AIMTEC AM2Q

Series AM2Q-Z
2 Watt | DC-DC Converter
FEATURES:








RoHS Compliant
Wide 2:1 input range
High Efficiency up to 83%
Continuous short circuit
Operating Temperature -40ºC to 85ºC
Input / Output Isolation of 500VAC
No Tantalum capacitors used inside
Over voltage protection
Models
Single output
Model
Input Voltage
(V)
Output
Voltage
(V)
Output Current
max (mA)
Isolation
(VAC)
Max
Capacitive
Load (uF)
Efficiency
(%)
4.5-9
4.5-9
4.5-9
9-18
9-18
9-18
18-36
18-36
18-36
36-75
36-75
36-75
5
12
15
5
12
15
5
12
15
5
12
15
300
130
100
300
130
100
300
130
100
300
130
100
500
500
500
500
500
500
500
500
500
500
500
500
100
100
100
100
100
100
100
100
100
100
100
100
73
78
78
75
80
81
74
78
79
73
78
78
Input Voltage
(V)
Output
Voltage
(V)
Output Current
max (mA)
Isolation
(VAC)
Max
Capacitive
Load (uF)
Efficiency
(%)
4.5-9
4.5-9
9-18
9-18
18-36
18-36
36-75
36-75
±12
±15
±12
±15
±12
±15
±12
±15
±65
±50
±65
±50
±65
±50
±65
±50
500
500
500
500
500
500
500
500
±100
±100
±100
±100
±100
±100
±100
±100
82
81
83
83
81
82
80
79
AM2Q-0505SZ
AM2Q-0512SZ
AM2Q-0515SZ
AM2Q-1205SZ
AM2Q-1212SZ
AM2Q-1215SZ
AM2Q-2405SZ
AM2Q-2412SZ
AM2Q-2415SZ
AM2Q-4805SZ
AM2Q-4812SZ
AM2Q-4815SZ
Models
Dual output
Model
AM2Q-0512DZ
AM2Q-0515DZ
AM2Q-1212DZ
AM2Q-1215DZ
AM2Q-2412DZ
AM2Q-2415DZ
AM2Q-4812DZ
AM2Q-4815DZ
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Nominal
Typical
5
12
24
48
4.5-9
9-18
18-36
36-75
LC Type
20
30
20
Filter
Start up time
No Load Input Current
Input reflected current
www.aimtec.com
F 051e R12.E
Tel: +1 514 620 2722
1 of 3
Maximum
Units
VDC
ms
mA
mA
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2Q-Z
2 Watt | DC-DC Converter
Isolation Specifications
Parameters
Conditions
Typical
3sec
500
50
500
Tested I/O voltage
Resistance
Capacitance
Maximum
Units
VAC
MOhm
pF
Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
Cross Regulation (Dual Output Models)
Over voltage protection
25% load on one output /
100% load on the other output
LL-HL
Load:0-100% unbalanced
20MHz Bandwidth
Units
%
±5
%
5
12
15
±12
±15
Continuous
Auto Recovery
±0.5
±1
±0.02
50
0
Zener Diode Clamp
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Minimum Load Current
Maximum
±1
6.2
15
18
±15
±18
V
% of Vin
%
%/oC
mV p-p
% of Max
General Specifications
Parameters
Switching frequency
Operating temperature (Dual)
Operating temperature (Single)
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Transient recovery deviation
Conditions
Typical
100% load
Derating above 60ºC
No Derating
100
Maximum
Units
100
KHz
o
C
o
C
o
C
o
C
-40 to +85
-40 to +85
-40 to +125
Free Air Convection
95
Nickel Coated Copper
10
1.08 x 0.70x 0.28 inches
27.50 x 18.00 x 7.00 mm
>1.6Mhrs ( MIL-HDBK -217F, Ground Benign, t=+25°C )
±3
% RH
g
%
Safety Specifications
Parameters
Standards
Designed to meet IEC/EN 60950-1
Pin Out Specifications
Pin
Single
Dual
1
2
3
4
5
-V Input
+V Input
+V Output
NP
-V Output
-V Input
+V Input
+V Output
Common
-V Output
NP: Not Populated
www.aimtec.com
F 051e R12.E
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2Q-Z
2 Watt | DC-DC Converter
6.35
(0.25)
6.35
(0.25)
6.35
(0.25)
7.00
(0.28)
2.70
(0.11)
4.40
(0.17)
6.60
(0.26)
18.00
(0.70)
2.65
(0.10)
Dimensions
Derating
(Dual outputs)
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.E
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only