumption Continuous operation time Charge time Dimensions and mass Supplied accessories (1) AC Adapter model 9418 -15 or 9418 -10 (DC 12V ±10%) (2) BATTERY PACK 9447 (AC adapter has priority when used in combination with battery pack, fast recharge possible with AC adapter) Waveform display area 15VA max. Approx. 3 hours (with BATTERY PACK 9447, trigger standby at 23°C/ 73°F) Approx. 2 hours fast charge with power switch OFF (at 23°C/ 73°F) approx. 280 (11.02) W × 170 (6.69) H × 52 (2.05) approx. 280 (11.02) W × 170 (6.69) H × 52 (2.05) Dmm (inch), 1.5kg/ 52.91oz (without batteries) Dmm (inch) , 1.6kg/ 56.44oz (without batteries) Instruction manual ×1, Measurement guide ×1, Recording paper × 1, Paper attachment ×2, Blank box ×1, Strap ×1, AC ADAPTER 9418 -15 ×1, CONNECTION CORD 9197 ×2 (8714-01), ×4 (8715-01), Application disk ×1 Other functions 1/2/5 seconds/DIV (cannot realtime print); 10/30 seconds; 1/2/5/10/30 minutes; or 1hour/DIV, time axis compression 1/2 to 1/50; 5 settings 250µs fixed (RMS value 800 data/second) Continuous measurement only (up to 200 division of data are stored internally) ±3 % f.s. 100V Line: 75 to 125V rms (standard) 200V Line: 150 to 250V rms (standard) 400V Line: 275 to 525V rms (standard) Clamp: 0A rms to f.s.value on clamp-on probe (rms) 9322 Differential probe: 400V Line; 275 to 525V rms (standard) 9322 Differential probe: 600V Line; 475 to 725V rms (standard) Voltage axis normal (×1/2), magnified (×5), Left-right waveform scroll, Automatic, manual and partial (between A-B cursors) printing, Hybrid recording: prints logging data for each division together with waveform RMS Trend Measurement (Instantaneous Waveform Measurement) Mode Time axis Sampling period Recording length Pre-trigger Other functions 170 mm (6.69 in) Voltage axis normal (×1/2), magnified (×1), Left-right waveform scrolling, Automatic, manual and partial (between A-B cursors) printing 200 and 400µs, 1, 2, 5, 10, and 20ms/division, time axis zoom ×2 to ×10; 3 settings, compression 1/2 to 1/50; 5 settings 1/80 of time axis ranges (minimum sampling period 2.5µs) 20, 50, 100, or 200 division (400 division at sequential save OFF) Can record data from before the trigger point, 0/10/20/50, or 100% of recording length Voltage axis normal (×1/2), magnified (×1), Left-right waveform scroll Other Functions General 52 mm (2.05 in) 280 mm (11.02 in) Mass (8714-01) : approx. 1.5kg/52.91oz Mass (8715-01) : approx. 1.6kg/56.44oz DMM Function Printing of settings including input range, trigger time, etc., cursor measurement, start condition retention, auto setup, list & gauge printing, power-save function, DMM function (voltage shown as numerals on the display), auto saving, partial saving (between A-B cursors or all data), sequential save. Display update rate: 1 second Display contents: RMS value (only measuring DC and 50/60Hz) Display digit: 4 (last digit 0 to 4 is rounded zero, 5 to 9 is rounded five) Voltage ranges: Auto-select only (five ranges from 10 mV to 100 V/ div.) Accuracy: ±3% rdg. ±5dgt. Recording and Display Section Display Recording paper Recording area Recording speed 5.7-inch STN color LCD, with English/Japanese language selector 240 × 320 dots 112mm (4.41in) × 18m (59.06ft), thermal paper roll 100mm in full scale (10 divisions), 1 division = 10mm (0.39in) Max. 1sec/division (with AC adapter use) Trigger Function (only for anomalous waveform measurement and instantaneous power fluctuation recording) Trigger source Analog input CH1 - CH4 (8714-01: CH1 - CH2), external (either ON or OFF for each source), logical AND/OR of sources Level trigger: At preset voltage level, on either rising or falling edge Window trigger: At entry or exit from preset upper and lower limits Voltage drop trigger: Especially for 50/60Hz commercial power, Anomalous when peak voltage falls below preset value waveform triggers Period trigger: When period of rising or falling edge of measured signal exceeds preset period Waveform judgment trigger: Especially for 50/60Hz commercial power, to monitor signals outside of judgment range in real time (when time axis range 20ms/division is not applicable) Voltage drop trigger: Especially for 50/60Hz commercial power, when peak voltage falls below preset value Power fluctuation measurement triggers RMS level trigger: At preset effective value, on either rising or falling edge (valid only when instantaneous waveform measurement is enabled) RMS window trigger: At entry or exit from preset upper and lower limit levels 0, 10, 20, 50, 100% (for anomalous waveform measurement, instantaneous Pre-Trigger power fluctuation recording) Level setting resolution 0.25% f.s. (f.s.=10 divisions, 0.1% f.s. for use with waveform judgment trigger) Off/On (0.5 divisions fixed filter width) Trigger filter Input section (accuracy at 23 ±5 ˚C/73 ±9 ˚F after 30 minutes warm-up time; accuracy guaranteed for 1 year) Input Isolated BNC terminal, Input item: Voltage, 9010, 9018, 9132, 3283, 3284, 3285, 9322 (selectable) Voltage : 100, 200, 400V line, or 100V DC 9010 : 10, 20, 50, 100, 200, or 500A 9018 : 10, 20, 50, 100, 200, or 500A 9132 : 20, 50, 100, 200, 500, or 1000A Measurement range 3283 : 10mA, 100mA, 1, 10, or 200A 3284 : 20 or 200A 3285 : 200 or 2000A 9322 : 400 or 600V line Max. sampling rate Accuracy, frequency characteristics Low-pass filter Input resistance and capacitance Input coupling Max. allowable input 400kS/s (simultaneous sampling of all channels) ±0.5% f.s. (applied accuracy of clamp-on probe), DC to 50kHz ±3dB OFF, 500Hz, 5kHz 1MΩ, 7pF approx. (at 100kHz) DC (fixed) 450V AC rms, DC CAT II (upper voltage which when applied to between input pins does not damage them) Max. rated voltage 450V AC rms, DC (upper voltage which when applied to input channel casing or between input channels does not damage them) to earth Composition of options Note: Product names appearing herein are trademarks or registered trademarks of various companies. Record Current Waveform CARRYING CASE 9648 Hard case type, for storing options Supplied with PC Card adapter CARRYING CASE 9391 Soft case type, for storing options Holds more options than the 9648 hard case CLAMP ON AC/DC HiTESTER 3285 200A or 2000A AC/DC, with analog output of 1V f.s. DC, and waveform monitor output of 1V f.s. AC at 10Hz to 1kHz, or DC. Requires the AC ADAPTER 9445-02/-03 CLAMP ON PROBE 9018-10 Input from 10 to 500A 40Hz to 3kHz for 0.2V AC output. BNC terminal CLAMP ON AC/DC HiTESTER 3284 20A or 200A AC/DC, with analog output of 1V f.s. DC, and waveform monitor output of 1V f.s. AC at 10Hz to 2kHz, or DC. Requires the AC ADAPTER 9445-02/-03 PC CARD 128M 9726 (128MB capacity) PC CARD 256M 9727 (256MB capacity) PC Card Precaution U s e o n l y P C C a rd s s o l d PC CARD 512M 9728 by HIOKI . Compatibility (512MB capacity) and performance are not guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards. Record Current Waveform C CARD 1G 9729 P (1GB capacity) Not CE certified CLAMP ON PROBE 9132-10 Input from 20 to 1000A 40Hz to 1kHz for 0.2V AC output. BNC terminal WAVE PROCESSOR 9335 Data conversion, print functions, waveform display, compatible with Windows 95/98/Me, Windows NT 4.0/2000/XP Input from power-concent CONCENT INPUT CORD 9448 Use for 100V commercial line, 2m length 1kV AC, 2kV DC input CLAMP ON LEAK HiTESTER 3283 For leakage current measurement, includes 10mA to 200A ranges, with analog output of 1V f.s. DC, and waveform monitor output of 1V f.s. AC at 40Hz to 2kHz. Requires the AC ADAPTER 9445-02/-03 DIFFERENTIAL PROBE 9322 For inputs up to 2kV DC or 1kV AC, the 9322 requires the AC ADAPTER 9418-15 AC ADAPTER 9445-02/-03 Use for the 3283, 3284, 3285, for USA/CSA 9445-02, for EU 9445-03 + POWER HiCORDER 8714-01 (2ch model) POWER HiCORDER 8715-01 (4ch model) Not CE certified CONVERSION ADAPTER 9199 Banana-to-BNC, use to connect to insulation-BNC terminal on Input section Included accessories: AC ADAPTER 9418 -15 ×1, Recording paper ×1, Blank box ×1, Strap ×1, CONNECTION CORD 9197 (8714 -01: ×2, 8715 -01: ×4), Application disk ×1 RECORDING PAPER 9234 18 m/ 59.06 feet length, 10 rolls/ 1 set BATTERY PACK 9447 7.2V, 2400mAh PAPER WINDER 220H Paper width: 70 to 220 mm, using special-purpose AC adapter LINE SPLITTER CT101A For 100V/ 15A, convenient for measuring 100V AC line current with clamp-on probe CHARGE STAND 9643 Independent of main unit the 8714-01/8715-01, use with the AC ADAPTER 9418-15 to charge one Model BATTERY PACK 9447. + Up to 450V AC input Not CE certified Not CE certified OUTPUT CORD 9094 Required along with the 9199 adapter to connect the 3283/3284/3285 to the 8714-01 or 8715-01 AC ADAPTER 9418-15 Use for the 9322, 100 to 240 V AC CONVERSION ADAPTER 9199 Banana-to-BNC, use to connect to insulation-BNC terminal on Input section CONNECTION CORD 9197 For up to 500V, 1.5 m length CONNECTION CORD 9217 Insulation BNC-to-insulation BNC, use to connect to insulation-BNC terminal on Input Module Input cords of included accessories are the 9197 only. For current measurement, please purchase the optional clamp-on probe, or clamp-on tester. AC ADAPTER 9418-15 Universal 100 to 240 V AC, 12 V DC/ 2.5 A output n Combination example: 2-channels, with current measurement Model number × quantity Main unit Paper Battery pack Current up to 500A Carrying case 8714-01×1 9234×1 (10 rolls) 9447×1 9018-10×2 9391×1 n Combination example: 4-channels, with current measurement Model number × quantity Main unit Paper Battery pack Current up to 500A Carrying case 8715-01×1 9234×1 (10 rolls) 9447×1 9018-10×4 9391×1 DISTRIBUTED BY HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: [email protected] HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: [email protected] Shanghai Representative Office : 1310 Shanghai Times Square Office 93 Huaihai Zhong Road Shanghai, 200021, P.R.China TEL +86-21-6391-0090, 0092 FAX +86-21-6391-0360 E-mail: [email protected] All information correct as of Jan. 25, 2007. All specifications are subject to change without notice. 8714E4-71E-00P Printed in Japan